Vincent Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Vincent Cheng has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Ching-Yee Oliver Wong
Department of Nuclear Medicine, William Beaumont Hospital, 3601 W. Thirteen Mile Road, Royal Oak, MI 48073-6769, USA
2 shared publications A.A. Martinez
William Beaumont Hospital, Royal Oak, MI
1 shared publication- Alvaro Martinez
21st Century Oncology (a division of Michigan Healthcare Professionals), Farmington Hills, MI
1 shared publication C. Nagle
William Beaumont Hospital, Royal Oak, MI
1 shared publicationC.O. Wong
William Beaumont Hospital, Royal Oak, MI
1 shared publicationConrad Nagle
Positron Diagnostic Center and Medical Cyclotron, Department of Nuclear Medicine, William Beaumont Hospital, Royal Oak, MI
1 shared publication
Latest Publications
- 1 May 2009
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 81 (11) , 4566-4575
Magnetic Bead Processor for Rapid Evaluation and Optimization of Parameters for Phosphopeptide Enrichment
Qualitative and quantitative analysis of phosphorylation continues to be both an important and a challenging experimental paradigm in proteomics-based research. Unfortunately researchers face difficulties inherent to the optimization of complex, multivariable methods and their application to the analysis of rare and often experimentally intractable phosphorylated peptides. Here we describe a platform based on manipulation of magnetic beads in a 96-well format that facilitates rapid evaluation of experimental parameters required for enrichment of phosphopeptides. Optimized methods provided for automated enrichment and subsequent LC-MS/MS detection of over 1000 unique phosphopeptides (∼1% FDR) from 50 μg of cell lysates. In addition we demonstrate use of this platform for identification of phosphopeptides derived from proteins separated by SDS-PAGE and visualized near the detection limit of silver staining.
- 1 May 2009
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 81 (11) , 4566-4575
Magnetic Bead Processor for Rapid Evaluation and Optimization of Parameters for Phosphopeptide Enrichment
Qualitative and quantitative analysis of phosphorylation continues to be both an important and a challenging experimental paradigm in proteomics-based research. Unfortunately researchers face difficulties inherent to the optimization of complex, multivariable methods and their application to the analysis of rare and often experimentally intractable phosphorylated peptides. Here we describe a platform based on manipulation of magnetic beads in a 96-well format that facilitates rapid evaluation of experimental parameters required for enrichment of phosphopeptides. Optimized methods provided for automated enrichment and subsequent LC-MS/MS detection of over 1000 unique phosphopeptides (∼1% FDR) from 50 μg of cell lysates. In addition we demonstrate use of this platform for identification of phosphopeptides derived from proteins separated by SDS-PAGE and visualized near the detection limit of silver staining.
- Open Access
- 1 December 2007
- Published by Springer Nature in Radiation Oncology
- Vol. 2 (1) , 18
Correlating metabolic and anatomic responses of primary lung cancers to radiotherapy by combined F-18 FDG PET-CT imaging
Background: To correlate the metabolic changes with size changes for tumor response by concomitant PET-CT evaluation of lung cancers after radiotherapy. Methods: 36 patients were studied pre- and post-radiotherapy with18FDG PET-CT scans at a median interval of 71 days. All of the patients were followed clinically and radiographically after a mean period of 342 days for assessment of local control or failure rates. Change in size (sum of maximum orthogonal diameters) was correlated with that of maximum standard uptake value (SUV) of the primary lung cancer before and after conventional radiotherapy. Results: There was a significant reduction in both SUV and size of the primary cancer after radiotherapy (p < 0.00005). Among the 20 surviving patients, the sensitivity, specificity, and accuracy using PET (SUV) were 94%, 50%, 90% respectively and the corresponding values using and CT (size criteria) were 67%, 50%, and 65% respectively. The metabolic change (SUV) was highly correlated with the change in size by a quadratic function. In addition, the mean percentage metabolic change was significantly larger than that of size change (62.3 ± 32.7% vs 47.1 ± 26.1% respectively, p = 0.03) Conclusion: Correlating and incorporating metabolic change by PET into size change by concomitant CT is more sensitive in assessing therapeutic response than CT alone.
- 1 December 2007
- Published by Springer Nature in Radiation Oncology
- Vol. 2 (1) , 18
Open AccessCorrelating metabolic and anatomic responses of primary lung cancers to radiotherapy by combined F-18 FDG PET-CT imaging
Background: To correlate the metabolic changes with size changes for tumor response by concomitant PET-CT evaluation of lung cancers after radiotherapy. Methods: 36 patients were studied pre- and post-radiotherapy with18FDG PET-CT scans at a median interval of 71 days. All of the patients were followed clinically and radiographically after a mean period of 342 days for assessment of local control or failure rates. Change in size (sum of maximum orthogonal diameters) was correlated with that of maximum standard uptake value (SUV) of the primary lung cancer before and after conventional radiotherapy. Results: There was a significant reduction in both SUV and size of the primary cancer after radiotherapy (p < 0.00005). Among the 20 surviving patients, the sensitivity, specificity, and accuracy using PET (SUV) were 94%, 50%, 90% respectively and the corresponding values using and CT (size criteria) were 67%, 50%, and 65% respectively. The metabolic change (SUV) was highly correlated with the change in size by a quadratic function. In addition, the mean percentage metabolic change was significantly larger than that of size change (62.3 ± 32.7% vs 47.1 ± 26.1% respectively, p = 0.03) Conclusion: Correlating and incorporating metabolic change by PET into size change by concomitant CT is more sensitive in assessing therapeutic response than CT alone.
- 1 November 2006
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 66 (3) , S479-479
2482: Incorporating Glucose Sensitivity Into a Comprehensive CT-PET Evaluation of Lung Cancers After Radiation
- 1 November 2006
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 66 (3) , S479-479
2482: Incorporating Glucose Sensitivity Into a Comprehensive CT-PET Evaluation of Lung Cancers After Radiation
- 1 August 2006
- Published by SAGE Publications in Cancer Biotherapy and Radiopharmaceuticals
- Vol. 21 (4) , 305-313
Regional Yttrium-90 Microsphere Treatment of Surgically Unresectable and Chemotherapy-Refractory Metastatic Liver Carcinoma
Purpose: The aim of this prospective study was to assess the safety and tumor response of intra-arterial Y- 90 microspheres for the treatment of surgically unresectable and chemotherapy-refractory liver metastases. Materials and Methods: Forty-six (46) patients with metastatic cancer to the liver from various solid tumors, with tumor progression despite polychemotherapy, were included. All patients had baseline computed tomography (CT), 18-Fluoro-2-deoxy-D-glucose–positron emission tomography (F-18 FDG-PET), hepatic angiography, and intra-arterial Tc-99m macroaggregated albumin (MAA) scan for the assessment of extrahepatic aberrant perfusion and lung shunting fraction. Twenty-seven (27) and 19 patients were treated with Y-90 glass- or resin-based microspheres (but not both), respectively, on a lobar basis and were monitored over 3 months after last treatment using dedicated attenuation corrected PET. For each patient, regions of interest (ROIs) were drawn along the liver edge to measure total liver standard uptake value (SUV) on axial images covering the entire liver for comparing pre- and post-treatment total liver SUV change. Results: There was a significant decrement in total liver SUV after treatment by either glass- or resin-based microspheres (p = 0.0013 and 0.028, respectively). There was no significant difference in the amplitudes of the mean percentage reduction of tumor metabolism between these two agents (20% ± 25% vs. 10% ± 30% for glass- vs. resin-based microspheres; p = 0.38). None of the patients in the glass-based group developed complications, whereas 3 patients had complications related to hyperbilirubinemia (1 transient and 2 permanent) in the resinbased group. Conclusions: Results suggest that there is significant mean reduction of hepatic metastatic tumor load (metabolism), as evaluated objectively by PET after Y-90 microsphere, for the treatment of unresectable metastatic disease to the liver. The Y-90 therapy provides encouraging and safe results by arresting the progression of metastatic cancer to the liver with decreasing tumor metabolism.
- 1 August 2006
- Published by SAGE Publications in Cancer Biotherapy and Radiopharmaceuticals
- Vol. 21 (4) , 305-313
Regional Yttrium-90 Microsphere Treatment of Surgically Unresectable and Chemotherapy-Refractory Metastatic Liver Carcinoma
Purpose: The aim of this prospective study was to assess the safety and tumor response of intra-arterial Y- 90 microspheres for the treatment of surgically unresectable and chemotherapy-refractory liver metastases. Materials and Methods: Forty-six (46) patients with metastatic cancer to the liver from various solid tumors, with tumor progression despite polychemotherapy, were included. All patients had baseline computed tomography (CT), 18-Fluoro-2-deoxy-D-glucose–positron emission tomography (F-18 FDG-PET), hepatic angiography, and intra-arterial Tc-99m macroaggregated albumin (MAA) scan for the assessment of extrahepatic aberrant perfusion and lung shunting fraction. Twenty-seven (27) and 19 patients were treated with Y-90 glass- or resin-based microspheres (but not both), respectively, on a lobar basis and were monitored over 3 months after last treatment using dedicated attenuation corrected PET. For each patient, regions of interest (ROIs) were drawn along the liver edge to measure total liver standard uptake value (SUV) on axial images covering the entire liver for comparing pre- and post-treatment total liver SUV change. Results: There was a significant decrement in total liver SUV after treatment by either glass- or resin-based microspheres (p = 0.0013 and 0.028, respectively). There was no significant difference in the amplitudes of the mean percentage reduction of tumor metabolism between these two agents (20% ± 25% vs. 10% ± 30% for glass- vs. resin-based microspheres; p = 0.38). None of the patients in the glass-based group developed complications, whereas 3 patients had complications related to hyperbilirubinemia (1 transient and 2 permanent) in the resinbased group. Conclusions: Results suggest that there is significant mean reduction of hepatic metastatic tumor load (metabolism), as evaluated objectively by PET after Y-90 microsphere, for the treatment of unresectable metastatic disease to the liver. The Y-90 therapy provides encouraging and safe results by arresting the progression of metastatic cancer to the liver with decreasing tumor metabolism.