DZDong Zhang

Dong Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dong Zhang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Analysis of Thermal Effects for Polymer-Housed Metal-Oxide Surge Arrester Under Multiple Strokes

    by Lin Huang, Lijun Zhou, Wei Chen, Renwei Wei, Dong Zhang, Dongyang Wang, Haiquan Zhao, Yutang Ma

    Multiple strokes are the main factors affecting the safe and stable operation of power equipment. As the core lightning protection equipment, arresters are also frequently thermally collapsed due to multiple strokes. This paper investigates thermal effects of polymer-housed metal-oxide surge arrester (PMOSA) under multiple strokes. The comparative experiments of PMOSA lightning impulse are carried out through multiple strokes of experiment platform, including continuous lightning stroke and multiple strokes. Furthermore, the temperature distribution of the housing surface is obtained by infrared imager for thermal effect analysis. Subsequently, some typical DC parameters are tested to explore the association of impulse aging and thermal effects of the arrester under multiple strokes. Finally, a thermal-electric coupling model (TECM) is constructed to investigate the influence of some factors on the temperature of PMOSA from the perspective of materials and structure. The research in this paper can provide a theory reference and brief data support for improving the heat dissipation performance of arresters under multiple strokes based on structural optimization design and material modification.


  • A Case Study on the Risk Assessment for the Grass Carp Fish During a Lightning Strike to Nearby Distribution Tower and Some Suggestion on Protective Measures

    by Lijun Zhou, Dong Zhang, Xintong Liu, Lin Huang, Dongyang Wang, Pengcheng Wang, Sixiang Chen

    Due to lightning strikes, electric current with high power density flows through the ground grid or driven rod of power distribution line towers to the soil, which may threaten the safety of aquatic organisms in nearby ponds. In engineering practice, there is a lack of an effective risk assessment method for aquatic organisms around earthing devices of power distribution networks under impulse current dissipation caused by lightning strikes. To solve this problem, a method to assess the safety of grass carp is proposed. First, based on a method of equivalent conduction, the conductivity of a typical grass carp is measured, and current threshold values causing different reactions in grass carp are observed and recorded. Then, the steps for risk assessment are given, with consideration given to the probability distribution characteristics of lightning current amplitude. Finally, some protective measures to reduce the threat of lightning current are given. The performances of different protection methods are analyzed based on a case in Foshan city. The results show that implementing protective measures can effectively reduce adverse reactions of grass carp in thunderstorm weather.