Milan Bebic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Milan Bebic has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
Leposava Ristic
Department for Power converters and drives, School of Electrical Engineering, University of Belgrade, Belgrade, Serbia
9 shared publicationsB. Jeftenic
University of Belgrade, EE Dept., Serbia
6 shared publicationsBorislav Jeftenic
Department of Technical Sciences, University of Novi Pazar, Novi Pazar, Serbia
6 shared publicationsSasa Statkic
Faculty of Technical Sciences Kosovska Mitrovica, Serbia statkic@etf.r Borislav Jeftenic EMP Engineering, Belgrade, Serbia
6 shared publicationsS. Statkic
Faculty of Technical Sciences, Kosovska Mitrovica, Serbia
4 shared publicationsB.I. Jeftenic
Faculty of Electrical Engineering, University of Belgrade, Republic of Serbia
3 shared publications
Latest Publications
- 20 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 3636-3648
Dual Direct Matrix Converter-Based Drives With Enhanced Input Power Factor Control and Common-Mode Voltage Elimination
The demand for high-efficiency, compact, and power-dense ac–ac conversion is driving renewed interest in matrix converters for industrial and renewable energy applications. This article introduces a novel input power factor (IPF) control strategy for a dual direct matrix converter (DMC)-based drive, enabling independent control of IPF while mitigating common-mode voltage (CMV) without additional hardware. Unlike conventional approaches that inherently constrain the reactive power control range, the proposed method extends IPF control to absolute maximum ratings, unlocking unprecedented flexibility in grid-interfacing applications. A fully decoupled approach to output voltage synthesis and IPF control is demonstrated by leveraging a generalized complex-domain model, ensuring optimal control across varying load conditions. Experimental validation is conducted on a dual DMC prototype, verifying the superior performance of the proposed method. The results highlight an expanded IPF control range and elimination of high-frequency CMV, positioning this methodology as a disruptive advancement in matrix converter technology.
- 20 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 3636-3648
Dual Direct Matrix Converter-Based Drives With Enhanced Input Power Factor Control and Common-Mode Voltage Elimination
The demand for high-efficiency, compact, and power-dense ac–ac conversion is driving renewed interest in matrix converters for industrial and renewable energy applications. This article introduces a novel input power factor (IPF) control strategy for a dual direct matrix converter (DMC)-based drive, enabling independent control of IPF while mitigating common-mode voltage (CMV) without additional hardware. Unlike conventional approaches that inherently constrain the reactive power control range, the proposed method extends IPF control to absolute maximum ratings, unlocking unprecedented flexibility in grid-interfacing applications. A fully decoupled approach to output voltage synthesis and IPF control is demonstrated by leveraging a generalized complex-domain model, ensuring optimal control across varying load conditions. Experimental validation is conducted on a dual DMC prototype, verifying the superior performance of the proposed method. The results highlight an expanded IPF control range and elimination of high-frequency CMV, positioning this methodology as a disruptive advancement in matrix converter technology.
- 1 January 2025
- Published by University Library in Kragujevac
- p. 123-130
MODERNIZACIJA ELEKTROMOTORNIH POGONA I UPRAVLJAČKOG SISTEMA POPREČNOG REZAČA VALMET 14,5 U FABRICI KARTONA UMKA
The modernization of electric drives and control systems in the paper and cardboard industry is a proven strategy for extending the service life of machines and improving their performance. This process typically involves replacing outdated electrical components—which are no longer manufactured—with modern, high-quality, widely available alternatives. As a result, maintenance costs are reduced, and system reliability is improved. This paper presents the successful modernization of the Valmet 14.5 crosscutter at the Umka Cardboard Mill, achieved through effective collaboration between domestic experts and the factory’s maintenance personnel. The task of installing new drives and control equipment—without increasing the line speed—while improving product quality and enhancing the plant’s operational reliability, was successfully completed at the beginning of 2025.
- 1 January 2025
- Published by University Library in Kragujevac
- p. 123-130
MODERNIZACIJA ELEKTROMOTORNIH POGONA I UPRAVLJAČKOG SISTEMA POPREČNOG REZAČA VALMET 14,5 U FABRICI KARTONA UMKA
The modernization of electric drives and control systems in the paper and cardboard industry is a proven strategy for extending the service life of machines and improving their performance. This process typically involves replacing outdated electrical components—which are no longer manufactured—with modern, high-quality, widely available alternatives. As a result, maintenance costs are reduced, and system reliability is improved. This paper presents the successful modernization of the Valmet 14.5 crosscutter at the Umka Cardboard Mill, achieved through effective collaboration between domestic experts and the factory’s maintenance personnel. The task of installing new drives and control equipment—without increasing the line speed—while improving product quality and enhancing the plant’s operational reliability, was successfully completed at the beginning of 2025.
- 1 January 2024
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. XXVI (4) , 43-49
Regulated Drive of Working Element of Bucket-Chain Excavator ERs710
Until the goal of complete transition to renewable energy sources is achieved, care must be taken to meet current energy needs. Of the total electricity produced in the Republic of Serbia in 2022, more than 68% will be energy obtained in thermal power plants. This data clearly indicates the necessity of preserving and extending the life of existing energy plants, which also include mining machines for unearthing the so-called overburden and coal (excavators) working in surface mines. The paper presents the modernization of the drive of the working element of the bucket-chain excavator.
- 1 January 2024
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. XXVI (4) , 43-49
Regulated Drive of Working Element of Bucket-Chain Excavator ERs710
Until the goal of complete transition to renewable energy sources is achieved, care must be taken to meet current energy needs. Of the total electricity produced in the Republic of Serbia in 2022, more than 68% will be energy obtained in thermal power plants. This data clearly indicates the necessity of preserving and extending the life of existing energy plants, which also include mining machines for unearthing the so-called overburden and coal (excavators) working in surface mines. The paper presents the modernization of the drive of the working element of the bucket-chain excavator.
- 30 March 2021
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in Turkish Journal of Electrical Engineering and Computer Sciences
- Vol. 29 (2) , 687-703
Improvements of torque ripple reduction in DTC IM drive with arbitrary number of voltage intensities and automatic algorithm modification
- 30 March 2021
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in Turkish Journal of Electrical Engineering and Computer Sciences
- Vol. 29 (2) , 687-703
Improvements of torque ripple reduction in DTC IM drive with arbitrary number of voltage intensities and automatic algorithm modification
- 1 December 2019
- Published by Elsevier in Engineering Failure Analysis
- Vol. 106
Concrete base influence on the increased vibrations level of the mill drive system elements - A case study
- 1 December 2019
- Published by Elsevier in Engineering Failure Analysis
- Vol. 106
Concrete base influence on the increased vibrations level of the mill drive system elements - A case study
- 1 December 2019
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 113, 393-402
Reliability assessment of the single motor drive of the belt conveyor on Drmno open-pit mine
- 1 December 2019
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 113, 393-402
Reliability assessment of the single motor drive of the belt conveyor on Drmno open-pit mine
- 9 August 2019
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 174 (9-10) , 777-789
The effect of gamma radiation on the stator insulation of rotating electrical machines
The paper examines the influence of γ radiation on the stability of the insulation characteristics of the stator winding of rotating electrical machines. The tested insulation characteristics are loss tangent angle, resistance, polarization factor, threshold voltage of partial discharge, breakdown voltage, coefficient of proportionality and lifetime exponent. The radiation dose was used as the γ radiation parameter. Different winding areas have been specifically tested in which a different impact is expected on technological winding production process. Tests were performed on a representative statistical sample under well-controlled laboratory conditions. The combined measurement uncertainty of the experimental procedure was about 5%.
- 9 August 2019
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 174 (9-10) , 777-789
The effect of gamma radiation on the stator insulation of rotating electrical machines
The paper examines the influence of γ radiation on the stability of the insulation characteristics of the stator winding of rotating electrical machines. The tested insulation characteristics are loss tangent angle, resistance, polarization factor, threshold voltage of partial discharge, breakdown voltage, coefficient of proportionality and lifetime exponent. The radiation dose was used as the γ radiation parameter. Different winding areas have been specifically tested in which a different impact is expected on technological winding production process. Tests were performed on a representative statistical sample under well-controlled laboratory conditions. The combined measurement uncertainty of the experimental procedure was about 5%.
- Open Access
- 1 January 2019
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 34 (3) , 264-271
Degradation of stator insulation of high-voltage asynchronous machines in gamma and neutron radiation field
This paper presents the results of an examination of function stability of high-voltage asynchronous motors exposed to ambient strain caused by combined neutron and gamma radiation. This problem appears in practice when a high-voltage asynchronous motor is used in nu- clear power plants where it can be exposed to this type of ambient strain. The failure of the engine's operation under such conditions may have unexpected consequences. As more than 50 % of failure (malfunction) of high-voltage asynchronous motors is caused by damage to stator insulation, the focus of the paper was on testing the effects of combined neutron and gamma radiation on stator insulation. The tests were carried out under well-controlled laboratory conditions on samples taken from both new and used factory coil windings. Two-layer samples were used to record partial discharge threshold voltage and breakdown voltage. By comparing the experimentally obtained results with the applicable mathematical-statistical procedure, an estimate was made of the aging acceleration of stator insulation and the time duration of reliable operation of high-voltage asynchronous motor was determined by life-time exponent.
- 1 January 2019
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 34 (3) , 264-271
Open AccessDegradation of stator insulation of high-voltage asynchronous machines in gamma and neutron radiation field
This paper presents the results of an examination of function stability of high-voltage asynchronous motors exposed to ambient strain caused by combined neutron and gamma radiation. This problem appears in practice when a high-voltage asynchronous motor is used in nu- clear power plants where it can be exposed to this type of ambient strain. The failure of the engine's operation under such conditions may have unexpected consequences. As more than 50 % of failure (malfunction) of high-voltage asynchronous motors is caused by damage to stator insulation, the focus of the paper was on testing the effects of combined neutron and gamma radiation on stator insulation. The tests were carried out under well-controlled laboratory conditions on samples taken from both new and used factory coil windings. Two-layer samples were used to record partial discharge threshold voltage and breakdown voltage. By comparing the experimentally obtained results with the applicable mathematical-statistical procedure, an estimate was made of the aging acceleration of stator insulation and the time duration of reliable operation of high-voltage asynchronous motor was determined by life-time exponent.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Application of the Microprocessor-Based MV Protective Equipment for Energy Management Purposes
The paper investigates the use of function of measurement of microprocessor-based protective relays connected to the protective current transformer for the energy management purposes. Accuracy of protective current transformers for the currents lower than the rated current is measured and analyzed. Based on obtained results, the necessary steps to ensure accuracy of measurements are presented.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Application of the Microprocessor-Based MV Protective Equipment for Energy Management Purposes
The paper investigates the use of function of measurement of microprocessor-based protective relays connected to the protective current transformer for the energy management purposes. Accuracy of protective current transformers for the currents lower than the rated current is measured and analyzed. Based on obtained results, the necessary steps to ensure accuracy of measurements are presented.