E.A. Skridlevskaya
Research Subjects
E.A. Skridlevskaya has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
A Margolina
1 shared publication- A.L. Muzychin
Kalinin Republic Clinical Hospital
1 shared publication A.N. Dzundzya
Sechenov First Moscow State Medical University
1 shared publication- Alisher Makkamdzhanovich Ismailbaev
Sechenov First Moscow State Medical University
1 shared publication - Boris M. Tlisov
Federal State Autonomous Educational Institution of Higher Education I.M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation (Sechenov University)
1 shared publication - I. A. Plakhotnikov
Kalinin Republic Clinical Hospital
1 shared publication
Latest Publications
- 18 September 2025
- Published by Media Sphere Publishing Group in Russian Cardiology Bulletin
- Vol. 20 (3)
Clinical course and comparative analysis of intraoperative visualization in surgical treatment of blind gunshot wounds of the heart
Introduction. Gunshot wound of the heart is a severe surgical pathology with battlefield mortality rate of up to 80%. The authors analyzed clinical course and intraoperative visualization in surgical treatment of blind gunshot wounds of the heart. Material and methods. A retrospective cohort study included 27 patients. Preoperatively, localization of foreign body was determined using echocardiography, chest X-ray and/or computed tomography. Intraoperatively, real-time X-ray imaging (2D C-arc) was performed in group 1 (n=17), and transesophageal echocardiography (TEE) was performed in group 2 (n=10). Results. The most common concomitant injuries were soft tissue (81.5%) and lung (70.4%) lesions, and the entry wound was localized on the chest wall surface. In 14.8% of cases, the entry wound was detected in other areas. Foreign bodies were detected deep in the myocardium of the left or right ventricles in 70.4% of cases. In all cases, the initially determined foreign body localization was confirmed intraoperatively (TEE or 2D C-arc). There were no significant between-group differences depending on the method of intraoperative foreign body diagnostics regarding intraoperative and early postoperative parameters. There were no postoperative complications or mortality. In 3 cases of the 1st group, foreign body migration from the right ventricle was recorded (1 case — pulmonary artery, 2 cases — hepatic vein). Conclusion. Preoperative localization of foreign body in the heart coincides with intraoperative TEE or X-ray (2D-C-arc) data in 100% of cases. The risk of intraoperative migration is 11%, and all cases are associated with baseline localization in the right ventricle. C-arc for angiography is necessary in the operating theater due to the risk of foreign body migration in blind gunshot wounds of the heart.
- 18 September 2025
- Published by Media Sphere Publishing Group in Russian Cardiology Bulletin
- Vol. 20 (3)
Clinical course and comparative analysis of intraoperative visualization in surgical treatment of blind gunshot wounds of the heart
Introduction. Gunshot wound of the heart is a severe surgical pathology with battlefield mortality rate of up to 80%. The authors analyzed clinical course and intraoperative visualization in surgical treatment of blind gunshot wounds of the heart. Material and methods. A retrospective cohort study included 27 patients. Preoperatively, localization of foreign body was determined using echocardiography, chest X-ray and/or computed tomography. Intraoperatively, real-time X-ray imaging (2D C-arc) was performed in group 1 (n=17), and transesophageal echocardiography (TEE) was performed in group 2 (n=10). Results. The most common concomitant injuries were soft tissue (81.5%) and lung (70.4%) lesions, and the entry wound was localized on the chest wall surface. In 14.8% of cases, the entry wound was detected in other areas. Foreign bodies were detected deep in the myocardium of the left or right ventricles in 70.4% of cases. In all cases, the initially determined foreign body localization was confirmed intraoperatively (TEE or 2D C-arc). There were no significant between-group differences depending on the method of intraoperative foreign body diagnostics regarding intraoperative and early postoperative parameters. There were no postoperative complications or mortality. In 3 cases of the 1st group, foreign body migration from the right ventricle was recorded (1 case — pulmonary artery, 2 cases — hepatic vein). Conclusion. Preoperative localization of foreign body in the heart coincides with intraoperative TEE or X-ray (2D-C-arc) data in 100% of cases. The risk of intraoperative migration is 11%, and all cases are associated with baseline localization in the right ventricle. C-arc for angiography is necessary in the operating theater due to the risk of foreign body migration in blind gunshot wounds of the heart.
- 14 April 2025
- Published by Media Sphere Publishing Group in Russian Cardiology Bulletin
- Vol. 20 (1)
Russian conduit: a new approach in aortic root and ascending aortic surgery. Immediate and mid-term results in a single center
Background. There was a trend towards valve-sparing techniques in aortic root surgery in recent decades. This approach can significantly improve the quality of life and do not require anticoagulation. There is a question on surgical strategy for patients with native aortic leaflets not suitable for reconstruction. We describe an alternative technique of aortic root replacement with certain advantages in mid-term period compared to standard Bio Bentall procedure. Material and methods. The study included 50 patients who underwent surgery for aortic root and ascending aorta lesions between 2014 and 2022. Mean follow-up was 31.0±17.9 months in the group «Russian conduit» and 39.2±22.7 months in the group 2 «BioBentall» (p=0.159). In the 1st group, patients (n=28) underwent a combined Bentall-De Bono procedure and aortic valve neocuspidization with autologous pericardium. In the 2nd group (n=22), surgery was performed using synthetic composite conduit containing biological aortic root stented prosthesis. Results. In the 1st group, there were no conversions to standard Bentall or BioBentall procedure. Cumulative freedom from MACE (delayed all-cause mortality, acute myocardial infarction, stroke, infective endocarditis) after 12, 24, and 48 months was similar (92.59±5.04% versus 100% (p=0.367), 88.7±6.1% versus 93.3±6.4% (p=0.534) and 88.7±6.1% versus 86.7±8.8% (p=0.864)). Freedom from redo surgeries throughout 48 months was 92.59±5.04% and 92.3±7.4%, respectively (p=0.734). Indexed effective orifice area in mid-term period was significantly larger in the 1st group (1.36±0.23 versus 0.93±0.1 cm2, p<0.01). Conclusion. Aortic root and ascending aortic replacement using Russian conduit technique demonstrates comparable results regarding freedom from redo surgeries compared to standard BioBentall technique and better hemodynamic parameters (mean pressure gradient and effective orifice area) in mid-term period. This approach may be successfully used for aortic root disease if reconstruction of native cusps is not possible.
- 14 April 2025
- Published by Media Sphere Publishing Group in Russian Cardiology Bulletin
- Vol. 20 (1)
Russian conduit: a new approach in aortic root and ascending aortic surgery. Immediate and mid-term results in a single center
Background. There was a trend towards valve-sparing techniques in aortic root surgery in recent decades. This approach can significantly improve the quality of life and do not require anticoagulation. There is a question on surgical strategy for patients with native aortic leaflets not suitable for reconstruction. We describe an alternative technique of aortic root replacement with certain advantages in mid-term period compared to standard Bio Bentall procedure. Material and methods. The study included 50 patients who underwent surgery for aortic root and ascending aorta lesions between 2014 and 2022. Mean follow-up was 31.0±17.9 months in the group «Russian conduit» and 39.2±22.7 months in the group 2 «BioBentall» (p=0.159). In the 1st group, patients (n=28) underwent a combined Bentall-De Bono procedure and aortic valve neocuspidization with autologous pericardium. In the 2nd group (n=22), surgery was performed using synthetic composite conduit containing biological aortic root stented prosthesis. Results. In the 1st group, there were no conversions to standard Bentall or BioBentall procedure. Cumulative freedom from MACE (delayed all-cause mortality, acute myocardial infarction, stroke, infective endocarditis) after 12, 24, and 48 months was similar (92.59±5.04% versus 100% (p=0.367), 88.7±6.1% versus 93.3±6.4% (p=0.534) and 88.7±6.1% versus 86.7±8.8% (p=0.864)). Freedom from redo surgeries throughout 48 months was 92.59±5.04% and 92.3±7.4%, respectively (p=0.734). Indexed effective orifice area in mid-term period was significantly larger in the 1st group (1.36±0.23 versus 0.93±0.1 cm2, p<0.01). Conclusion. Aortic root and ascending aortic replacement using Russian conduit technique demonstrates comparable results regarding freedom from redo surgeries compared to standard BioBentall technique and better hemodynamic parameters (mean pressure gradient and effective orifice area) in mid-term period. This approach may be successfully used for aortic root disease if reconstruction of native cusps is not possible.
- 1 August 2001
- Vol. 42 (4) , 505-8
Isolated replacement of the mitral leaflets and "Mercedes"-plastics of the giant left atrium: surgery for patients with left ventricle dysfunction and left atrium enlargement.
The main goal of the present surgery is to develop a new complex of surgical procedures for patients with long-standing mitral valve incompetence, severe left atrium (LA) and left ventricle (LV) enlargement (secondary cardiomyopathy). Seven patients were operated on using a new technique. Normal LA shape and size were restored by symmetrical "Mercedes"-plastics of the posterior LA wall. Isolated strut chordae sparing mitral leaflets replacement (SChS-MLR) was performed for preserving annular-LV interaction and biomechanics of the LV contraction. In mitral position we implanted bileaflets Carbomedics (USA) prosthesis (in 6 patients) and a tilting disc MIKC prosthesis (Russia). Additionally RA plastics and TV De Vega plastics were performed in 4 patients. Diastolic and systolic functions of the LV, the size of the LA were under TEE and 2D ECHO controls. All the patients were discharged from the hospital. After the operation the needs for inotropic support were minimal. We did not see any local LV wall motion abnormalities. The end diastolic volume and long-axis dimension of the LV did not have any tendency to grow. New surgical technique of isolated SChS-MLR together with the symmetrical restoration of the LA shape and size can be equivalent to reconstructive mitral valve surgery from the hemodynamical point of view and allows us to standardize the surgical technique for those patients with significant left heart enlargement.
- 1 August 2001
- Vol. 42 (4) , 505-8
Isolated replacement of the mitral leaflets and "Mercedes"-plastics of the giant left atrium: surgery for patients with left ventricle dysfunction and left atrium enlargement.
The main goal of the present surgery is to develop a new complex of surgical procedures for patients with long-standing mitral valve incompetence, severe left atrium (LA) and left ventricle (LV) enlargement (secondary cardiomyopathy). Seven patients were operated on using a new technique. Normal LA shape and size were restored by symmetrical "Mercedes"-plastics of the posterior LA wall. Isolated strut chordae sparing mitral leaflets replacement (SChS-MLR) was performed for preserving annular-LV interaction and biomechanics of the LV contraction. In mitral position we implanted bileaflets Carbomedics (USA) prosthesis (in 6 patients) and a tilting disc MIKC prosthesis (Russia). Additionally RA plastics and TV De Vega plastics were performed in 4 patients. Diastolic and systolic functions of the LV, the size of the LA were under TEE and 2D ECHO controls. All the patients were discharged from the hospital. After the operation the needs for inotropic support were minimal. We did not see any local LV wall motion abnormalities. The end diastolic volume and long-axis dimension of the LV did not have any tendency to grow. New surgical technique of isolated SChS-MLR together with the symmetrical restoration of the LA shape and size can be equivalent to reconstructive mitral valve surgery from the hemodynamical point of view and allows us to standardize the surgical technique for those patients with significant left heart enlargement.