EIElena V. Ivanova

Elena V. Ivanova

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Elena V. Ivanova has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Supplementary Figures 1-12 from Reactivation of ERK Signaling Causes Resistance to EGFR Kinase Inhibitors

    by Dalia Ercan, Chunxiao Xu, Masahiko Yanagita, Calixte S. Monast, Christine A. Pratilas, Joan Montero, Mohit Butaney, Takeshi Shimamura, Lynette Sholl, Elena V. Ivanova, et al.

  • Open Access

    Table S1-S3; Figure S1-S13 from BET Bromodomain Inhibition Cooperates with PD-1 Blockade to Facilitate Antitumor Response in Kras-Mutant Non–Small Cell Lung Cancer

    by Dennis O. Adeegbe, Shengwu Liu, Maureen M. Hattersley, Michaela Bowden, Chensheng W. Zhou, Shuai Li, Raven Vlahos, Michael Grondine, Igor Dolgalev, Elena V. Ivanova, et al.

    Supplementary Table S1. Detailed information about the antibodies used. Supplementary Table S2. Proportions of listed immune cell subsets in the tumor microenvironment of NSCLC GEMs were evaluated by FACS utilizing indicated lineage markers and proteins. Supplementary Table S3. Tumor cells from treated KP mice were subjected to RNA-sequencing. Supplementary Figure S1. Kinetics of tumor growth in KP mice treated with anti-PD-1. Supplementary Figure S2. Immune cell proportions in the tumors of treated KP mice. Supplementary Figure S3. PD-1 is prominently expressed on tumor-infiltrating T cells in GEMM of NSCLC. Supplementary Figure S4. Decreased expression of PD-1 and CTLA-4 on tumor-infiltrating CD4+ T cells under JQ1 treatment. Supplementary Figure S5. Increased expression of MHC class I on tumor-infiltrating tumor-associated macrophages (TAMs). Supplementary Figure S6. Combination of JQ1 and PD-1 blockade evokes unique genomic genomic changes in tumors of treated KP mice. Supplementary Figure S7. Overall survival of tumor-bearing nude mice treated with JQ1 or anti-PD-1. Supplementary Figure S8. JQ1 and/or anti-PD-1 treatment facilitated enhanced effector function of tumor-infiltrating CD8+ T cells. Supplementary Figure S9. Combination of JQ1 and α-PD-1 did not have substantial deleterious effects on tumor-associated T cells. Supplementary Figure S10. Tumor-infiltrating KLRG1+ CD4+Foxp3+ Tregs exhibit a highly activated profile but resemble natural peripheral Tregs. Supplementary Figure S11. Tumor-infiltrating KLRG1+ CD4+Foxp3+ Tregs are not derived from CD4+CD25- cells. Supplementary Figure S12. Tumor-associated KLRG1+ Tregs express higher CTLA-4 and demonstrate enhanced suppressive function. Supplementary Figure S13. Decreased expression of Treg signature proteins and Bcl-2 on tumor-infiltrating KLRG1+ Treg subset under JQ1 treatment.

  • Open Access

    Evaluation of the efficacy and safety of navigational combined laser treatment in combination with antiangiogenic therapy in macular edema due to the branch retinal vein occlusion

    by Pavel L. Volodin, Moscow Fyodorov Eye Microsurgery Federal State Institution, Elena V. Ivanova, Yuliya I. Kukharskaya

    Источник <a href="https://eyepress.ru/sbornik.aspx?11155" class="s

  • Justification of measures to protect against exposure nicotine-containing products in enclosed spaces

    by Irek Sh. Iakubova, Ekaterina V. Zaritskaya, Лилия Абулняимовна Аликбаева, Elena V. Ivanova, Anna V. Suvorova

    Introduction. The introduction of amendments and additions to the anti-smoking Federal Law No. 15-FZ of 23.02.2013 in 2020 contributed to the cardinal revision of the name of this law and the introduction of a ban on consumption of any nicotine-containing products in public places. There are no separate, specially allocated isolated premises provided for the consumption of tobacco products and other types of nicotine-containing products by law, even though specially conducted studies have shown significantly different levels of additional inhalation risk arising from air pollution when consuming tobacco products and electronic nicotine delivery systems or heating tobacco. The aim of the study: based on experimental data, to justify the multiplicity of air exchange in unique isolated rooms designed to protect against the effects of ambient tobacco smoke, the consequences of tobacco consumption or nicotine-containing products. Materials and methods. The study was subject to 3 types of nicotine-containing products: tobacco cigarettes (cigarettes), an electronic nicotine delivery system (ENDS) and an electronic tobacco heating system (ETHS). In the course of the study were carried out: a series of experiments on the consumption of nicotine-containing products in various ways in a specially equipped indoor room, air sampling and laboratory studies were performed, the gross and specific emissions of chemicals entering the air environment from one unit of production per hour were calculated, the selection of priority chemicals for calculating the air removed from the room when using nicotine-containing products of each type was carried out, the necessary level of air exchange of premises was calculated, intended for the consumption of tobacco or nicotine. Results. The indoor air quality assessment showed that the main components of the gross intake into the air environment are suspended particles and carbon monoxide when smoking cigarettes. However, taking into account the values of the maximum permissible concentrations, the most significant contribution to the integral indicator is made by acetaldehyde and suspended particles PM10 and PM2.5. Using ENDS, the most significant pollutants were acetaldehyde and carbon monoxide, using ETHS - acetaldehyde and suspended particles PM10 and PM2.5. For all the investigation types of products, the priority substance for calculating the removed air is acetaldehyde, its share in the structure of all detected pollutants was: for cigarettes - 56.27%, for ENDS - 62.7%, for ETHS - 82.51%, in connection with which its specific values can be used to calculate the consumption of the removed air when modelling a specially allocated room intended for the consumption of tobacco products and other types of nicotine-containing products. Conclusion. The obtained findings demonstrated an obvious, more than 10-fold difference in the requirements for air exchange of premises intended for cigarette smoking and premises intended for the consumption of ENDS or ETHS, at the same intensity of consumption. Therefore, when organizing specially designated places for smoking or the consumption of nicotine-containing products, it is advisable to separate them depending on the type of products consumed: tobacco smoking separately, ENDS and ETHS consumption separately.

  • Open Access

    Identification of Priority Air Pollutants in Confined Spaces

    by О. Л. Мaрковa, Ev Zaritskaya, Mn Kir’yAnova, Е. В. Иванова, М. Н. Кирьяновa

    Introduction: Owing to the rapid development of digital technologies, most people nowadays are working indoors while using no machinery or equipment and being unexposed to volatile industrial chemicals. Yet, people staying inside for too long often complain of poor indoor air quality and microclimate. Our objective was to study air pollutants in a simulation experiment with continuous human occupancy inside unventilated confined spaces. Materials and methods: Up-to-date sensitive analytical techniques, such as photoionization, laser nephelometry, gas-phase chemiluminescence, spectrophotometry, high-performance liquid chromatography with diode array detection (HPLCDAD) and gas chromatography–mass spectrometry (GC-MS), were used to determine indoor air pollutants. Results: We compared changes in airborne concentrations of nitrogen oxides, prop-2-enenitrile, acetaldehyde, benzene, but-2-enal, airborne particulate matter (PM2,5 and PM10), methylbenzene, 2-methylbuta-1,3-diene, formaldehyde, prop-2-en-1-al, carbon oxide and dioxide following 1.5, 3.0, and 4.5 hours of stay of volunteers in a 15.9 m2 room (4.0 m2 per person; a 2.55 m ceiling height) against background levels. The established human occupancy-related priority pollutants included acetaldehyde, formaldehyde, prop-2-en-1-al, and carbon dioxide. Laboratory testing showed the presence of 83 volatile and semivolatile organic chemicals in the unventilated room, among which aromatic hydrocarbons, esters and aldehydes prevailed. Conclusion: Our findings could be useful for designing ventilation systems in confined spaces and optimizing the workbreak schedule during the working hours.


  • Open Access

    WAYS FOR MINIMIZING THE NEGATIVE EFFECT OF TOBACCO AEROSOL COMPONENTS DURING PASSIVE SMOKING

    by Olga L. Markova, M. N. Kiryanova, E. V. Ivanova, E. V. Zaritskaya

    Introduction. There are reported air quality assessment findings in enclosed spaces in experimental conditions using two kinds of nicotine-containing products - cigarettes and electronic nicotine delivery system (ENDS), seem to be the most common types of smoking. Мaterial and Methods. In the process of the experiment concentrations of tobacco aerosol components, i.e.: 12 chemicals and two aerosols were measured. Studies were carried out in isolated rooms under monitored microclimate parameters and uniform air mixing. Groups of volunteers using cigarettes or electronic nicotine delivery systems and the control non-smoker group participated in the study; everybody gave their informed consent for participation in the experiment. Control of background indices for comparison of air quality in rooms where tobacco products were being smoked was carried out. Results. Our studies allowing to identify chemicals evolving into the air of enclosed rooms where “PARLAMENT Aqua Blue” cigarettes were smoked or electronic tobacco delivery systems “CRICKET Classic 3.0” were used, to estimate total amount of chemicals in air. Prevailing chemicals affecting human health, which can be recommended for the use in calculations and air study of enclosed rooms exposed to tobacco aerosol, were identified. Estimated values of adverse chemical concentrations, air flow and air expenditure rate, resulting from experimental data allow designing ventilation system with regard to hygienic requirements based on maximum allowable concentration values for atmospheric air. Conclusions. Suggested recommendations on calculation of ventilation parameters to produce comfortable human environment in passive smoking conditions will improve air quality in public buildings.


  • HYGIENIC ASSESSMENT OF AIR STATE IN LEAD-ACID ACCUMULATOR PRODUCTION AT DIFFERENT STAGES OF PRODUCTION UPDATING

    by O L Markova, E V Ivanova, M N Kir'Yanova, V P Plekhanov

    Hygienic assessment of air pollution in workrooms for large lead-acid accumulator production is given. Studies were carried out in various conditions: in shops with outdated manufacturing equipment, after ventilation system reconstruction, and in shops with up-to-date production lines and ventilation systems. For workshop air assessment chemical analyses of air samples to detect lead and sulphuric acid aerosols were carried out at workplaces of major lead-acid accumulator production jobs. Approved techniques were used: atomic absorption to measure lead and photometric method to determine sulphuric acid concentrations in workplace air and in industrial emissions. The effectiveness of used ventilation equipment after its large-scale modernization is evaluated in accordance with current regulations. Sanitary-and-hygienic characteristics of local exhaust systems were evaluated according to economy index. Based on testing of dust-and-gas collecting plants, purification efficiency of extracted air was determined. Meteorological parameters (temperature, humidity, and air speed) in workplace areas were measured in the process of the study. The problem of further improvement of engineering decisions on removal of polluted air from workshops is still an area of current concern, as lead concentrations in workplace air remain high in spite of modifications in technological processes and various sanitary-and-engineering measures being taken.

    • 1 January 2015
      • No. 2,p. 5-8

    [Contemporary solutions for better air quality at electric welders workplace].

    by O L Markova, E V Ivanova

    The article deals with hygienic evaluation of electric welder's workplace, concerning chemical factor, with technical solutions on organization of supply-and-exhaust ventilation and methods to improve air quality in various welding tasks.