Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chidurala Saiprakash has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Capacity Market-Based Demand Response Approach for Efficient Power Distribution in Residential Microgrid

    by P Arunkumar, Chidurala Sai Prakash, Srikanth Velpula, H M Manjunatha

    This paper presents a novel Demand Response algorithm based on a capacity market framework for efficient power management in residential microgrids. The primary objective is to minimize load shedding and enable effective direct load control in smart home environments. By establishing two-way communication channels between distribution agents and smart home customers, the proposed algorithm facilitates real-time load control decisions, accurate calculation of reduction percentages and the generation of home-specific Distributed Load Consumption Factors. An agent-based residential distribution network model was developed in MATLAB/Simulink, incorporating eight clients and integrated smart appliances to validate the algorithm’s efficacy. Simulation results demonstrate that the network can maintain grid power balance through three key mechanisms: adaptive load adjustment, strategic load shifting and distributed load reduction. Under supply-constrained conditions, the approach effectively diminishes or even eliminates the necessity for load shedding. The capacity market-based paradigm proves highly advantageous for stand-alone microgrid systems, where optimal resource management is critical for ensuring system stability and enhancing customer satisfaction.

  • Open Access

    A Novel TKEO With the Decision Tree–Based Method for Fault Analysis of the HVDC Transmission Link Fed by Offshore Wind and Solar Farms

    by Rajesh Babu Damala, Ramana Pilla, V. Manoj, S. Ramana Kumar Joga, Chidurala Saiprakash, Theophilus A. T. Kambo

    Detecting and classifying various faults on high voltage DC transmission (HVDC) lines and pinpointing their locations are crucial tasks for the power system’s efficient operation. This paper presents a Teager–Kaiser energy operator (TKEO) technique with a decision tree–based fault type classifier to monitor power system faults on the HVDC transmission line. The change identification filter technique is used to identify the fault location and record it as the change initiation point (CIP). There are only three samples of the average current ( I avrg ) used at the CIP of the HVDC link. The eight indices for fault analysis are produced by the suggested TKEO approach by processing average current ( I avrg ) signals not the differential current. Electricity networks may be restored as soon as practical while minimizing economic losses to the greatest extent possible, thanks to the new method’s speedy problem identification. This state‐of‐the‐art technique improves fault localization, categorization, and identification efficiency. It also reduces the time and computational complexity needed to find faults. It is even more cost‐effective because the suggested method is connected to a nearby microgrid, which supplies a small portion of the total electricity produced by the two wind and solar farms. With a fault‐detecting efficiency of 97%, the suggested method shows a significant improvement in accuracy.


  • Open Access

    Identification of Cross-Country Fault with High Impedance Syndrome in Transmission Line Using Tunable Q Wavelet Transform

    by Pampa Sinha, Kaushik Paul, Chidurala Saiprakash, Almoataz Y. Abdelaziz, Ahmed I. Omar, Chun-Lien Su, Mahmoud Elsisi

    The transmission lines of an electricity system are susceptible to a wide range of unusual fault conditions. The transmission line, the longest part of the electricity grid, sometimes passes through wooded areas. Storms, cyclones, and poor vegetation management (including tree cutting) increase the risk of cross-country faults (CCFs) and high-impedance fault (HIF) syndrome in these regions. Recognizing and classifying CCFs associated with HIF syndrome is the most challenging part of the project. This study extracted signal characteristics associated with CCF and HIF syndrome using the Tunable Q Wavelet Transform (TQWT). An adaptive tunable Q-factor wavelet transform (TQWT) based feature-extraction approach for CCHIF fault signals with high impact, short response period, and broad resonance frequency bandwidth was presented. In the first part, the time–frequency distribution of the vibration signal is used to determine the distinctive frequency range. Adaptive optimal matching of the impact characteristic components in the vibration signal was achieved by optimizing the number of decomposition layers, quality factor, and redundancy of TQWT based on the characteristic frequency band. In the last, the TQWT inverse transform was utilized to recreate the best sub-band to boost its weak impact characteristics. The effectiveness of the approach is confirmed by simulation and experimental findings in signal processing. The best decomposition level for signature features that can be extracted has been decided by Minimum Description length (MDL). The IEEE 39-bus system is used to test the suggested approach with reactor switching and the Ferranti effect.


  • Open Access

    A Novel Benzene Structured Array Configuration for Harnessing Maximum Power From PV Array Under Partial Shading Condition With Reduced Number of Cross Ties

    by Chidurala Saiprakash, Alivarani Mohapatra, Byamakesh Nayak, Thanikanti Sudhakar Babu, Hassan Haes Alhelou

    Partial shading (PS) phenomena significantly degrade the power output from the photovoltaic (PV) array. Due to the PS effect, there is a mismatch in current between the PV modules of a series-connected PV string. As a result, in-shaded module power dissipates, resulting in increased module temperature and the creation of local hotspots. To avoid the hotspot effect, bypass diodes are connected anti-parallel to the PV modules. But the activation of bypass diodes creates multiple peaks in I-V and P-V characteristics. The effect of PS can be reduced by using a suitable array configuration and the performance of the PV array gets improved. Among all the existing PV array configurations, the total cross-tied (TCT) configuration performs better under partial shading conditions (PSCs). But the disadvantage of TCT is that it has an enormous number of tie connections, creating complexity in an array configuration and, therefore, more cable losses. The main objective of this paper is to propose a novel array configuration named benzene (BZ) configuration, which eliminates the demerits of the TCT array configuration. Benzene configuration has improved performance with fewer tie connections compared to conventional tie-connected configurations such as TCT, bridge link (BL), and honeycomb (HC). The performance of the tie-connected array configurations is analyzed under different PSCs by considering the various performance parameters such as global maximum power (GMP), the voltage at maximum power (Vmp), current at maximum power (Imp), mismatch loss (ML), shading loss (SL), fill factor (FF) and performance ratio. It is observed that the proposed benzene array configuration gives better output performance, even having lower mismatch losses with a reduced amount of tie connections. Further, the effect of the bypass diode on a partially shaded PV string is investigated through MATLAB Simulation and experimental analysis.


  • Parameter Estimation of Photovoltaic Module Using Sine Cosine Algorithm

    by Alivarani Mohapatra, Chidurala Saiprakash, Byamakesh Nayak, Sarita Samal, Usharani Raut


  • Fault Diagnosis in PV system using DWT and Ensembled k-NN Machine Learning Classifier

    by S Ramana Kumar Joga, Chidurala Saiprakash, Alivarani Mohapatra, Pampa Sinha, Byamakesh Nayak, M K Maharana

    The output power of a photovoltaic (PV) system is dependent on the perfect operation of the PV array. PV arrays may experience various fault conditions as a result of open circuit, short circuit, and partial shading. A fault is an aberrant situation that can interfere with the effective execution of a PV system. To reduce power loss and harm to the PV system, design engineers must identify faults. The most common problems in PV array systems are open circuit, partial shading, hotspots, cracks and short circuit faults. Several scientists suggested fault diagnosis methods to recognize faults in PV arrays, however the majority failed to detect problems accurately and quickly. In this paper, a two-stage algorithm based on wavelet transform and ensemble KNN method is used to detect and classify faults in PV array. A 6X6 series parallel PV array is used to test the proposed methodology. MATLAB Simulink is used to model the 6X6 PV array. Wavelet Analysis tool bar is used for signal analysis.


  • Hybrid Array Configurations to Reduce Mismatch Loss of a PV Array under Partial Shading Conditions

    by Chidurala Saiprakash, Alivarani Mohapatra, Abhranil Manna, Arindam Nandi

    Partial shading condition (PSC) is regular phenomena in PV system, in which some sections of PV modules in an array are partly covered owing to the large building, moving clouds, dirt or big trees. The partial shading effect is limiting the array's power output and exhibits multiple peaks on the Power-Voltage (P-V) & Current-Voltage (I-V) characteristics. As a result, raises the power losses and decreases the array's performance. Suitable arrangement of the PV array configurations is one of the strategies for lowering the power losses. The primary goal of this paper is to provide unique hybrid PV array configuration arrangement, in which the benefits of conventional configurations have been combined. The hybrid PV array topologies which are presented in this paper are Series Parallel-Total Cross Tied (SPTCT), Honey Comb- Total Cross Tied (HCTCT), Bridge Linked- Total Cross Tied (BLTCT). The performance of the PV array topologies is evaluated in terms of maximum power generation, mismatch loss, fill factor by considering five distinct PSCs.


  • Analysis of Effect of Partial Shading on PV Array and Location of Local Maxima in PV Characteristics

    by Arindam Nandi, Abhranil Manna, Alivarani Mohapatra, Chidurala Saiprakash

    This paper presents the modelling and analysis of photovoltaic (PV) array under partial shading conditions. The characteristics of PV array have been studied under different shading conditions. The simulation model of the PV array has been designed through MATLAB simulation. Detailed analysis of the effect of partial shading and location of local maxima in power-voltage curves has been studied. This study builds the theoretical knowledge of the researchers to identify the location of local maxima points of the PV array under partial shading conditions.


  • Stockwell Transform & Data Mining based method for Fault detection and classification in PV Array

    by Chidurala Saiprakash, S Ramana Kumar Joga, Alivarani Mohapatra, Pampa Sinha, Byamakesh Nayak, Manoj Kumar Maharana

    In photovoltaic (PV) system, the output power is depending on the smooth operation of PV array. PV array may suffer from different fault condition due to open circuit, short circuit and partial shading condition. Fault is a abnormal condition that can cause hindrance to the smooth operation of PV system. Fault identification is major challenge to the design engineers to avoid power loss as well as damage to the PV system. Open circuit, short circuit and partial shading are most frequent faults that occur in PV array system. Many Researchers proposed fault diagnosis methods to recognize faults in PV array, majority failed in accurate and fast detection of faults. In this paper a novel method consists of Stockwell transform and machine learning based algorithm is used to detect and classify faults in PV array. The Necessary simulations and classification tasks are carried out in MATLAB Software.


  • Comparative Analysis of different PV Array Configurations under Partial Shading Conditions

    by Smruti Madhura Maharana, Alivarani Mohapatra, Chidurala Saiprakash, Abhinaba Kundu

    The ever-increasing demand of electrical energy has led to generation of power from many renewable energy sources. Among different renewable energy sources, solar energy is a prominent source as it is infinite, easily available, and non-polluting. Solar generated power from the photovoltaic (PV), suffers from the partial shading condition (PSC) where the performance and efficiency of the power obtained from the PV module are reduced drastically. Partial shading occurs when different modules of the array receive different irradiations. Partial shading is often caused by building shade, tree shadows and overhead clouds. To eliminate the condition of partial shading and to enhance the efficiency of the PV modules different configuration techniques are used widely. This paper analysed four different configurations namely series parallel (SP), total cross tied (TCT), bridge linked (BL) and honey comb (HC) under varied shading patterns using a 5×5 PV array structure. The modelling of the PV array structure is realized by implementing the parameters KC200GT and simulated in MATLAB/Simulink software.