Sumit Singhal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sumit Singhal has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Debabrata Goswami
Indian Institute of Technology Kanpur, Kanpur, India
7 shared publications Arup Banerjee
2 shared publicationsSonaly Goswami
2 shared publicationsBarnabás Gilicze
ELI-HU Non-profit Ltd
1 shared publicationDipak Kumar Das
1 shared publicationFerenc Sarlós
1 shared publication
Latest Publications
- 17 December 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (26) , 53851-53866
Rapid-scan pulse-shaper-assisted two-dimensional electronic spectroscopy of Photosystem I using high-repetition-rate supercontinuum pulses
An ultrafast optical spectrometer is constructed, relying on a Yb fiber-based few-cycle laser system to generate high-repetition-rate (100 kHz) pulses and employing white-light supercontinuum in a pump-probe beam configuration for transient absorption spectroscopy (TAS) and two-dimensional electronic spectroscopy (2DES). The instrument benefits from shot-to-shot pulse shaping and detection for a reduced background noise, improving the sensitivity of the method and the ability to record TAS and 2DES with low pulse energies and short acquisition time, which can be critical for measuring the dynamics of biological systems. The practical applicability of the instrument is demonstrated by performing TAS and 2DES on trimeric Photosystem I complexes, isolated from the cyanobacterium T. vulcanus . It is also shown that rich, biophysically relevant information can be extracted from the combination of short TAS and 2DES measurements. The approach is employed to ascertain the main timescales of transfer and trapping of excitations among different Chl pools in the T. vulcanus PSI.
- 17 December 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (26) , 53851-53866
Rapid-scan pulse-shaper-assisted two-dimensional electronic spectroscopy of Photosystem I using high-repetition-rate supercontinuum pulses
An ultrafast optical spectrometer is constructed, relying on a Yb fiber-based few-cycle laser system to generate high-repetition-rate (100 kHz) pulses and employing white-light supercontinuum in a pump-probe beam configuration for transient absorption spectroscopy (TAS) and two-dimensional electronic spectroscopy (2DES). The instrument benefits from shot-to-shot pulse shaping and detection for a reduced background noise, improving the sensitivity of the method and the ability to record TAS and 2DES with low pulse energies and short acquisition time, which can be critical for measuring the dynamics of biological systems. The practical applicability of the instrument is demonstrated by performing TAS and 2DES on trimeric Photosystem I complexes, isolated from the cyanobacterium T. vulcanus . It is also shown that rich, biophysically relevant information can be extracted from the combination of short TAS and 2DES measurements. The approach is employed to ascertain the main timescales of transfer and trapping of excitations among different Chl pools in the T. vulcanus PSI.
- 5 November 2019
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (3) , 929-938
Unraveling the molecular dependence of femtosecond laser-induced thermal lens spectroscopy in fluids
Fluid systems exhibit thermal lens effects due to laser irradiation accompanied by convection and in contrast primarily conductive heat dissipation is observed in solids. The presence of a significant convective mode modifies the temperature gradient in fluids resulting in a deviation of the experimental results from theories that are based on pure conduction. Herein, we present a carefully designed femtosecond laser experiment that keeps the heat generation process constant in order to account for the effect of molecular properties on thermal dissipation. We derive a theoretical model that introduces and characterizes the additional convective heat transfer in thermal lens (TL) spectroscopy which explains our observed experimental results. We measured the TL signal for a series of liquid aliphatic alkanes, ranging from hexane to decane, and their comparison has proven the validity of our model. The influence of convective heat transfer on the TL signal is predicted in terms of the dimensionless Peclet number (PE). The lower values of PE for alkanes with longer carbon chains indicate that the convective flow of heat slows down substantially for larger molecules.
- 5 November 2019
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (3) , 929-938
Unraveling the molecular dependence of femtosecond laser-induced thermal lens spectroscopy in fluids
Fluid systems exhibit thermal lens effects due to laser irradiation accompanied by convection and in contrast primarily conductive heat dissipation is observed in solids. The presence of a significant convective mode modifies the temperature gradient in fluids resulting in a deviation of the experimental results from theories that are based on pure conduction. Herein, we present a carefully designed femtosecond laser experiment that keeps the heat generation process constant in order to account for the effect of molecular properties on thermal dissipation. We derive a theoretical model that introduces and characterizes the additional convective heat transfer in thermal lens (TL) spectroscopy which explains our observed experimental results. We measured the TL signal for a series of liquid aliphatic alkanes, ranging from hexane to decane, and their comparison has proven the validity of our model. The influence of convective heat transfer on the TL signal is predicted in terms of the dimensionless Peclet number (PE). The lower values of PE for alkanes with longer carbon chains indicate that the convective flow of heat slows down substantially for larger molecules.
- Open Access
- 24 January 2019
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 4 (1) , 1889-1896
Thermal Lens Study of NIR Femtosecond Laser-Induced Convection in Alcohols
We use time-resolved thermal lens (TL) experiments to examine the convective heat transfer at microscale in the first eight members of the homologous series of primary alcohols. TL measurements enable a direct study of these primary alcohols without adding any chromophore as a function of varying heat loads created via femtosecond laser pulses at 1560 nm. Convective heat transfer leads to the asymmetrical and reduced thermal gradient, which substantially weakens the TL signal. The inflection in the time profile of the TL signal of methanol at higher powers is attributed to the greater molecular convection in methanol compared to other samples. This inflection dies out with a decrease in laser power. Our results demonstrate that the convection is more prominent at higher laser powers in all samples, and it modifies the trend in the steady-state TL signal of different alcohols with pump laser power. Methanol also has the highest steady-state TL among the primary alcohol series at low laser powers. The maxima in the TL signal are shifted systematically from methanol to ethanol and then to propanol as the laser power increases. Semiempirical analysis of time-resolved TL signal by using the latest theoretical TL model enabled us to extract the coefficient of convective heat transfer in methanol at different laser powers. In addition to that, analysis of other members of alcohol series at the highest (7.3 mW) laser power shows that convection is more facile in short-chain alcohols compared to the long-chain alcohols.
- 24 January 2019
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 4 (1) , 1889-1896
Open AccessThermal Lens Study of NIR Femtosecond Laser-Induced Convection in Alcohols
We use time-resolved thermal lens (TL) experiments to examine the convective heat transfer at microscale in the first eight members of the homologous series of primary alcohols. TL measurements enable a direct study of these primary alcohols without adding any chromophore as a function of varying heat loads created via femtosecond laser pulses at 1560 nm. Convective heat transfer leads to the asymmetrical and reduced thermal gradient, which substantially weakens the TL signal. The inflection in the time profile of the TL signal of methanol at higher powers is attributed to the greater molecular convection in methanol compared to other samples. This inflection dies out with a decrease in laser power. Our results demonstrate that the convection is more prominent at higher laser powers in all samples, and it modifies the trend in the steady-state TL signal of different alcohols with pump laser power. Methanol also has the highest steady-state TL among the primary alcohol series at low laser powers. The maxima in the TL signal are shifted systematically from methanol to ethanol and then to propanol as the laser power increases. Semiempirical analysis of time-resolved TL signal by using the latest theoretical TL model enabled us to extract the coefficient of convective heat transfer in methanol at different laser powers. In addition to that, analysis of other members of alcohol series at the highest (7.3 mW) laser power shows that convection is more facile in short-chain alcohols compared to the long-chain alcohols.
- 19 January 2017
- Published by Optica Publishing Group in Applied Optics
- Vol. 56 (3) , 644-648
Measurement of pure optical nonlinearity in carbon disulfide with a high-repetition-rate femtosecond laser
Using the close-aperture Z-scan technique, the pure nonlinear refractive index () of carbon disulfide is measured with a 76 MHz repetition rate femtosecond laser. Strong interference of thermal effects exists with high-repetition-rate lasers that result in negative values of . We remove the thermal effect completely by continuously increasing the sample flow rate () in a sample cell as indicated by the change in sign of from negative to positive. The positive value of is due to Kerr-type nonlinearity. At sufficiently high values of of >25 ml/min, all thermal effects are removed, resulting in an value that matches low-repetition-rate experiments.- 19 January 2017
- Published by Optica Publishing Group in Applied Optics
- Vol. 56 (3) , 644-648
Measurement of pure optical nonlinearity in carbon disulfide with a high-repetition-rate femtosecond laser
Using the close-aperture Z-scan technique, the pure nonlinear refractive index () of carbon disulfide is measured with a 76 MHz repetition rate femtosecond laser. Strong interference of thermal effects exists with high-repetition-rate lasers that result in negative values of . We remove the thermal effect completely by continuously increasing the sample flow rate () in a sample cell as indicated by the change in sign of from negative to positive. The positive value of is due to Kerr-type nonlinearity. At sufficiently high values of of >25 ml/min, all thermal effects are removed, resulting in an value that matches low-repetition-rate experiments.- 1 January 2015
- Published by Optica Publishing Group
- p. FTu5E.5
Importance of Hydrogen Bonding in Thermal Lens Study of Highly Absorbing Liquids
Effect of thermal load on highly absorbing hydrogen bonded liquids are explored. We find heat transfer is better facilitated in lesser hydrogen bonded liquids by convection through molecular motion in addition to conduction.
- 1 January 2015
- Published by Optica Publishing Group
- p. FTu5E.5
Importance of Hydrogen Bonding in Thermal Lens Study of Highly Absorbing Liquids
Effect of thermal load on highly absorbing hydrogen bonded liquids are explored. We find heat transfer is better facilitated in lesser hydrogen bonded liquids by convection through molecular motion in addition to conduction.
- 1 July 2013
- Published by Elsevier in Chemical Physics Letters
- Vol. 579, 45-50
Polarization induced control of multiple fluorescence from a molecule
- 1 July 2013
- Published by Elsevier in Chemical Physics Letters
- Vol. 579, 45-50
Polarization induced control of multiple fluorescence from a molecule