Brian R. Baker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Brian R. Baker has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Kevin William Plaxco
University of California
3 shared publications Alan J. Heeger
Department of Chemistry and Biochemistry and Department of Physics and Institute for Polymers and Organic Solids, University of California, Santa Barbara, California 93106
2 shared publicationsArica A. Lubin
Department of Chemistry and Biochemistry and Program in BioMolecular Science and Engineering, University of California, Santa Barbara, CA 93106
2 shared publications- Donald P. King
The Pirbright Institute
2 shared publications Rebecca Y. Lai
Department of Chemistry and Biochemistry and Department of Physics and Institute for Polymers and Organic Solids, University of California, Santa Barbara, California 93106
2 shared publications- Alan J. Heeger
Center for Polymers and Organic Solids, University of California at Santa Barbara, Santa Barbara, California 93106-5090, USA
1 shared publication
Latest Publications
- 1 January 2013
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (13) , 3692-3696
On-chip laser-induced DNA dehybridization
Detection of pathogens and relevant genetic markers using their nucleic acid signatures is extremely common due to the inherent specificity genomic sequences provide. One approach for assaying a sample simultaneously for many different targets is the DNA microarray, which consists of several million short nucleic acid sequences (probes) bound to an inexpensive transparent substrate. Typically, complex samples hybridize to the microarray and the pattern of fluorescing probes on the microarray's surface identifies the detected targets. In the case of evolving or newly emergent organisms, a hybridization pattern can occur that differs from any previously known sources. When this happens it can be useful to recover the hybridized DNA from the binding locations of interest for sequencing. Here we present the novel utilization of a focused Infrared (IR) laser to heat user-selected spots on the DNA microarray surface, causing only localized dehybridization and recovery of the desired DNA into an elution buffer where it is available for subsequent amplification or sequencing. The introduction of a focused dehybridization method for spots of interest suppresses the amount of background DNA to be analyzed from downstream processes, and should reduce subsequent sequence assembly errors. This technique could also be applied to high-density protein microarrays where the desire to locally heat spots for release of bound molecules is desired.
- 1 January 2013
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 138 (13) , 3692-3696
On-chip laser-induced DNA dehybridization
Detection of pathogens and relevant genetic markers using their nucleic acid signatures is extremely common due to the inherent specificity genomic sequences provide. One approach for assaying a sample simultaneously for many different targets is the DNA microarray, which consists of several million short nucleic acid sequences (probes) bound to an inexpensive transparent substrate. Typically, complex samples hybridize to the microarray and the pattern of fluorescing probes on the microarray's surface identifies the detected targets. In the case of evolving or newly emergent organisms, a hybridization pattern can occur that differs from any previously known sources. When this happens it can be useful to recover the hybridized DNA from the binding locations of interest for sequencing. Here we present the novel utilization of a focused Infrared (IR) laser to heat user-selected spots on the DNA microarray surface, causing only localized dehybridization and recovery of the desired DNA into an elution buffer where it is available for subsequent amplification or sequencing. The introduction of a focused dehybridization method for spots of interest suppresses the amount of background DNA to be analyzed from downstream processes, and should reduce subsequent sequence assembly errors. This technique could also be applied to high-density protein microarrays where the desire to locally heat spots for release of bound molecules is desired.
- Open Access
- 16 June 2011
- Published by Springer Nature in BMC Bioinformatics
- Vol. 12 (1) , 240
LAVA: An Open-Source Approach To Designing LAMP (Loop-Mediated Isothermal Amplification) DNA Signatures
We developed an extendable open-source Loop-mediated isothermal AMPlification (LAMP) signature design program called LAVA (LAMP Assay Versatile Analysis). LAVA was created in response to limitations of existing LAMP signature programs.
- 16 June 2011
- Published by Springer Nature in BMC Bioinformatics
- Vol. 12 (1) , 240
Open AccessLAVA: An Open-Source Approach To Designing LAMP (Loop-Mediated Isothermal Amplification) DNA Signatures
We developed an extendable open-source Loop-mediated isothermal AMPlification (LAMP) signature design program called LAVA (LAMP Assay Versatile Analysis). LAVA was created in response to limitations of existing LAMP signature programs.
- 21 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (3) , 805-808
Development and Initial Results of a Low Cost, Disposable, Point-of-Care Testing Device for Pathogen Detection
Development of small footprint, disposable, fast, and inexpensive devices for pathogen detection in the field and clinic would benefit human and veterinary medicine by allowing evidence-based responses to future out breaks. We designed and tested an integrated nucleic acid extraction and amplification device employing a loop-mediated isothermal amplification (LAMP) or reverse transcriptase-LAMP assay. Our system provides a screening tool with polymerase-chain-reaction-level sensitivity and specificity for outbreak detection, response, and recovery. Time to result is ~90 min. The device utilizes a swab that collects sample and then transfers it to a disc of cellulose-based nucleic acid binding paper. The disc is positioned within a disposable containment tube with a manual loading port. In order to test for the presence of target pathogens, LAMP reagents are loaded through the tube's port into contact with the sample containing cellulose disc. The reagents then are isothermally heated to 63°C for ~1 h to achieve sequence-specific target nucleic acid amplification. Due to the presence of a colorimetric dye, amplification induces visible color change in the reagents from purple to blue. As initial demonstrations, we detected methicillin resistant Staphylococcus aureus genomic DNA, as well as recombinant and live foot-and-mouth disease virus.
- 21 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (3) , 805-808
Development and Initial Results of a Low Cost, Disposable, Point-of-Care Testing Device for Pathogen Detection
Development of small footprint, disposable, fast, and inexpensive devices for pathogen detection in the field and clinic would benefit human and veterinary medicine by allowing evidence-based responses to future out breaks. We designed and tested an integrated nucleic acid extraction and amplification device employing a loop-mediated isothermal amplification (LAMP) or reverse transcriptase-LAMP assay. Our system provides a screening tool with polymerase-chain-reaction-level sensitivity and specificity for outbreak detection, response, and recovery. Time to result is ~90 min. The device utilizes a swab that collects sample and then transfers it to a disc of cellulose-based nucleic acid binding paper. The disc is positioned within a disposable containment tube with a manual loading port. In order to test for the presence of target pathogens, LAMP reagents are loaded through the tube's port into contact with the sample containing cellulose disc. The reagents then are isothermally heated to 63°C for ~1 h to achieve sequence-specific target nucleic acid amplification. Due to the presence of a colorimetric dye, amplification induces visible color change in the reagents from purple to blue. As initial demonstrations, we detected methicillin resistant Staphylococcus aureus genomic DNA, as well as recombinant and live foot-and-mouth disease virus.
- 4 November 2008
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 8 (12) , 4386-4390
Aptamer-Based SERRS Sensor for Thrombin Detection
We describe an aptamer-based surface enhanced resonance Raman scattering (SERRS) sensor with high sensitivity, specificity, and stability for the detection of a coagulation protein, human α-thrombin. The sensor achieves high sensitivity and a limit of detection of 100 pM by monitoring the SERRS signal change upon the single-step of thrombin binding to immobilized thrombin binding aptamer. The selectivity of the sensor is demonstrated by the specific discrimination of thrombin from other protein analytes. The specific recognition and binding of thrombin by the thrombin binding aptamer is essential to the mechanism of the aptamer-based sensor, as shown through measurements using negative control oligonucleotides. In addition, the sensor can detect 1 nM thrombin in the presence of complex biofluids, such as 10% fetal calf serum, demonstrating that the immobilized, 5′-capped, 3′-capped aptamer is sufficiently robust for clinical diagnostic applications. Furthermore, the proposed sensor may be implemented for multiplexed detection using different aptamer-Raman probe complexes.
- 4 November 2008
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 8 (12) , 4386-4390
Aptamer-Based SERRS Sensor for Thrombin Detection
We describe an aptamer-based surface enhanced resonance Raman scattering (SERRS) sensor with high sensitivity, specificity, and stability for the detection of a coagulation protein, human α-thrombin. The sensor achieves high sensitivity and a limit of detection of 100 pM by monitoring the SERRS signal change upon the single-step of thrombin binding to immobilized thrombin binding aptamer. The selectivity of the sensor is demonstrated by the specific discrimination of thrombin from other protein analytes. The specific recognition and binding of thrombin by the thrombin binding aptamer is essential to the mechanism of the aptamer-based sensor, as shown through measurements using negative control oligonucleotides. In addition, the sensor can detect 1 nM thrombin in the presence of complex biofluids, such as 10% fetal calf serum, demonstrating that the immobilized, 5′-capped, 3′-capped aptamer is sufficiently robust for clinical diagnostic applications. Furthermore, the proposed sensor may be implemented for multiplexed detection using different aptamer-Raman probe complexes.
- 1 March 2008
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 46 (3) , 1081-1089
Diagnostic Evaluation of Multiplexed Reverse Transcription-PCR Microsphere Array Assay for Detection of Foot-and-Mouth and Look-Alike Disease Viruses
A high-throughput multiplexed assay was developed for the differential laboratory detection of foot-and-mouth disease virus (FMDV) from viruses that cause clinically similar diseases of livestock. This assay simultaneously screens for five RNA and two DNA viruses by using multiplexed reverse transcription-PCR (mRT-PCR) amplification coupled with a microsphere hybridization array and flow-cytometric detection. Two of the 17 primer-probe sets included in this multiplex assay were adopted from previously characterized real-time RT-PCR (rRT-PCR) assays for FMDV. The diagnostic accuracy of the mRT-PCR assay was evaluated using 287 field samples, including 247 samples (213 true-positive samples and 35 true-negative samples) from suspected cases of foot-and-mouth disease collected from 65 countries between 1965 and 2006 and 39 true-negative samples collected from healthy animals. The mRT-PCR assay results were compared to those of two singleplex rRT-PCR assays, using virus isolation with antigen enzyme-linked immunosorbent assays as the reference method. The diagnostic sensitivity of the mRT-PCR assay for FMDV was 93.9% (95% confidence interval [CI], 89.8 to 96.4%), and the sensitivity was 98.1% (95% CI, 95.3 to 99.3%) for the two singleplex rRT-PCR assays used in combination. In addition, the assay could reliably differentiate between FMDV and other vesicular viruses, such as swine vesicular disease virus and vesicular exanthema of swine virus. Interestingly, the mRT-PCR detected parapoxvirus ( n = 2) and bovine viral diarrhea virus ( n = 2) in clinical samples, demonstrating the screening potential of this mRT-PCR assay to identify viruses in FMDV-negative material not previously recognized by using focused single-target rRT-PCR assays.
- 1 March 2008
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 46 (3) , 1081-1089
Diagnostic Evaluation of Multiplexed Reverse Transcription-PCR Microsphere Array Assay for Detection of Foot-and-Mouth and Look-Alike Disease Viruses
A high-throughput multiplexed assay was developed for the differential laboratory detection of foot-and-mouth disease virus (FMDV) from viruses that cause clinically similar diseases of livestock. This assay simultaneously screens for five RNA and two DNA viruses by using multiplexed reverse transcription-PCR (mRT-PCR) amplification coupled with a microsphere hybridization array and flow-cytometric detection. Two of the 17 primer-probe sets included in this multiplex assay were adopted from previously characterized real-time RT-PCR (rRT-PCR) assays for FMDV. The diagnostic accuracy of the mRT-PCR assay was evaluated using 287 field samples, including 247 samples (213 true-positive samples and 35 true-negative samples) from suspected cases of foot-and-mouth disease collected from 65 countries between 1965 and 2006 and 39 true-negative samples collected from healthy animals. The mRT-PCR assay results were compared to those of two singleplex rRT-PCR assays, using virus isolation with antigen enzyme-linked immunosorbent assays as the reference method. The diagnostic sensitivity of the mRT-PCR assay for FMDV was 93.9% (95% confidence interval [CI], 89.8 to 96.4%), and the sensitivity was 98.1% (95% CI, 95.3 to 99.3%) for the two singleplex rRT-PCR assays used in combination. In addition, the assay could reliably differentiate between FMDV and other vesicular viruses, such as swine vesicular disease virus and vesicular exanthema of swine virus. Interestingly, the mRT-PCR detected parapoxvirus ( n = 2) and bovine viral diarrhea virus ( n = 2) in clinical samples, demonstrating the screening potential of this mRT-PCR assay to identify viruses in FMDV-negative material not previously recognized by using focused single-target rRT-PCR assays.
- Open Access
- 7 November 2006
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 103 (45) , 16677-16680
Single-step electronic detection of femtomolar DNA by target-induced strand displacement in an electrode-bound duplex
We report a signal-on, electronic DNA (E-DNA) sensor that is label-free and achieves a subpicomolar detection limit. The sensor, which is based on a target-induced strand displacement mechanism, is composed of a “capture probe” attached by its 5′ terminus to a gold electrode and a 5′ methylene blue-modified “signaling probe” that is complementary at both its 3′ and 5′ termini to the capture probe. In the absence of target, hybridization between the capture and signaling probes minimizes contact between the methylene blue and electrode surface, limiting the observed redox current. Target hybridization displaces the 5′ end of the signaling probe, generating a short, flexible single-stranded DNA element and producing up to a 7-fold increase in redox current. The observed signal gain is sufficient to achieve a demonstrated (not extrapolated) detection limit of 400 fM, which is among the best reported for single-step electronic DNA detection. Moreover, because sensor fabrication is straightforward, the approach appears to provide a ready alternative to the more cumbersome femtomolar electrochemical assays described to date.
- 7 November 2006
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 103 (45) , 16677-16680
Open AccessSingle-step electronic detection of femtomolar DNA by target-induced strand displacement in an electrode-bound duplex
We report a signal-on, electronic DNA (E-DNA) sensor that is label-free and achieves a subpicomolar detection limit. The sensor, which is based on a target-induced strand displacement mechanism, is composed of a “capture probe” attached by its 5′ terminus to a gold electrode and a 5′ methylene blue-modified “signaling probe” that is complementary at both its 3′ and 5′ termini to the capture probe. In the absence of target, hybridization between the capture and signaling probes minimizes contact between the methylene blue and electrode surface, limiting the observed redox current. Target hybridization displaces the 5′ end of the signaling probe, generating a short, flexible single-stranded DNA element and producing up to a 7-fold increase in redox current. The observed signal gain is sufficient to achieve a demonstrated (not extrapolated) detection limit of 400 fM, which is among the best reported for single-step electronic DNA detection. Moreover, because sensor fabrication is straightforward, the approach appears to provide a ready alternative to the more cumbersome femtomolar electrochemical assays described to date.
- 13 July 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (16) , 5671-5677
Sequence-Specific, Electronic Detection of Oligonucleotides in Blood, Soil, and Foodstuffs with the Reagentless, Reusable E-DNA Sensor
The ability to detect specific oligonucleotides in complex, contaminant-ridden samples, without the use of exogenous reagents and using a reusable, fully electronic platform could revolutionize the detection of pathogens in the clinic and in the field. Here, we characterize a label-free, electronic sensor, termed E-DNA, for its ability to simultaneously meet these challenging demands. We find that because signal generation is coupled to a hybridization-linked conformational change, rather than to only adsorption to the sensor surface, E-DNA is selective enough to detect oligonucleotides in complex, multicomponent samples, such as blood serum and soil. Moreover, E-DNA signaling is monotonically related to target complementarity, allowing the sensor to discriminate between mismatched targets: we readily detect the complementary 17-base target against a 50 000-fold excess of genomic DNA, can distinguish a three-base mismatch from perfect target directly in blood serum, and under ideal conditions, observe statistically significant differences between single-base mismatches. Finally, because the sensing components are linked to the electrode surface, E-DNA is reusable: a 30-s room temperature wash recovers >99% of the sensor signal. This work further supports the utility of E-DNA as a rapid, specific, and convenient method for the detection of DNA and RNA sequences.
- 13 July 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (16) , 5671-5677
Sequence-Specific, Electronic Detection of Oligonucleotides in Blood, Soil, and Foodstuffs with the Reagentless, Reusable E-DNA Sensor
The ability to detect specific oligonucleotides in complex, contaminant-ridden samples, without the use of exogenous reagents and using a reusable, fully electronic platform could revolutionize the detection of pathogens in the clinic and in the field. Here, we characterize a label-free, electronic sensor, termed E-DNA, for its ability to simultaneously meet these challenging demands. We find that because signal generation is coupled to a hybridization-linked conformational change, rather than to only adsorption to the sensor surface, E-DNA is selective enough to detect oligonucleotides in complex, multicomponent samples, such as blood serum and soil. Moreover, E-DNA signaling is monotonically related to target complementarity, allowing the sensor to discriminate between mismatched targets: we readily detect the complementary 17-base target against a 50 000-fold excess of genomic DNA, can distinguish a three-base mismatch from perfect target directly in blood serum, and under ideal conditions, observe statistically significant differences between single-base mismatches. Finally, because the sensing components are linked to the electrode surface, E-DNA is reusable: a 30-s room temperature wash recovers >99% of the sensor signal. This work further supports the utility of E-DNA as a rapid, specific, and convenient method for the detection of DNA and RNA sequences.
- Top Cited Papers
- 18 February 2006
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 128 (10) , 3138-3139
An Electronic, Aptamer-Based Small-Molecule Sensor for the Rapid, Label-Free Detection of Cocaine in Adulterated Samples and Biological Fluids
Whereas spectroscopic and chromatographic techniques for the detection of small organic molecules have achieved impressive results, these methods are generally slow and cumbersome, and thus the development of a general means for the real-time, electronic detection of such targets remains a compelling goal. Here we demonstrate a potentially general, label-free electronic method for the detection of small-molecule targets by building a rapid, reagentless biosensor for the detection of cocaine. The sensor, based on the electrochemical interrogation of a structure-switching aptamer, specifically detects micromolar cocaine in seconds. Because signal generation is based on binding-induced folding, the sensor is highly selective and works directly in blood serum and in the presence of commonly employed interferents and cutting agents, and because all of the sensor components are covalently attached to the electrode surface, the sensor is also reusable: we achieve >99% signal regeneration upon a brief, room temperature aqueous wash. Given recent advances in the generation of highly specific aptamers, this detection platform may be readily adapted for the detection of other small molecules of a wide range of clinically and environmentally relevant small molecules.
- 18 February 2006
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 128 (10) , 3138-3139
Top Cited PapersAn Electronic, Aptamer-Based Small-Molecule Sensor for the Rapid, Label-Free Detection of Cocaine in Adulterated Samples and Biological Fluids
Whereas spectroscopic and chromatographic techniques for the detection of small organic molecules have achieved impressive results, these methods are generally slow and cumbersome, and thus the development of a general means for the real-time, electronic detection of such targets remains a compelling goal. Here we demonstrate a potentially general, label-free electronic method for the detection of small-molecule targets by building a rapid, reagentless biosensor for the detection of cocaine. The sensor, based on the electrochemical interrogation of a structure-switching aptamer, specifically detects micromolar cocaine in seconds. Because signal generation is based on binding-induced folding, the sensor is highly selective and works directly in blood serum and in the presence of commonly employed interferents and cutting agents, and because all of the sensor components are covalently attached to the electrode surface, the sensor is also reusable: we achieve >99% signal regeneration upon a brief, room temperature aqueous wash. Given recent advances in the generation of highly specific aptamers, this detection platform may be readily adapted for the detection of other small molecules of a wide range of clinically and environmentally relevant small molecules.
- 24 October 2003
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 126, 209-222
g-Factor analysis of protein secondary structure in solutions and thin films
The biological activity of proteins is structure dependent. In this discussion, we describe development of g-factor analysis for characterizing the secondary structure of proteins in solutions and films. In g-factor analysis, experimental circular dichroism (CD) and UV absorbance spectra are converted to dimensionless g-factor spectra by dividing the differential absorbance of circularly polarized light (AL − AR) by the UV absorbance (A) at each wavelength. The spectra can be deconvolved and the secondary structure estimated without information on the protein molecular weight, sample concentration, or sample path length. We have refined g-factor spectral acquisition and deconvolution parameters to improve the precision and accuracy of experimental g-factor spectra and the subsequent secondary structure estimations. In general, slower scan rates and longer response times are required to obtain high quality g-factor spectra than to obtain ordinary CD spectra, particularly for data at wavelengths longer than 230 nm. The spectral acquisition and deconvolution procedures have been validated for aqueous bovine serum albumin (BSA) and poly(L-proline). The secondary structures of fibronectin and laminin in buffer solutions are predicted. When BSA and poly(L-proline) form films on quartz, their secondary structures change significantly: 13% for BSA and 32% for poly(L-proline). By contrast, the secondary structure of fibronectin is the same in solution and films. The g-factor method is an easy, rapid, accurate and precise method for determining secondary structure and structural changes in protein solutions and films. Potential applications range from proteomics and structure-based drug discovery, to the design and fabrication of biosensors, biomaterials and biofluidic devices.
- 24 October 2003
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 126, 209-222
g-Factor analysis of protein secondary structure in solutions and thin films
The biological activity of proteins is structure dependent. In this discussion, we describe development of g-factor analysis for characterizing the secondary structure of proteins in solutions and films. In g-factor analysis, experimental circular dichroism (CD) and UV absorbance spectra are converted to dimensionless g-factor spectra by dividing the differential absorbance of circularly polarized light (AL − AR) by the UV absorbance (A) at each wavelength. The spectra can be deconvolved and the secondary structure estimated without information on the protein molecular weight, sample concentration, or sample path length. We have refined g-factor spectral acquisition and deconvolution parameters to improve the precision and accuracy of experimental g-factor spectra and the subsequent secondary structure estimations. In general, slower scan rates and longer response times are required to obtain high quality g-factor spectra than to obtain ordinary CD spectra, particularly for data at wavelengths longer than 230 nm. The spectral acquisition and deconvolution procedures have been validated for aqueous bovine serum albumin (BSA) and poly(L-proline). The secondary structures of fibronectin and laminin in buffer solutions are predicted. When BSA and poly(L-proline) form films on quartz, their secondary structures change significantly: 13% for BSA and 32% for poly(L-proline). By contrast, the secondary structure of fibronectin is the same in solution and films. The g-factor method is an easy, rapid, accurate and precise method for determining secondary structure and structural changes in protein solutions and films. Potential applications range from proteomics and structure-based drug discovery, to the design and fabrication of biosensors, biomaterials and biofluidic devices.