Mark R. Sims
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Mark R. Sims has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- David C. Cullen
Space Group, School of Aerospace, Transport & Manufacturing, Cranfield University, Cranfield, UK
15 shared publications - Mark A. Sephton
Department of Earth Science and Engineering, Imperial College London, London, UK
11 shared publications R. Willingale
10 shared publicationsAlan A. Wells
Univ. of Leicester (United Kingdom)
9 shared publicationsD. Pullan
Leicester Institute for Space and Earth Observation, Department of Physics and Astronomy, University of Leicester, Leicester LE1 7RH, UK
9 shared publicationsRichard W. Court
Department of Earth Science and Engineering, Imperial College London , London, UK
7 shared publications
Latest Publications
- 1 December 2018
- Published by Intellect in Virtual Creativity
- Vol. 8 (2) , 159-178
3D technology as an effective tool for reflection simulation: The Beagle 2 lander on Mars
Beagle 2, developed for the European Space Agency’s Mars Express Mission by the Beagle 2 Consortium, was due to land on Mars on 25 December 2003. After being successfully ejected from the ESA’s orbiter Mars Express, followed by an attempted landing, the spacecraft failed to communicate with Earth, and the mission was presumed lost. However, in January 2015, it was announced that satellite images from NASA’s Mars Reconnaissance Orbiter (MRO) indicated the possibility of a successful landing by Beagle 2. In the light of these findings and the considerable uncertainty still surrounding the outcome of the mission, a team of researchers from De Montfort University and the University of Leicester have joined in a collaborative project aimed at identifying whether the object captured by NASA’s HiRISE camera is Beagle 2, and detecting its possible landing configuration. The practical scientific experiment employed the innovative concept of ‘reflection analysis’, propounded by Dr Mark Sims – former Beagle 2 Mission Manager and professor of astrobiology and Space Instrumentation at the Space Research Centre, University of Leicester. The technique stemmed from the idea of simulating possible configurations of the Beagle 2 lander, testing how they reflect light and comparing the 3D renders to unprocessed images, available from the MRO’s HiRISE camera at a number of different sun angles. De Montfort University’s team used commercial 3D modelling technology to create a 3D model of the spacecraft and replicate virtually the sun angles at the times the satellite images were taken. This allowed a comparison of the simulated 3D renders to the satellite images to estimate the configuration of Beagle 2 on Mars. The results revealed that Beagle 2 probably deployed at least three, and possibly all four of its solar panels after landing on the planet’s surface.
- 1 December 2018
- Published by Intellect in Virtual Creativity
- Vol. 8 (2) , 159-178
3D technology as an effective tool for reflection simulation: The Beagle 2 lander on Mars
Beagle 2, developed for the European Space Agency’s Mars Express Mission by the Beagle 2 Consortium, was due to land on Mars on 25 December 2003. After being successfully ejected from the ESA’s orbiter Mars Express, followed by an attempted landing, the spacecraft failed to communicate with Earth, and the mission was presumed lost. However, in January 2015, it was announced that satellite images from NASA’s Mars Reconnaissance Orbiter (MRO) indicated the possibility of a successful landing by Beagle 2. In the light of these findings and the considerable uncertainty still surrounding the outcome of the mission, a team of researchers from De Montfort University and the University of Leicester have joined in a collaborative project aimed at identifying whether the object captured by NASA’s HiRISE camera is Beagle 2, and detecting its possible landing configuration. The practical scientific experiment employed the innovative concept of ‘reflection analysis’, propounded by Dr Mark Sims – former Beagle 2 Mission Manager and professor of astrobiology and Space Instrumentation at the Space Research Centre, University of Leicester. The technique stemmed from the idea of simulating possible configurations of the Beagle 2 lander, testing how they reflect light and comparing the 3D renders to unprocessed images, available from the MRO’s HiRISE camera at a number of different sun angles. De Montfort University’s team used commercial 3D modelling technology to create a 3D model of the spacecraft and replicate virtually the sun angles at the times the satellite images were taken. This allowed a comparison of the simulated 3D renders to the satellite images to estimate the configuration of Beagle 2 on Mars. The results revealed that Beagle 2 probably deployed at least three, and possibly all four of its solar panels after landing on the planet’s surface.
- Open Access
- 31 July 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (7) , e0201562
A pilot study of the Leicester ED medical infrared imaging protocol in fever and sepsis
Medical Infrared Imaging (MII) is an investigative method that can be potentially used in emergency care to non-invasively detect thermal signatures associated with change in blood flow. We have developed a protocol for the use of MII in the Emergency Department (ED) and shown that it is feasible. To derive initial data for sample size calculations, we performed an exploratory study in patients with fever and sepsis. The Leicester MII protocol was used to image the temperature patterns along the arm among three patient groups (control, fever and sepsis) of a total 56 patients. Anatomical markers were used to divide this gradient into upper arm, forearm, hand and finger regions. Variations in measurements within and between these regions were described. The thermal gradient down the arm was successfully extracted in all patients. The distribution of values in each region of the arm was described in control, fever and sepsis patients. There was a significant gradient between upper arm and finger in controls (2.75, p < 0.0001), but no gradient in fever (p = 0.944) or sepsis (p = 0.710). This was reflected in the finger/arm difference, which was of -2.74°C (±3.50) in controls, -0.39C (±2.48) in fever, and -1.80°C (±3.09) in sepsis. This study found different thermal gradients along the arm in control and febrile groups, and defined the degree of individual variation. It is likely that the difference between upper arm temperature and finger temperature (representing the temperature gradient down the arm) may be more useful than absolute measurements in future studies.
- 31 July 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (7) , e0201562
Open AccessA pilot study of the Leicester ED medical infrared imaging protocol in fever and sepsis
Medical Infrared Imaging (MII) is an investigative method that can be potentially used in emergency care to non-invasively detect thermal signatures associated with change in blood flow. We have developed a protocol for the use of MII in the Emergency Department (ED) and shown that it is feasible. To derive initial data for sample size calculations, we performed an exploratory study in patients with fever and sepsis. The Leicester MII protocol was used to image the temperature patterns along the arm among three patient groups (control, fever and sepsis) of a total 56 patients. Anatomical markers were used to divide this gradient into upper arm, forearm, hand and finger regions. Variations in measurements within and between these regions were described. The thermal gradient down the arm was successfully extracted in all patients. The distribution of values in each region of the arm was described in control, fever and sepsis patients. There was a significant gradient between upper arm and finger in controls (2.75, p < 0.0001), but no gradient in fever (p = 0.944) or sepsis (p = 0.710). This was reflected in the finger/arm difference, which was of -2.74°C (±3.50) in controls, -0.39C (±2.48) in fever, and -1.80°C (±3.09) in sepsis. This study found different thermal gradients along the arm in control and febrile groups, and defined the degree of individual variation. It is likely that the difference between upper arm temperature and finger temperature (representing the temperature gradient down the arm) may be more useful than absolute measurements in future studies.
- Open Access
- 1 July 2018
- Published by Elsevier in Advances In Space Research
- Vol. 62 (1) , 191-244
The THESEUS space mission concept: science case, design and expected performances
- 1 July 2018
- Published by Elsevier in Advances In Space Research
- Vol. 62 (1) , 191-244
Open AccessThe THESEUS space mission concept: science case, design and expected performances
- Open Access
- 11 October 2017
- Published by The Royal Society in Royal Society Open Science
- Vol. 4 (10) , 170785
Identification of the Beagle 2 lander on Mars
The 2003 Beagle 2 Mars lander has been identified in Isidis Planitia at 90.43° E, 11.53° N, close to the predicted target of 90.50° E, 11.53° N. Beagle 2 was an exobiology lander designed to look for isotopic and compositional signs of life on Mars, as part of the European Space Agency Mars Express (MEX) mission. The 2004 recalculation of the original landing ellipse from a 3-sigma major axis from 174 km to 57 km, and the acquisition of Mars Reconnaissance Orbiter High Resolution Imaging Science Experiment (HiRISE) imagery at 30 cm per pixel across the target region, led to the initial identification of the lander in 2014. Following this, more HiRISE images, giving a total of 15, including red and blue-green colours, were obtained over the area of interest and searched, which allowed sub-pixel imaging using super high-resolution techniques. The size (approx. 1.5 m), distinctive multilobed shape, high reflectivity relative to the local terrain, specular reflections, and location close to the centre of the planned landing ellipse led to the identification of the Beagle 2 lander. The shape of the imaged lander, although to some extent masked by the specular reflections in the various images, is consistent with deployment of the lander lid and then some or all solar panels. Failure to fully deploy the panels—which may have been caused by damage during landing—would have prohibited communication between the lander and MEX and commencement of science operations. This implies that the main part of the entry, descent and landing sequence, the ejection from MEX, atmospheric entry and parachute deployment, and landing worked as planned with perhaps only the final full panel deployment failing.
- 11 October 2017
- Published by The Royal Society in Royal Society Open Science
- Vol. 4 (10) , 170785
Open AccessIdentification of the Beagle 2 lander on Mars
The 2003 Beagle 2 Mars lander has been identified in Isidis Planitia at 90.43° E, 11.53° N, close to the predicted target of 90.50° E, 11.53° N. Beagle 2 was an exobiology lander designed to look for isotopic and compositional signs of life on Mars, as part of the European Space Agency Mars Express (MEX) mission. The 2004 recalculation of the original landing ellipse from a 3-sigma major axis from 174 km to 57 km, and the acquisition of Mars Reconnaissance Orbiter High Resolution Imaging Science Experiment (HiRISE) imagery at 30 cm per pixel across the target region, led to the initial identification of the lander in 2014. Following this, more HiRISE images, giving a total of 15, including red and blue-green colours, were obtained over the area of interest and searched, which allowed sub-pixel imaging using super high-resolution techniques. The size (approx. 1.5 m), distinctive multilobed shape, high reflectivity relative to the local terrain, specular reflections, and location close to the centre of the planned landing ellipse led to the identification of the Beagle 2 lander. The shape of the imaged lander, although to some extent masked by the specular reflections in the various images, is consistent with deployment of the lander lid and then some or all solar panels. Failure to fully deploy the panels—which may have been caused by damage during landing—would have prohibited communication between the lander and MEX and commencement of science operations. This implies that the main part of the entry, descent and landing sequence, the ejection from MEX, atmospheric entry and parachute deployment, and landing worked as planned with perhaps only the final full panel deployment failing.
- 20 March 2017
- Published by Wiley in Emergency Medicine Australasia
- Vol. 29 (4) , 391-393
Thoracic electrical bioimpedance versus suprasternal Doppler in emergency care
Objective: There are a number of cardiac output (CO) monitors that could potentially be used in the ED. Two of the most promising methods, thoracic electrical bioimpedance and suprasternal Doppler, have not been directly compared. The aim of this study was to investigate the feasibility of CO monitoring using suprasternal Doppler and bioimpedance in emergency care and compare haemodynamic data obtained from both monitors.Methods: Haemodynamic measurements were made on the same group of patients using bioimpedance (Niccomo, Medis, Germany) and suprasternal Doppler (USCOM, Sydney, Australia).Results: Usable CO data were obtained in 97% of patients by suprasternal Doppler and 87% by bioimpedance. The median CO obtained by Doppler was 3.4 L/min lower than bioimpedance. The stroke volume median was lower by 51 mL in Doppler.Conclusions: These two methods of non‐invasive cardiac monitoring are not interchangeable. The results suggest that the choice of non‐invasive cardiac monitor is important, but the grounds on which to make this choice are not currently clear.
- 20 March 2017
- Published by Wiley in Emergency Medicine Australasia
- Vol. 29 (4) , 391-393
Thoracic electrical bioimpedance versus suprasternal Doppler in emergency care
Objective: There are a number of cardiac output (CO) monitors that could potentially be used in the ED. Two of the most promising methods, thoracic electrical bioimpedance and suprasternal Doppler, have not been directly compared. The aim of this study was to investigate the feasibility of CO monitoring using suprasternal Doppler and bioimpedance in emergency care and compare haemodynamic data obtained from both monitors.Methods: Haemodynamic measurements were made on the same group of patients using bioimpedance (Niccomo, Medis, Germany) and suprasternal Doppler (USCOM, Sydney, Australia).Results: Usable CO data were obtained in 97% of patients by suprasternal Doppler and 87% by bioimpedance. The median CO obtained by Doppler was 3.4 L/min lower than bioimpedance. The stroke volume median was lower by 51 mL in Doppler.Conclusions: These two methods of non‐invasive cardiac monitoring are not interchangeable. The results suggest that the choice of non‐invasive cardiac monitor is important, but the grounds on which to make this choice are not currently clear.
- Open Access
- 10 November 2016
- Published by SAGE Publications in Journal of the Intensive Care Society
- Vol. 18 (3) , 221-227
The microcirculation and its measurement in sepsis
The microcirculation describes the smallest elements of the cardiovascular conducting system and is pivotal in the maintenance of homeostasis. Microcirculatory dysfunction is present early in the pathophysiology of sepsis, with the extent of microcirculatory derangement relating to disease severity and prognosis in ICU patients. However, at present microcirculatory function is not routinely monitored at the bedside. This article describes the pathophysiology of microcirculatory derangements in sepsis, methods of its measurement and evidence to support their clinical use.
- 10 November 2016
- Published by SAGE Publications in Journal of the Intensive Care Society
- Vol. 18 (3) , 221-227
Open AccessThe microcirculation and its measurement in sepsis
The microcirculation describes the smallest elements of the cardiovascular conducting system and is pivotal in the maintenance of homeostasis. Microcirculatory dysfunction is present early in the pathophysiology of sepsis, with the extent of microcirculatory derangement relating to disease severity and prognosis in ICU patients. However, at present microcirculatory function is not routinely monitored at the bedside. This article describes the pathophysiology of microcirculatory derangements in sepsis, methods of its measurement and evidence to support their clinical use.
- 25 July 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9905, 99051R
The LOFT mission concept: a status update
The Large Observatory For x-ray Timing (LOFT) is a mission concept which was proposed to ESA as M3 and M4 candidate in the framework of the Cosmic Vision 2015-2025 program. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument and the uniquely large field of view of its wide field monitor, LOFT will be able to study the behaviour of matter in extreme conditions such as the strong gravitational field in the innermost regions close to black holes and neutron stars and the supra-nuclear densities in the interiors of neutron stars. The science payload is based on a Large Area Detector (LAD, >8m2 effective area, 2-30 keV, 240 eV spectral resolution, 1 degree collimated field of view) and a Wide Field Monitor (WFM, 2-50 keV, 4 steradian field of view, 1 arcmin source location accuracy, 300 eV spectral resolution). The WFM is equipped with an on-board system for bright events (e.g., GRB) localization. The trigger time and position of these events are broadcast to the ground within 30 s from discovery. In this paper we present the current technical and programmatic status of the mission.
- 25 July 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9905, 99051R
The LOFT mission concept: a status update
The Large Observatory For x-ray Timing (LOFT) is a mission concept which was proposed to ESA as M3 and M4 candidate in the framework of the Cosmic Vision 2015-2025 program. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument and the uniquely large field of view of its wide field monitor, LOFT will be able to study the behaviour of matter in extreme conditions such as the strong gravitational field in the innermost regions close to black holes and neutron stars and the supra-nuclear densities in the interiors of neutron stars. The science payload is based on a Large Area Detector (LAD, >8m2 effective area, 2-30 keV, 240 eV spectral resolution, 1 degree collimated field of view) and a Wide Field Monitor (WFM, 2-50 keV, 4 steradian field of view, 1 arcmin source location accuracy, 300 eV spectral resolution). The WFM is equipped with an on-board system for bright events (e.g., GRB) localization. The trigger time and position of these events are broadcast to the ground within 30 s from discovery. In this paper we present the current technical and programmatic status of the mission.
- Open Access
- 22 April 2015
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 114 (6) , 874-877
Known knowns, known unknowns, and unknown unknowns: can systems medicine provide a new approach to sepsis?
Further relevant concepts include data mining and mechanistic modelling. Data mining is a technique in which all possible data are collected and analysed to ide
- 22 April 2015
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 114 (6) , 874-877
Open AccessKnown knowns, known unknowns, and unknown unknowns: can systems medicine provide a new approach to sepsis?
Further relevant concepts include data mining and mechanistic modelling. Data mining is a technique in which all possible data are collected and analysed to ide
- 1 September 2014
- Published by SAGE Publications in Astrobiology
- Vol. 14 (9) , 733-752
Searching for Life on Mars: Degradation of Surfactant Solutions Used in Organic Extraction Experiments
Life-detection instruments on future Mars missions may use surfactant solutions to extract organic matter from samples of martian rocks. The thermal and radiation environments of space and Mars are capable of degrading these solutions, thereby reducing their ability to dissolve organic species. Successful extraction and detection of biosignatures on Mars requires an understanding of how degradation in extraterrestrial environments can affect surfactant performance. We exposed solutions of the surfactants polysorbate 80 (PS80), Zonyl FS-300, and poly[dimethylsiloxane-co-[3-(2-(2-hydroxyethoxy)ethoxy)propyl]methylsiloxane] (PDMSHEPMS) to elevated radiation and heat levels, combined with prolonged storage. Degradation was investigated by measuring changes in pH and electrical conductivity and by using the degraded solutions to extract a suite of organic compounds spiked onto grains of the martian soil simulant JSC Mars-1. Results indicate that the proton fluences expected during a mission to Mars do not cause significant degradation of surfactant compounds. Solutions of PS80 or PDMSHEPMS stored at -20 °C are able to extract the spiked standards with acceptable recovery efficiencies. Extraction efficiencies for spiked standards decrease progressively with increasing temperature, and prolonged storage at 60°C renders the surfactant solutions ineffective. Neither the presence of ascorbic acid nor the choice of solvent unequivocally alters the efficiency of extraction of the spiked standards. Since degradation of polysorbates has the potential to produce organic compounds that could be mistaken for indigenous martian organic matter, the polysiloxane PDMSHEPMS may be a superior choice of surfactant for the exploration of Mars.
- 1 September 2014
- Published by SAGE Publications in Astrobiology
- Vol. 14 (9) , 733-752
Searching for Life on Mars: Degradation of Surfactant Solutions Used in Organic Extraction Experiments
Life-detection instruments on future Mars missions may use surfactant solutions to extract organic matter from samples of martian rocks. The thermal and radiation environments of space and Mars are capable of degrading these solutions, thereby reducing their ability to dissolve organic species. Successful extraction and detection of biosignatures on Mars requires an understanding of how degradation in extraterrestrial environments can affect surfactant performance. We exposed solutions of the surfactants polysorbate 80 (PS80), Zonyl FS-300, and poly[dimethylsiloxane-co-[3-(2-(2-hydroxyethoxy)ethoxy)propyl]methylsiloxane] (PDMSHEPMS) to elevated radiation and heat levels, combined with prolonged storage. Degradation was investigated by measuring changes in pH and electrical conductivity and by using the degraded solutions to extract a suite of organic compounds spiked onto grains of the martian soil simulant JSC Mars-1. Results indicate that the proton fluences expected during a mission to Mars do not cause significant degradation of surfactant compounds. Solutions of PS80 or PDMSHEPMS stored at -20 °C are able to extract the spiked standards with acceptable recovery efficiencies. Extraction efficiencies for spiked standards decrease progressively with increasing temperature, and prolonged storage at 60°C renders the surfactant solutions ineffective. Neither the presence of ascorbic acid nor the choice of solvent unequivocally alters the efficiency of extraction of the spiked standards. Since degradation of polysorbates has the potential to produce organic compounds that could be mistaken for indigenous martian organic matter, the polysiloxane PDMSHEPMS may be a superior choice of surfactant for the exploration of Mars.
- 1 September 2014
- Published by Elsevier in Planetary and Space Science
- Vol. 99, 19-27
Extracting organic matter on Mars: A comparison of methods involving subcritical water, surfactant solutions and organic solvents
- 1 September 2014
- Published by Elsevier in Planetary and Space Science
- Vol. 99, 19-27
Extracting organic matter on Mars: A comparison of methods involving subcritical water, surfactant solutions and organic solvents