Takeshi Hara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Takeshi Hara has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Gert Desmet
Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, 1050 Brussel, Belgium
10 shared publications Gino V. Baron
Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, B-1050 Brussels, Belgium
9 shared publicationsNobuo Tanaka
GL Sciences Inc., Japan
8 shared publicationsTohru Ikegami
Department of Biomolecular Engineering, Kyoto Institute of Technology, Japan
8 shared publicationsShunta Futagami
Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium; Department of Applied Physics and Photonics, Brussels Photonics (B-PHOT), Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium
6 shared publications- Wim De Malsche
µFlow group, Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium
6 shared publications
Latest Publications
- 20 February 2025
- Published by Elsevier in Journal of Chromatography A
- Vol. 1748, 465805
Investigation and optimization of the extra-column band broadening in micro-flow capillary liquid chromatography
- 20 February 2025
- Published by Elsevier in Journal of Chromatography A
- Vol. 1748, 465805
Investigation and optimization of the extra-column band broadening in micro-flow capillary liquid chromatography
- 1 April 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1616, 460804
Performance of small-domain monolithic silica columns in nano-liquid chromatography and comparison with commercial packed bed columns with 2 µm particles
- 1 April 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1616, 460804
Performance of small-domain monolithic silica columns in nano-liquid chromatography and comparison with commercial packed bed columns with 2 µm particles
- 21 January 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (4) , 2997-3005
In-Line Sample Processing System with an Immobilized Trypsin-Packed Fused-Silica Capillary Tube for the Proteomic Analysis of a Small Number of Mammalian Cells
Omics analysis at single-cell resolution has helped to demonstrate the shaping of cellular heterogeneity on the basis of the expression of various molecules. However, in-depth proteomic analysis of low-quantity samples has remained challenging because of difficulties associated with the measurement of large numbers of proteins by shotgun proteomics using nanoflow-liquid chromatography tandem mass spectrometry (nano-LC/MS/MS). To meet such a demand, we developed a method called in-line sample preparation for efficient cellular proteomics (ISPEC) in which cells were captured, directly lysed, and digested with immobilized trypsin within fused-silica capillaries. ISPEC minimized sample loss during the sample preparation processes with a relatively small number of mammalian cells (<1000 cells) and improved the stability and efficiency of digestion by immobilized trypsin, compared to a conventional preparation method. Using our optimized ISPEC method with nano-LC/MS/MS analysis, we identified 1351, 351, and 60 proteins from 100 cells, 10 cells, and single-cells, respectively. The linear response of the signal intensity of each peptide to the introduced cell number indicates the quantitative recovery of the proteome from a very small number of cells. Thus, our ISPEC strategy facilitates quantitative proteomic analysis of small cell population.
- 21 January 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (4) , 2997-3005
In-Line Sample Processing System with an Immobilized Trypsin-Packed Fused-Silica Capillary Tube for the Proteomic Analysis of a Small Number of Mammalian Cells
Omics analysis at single-cell resolution has helped to demonstrate the shaping of cellular heterogeneity on the basis of the expression of various molecules. However, in-depth proteomic analysis of low-quantity samples has remained challenging because of difficulties associated with the measurement of large numbers of proteins by shotgun proteomics using nanoflow-liquid chromatography tandem mass spectrometry (nano-LC/MS/MS). To meet such a demand, we developed a method called in-line sample preparation for efficient cellular proteomics (ISPEC) in which cells were captured, directly lysed, and digested with immobilized trypsin within fused-silica capillaries. ISPEC minimized sample loss during the sample preparation processes with a relatively small number of mammalian cells (<1000 cells) and improved the stability and efficiency of digestion by immobilized trypsin, compared to a conventional preparation method. Using our optimized ISPEC method with nano-LC/MS/MS analysis, we identified 1351, 351, and 60 proteins from 100 cells, 10 cells, and single-cells, respectively. The linear response of the signal intensity of each peptide to the introduced cell number indicates the quantitative recovery of the proteome from a very small number of cells. Thus, our ISPEC strategy facilitates quantitative proteomic analysis of small cell population.
- Open Access
- 1 August 2019
- Published by Elsevier in Journal of Lipid Research
- Vol. 60 (8) , 1465-1474
Improved quantitation of lipid classes using supercritical fluid chromatography with a charged aerosol detector
- 1 August 2019
- Published by Elsevier in Journal of Lipid Research
- Vol. 60 (8) , 1465-1474
Open AccessImproved quantitation of lipid classes using supercritical fluid chromatography with a charged aerosol detector
- 1 June 2019
- Published by Elsevier in Journal of Chromatography A
- Vol. 1595, 58-65
Chromatographic study of the structural properties of mesoporous silica layers deposited on radially elongated pillars
- 1 June 2019
- Published by Elsevier in Journal of Chromatography A
- Vol. 1595, 58-65
Chromatographic study of the structural properties of mesoporous silica layers deposited on radially elongated pillars
- 8 January 2019
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 144 (5) , 1809-1817
Study of peak capacities generated by a porous layered radially elongated pillar array column coupled to a nano-LC system
The performance of a porous-layered radially elongated pillar (PLREP) array column in a commercial nano-LC system was examined by performing separation of alkylphenones and peptides. The mesoporous silica layer was prepared by sol–gel processing of a mixture of tetramethoxysilane and methyltrimethoxysilane on REPs filling a 16.5 cm long, 1 mm wide channel (three lanes of 5.5 cm long channels connected by turns). The minimum plate height of 1.4 μm for octanophenone (k = 2.21) observed in isocratic mode is 5 times smaller than the smallest off-column plate height previously reported for porous pillar array columns for a retained component. This advantage is related to the earlier introduced shape of the radially elongated pillar bed that outperforms the cylindrically shaped pillar bed in terms of the plate height. In gradient mode, maximum conditional peak capacities of 220 (for a mixture of thiourea and 7 alkylphenones, tG = 180 min) and 160 (for a cytochrome c digest, tG = 150 min) were obtained. These results indicate excellent potential for implementation of this sol–gel layer in pillar array column formats.
- 8 January 2019
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 144 (5) , 1809-1817
Study of peak capacities generated by a porous layered radially elongated pillar array column coupled to a nano-LC system
The performance of a porous-layered radially elongated pillar (PLREP) array column in a commercial nano-LC system was examined by performing separation of alkylphenones and peptides. The mesoporous silica layer was prepared by sol–gel processing of a mixture of tetramethoxysilane and methyltrimethoxysilane on REPs filling a 16.5 cm long, 1 mm wide channel (three lanes of 5.5 cm long channels connected by turns). The minimum plate height of 1.4 μm for octanophenone (k = 2.21) observed in isocratic mode is 5 times smaller than the smallest off-column plate height previously reported for porous pillar array columns for a retained component. This advantage is related to the earlier introduced shape of the radially elongated pillar bed that outperforms the cylindrically shaped pillar bed in terms of the plate height. In gradient mode, maximum conditional peak capacities of 220 (for a mixture of thiourea and 7 alkylphenones, tG = 180 min) and 160 (for a cytochrome c digest, tG = 150 min) were obtained. These results indicate excellent potential for implementation of this sol–gel layer in pillar array column formats.
- 1 December 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1580, 63-71
Silica-based hybrid porous layers to enhance the retention and efficiency of open tubular capillary columns with a 5 μm inner diameter
- 1 December 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1580, 63-71
Silica-based hybrid porous layers to enhance the retention and efficiency of open tubular capillary columns with a 5 μm inner diameter
- 1 June 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1552, 87-91
Exploring the effect of mesopore size reduction on the column performance of silica-based open tubular capillary columns
- 1 June 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1552, 87-91
Exploring the effect of mesopore size reduction on the column performance of silica-based open tubular capillary columns
- 1 November 2017
- Published by Elsevier in Journal of Chromatography A
- Vol. 1523, 234-241
Preparation and evaluation of mesoporous silica layers on radially elongated pillars
- 1 November 2017
- Published by Elsevier in Journal of Chromatography A
- Vol. 1523, 234-241
Preparation and evaluation of mesoporous silica layers on radially elongated pillars
- 4 October 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (20) , 10948-10956
Chromatographic Properties of Minimal Aspect Ratio Monolithic Silica Columns
We report on a study wherein we synthesized TMOS-based silica monolithic skeletons in capillaries with an i.d. of 5 and 10 μm to produce skeleton structures with very low capillary-to-domain size aspect-ratios. These structures include the absolute minimal aspect-ratio case of a monolithic structure whose cross-section only contains a single node point. With domain-sized based reduced plate heights running as low as hmin = 1.3–1.5 for retained coumarin dyes providing a retention factor of k = 0.6–1.0, the study confirms the classic observation that ultralow aspect ratio columns generate a markedly lower dispersion than columns with a larger aspect ratio made in the past by Knox, Jorgenson, and Kennedy for the packed bed of spheres, but now for silica monoliths. The course of the reduced van Deemter curves, and more specifically the ratio of A-term versus C-term band broadening, could be interpreted in terms of the width and persistence length of the velocity bias zones in the columns. Considering the overall kinetic performance, it is found that the two best performing structures are also the structures with the lowest number of domains or node points, that is, with the lowest capillary-to-domain size aspect-ratio and, hence, resembling closest to the open-tubular format, which remains confirmed as the column format with the best kinetic performance. This is quantified by the fact that the minimal impedance values (order of Emin = 100) of the best performing ultralow aspect ratio monolithic columns are still significantly larger than the Emin values for the reference open-tubular columns (order of Emin = 15–20).
- 4 October 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (20) , 10948-10956
Chromatographic Properties of Minimal Aspect Ratio Monolithic Silica Columns
We report on a study wherein we synthesized TMOS-based silica monolithic skeletons in capillaries with an i.d. of 5 and 10 μm to produce skeleton structures with very low capillary-to-domain size aspect-ratios. These structures include the absolute minimal aspect-ratio case of a monolithic structure whose cross-section only contains a single node point. With domain-sized based reduced plate heights running as low as hmin = 1.3–1.5 for retained coumarin dyes providing a retention factor of k = 0.6–1.0, the study confirms the classic observation that ultralow aspect ratio columns generate a markedly lower dispersion than columns with a larger aspect ratio made in the past by Knox, Jorgenson, and Kennedy for the packed bed of spheres, but now for silica monoliths. The course of the reduced van Deemter curves, and more specifically the ratio of A-term versus C-term band broadening, could be interpreted in terms of the width and persistence length of the velocity bias zones in the columns. Considering the overall kinetic performance, it is found that the two best performing structures are also the structures with the lowest number of domains or node points, that is, with the lowest capillary-to-domain size aspect-ratio and, hence, resembling closest to the open-tubular format, which remains confirmed as the column format with the best kinetic performance. This is quantified by the fact that the minimal impedance values (order of Emin = 100) of the best performing ultralow aspect ratio monolithic columns are still significantly larger than the Emin values for the reference open-tubular columns (order of Emin = 15–20).