Laura Cervino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Laura Cervino has a total of 274 co-authors. Here are the top co-authors by number of shared publications:
S Jiang
Center for Advanced Radiotherapy Technologies, University of California, San Diego, La Jolla, CA
27 shared publicationsX Jia
Center for Advanced Radiotherapy Technologies, University of California, San Diego, La Jolla, CA
23 shared publicationsH Yan
Center for Advanced Radiotherapy Technologies, University of California, San Diego, La Jolla, CA
12 shared publicationsHao Yan
Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas 75235
11 shared publicationsY Graves
Center for Advanced Radiotherapy Technologies, University of California, San Diego, La Jolla, CA
8 shared publicationsSteve B. Jiang
Center for Advanced Radiotherapy Technologies and Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California 92037-0843 and Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas 75235
6 shared publications
Latest Publications
- 6 May 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (3) , 035022
A strategy of CT exam protocol to standardize groups of scanners using automated noise assessment and noise prediction for CT radiotherapy simulation
Objective. Standardizing clinical CT images enables consistent analysis of image data for target delineation, radiomics, and machine learning in personalized medicine. The process of managing the scanned protocols in various CT scanners for radiotherapy simulation is underexplored in the literature. This study uses noise evaluation and prediction models to harmonize CT protocols across scanner models and manufacturers, ensuring reliable data for radiotherapy planning. Approach. A global noise index (GNI) was calculated from 1581 clinical CT exams obtained on five scanners (three from vendor P and two from vendor S: S p and S c ). Exams were categorized by anatomical site. GNI was assessed (I) within the same model, (II) between models from the same manufacturer, and (III) across manufacturers. One-way ANOVA (I, III) and student t -tests (II) evaluated significance ( p < 0.05). Predictive models were created and validated with 90 further exams, establishing a reference GNI (GNI ref ) for future optimization. Results. GNI showed minor variations among P-type and between S p and S c scanners, but S scanners differed from P . Predictive model error ranged from 0.8 to 1.5 hounsfield units (HU). GNI differences between S and P scanners were S scanners had 1.5–2 HU higher GNI for the abdomen, pelvis, breast, and lungs. Conclusion. Scanners of the same model show slight variation; minor noise differences exist between manufacturers. Predictive modeling can estimate CT noise and support protocol optimization. The reference GNI of an anatomical site can be derived from sufficient CT exams, with or without the predictive mode; a 1–2 HU difference in GNI ref is achievable if the protocol is properly translated.
- 6 May 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (3) , 035022
A strategy of CT exam protocol to standardize groups of scanners using automated noise assessment and noise prediction for CT radiotherapy simulation
Objective. Standardizing clinical CT images enables consistent analysis of image data for target delineation, radiomics, and machine learning in personalized medicine. The process of managing the scanned protocols in various CT scanners for radiotherapy simulation is underexplored in the literature. This study uses noise evaluation and prediction models to harmonize CT protocols across scanner models and manufacturers, ensuring reliable data for radiotherapy planning. Approach. A global noise index (GNI) was calculated from 1581 clinical CT exams obtained on five scanners (three from vendor P and two from vendor S: S p and S c ). Exams were categorized by anatomical site. GNI was assessed (I) within the same model, (II) between models from the same manufacturer, and (III) across manufacturers. One-way ANOVA (I, III) and student t -tests (II) evaluated significance ( p < 0.05). Predictive models were created and validated with 90 further exams, establishing a reference GNI (GNI ref ) for future optimization. Results. GNI showed minor variations among P-type and between S p and S c scanners, but S scanners differed from P . Predictive model error ranged from 0.8 to 1.5 hounsfield units (HU). GNI differences between S and P scanners were S scanners had 1.5–2 HU higher GNI for the abdomen, pelvis, breast, and lungs. Conclusion. Scanners of the same model show slight variation; minor noise differences exist between manufacturers. Predictive modeling can estimate CT noise and support protocol optimization. The reference GNI of an anatomical site can be derived from sufficient CT exams, with or without the predictive mode; a 1–2 HU difference in GNI ref is achievable if the protocol is properly translated.
- 27 September 2025
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 124 (2) , 534-540
Gender Diversity in the American Association of Physicists in Medicine Annual Meeting: A 2017 Benchmark Analysis of Speakers and Moderators
- 27 September 2025
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 124 (2) , 534-540
Gender Diversity in the American Association of Physicists in Medicine Annual Meeting: A 2017 Benchmark Analysis of Speakers and Moderators
- Open Access
- 10 February 2024
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 29, 100547
Automated planning of stereotactic spine re-irradiation using cumulative dose limits
- 10 February 2024
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 29, 100547
Open AccessAutomated planning of stereotactic spine re-irradiation using cumulative dose limits
- Open Access
- 20 December 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (1) , e14216
Development of automated region of interest selection algorithms for surface‐guided radiation therapy of breast cancer
To investigate automation of the preparation of the region of interest (ROI) for surface‐guided radiotherapy (SGRT) of the whole breast with two algorithms based on contour anatomies: using the body contour, and using the breast contour. The patient dataset used for modeling consisted of 39 breast cancer patients previously treated with SGRT. The patient's anatomical structures (body and ipsilateral breast) were retrieved from the planning system, and the clinical ROI (cROI) drawn by the planners was retrieved from the SGRT system for comparison. For the body‐contour‐based algorithm, a convolutional neural network (MobileNet‐v2) was utilized to train a synthetic human model dataset to predict body joint locations. With the body joint location knowledge, an automated ROI (aROIbody) can be created based on: (1) the superior‐inferior (S‐I) borders defined by the joint locations, (2) the left‐right (L‐R) borders defined with 3/4 of chest width, and (3) a curation of the ROI to avoid the ipsilateral armpit. For the breast‐contour‐based algorithm, an aROIbreast was created by first defining the ROI in the S‐I direction with the ipsilateral breast boundaries. Other steps are the same as with the body‐contour‐based algorithm. Among the 39 patients, 24 patients were used to fine‐tune the algorithm parameters, and the remaining 15 patients were used to evaluate the quality of the aROIs against the cROIs. A blinded evaluation was performed by three SGRT expert physicists to rate the acceptability and the quality (1–10 scale) of the aROIs and cROIs, and the dice similarity coefficient (DSC) was also calculated to compare the similarity between the aROIs and cROIs. The results showed that the average acceptability was 14/15 (range: 13/15–15/15) for cROIs, 13.3/15 (range: 13/15–14/15) for aROIbody, and 14.6/15 (range: 14/15–15/15) for aROIbreast. The average quality was 7.4 ± 0.8 for cROIs, 8.1 ± 1.2 for aROIbody, and 8.2 ± 0.9 for aROIbreast. The DSC with cROIs was 0.81 ± 0.06 for aROIbody, and 0.83 ± 0.04 for aROIbreast. The ROI creation time was ∼120 s for clinical, 1.3 s for aROIbody, and 1.2 s for aROIbreast. The proposed automated algorithms can improve the ROI compliance with the SGRT protocol, with a shortened preparation time. It is ready to be integrated into the clinical workflow for automated ROI preparation.
- 20 December 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (1) , e14216
Open AccessDevelopment of automated region of interest selection algorithms for surface‐guided radiation therapy of breast cancer
To investigate automation of the preparation of the region of interest (ROI) for surface‐guided radiotherapy (SGRT) of the whole breast with two algorithms based on contour anatomies: using the body contour, and using the breast contour. The patient dataset used for modeling consisted of 39 breast cancer patients previously treated with SGRT. The patient's anatomical structures (body and ipsilateral breast) were retrieved from the planning system, and the clinical ROI (cROI) drawn by the planners was retrieved from the SGRT system for comparison. For the body‐contour‐based algorithm, a convolutional neural network (MobileNet‐v2) was utilized to train a synthetic human model dataset to predict body joint locations. With the body joint location knowledge, an automated ROI (aROIbody) can be created based on: (1) the superior‐inferior (S‐I) borders defined by the joint locations, (2) the left‐right (L‐R) borders defined with 3/4 of chest width, and (3) a curation of the ROI to avoid the ipsilateral armpit. For the breast‐contour‐based algorithm, an aROIbreast was created by first defining the ROI in the S‐I direction with the ipsilateral breast boundaries. Other steps are the same as with the body‐contour‐based algorithm. Among the 39 patients, 24 patients were used to fine‐tune the algorithm parameters, and the remaining 15 patients were used to evaluate the quality of the aROIs against the cROIs. A blinded evaluation was performed by three SGRT expert physicists to rate the acceptability and the quality (1–10 scale) of the aROIs and cROIs, and the dice similarity coefficient (DSC) was also calculated to compare the similarity between the aROIs and cROIs. The results showed that the average acceptability was 14/15 (range: 13/15–15/15) for cROIs, 13.3/15 (range: 13/15–14/15) for aROIbody, and 14.6/15 (range: 14/15–15/15) for aROIbreast. The average quality was 7.4 ± 0.8 for cROIs, 8.1 ± 1.2 for aROIbody, and 8.2 ± 0.9 for aROIbreast. The DSC with cROIs was 0.81 ± 0.06 for aROIbody, and 0.83 ± 0.04 for aROIbreast. The ROI creation time was ∼120 s for clinical, 1.3 s for aROIbody, and 1.2 s for aROIbreast. The proposed automated algorithms can improve the ROI compliance with the SGRT protocol, with a shortened preparation time. It is ready to be integrated into the clinical workflow for automated ROI preparation.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
On-board pseudo-MRI guidance for prostate radiotherapy on a conventional X-ray guided LINAC
Current target localization for prostate radiotherapy on a conventional LINAC consists of acquiring a cone-bean CT (CBCT) image and matching it to implanted fiducial markers inside the prostate due to poor soft-tissue contrast of CBCT. MRI provides better soft tissue contrast and no ionization radiation, but there are very few MR-LINACs, and conventional LINACs with x-ray imaging capabilities are much more ubiquitous. This study proposes to use prior MRI acquisitions, PCA motion modeling, and on-board CBCT from a conventional LINAC to obtain on-board pseudo-MRI for target localization in prostate radiotherapy.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
On-board pseudo-MRI guidance for prostate radiotherapy on a conventional X-ray guided LINAC
Current target localization for prostate radiotherapy on a conventional LINAC consists of acquiring a cone-bean CT (CBCT) image and matching it to implanted fiducial markers inside the prostate due to poor soft-tissue contrast of CBCT. MRI provides better soft tissue contrast and no ionization radiation, but there are very few MR-LINACs, and conventional LINACs with x-ray imaging capabilities are much more ubiquitous. This study proposes to use prior MRI acquisitions, PCA motion modeling, and on-board CBCT from a conventional LINAC to obtain on-board pseudo-MRI for target localization in prostate radiotherapy.
- Open Access
- 1 June 2023
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 27, 100452
Automatically tracking brain metastases after stereotactic radiosurgery
- 1 June 2023
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 27, 100452
Open AccessAutomatically tracking brain metastases after stereotactic radiosurgery
- 11 May 2023
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 116 (2) , 213-214
Hitting the Bamboo and Glass Ceilings in Academic Medicine
- 11 May 2023
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 116 (2) , 213-214
Hitting the Bamboo and Glass Ceilings in Academic Medicine
- Open Access
- 1 November 2021
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 111 (3) , S54-S55
Estimating Cumulative Radiation Dose to Organs at Risk for Glioblastoma Multiforme Cases via a Radiotherapy Dose Accumulation Routine
- 1 November 2021
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 111 (3) , S54-S55
Open AccessEstimating Cumulative Radiation Dose to Organs at Risk for Glioblastoma Multiforme Cases via a Radiotherapy Dose Accumulation Routine
- Open Access
- 19 November 2019
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 20 (12) , 70-77
A survey of surface imaging use in radiation oncology in the United States
Surface imaging (SI) has been rapidly integrated into radiotherapy clinics across the country without specific guidelines and recommendations on its commissioning and use aside from vendor‐provided information. A survey was created under the auspices of AAPM TG‐302 to assess the current status of SI to identify if there is need for formal guidance. The survey was designed to determine the institutional setting of responders, availability and length of its use, commissioning procedures, and clinical applications. This survey was created in REDCap, and approved as IRB exempt to collect anonymized data. Questions were reviewed by multiple physicists to ensure concept validity and piloted by a small group of independent physicists to ensure process validity. All full members of AAPM self‐identified as “therapy” or “other” were sent the survey link by email. The survey was active from February to March 2018. Of 3677 members successfully contacted, 439 completed responses; the summary of these responses provides insight on current surface imaging clinical practices, though they should not be assumed to be representative of radiation oncology as a whole. Results showed that 53.3% of respondents have SI in their clinics, mostly in treatment rooms, rarely in simulation rooms. Half of those without SI plan on purchasing it within 3 years. Over 10% have SI but do not use it clinically, 36.8% classify themselves as “expert” users, and 85.5% agreed/strongly agreed that SI guidelines are needed. Initial positioning with SI is most common for breast/chestwall and SRS/SBRT treatments, least common for pediatrics. Use of SI for intra‐fraction monitoring follows a similar distribution. Gating with SI is most prevalent for breast/chestwall (66.0%) but also used in SBRT (33.0%), and non‐SBRT lung/abdomen (<30%) treatments. SI is a rapidly growing technology in the field with widespread use for several anatomic sites. Guidelines and recommendations on commissioning and clinical use are warranted.
- 19 November 2019
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 20 (12) , 70-77
Open AccessA survey of surface imaging use in radiation oncology in the United States
Surface imaging (SI) has been rapidly integrated into radiotherapy clinics across the country without specific guidelines and recommendations on its commissioning and use aside from vendor‐provided information. A survey was created under the auspices of AAPM TG‐302 to assess the current status of SI to identify if there is need for formal guidance. The survey was designed to determine the institutional setting of responders, availability and length of its use, commissioning procedures, and clinical applications. This survey was created in REDCap, and approved as IRB exempt to collect anonymized data. Questions were reviewed by multiple physicists to ensure concept validity and piloted by a small group of independent physicists to ensure process validity. All full members of AAPM self‐identified as “therapy” or “other” were sent the survey link by email. The survey was active from February to March 2018. Of 3677 members successfully contacted, 439 completed responses; the summary of these responses provides insight on current surface imaging clinical practices, though they should not be assumed to be representative of radiation oncology as a whole. Results showed that 53.3% of respondents have SI in their clinics, mostly in treatment rooms, rarely in simulation rooms. Half of those without SI plan on purchasing it within 3 years. Over 10% have SI but do not use it clinically, 36.8% classify themselves as “expert” users, and 85.5% agreed/strongly agreed that SI guidelines are needed. Initial positioning with SI is most common for breast/chestwall and SRS/SBRT treatments, least common for pediatrics. Use of SI for intra‐fraction monitoring follows a similar distribution. Gating with SI is most prevalent for breast/chestwall (66.0%) but also used in SBRT (33.0%), and non‐SBRT lung/abdomen (<30%) treatments. SI is a rapidly growing technology in the field with widespread use for several anatomic sites. Guidelines and recommendations on commissioning and clinical use are warranted.