Junwei Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Junwei Yan has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Bin Liang
Department of Orthopaedics, Nanjing First Hospital, Nanjing Medical University, Nanjing, China
4 shared publications Xiao Wang
Department of Orthopaedics, Nanjing Qixia District Hospital, Nanjing, China
4 shared publicationsZhaowei Yin
Department of Orthopaedics, Nanjing First Hospital, Nanjing Medical University
3 shared publicationsGadisa Musa Wako
Department of General Surgery, Nanjing First Hospital, Nanjing Medical University, Nanjing, China
2 shared publicationsHaibo Xu
Department of Orthopaedics, Nanjing Qixia District Hospital, Nanjing, China
2 shared publicationsA. -J. Aisikeerbayi
YiLi XinHua Hosp, Dept Orthopaed, Xinjiang, Peoples R China
1 shared publication
Latest Publications
- Open Access
- 13 February 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 27 (1)
Biomechanical comparison of a novel hockey-stick locking plate with a pes anserinus sparing design for Schatzker IV tibial plateau fractures
Stable fixation of Schatzker IV tibial plateau fractures is crucial for functional recovery. Conventional plating techniques can compromise the pes anserin
- 13 February 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 27 (1)
Open AccessBiomechanical comparison of a novel hockey-stick locking plate with a pes anserinus sparing design for Schatzker IV tibial plateau fractures
Stable fixation of Schatzker IV tibial plateau fractures is crucial for functional recovery. Conventional plating techniques can compromise the pes anserin
- Open Access
- 15 January 2026
- Published by Frontiers Media SA in Frontiers in Surgery
- Vol. 12, 1722354
Biomechanical evaluation of a novel hockey-stick locking plate featuring a pes anserinus-sparing design: a finite element analysis
Background: Surgical fixation for Schatzker IV tibial plateau fractures presents a clinical dilemma: achieving robust stability while avoiding impingement on the pes anserinus tendons. This study evaluated the biomechanical profile of a novel hockey-stick locking plate (NHLP), which is anatomically contoured to address this challenge by being placed anteriorly. Methods: A finite element model of a standardized Schatzker IV fracture was created. Three fixation methods were simulated: the novel hockey-stick locking plate (NHLP), the traditional T-shaped locking plate (TTLP), and the double reconstruction locking plates (DRLP). The models were subjected to four loading conditions: three physiological loads, a low axial load (500 N), a moderate combined load (1,500 N axial compression plus 150 N anterior shear force), and a high axial load (2,500 N) and a fourth “worst-case” load scenario combining a 1,700 N axial force, a 200 N anterior shear force, and a 10° varus tilt. Key biomechanical metrics, including implant stress, construct stability, fragment displacement, fracture interface mechanics and fatigue safety factor, were analyzed. Results: Under physiological loading, the NHLP construct demonstrated the lowest peak von Mises stress on the implant. At the high axial load of 2,500 N, the peak stress on the NHLP (159.8 MPa) was 15% lower than that on the TTLP (188.1 MPa) and 35% lower than that on the DRLP (245.5 MPa). In the “worst-case” scenario, all constructs exhibited high safety factors. In terms of stability, the NHLP provided displacement comparable to that of the TTLP, and both were substantially more stable than the DRLP construct, which exhibited the largest displacement under high load. Paradoxically, the DRLP construct consistently resulted in the highest degree of implant stress and the least stability. At the fracture interface, the NHLP maintained a stable environment across all loads, with key metrics remaining within a range conducive to bone healing. Conclusion: This finite element analysis demonstrated that the NHLP provides fracture stability while reducing peak implant stress under physiological loading. These findings support the biomechanical feasibility of its pes anserinus-sparing design, providing a strong rationale for further investigation.
- 15 January 2026
- Published by Frontiers Media SA in Frontiers in Surgery
- Vol. 12, 1722354
Open AccessBiomechanical evaluation of a novel hockey-stick locking plate featuring a pes anserinus-sparing design: a finite element analysis
Background: Surgical fixation for Schatzker IV tibial plateau fractures presents a clinical dilemma: achieving robust stability while avoiding impingement on the pes anserinus tendons. This study evaluated the biomechanical profile of a novel hockey-stick locking plate (NHLP), which is anatomically contoured to address this challenge by being placed anteriorly. Methods: A finite element model of a standardized Schatzker IV fracture was created. Three fixation methods were simulated: the novel hockey-stick locking plate (NHLP), the traditional T-shaped locking plate (TTLP), and the double reconstruction locking plates (DRLP). The models were subjected to four loading conditions: three physiological loads, a low axial load (500 N), a moderate combined load (1,500 N axial compression plus 150 N anterior shear force), and a high axial load (2,500 N) and a fourth “worst-case” load scenario combining a 1,700 N axial force, a 200 N anterior shear force, and a 10° varus tilt. Key biomechanical metrics, including implant stress, construct stability, fragment displacement, fracture interface mechanics and fatigue safety factor, were analyzed. Results: Under physiological loading, the NHLP construct demonstrated the lowest peak von Mises stress on the implant. At the high axial load of 2,500 N, the peak stress on the NHLP (159.8 MPa) was 15% lower than that on the TTLP (188.1 MPa) and 35% lower than that on the DRLP (245.5 MPa). In the “worst-case” scenario, all constructs exhibited high safety factors. In terms of stability, the NHLP provided displacement comparable to that of the TTLP, and both were substantially more stable than the DRLP construct, which exhibited the largest displacement under high load. Paradoxically, the DRLP construct consistently resulted in the highest degree of implant stress and the least stability. At the fracture interface, the NHLP maintained a stable environment across all loads, with key metrics remaining within a range conducive to bone healing. Conclusion: This finite element analysis demonstrated that the NHLP provides fracture stability while reducing peak implant stress under physiological loading. These findings support the biomechanical feasibility of its pes anserinus-sparing design, providing a strong rationale for further investigation.
- Open Access
- 18 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-10
Preferred screw placement area identified by imaging based quadrant and heatmap analysis for long screw fixation in Ogawa I coracoid process fractures
Ogawa I coracoid process fractures are relatively rare. Surgical fixation requires precise determination of the screw length and direction to avoid iatrogenic injuries. Identifying the preferred screw placement area (PSPA) through imaging techniques is crucial for enhancing surgical safety and stability. This study utilized shoulder computed tomography (CT) data from 100 adult patients, employing three-dimensional (3D) modelling and simulated surgeries to analyze the PSPA for long screw fixation in Ogawa I coracoid process fractures. Scapular Y-view two-dimensional (2D) fluoroscopic images were divided into quadrants. Using scatter plots and heatmap techniques, we identified the PSPA, cautious screw placement area (CSPA), and danger screw placement area (DSPA). Preliminary validation was conducted through a cadaveric bone experiment and 9 clinical cases. The screw tip clusters were primarily distributed in the posterior-lower quadrant of the scapular Y-view images. The red and orange regions on the heatmap indicate the PSPA. The lengths of the longest (L1) and shortest screws (L2) were 53.44 ± 5.37 mm and 40.74 ± 6.02 mm, respectively. Male patients required longer screws, with significant sex differences (P < 0.05). Cadaveric bone experiments and in vivo validation demonstrated that screw placement via the PSPA effectively prevented screw perforation. This imaging study, employing the quadrant method, explored a potential PSPA for long screw fixation in Ogawa I coracoid process fractures. Initial observations from cadaveric and clinical settings suggest that this approach might assist in intraoperative screw orientation and could contribute to a reduced risk of iatrogenic injury.
- 18 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-10
Open AccessPreferred screw placement area identified by imaging based quadrant and heatmap analysis for long screw fixation in Ogawa I coracoid process fractures
Ogawa I coracoid process fractures are relatively rare. Surgical fixation requires precise determination of the screw length and direction to avoid iatrogenic injuries. Identifying the preferred screw placement area (PSPA) through imaging techniques is crucial for enhancing surgical safety and stability. This study utilized shoulder computed tomography (CT) data from 100 adult patients, employing three-dimensional (3D) modelling and simulated surgeries to analyze the PSPA for long screw fixation in Ogawa I coracoid process fractures. Scapular Y-view two-dimensional (2D) fluoroscopic images were divided into quadrants. Using scatter plots and heatmap techniques, we identified the PSPA, cautious screw placement area (CSPA), and danger screw placement area (DSPA). Preliminary validation was conducted through a cadaveric bone experiment and 9 clinical cases. The screw tip clusters were primarily distributed in the posterior-lower quadrant of the scapular Y-view images. The red and orange regions on the heatmap indicate the PSPA. The lengths of the longest (L1) and shortest screws (L2) were 53.44 ± 5.37 mm and 40.74 ± 6.02 mm, respectively. Male patients required longer screws, with significant sex differences (P < 0.05). Cadaveric bone experiments and in vivo validation demonstrated that screw placement via the PSPA effectively prevented screw perforation. This imaging study, employing the quadrant method, explored a potential PSPA for long screw fixation in Ogawa I coracoid process fractures. Initial observations from cadaveric and clinical settings suggest that this approach might assist in intraoperative screw orientation and could contribute to a reduced risk of iatrogenic injury.
- Open Access
- 7 April 2025
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 20 (1) , 1-11
Early outcomes of modified hockey-stick medial plate in the treatment of Schatzker IV-VI tibial plateau fractures: a retrospective controlled study
Schatzker IV–VI tibial plateau fractures usually happen in the weight-bearing part of the knee joint. They are hard to fix with traditional methods because they damage soft tissues and make it hard to get back to normal activities. This study introduces a modified hockey-stick medial plate (mHSMP) designed to improve functional outcomes while reducing surgical complexity. This retrospective study included 40 patients with Schatzker IV-VI tibial plateau fractures (20 in the experimental group treated with the mHSMP and 20 in the control group treated with a traditional medial plate) who were followed up for 12 months. Surgical time, intraoperative blood loss, fracture healing time, postoperative complications, and knee function, as assessed by the Hospital for Special Surgery (HSS) score, were compared between the two groups. Compared with the control group, the experimental group had significantly greater HSS scores at 3 days postsurgery (50.2 ± 1.7 vs. 43.6 ± 1.8, P < 0.001), 3 months (68.2 ± 1.8 vs. 61.7 ± 1.9, P < 0.001), and 6 months (83.2 ± 1.9 vs. 76.7 ± 2.1, P < 0.001). No significant differences were observed between the two groups in terms of surgical time, intraoperative blood loss, fracture healing time, or postoperative complications. Compared with traditional fixation methods, the mHSMP results in superior early functional recovery with comparable safety, providing an effective alternative for treating Schatzker IV-VI tibial plateau fractures.
- 7 April 2025
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 20 (1) , 1-11
Open AccessEarly outcomes of modified hockey-stick medial plate in the treatment of Schatzker IV-VI tibial plateau fractures: a retrospective controlled study
Schatzker IV–VI tibial plateau fractures usually happen in the weight-bearing part of the knee joint. They are hard to fix with traditional methods because they damage soft tissues and make it hard to get back to normal activities. This study introduces a modified hockey-stick medial plate (mHSMP) designed to improve functional outcomes while reducing surgical complexity. This retrospective study included 40 patients with Schatzker IV-VI tibial plateau fractures (20 in the experimental group treated with the mHSMP and 20 in the control group treated with a traditional medial plate) who were followed up for 12 months. Surgical time, intraoperative blood loss, fracture healing time, postoperative complications, and knee function, as assessed by the Hospital for Special Surgery (HSS) score, were compared between the two groups. Compared with the control group, the experimental group had significantly greater HSS scores at 3 days postsurgery (50.2 ± 1.7 vs. 43.6 ± 1.8, P < 0.001), 3 months (68.2 ± 1.8 vs. 61.7 ± 1.9, P < 0.001), and 6 months (83.2 ± 1.9 vs. 76.7 ± 2.1, P < 0.001). No significant differences were observed between the two groups in terms of surgical time, intraoperative blood loss, fracture healing time, or postoperative complications. Compared with traditional fixation methods, the mHSMP results in superior early functional recovery with comparable safety, providing an effective alternative for treating Schatzker IV-VI tibial plateau fractures.
- 1 July 2018
- Vol. 22, 53-62
Comparative study between mini-open TLIF via Wiltse's approach and conventional open TLIF in lumbar degenerative diseases
OBJECTIVE: To compare the clinical effects, operation safety and radiation exposure of mini-open TLIF via Wiltse's approach (MOTLIF) and conventional open TLIF (COTLIF) in the treatment of single-segment lumbar degenerative disease via the prospective control study. PATIENTS AND METHODS: A total of 77 patients were enrolled from November 2012 to July 2014, including 42 patients in the mini-open group (MOTLIF) and 35 patients in the COTLIF group. Oswestry Disability Index (ODI) and Visual Analogue Scale (VAS) scores before operation, operation time, intraoperative blood loss, postoperative drainage volume, blood transfusion rates, postoperative bedridden time, postoperative hospital stays, intraoperative fluoroscopic time, levels of serum creatine phosphokinase (CPK) before operation, 3 days and 1 week after operation, VAS scores before operation, 3 days and 1 week after operation, and ODI and VAS scores in the last follow-up between the two groups were compared. RESULTS: There were significant differences between the two groups in the operation time, intraoperative blood loss, postoperative drainage, blood transfusion rates, postoperative bedridden time, postoperative hospital stays and intraoperative fluoroscopic time; all indicators in MOTLIF group were superior to those in COTLIF group (p0.05). However, 3 days after operation, the level of serum CPK in COTLIF group was increased more significantly than that in MOTLIF group (647.4 +/- 178.6 vs. 467.4 +/- 189.4). There were no differences between the two groups in ODI and VAS scores before operation; ODI score in MOTLIF group in the last follow-up was significantly superior to that in COTLIF group (p>0.05). And VAS scores at 3 days and 1 week after operation and the last follow-up in MOTLIF group were superior to those in COTLIF group (p<0.05). CONCLUSIONS: Compared with the conventional open TLIF, mini-open TLIF via Wiltse's approach using the self-designed operating apparatus is characterized by the convenient operation, small trauma and quick recovery after operation. At the same time, the radiation exposure is lower and long-term follow-up effect is superior. Its short-term and long-term effects in the treatment of lower lumbar degenerative disease are also superior.
- 1 July 2018
- Vol. 22, 53-62
Comparative study between mini-open TLIF via Wiltse's approach and conventional open TLIF in lumbar degenerative diseases
OBJECTIVE: To compare the clinical effects, operation safety and radiation exposure of mini-open TLIF via Wiltse's approach (MOTLIF) and conventional open TLIF (COTLIF) in the treatment of single-segment lumbar degenerative disease via the prospective control study. PATIENTS AND METHODS: A total of 77 patients were enrolled from November 2012 to July 2014, including 42 patients in the mini-open group (MOTLIF) and 35 patients in the COTLIF group. Oswestry Disability Index (ODI) and Visual Analogue Scale (VAS) scores before operation, operation time, intraoperative blood loss, postoperative drainage volume, blood transfusion rates, postoperative bedridden time, postoperative hospital stays, intraoperative fluoroscopic time, levels of serum creatine phosphokinase (CPK) before operation, 3 days and 1 week after operation, VAS scores before operation, 3 days and 1 week after operation, and ODI and VAS scores in the last follow-up between the two groups were compared. RESULTS: There were significant differences between the two groups in the operation time, intraoperative blood loss, postoperative drainage, blood transfusion rates, postoperative bedridden time, postoperative hospital stays and intraoperative fluoroscopic time; all indicators in MOTLIF group were superior to those in COTLIF group (p0.05). However, 3 days after operation, the level of serum CPK in COTLIF group was increased more significantly than that in MOTLIF group (647.4 +/- 178.6 vs. 467.4 +/- 189.4). There were no differences between the two groups in ODI and VAS scores before operation; ODI score in MOTLIF group in the last follow-up was significantly superior to that in COTLIF group (p>0.05). And VAS scores at 3 days and 1 week after operation and the last follow-up in MOTLIF group were superior to those in COTLIF group (p<0.05). CONCLUSIONS: Compared with the conventional open TLIF, mini-open TLIF via Wiltse's approach using the self-designed operating apparatus is characterized by the convenient operation, small trauma and quick recovery after operation. At the same time, the radiation exposure is lower and long-term follow-up effect is superior. Its short-term and long-term effects in the treatment of lower lumbar degenerative disease are also superior.