SCSteve Mario Cordina

Steve Mario Cordina

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Steve Mario Cordina has a total of 76 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comaneci-assisted embolization of wide-necked aneurysms: results from the SUCCESS postmarket US study

    by Jason M Davies, Muhammad Asif Taqi, Alexander L Coon, Li-Mei Lin, Bradley Bohnstedt, Justin Mascitelli, Elad I Levy, Adnan Siddiqui, Lee Birnbaum, Pavel Rodriguez, et al.

    Background: Wide-necked intracranial aneurysms present unique challenges for endovascular treatment. The Comaneci device is a novel temporary bridging device designed to assist coil embolization without parent vessel occlusion. Methods: The SUccess in Comaneci-assist Coils Embolization Surveillance Study (SUCCESS) was a multicenter, prospective, postmarket surveillance study conducted at 17 US centers. Ninety consecutive patients with wide-necked intracranial aneurysms were treated with Comaneci-assisted coiling. The primary effectiveness endpoint was successful aneurysm occlusion (Raymond-Roy class I/II) at procedure end. Primary safety endpoints included periprocedural events within 24 hours and clinical outcomes at discharge and 30 days. Results: Of 90 enrolled patients (mean age 63 years, 63% female), 32 (36%) presented with ruptured aneurysms. Most common locations were anterior communicating (33%), internal carotid (20%), and posterior communicating arteries (19%). Successful occlusion was achieved in 85.6% of cases at procedure end and 94.7% at 6 months. Good clinical outcome (modified Rankin Scale (mRS) 0–2) was maintained from baseline (73%) through 30 days (81%) and 6 months (83%). Thromboembolic events occurred in 5.5% of cases, all asymptomatic. Device-related complications were minimal, with coil entanglement in 0.3% of deployed coils and no instances of deployment/retrieval failure. All-cause mortality was 4.4%, confined to the ruptured aneurysm cohort. Conclusions: The SUCCESS study demonstrates high rates of successful aneurysm occlusion with Comaneci-assisted coiling, with occlusion rates persisting through 6 month follow-up. The safety profile was favorable, with low rates of thromboembolic events compared with other assist techniques. These results support the use of the Comaneci device for wide-necked aneurysm treatment in both ruptured and unruptured settings. Trial registration number: NCT04518670 .

  • Safety and efficacy of balloon-mounted stent in the treatment of symptomatic intracranial atherosclerotic disease: a multicenter experience

    by Mahmoud H Mohammaden, Raul G Nogueira, Wondwossen Tekle, Santiago Ortega-Gutierrez, Mudassir Farooqui, Cynthia B. Zevallos, Ricardo A Hanel, Gustavo M Cortez, Amin Aghaebrahim, Robert M Starke, et al.

    Background Randomized clinical trials have failed to prove that the safety and efficacy of endovascular treatment for symptomatic intracranial atherosclerotic disease (ICAD) is better than that of medical management. A recent study using a self-expandable stent showed acceptable lower rates of periprocedural complications. Objective To study the safety and efficacy of a balloon-mounted stent (BMS) in the treatment of symptomatic ICAD. Methods Prospectively maintained databases from 15 neuroendovascular centers between 2010 and 2020 were reviewed. Patients were included if they had severe symptomatic intracranial stenosis in the target artery, medical management had failed, and they underwent intracranial stenting with BMS after 24 hours of the qualifying event. The primary outcome was the occurrence of stroke and mortality within 72 hours after the procedure. Secondary outcomes were the occurrence of stroke, transient ischemic attacks (TIAs), and mortality on long-term follow-up. Results A total of 232 patients were eligible for the analysis (mean age 62.8 years, 34.1% female). The intracranial stenotic lesions were located in the anterior circulation in 135 (58.2%) cases. Recurrent stroke was the qualifying event in 165 (71.1%) while recurrent TIA was identified in 67 (28.9%) cases. The median (IQR) time from the qualifying event to stenting was 5 (2–20.75) days. Strokes were reported in 13 (5.6%) patients within 72 hours of the procedure; 9 (3.9%) ischemic and 4 (1.7%) hemorrhagic, and mortality in 2 (0.9%) cases. Among 189 patients with median follow-up time 6 (3–14.5) months, 12 (6.3%) had TIA and 7 (3.7%) had strokes. Three patients (1.6%) died from causes not related to stroke. Conclusion Our study has shown that BMS may be a safe and effective treatment for medically refractory symptomatic ICAD. Additional prospective randomized clinical trials are warranted.


  • Republished: Infantile intracranial aneurysm of the superior cerebellar artery

    by Molly Ann Del Santo, Steve Mario Cordina

    Intracranial aneurysms in the pediatric population are rare. We report a case of a 3-month-old infant who presented with inconsolable crying, vomiting, and sunset eye sign. CT revealed a subarachnoid hemorrhage, with CT angiogram revealing a superior cerebellar artery aneurysm. An external ventricular drain was placed for acute management of hydrocephalus, with definitive treatment by endovascular technique with a total of six microcoils to embolize the aneurysm. Serial transcranial Dopplers revealed no subsequent vasospasm. Although aneurysms in the pediatric population are rare, once the diagnosis is established, early treatment results in better outcomes.


  • Infantile intracranial aneurysm of the superior cerebellar artery

    by Molly Ann Del Santo, Steve Mario Cordina

    Intracranial aneurysms in the pediatric population are rare. We report a case of a 3-month-old infant who presented with inconsolable crying, vomiting, and sunset eye sign. CT revealed a subarachnoid hemorrhage, with CT angiogram revealing a superior cerebellar artery aneurysm. An external ventricular drain was placed for acute management of hydrocephalus, with definitive treatment by endovascular technique with a total of six microcoils to embolize the aneurysm. Serial transcranial Dopplers revealed no subsequent vasospasm. Although aneurysms in the pediatric population are rare, once the diagnosis is established, early treatment results in better outcomes.


  • Intracranial Vascular Calcification is Protective from Vasospasm after Aneurysmal Subarachnoid Hemorrhage

    by Haitham M. Hussein, Haralabos Zacharatos, Steve Cordina, Kamakshi Lakshminarayan, Mustapha A. Ezzeddine


    • 1 June 2013
      • Vol. 6  (1) , 7-9

    Sequential sidelong balloon remodeling technique in coil embolization of a wide-necked basilar tip aneurysm.

    by Rakesh Khatri, Steve M Cordina, Ameer E Hassan, Mikayel Grigoryan, Gustavo J Rodriguez

    The use of balloon remodeling technique for coil embolization has developed into a safe alternative to stent assisted coil embolization for wide-necked aneurysms. Dual antiplatelet therapy when a stent is placed for assistance in the treatment of ruptured aneurysms is of concern. There are cases in which a single balloon seems insufficient to protect from coil herniation, like when two vessels are in the proximity of the side of the aneurysm neck. Techniques using two balloons for remodeling have been described; however, dual vascular access may be required. A case is presented in which a ruptured basilar tip wide-necked aneurysm was treated with a single balloon, using a sequential sidelong balloon remodeling technique. Complete embolization of the aneurysm was achieved maintaining patency of bilateral posterior cerebral arteries.


  • Frequency and Factors Associated With Unsuccessful Lead (First) Coil Placement in Patients Undergoing Coil Embolization of Intracranial Aneurysms

    by Rakesh Khatri, Saqib A. Chaudhry, Gustavo J. Rodriguez, M. Fareed K. Suri, Steve M. Cordina, Adnan I. Qureshi

    There is limited knowledge about associated rates, aneurysm characteristics, technical factors, and immediate impact of unsuccessful placement of the lead (first) coil during endovascular embolization of intracranial aneurysms. To determine the rates, associated risk factors, and consequences of lead coil placement failure in consecutive embolization procedures. We reviewed clinical and procedural aspects of all endovascular coil embolizations performed at our 2 academic centers over a period of 3.5 years (2006-2010). Morphologic characteristics of the aneurysm and technical aspects of the treatment were recorded. We also performed a flow model analysis to assess the relationship between aneurysm dimensions, length of coil, packing density with first coil, and occurrence of lead coil placement failure. There were 24 (14%) lead coil placement failure procedures in 172 aneurysm embolization procedures; in 23 of 24 (96%) patients with lead coil placement failure, the failure occurred in aneurysms less than 10 mm in size. The main technical factors associated with lead coil placement failure were related to the coil (length, diameter, and type) followed by microcatheter support failure. Among these patients, 21 (87.5%) required change in the coil length, 17 (70.8%) change in coil diameter, and 10 (41.7%) change in coil type (brand and/or configuration) for successful placement of the lead coil. A total of 4 (16.7%) patients required change in microcatheter, and 6 (24.9%) patients had balloon/stent assistance for successful lead coil placement. Two of 24 (8.3%) patients had rupture of their aneurysms during the attempt to reposition the lead coil. In our flow model, these clinical observations were reproduced with higher risk of lead coil failure in smaller aneurysms. Lead coil placement failure is not infrequent during embolization of intracranial aneurysms and may increase the risk of complications. Appropriate coil selection, particularly coil length in small aneurysms, may reduce the rate of lead coil placement failure and associated complications.


  • Aspirin Treatment Failure and the Risk of Recurrent Stroke and Death Among Patients with Ischemic Stroke

    by Alexandros L. Georgiadis, Steve M. Cordina, Gabriela Vazquez, Nauman Tariq, M. Fareed K. Suri, Kamakshi Lakshminarayan, Harold P. Adams, Adnan I. Qureshi


  • Vessel occlusion using a single long oversized coil in vertebral artery dissection: a technical note

    by Mikayel Grigoryan, Steve M Cordina, Rakesh Khatri, Ameer E Hassan, Gustavo J Rodriguez

    Vertebral artery dissection may lead to stroke. Medical therapy is usually the first line of treatment. The endovascular approach of medically refractory vertebral artery dissection may include numerous techniques, including coil occlusion of the parent vessel. Two cases are presented of medically refractory symptomatic vertebral artery dissections in which vessel coil occlusion was successfully achieved with a single long oversized coil. There were no periprocedural complications and both patients had excellent clinical and angiographic outcome and remained asymptomatic on follow-up. The use of a single long oversized coil in vessel sacrifice has not been described previously. It represents a safe, rapid and cost effective alternative to the current existing techniques for vessel sacrifice.