David Graham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David Graham has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- David G. Lloyd
Australian Centre for Precision Health and Technology (PRECISE), Griffith University
5 shared publications - Rod S. Barrett
Griffith University
5 shared publications Christopher P. Carty
School of Allied Health Sciences and Menzies Health Institute Queensland, Griffith University, Queensland, Australia
3 shared publications- Justin Whitten
Food Systems, Nutrition & Kinesiology, Montana State University , Bozeman, MT 59715
3 shared publications - Christopher P. Carty
Australian Centre for Precision Health and Technology (PRECISE), Griffith University, Gold Coast, QLD, Australia; School of Medicine and Dentistry, Griffith University, QLD, Australia; Department of Orthopedics, Children's Health Queensland Hospital and Health Service, QLD, Australia
2 shared publications - Luca Modenese
Graduate School of Biomedical Engineering, University of New South Wales
2 shared publications
Latest Publications
- Open Access
- 10 December 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 195, 113120
Effect of neural mode on model estimates of muscle contributions to knee loading in individuals with anterior cruciate ligament reconstruction
- 10 December 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 195, 113120
Open AccessEffect of neural mode on model estimates of muscle contributions to knee loading in individuals with anterior cruciate ligament reconstruction
- 30 May 2024
- Published by ASME International in Journal of Medical Devices
- Vol. 18 (2) , 021005
Design, Fabrication, and Validation of a Portable Perturbation Treadmill for Balance Recovery Research
Trips and falls are a major concern for older adults. The resulting injury and loss of mobility can have a significant impact on quality of life. An emerging field of study, known as Perturbation Training, has been shown to reduce injury rates associated with trips and falls in older adults. Treadmills traditionally used for Perturbation Training are large, expensive, and immobile, forcing users to travel long distances to receive care. A portable treadmill would serve a larger portion of the at-risk population than current methods. We developed a portable, low-cost, twin-belt perturbation treadmill capable of high-intensity Perturbation Training. Belt speeds are controlled by a custom mechanical and software interface, allowing operators with no programming experience to control the device. The treadmill can accommodate users up to 118 kg and provides a maximum acceleration and speed of 12 m/s2 and 3.3 m/s, respectively, under full load. The total weight is 180 kg, and the treadmill can be moved like a wheelbarrow, with handles in the back and wheels in the front. The prototype was validated with mechanical and human participant testing, showing it as a viable device for Perturbation Training. In this paper, we will go over the design, fabrication, and validation processes used to create the Portable Perturbation Treadmill.
- 30 May 2024
- Published by ASME International in Journal of Medical Devices
- Vol. 18 (2) , 021005
Design, Fabrication, and Validation of a Portable Perturbation Treadmill for Balance Recovery Research
Trips and falls are a major concern for older adults. The resulting injury and loss of mobility can have a significant impact on quality of life. An emerging field of study, known as Perturbation Training, has been shown to reduce injury rates associated with trips and falls in older adults. Treadmills traditionally used for Perturbation Training are large, expensive, and immobile, forcing users to travel long distances to receive care. A portable treadmill would serve a larger portion of the at-risk population than current methods. We developed a portable, low-cost, twin-belt perturbation treadmill capable of high-intensity Perturbation Training. Belt speeds are controlled by a custom mechanical and software interface, allowing operators with no programming experience to control the device. The treadmill can accommodate users up to 118 kg and provides a maximum acceleration and speed of 12 m/s2 and 3.3 m/s, respectively, under full load. The total weight is 180 kg, and the treadmill can be moved like a wheelbarrow, with handles in the back and wheels in the front. The prototype was validated with mechanical and human participant testing, showing it as a viable device for Perturbation Training. In this paper, we will go over the design, fabrication, and validation processes used to create the Portable Perturbation Treadmill.
- Open Access
- 1 January 2024
- Published by SAGE Publications in Gerontology and Geriatric Medicine
- Vol. 10
The Acceptability of a Community-Based Perturbation-Based Balance Training to Older Adults and Healthcare Professionals
Background: Perturbation-based balance training (PBT) is a promising fall risk reduction method that involves inducing unexpected perturbations to balance to train participants reactive balance control. Due to the unpredictable nature of PBT, its acceptability to older adults could present a barrier to the implementation of PBT in the community. Aim/Purpose: The purpose of this study was to assess the perceived acceptability of a community-based PBT program to both older adults and healthcare professionals (HCPs). Methods: Nineteen older adults (aged 69.6 ± 6.6 years, 17 women, 2 men) and three HCPs participated in the qualitative study. Participants completed four PBT sessions facilitated in conjunction with HCPs. Interviews, based on the theoretical framework of acceptability, were conducted before and after PBT and analyzed using template analysis. Results: PBT was perceived as effective by older adults and HCPs. However, HCPs perceived the equipment cost as a substantial barrier to feasibility in the community.
- 1 January 2024
- Published by SAGE Publications in Gerontology and Geriatric Medicine
- Vol. 10
Open AccessThe Acceptability of a Community-Based Perturbation-Based Balance Training to Older Adults and Healthcare Professionals
Background: Perturbation-based balance training (PBT) is a promising fall risk reduction method that involves inducing unexpected perturbations to balance to train participants reactive balance control. Due to the unpredictable nature of PBT, its acceptability to older adults could present a barrier to the implementation of PBT in the community. Aim/Purpose: The purpose of this study was to assess the perceived acceptability of a community-based PBT program to both older adults and healthcare professionals (HCPs). Methods: Nineteen older adults (aged 69.6 ± 6.6 years, 17 women, 2 men) and three HCPs participated in the qualitative study. Participants completed four PBT sessions facilitated in conjunction with HCPs. Interviews, based on the theoretical framework of acceptability, were conducted before and after PBT and analyzed using template analysis. Results: PBT was perceived as effective by older adults and HCPs. However, HCPs perceived the equipment cost as a substantial barrier to feasibility in the community.
- 1 January 2023
- Published by Human Kinetics in Journal of Aging and Physical Activity
- Vol. -1 (aop) , 1-6
Baseline Measures of Physical Activity and Function Do Not Predict Future Fall Incidence in Sedentary Older Adults: A Prospective Cohort Study
Physical activity (PA) and physical function (PF) are modifiable risk factors for falls in older adults, but their ability to predict future fall incidence is unclear. The purpose of this study was to determine the predictive ability of baseline measures of PA, PF, and lower limb strength on future falls. A total of 104 participants underwent baseline assessments of PA, PF, and lower limb strength. Falls were monitored prospectively for 12 months. Eighteen participants fell at least once during the 12-month follow-up. Participants recorded almost exclusively sedentary levels of activity. PA, PF, and lower limb strength did not differ between fallers and nonfallers. Twelve participants, who reported a minor musculoskeletal injury in the past 6 months, experienced a fall. The results of this study suggest that in a cohort of highly functioning, sedentary older adults, PA does not distinguish fallers from nonfallers and that the presence of a recent musculoskeletal injury appears to be a possible risk factor for falling.
- 1 January 2023
- Published by Human Kinetics in Journal of Aging and Physical Activity
- Vol. -1 (aop) , 1-6
Baseline Measures of Physical Activity and Function Do Not Predict Future Fall Incidence in Sedentary Older Adults: A Prospective Cohort Study
Physical activity (PA) and physical function (PF) are modifiable risk factors for falls in older adults, but their ability to predict future fall incidence is unclear. The purpose of this study was to determine the predictive ability of baseline measures of PA, PF, and lower limb strength on future falls. A total of 104 participants underwent baseline assessments of PA, PF, and lower limb strength. Falls were monitored prospectively for 12 months. Eighteen participants fell at least once during the 12-month follow-up. Participants recorded almost exclusively sedentary levels of activity. PA, PF, and lower limb strength did not differ between fallers and nonfallers. Twelve participants, who reported a minor musculoskeletal injury in the past 6 months, experienced a fall. The results of this study suggest that in a cohort of highly functioning, sedentary older adults, PA does not distinguish fallers from nonfallers and that the presence of a recent musculoskeletal injury appears to be a possible risk factor for falling.
- Open Access
- 25 October 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (10) , e0185564
Muscle contributions to the acceleration of the whole body centre of mass during recovery from forward loss of balance by stepping in young and older adults
The purpose of this study was to determine the muscular contributions to the acceleration of the whole body centre of mass (COM) of older compared to younger adults that were able to recover from forward loss of balance with a single step. Forward loss of balance was achieved by releasing participants (14 older adults and 6 younger adults) from a static whole-body forward lean angle of approximately 18 degrees. 10 older adults and 6 younger adults were able to recover with a single step and included in subsequent analysis. A scalable anatomical model consisting of 36 degrees-of-freedom was used to compute kinematics and joint moments from motion capture and force plate data. Forces for 92 muscle actuators were computed using Static Optimisation and Induced Acceleration Analysis was used to compute individual muscle contributions to the three-dimensional acceleration of the whole body COM. There were no significant differences between older and younger adults in step length, step time, 3D COM accelerations or muscle contributions to 3D COM accelerations. The stance and stepping leg Gastrocnemius and Soleus muscles were primarily responsible for the vertical acceleration experienced by the COM. The Gastrocnemius and Soleus from the stance side leg together with bilateral Hamstrings accelerated the COM forwards throughout balance recovery while the Vasti and Soleus of the stepping side leg provided the majority of braking accelerations following foot contact. The Hip Abductor muscles provided the greatest contribution to medial-lateral accelerations of the COM. Deficits in the neuromuscular control of the Gastrocnemius, Soleus, Vasti and Hip Abductors in particular could adversely influence balance recovery and may be important targets in interventions to improve balance recovery performance.
- 25 October 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (10) , e0185564
Open AccessMuscle contributions to the acceleration of the whole body centre of mass during recovery from forward loss of balance by stepping in young and older adults
The purpose of this study was to determine the muscular contributions to the acceleration of the whole body centre of mass (COM) of older compared to younger adults that were able to recover from forward loss of balance with a single step. Forward loss of balance was achieved by releasing participants (14 older adults and 6 younger adults) from a static whole-body forward lean angle of approximately 18 degrees. 10 older adults and 6 younger adults were able to recover with a single step and included in subsequent analysis. A scalable anatomical model consisting of 36 degrees-of-freedom was used to compute kinematics and joint moments from motion capture and force plate data. Forces for 92 muscle actuators were computed using Static Optimisation and Induced Acceleration Analysis was used to compute individual muscle contributions to the three-dimensional acceleration of the whole body COM. There were no significant differences between older and younger adults in step length, step time, 3D COM accelerations or muscle contributions to 3D COM accelerations. The stance and stepping leg Gastrocnemius and Soleus muscles were primarily responsible for the vertical acceleration experienced by the COM. The Gastrocnemius and Soleus from the stance side leg together with bilateral Hamstrings accelerated the COM forwards throughout balance recovery while the Vasti and Soleus of the stepping side leg provided the majority of braking accelerations following foot contact. The Hip Abductor muscles provided the greatest contribution to medial-lateral accelerations of the COM. Deficits in the neuromuscular control of the Gastrocnemius, Soleus, Vasti and Hip Abductors in particular could adversely influence balance recovery and may be important targets in interventions to improve balance recovery performance.
- Open Access
- 1 May 2017
- Published by Elsevier in Gait & Posture
- Vol. 54, 325-331
Reliability of four models for clinical gait analysis
- 1 May 2017
- Published by Elsevier in Gait & Posture
- Vol. 54, 325-331
Open AccessReliability of four models for clinical gait analysis
- Open Access
- 1 September 2016
- Published by Elsevier in Journal of Biomechanics
- Vol. 49 (13) , 2619-2624
Hip joint contact loads in older adults during recovery from forward loss of balance by stepping
- 1 September 2016
- Published by Elsevier in Journal of Biomechanics
- Vol. 49 (13) , 2619-2624
Open AccessHip joint contact loads in older adults during recovery from forward loss of balance by stepping
- 1 June 2015
- Published by Elsevier in Experimental Gerontology
- Vol. 66, 39-46
Biomechanical predictors of maximal balance recovery performance amongst community-dwelling older adults
- 1 June 2015
- Published by Elsevier in Experimental Gerontology
- Vol. 66, 39-46
Biomechanical predictors of maximal balance recovery performance amongst community-dwelling older adults
- 1 February 2014
- Published by Elsevier in Journal of Biomechanics
- Vol. 47 (3) , 667-674
Muscle contributions to recovery from forward loss of balance by stepping
- 1 February 2014
- Published by Elsevier in Journal of Biomechanics
- Vol. 47 (3) , 667-674
Muscle contributions to recovery from forward loss of balance by stepping
- Open Access
- 5 December 2013
- Published by Springer Nature in SpringerPlus
- Vol. 2 (1) , 1-10
Effect of microtitanium impregnated tape on the recovery of triceps surae musculotendinous function following strenuous running
We previously reported increased running economy and joint range of motion (ROM) during subsequent exercise performed 48-h following strenuous exercise while wearing garments containing micro-titanium particles generated from high-pressure aqueous processing of titanium (AQUA TITANTM). Here we utilised an isolated plantarflexion triceps surae model and AQUA TITAN-treated flexible tape to determine if dermal application of the micro-titanium could account for meaningful changes in functional properties of the musculotendinous unit. In a randomised double-blind crossover, 20 trained men day 1, baseline measures, AQUA TITAN or placebo tape covering the triceps surae, intermittent high-intensity treadmill running; day 2, rest; day 3, post-stress post-treatment outcome measures. Outcomes comprised: plantarflexion ROM via isokinetic dynamometry; short latency reflex from electromyography; Achilles tendon stiffness from isometric dynamometry, ultrasonography (Achilles-medial-gastrocnemius junction), motion analysis, and force-length modelling. High-intensity exercise with placebo tape reduced tendon stiffness (-16.5%; 95% confidence limits ±8.1%; small effect size), relative to non-taped baseline, but this effect was negligible (-5.9%; ±9.2%) with AQUA TITAN (AQUA TITAN-placebo difference -11.3%; ±11.6%). Change in latency relative to baseline was trivial with placebo (1.6%; ±3.8%) but large with AQUA TITAN (-11.3%; ±3.3%). The effects on ROM with AQUA TITAN (1.6%; ±2.0%) and placebo were trivial (-1.6% ±1.9%), but the small difference (3.1%; ±2.7%) possibly greater with AQUA TITAN. AQUA TITAN tape accelerated the reflex response and attenuated reduced Achilles tendon stiffness following fatiguing exercise. Altered neuromuscular control of tendon stiffness via dermal application of micro-titanium treated materials may facilitate restoration of musculotendinous contractile performance following prior strenuous exercise.
- 5 December 2013
- Published by Springer Nature in SpringerPlus
- Vol. 2 (1) , 1-10
Open AccessEffect of microtitanium impregnated tape on the recovery of triceps surae musculotendinous function following strenuous running
We previously reported increased running economy and joint range of motion (ROM) during subsequent exercise performed 48-h following strenuous exercise while wearing garments containing micro-titanium particles generated from high-pressure aqueous processing of titanium (AQUA TITANTM). Here we utilised an isolated plantarflexion triceps surae model and AQUA TITAN-treated flexible tape to determine if dermal application of the micro-titanium could account for meaningful changes in functional properties of the musculotendinous unit. In a randomised double-blind crossover, 20 trained men day 1, baseline measures, AQUA TITAN or placebo tape covering the triceps surae, intermittent high-intensity treadmill running; day 2, rest; day 3, post-stress post-treatment outcome measures. Outcomes comprised: plantarflexion ROM via isokinetic dynamometry; short latency reflex from electromyography; Achilles tendon stiffness from isometric dynamometry, ultrasonography (Achilles-medial-gastrocnemius junction), motion analysis, and force-length modelling. High-intensity exercise with placebo tape reduced tendon stiffness (-16.5%; 95% confidence limits ±8.1%; small effect size), relative to non-taped baseline, but this effect was negligible (-5.9%; ±9.2%) with AQUA TITAN (AQUA TITAN-placebo difference -11.3%; ±11.6%). Change in latency relative to baseline was trivial with placebo (1.6%; ±3.8%) but large with AQUA TITAN (-11.3%; ±3.3%). The effects on ROM with AQUA TITAN (1.6%; ±2.0%) and placebo were trivial (-1.6% ±1.9%), but the small difference (3.1%; ±2.7%) possibly greater with AQUA TITAN. AQUA TITAN tape accelerated the reflex response and attenuated reduced Achilles tendon stiffness following fatiguing exercise. Altered neuromuscular control of tendon stiffness via dermal application of micro-titanium treated materials may facilitate restoration of musculotendinous contractile performance following prior strenuous exercise.