Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Haitao Yang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Research on Risk Assessment Method for Urban Dense Cable Trenches Based on Improved Arrhenius Formula and Spatial Inversion Algorithm

    by Shuai Zheng, Zhensheng Wu, Hao Wu, Zhongli Zhang, Haitao Yang

    In view of the complex scenarios of multisource risk coupling and strong spatial heterogeneity in urban dense cable trenches, this article proposes a comprehensive risk assessment method that integrates the improved Arrhenius formula and spatial inversion algorithm. The primary hypothesis is that by combining continuous degradation modeling with spatially constrained physical-field reconstruction, the overall risk of cable trenches can be accurately quantified and visualized. Methodologically, a benchmark weight system for 12 core risk factors is first established using the fuzzy analytic hierarchy process (AHP), with consistency validation ensuring logical rigor. For time- and dose-dependent degradation factors, an improved Arrhenius continuous trigger function is introduced to replace traditional discrete risk representations with a differentiable, fitting-enabled model. Spatially, under the constraints of trench geometry and physics, kernel function interpolation is employed to achieve global reconstruction from sparse sensor data. This enables precise spatial inversion for risk localization. The techniques and tools applied include fuzzy AHP for weight determination, modified Arrhenius functions for degradation modeling, and kernel-based interpolation algorithms for field reconstruction. Validation on actual dense cable trench cases demonstrates that the method comprehensively covers all 12 risk factors, with model fitting accuracy exceeding 0.9. Results show effective identification of risk centers and classification of risk levels, providing operational guidance for maintenance. In conclusion, this approach offers a deployable, interpretable framework for enhancing the safety and resilience of urban distribution networks by enabling continuous risk visualization and precise hazard localization.

  • Open Access

    Enhanced Dielectric Response and Electric Field-Sensing Properties of PDMS Composites by Graphene/Nitride Heterojunctions: Insights from Experiment and DFT

    by Bo Li, Jiao Sun, Yuxing Lei, Tingting Jiang, Haitao Yang

    Flexible dielectric composite materials capable of converting power frequency electric fields into measurable electrical signals are of great significance in the field of non-contact electric field sensing in power systems. In this paper, graphene/nitride heterojunction powders were prepared using three representative nitrides (AlN, BN, and Si3N4) and embedded in polydimethylsiloxane (PDMS) to prepare flexible composite films with a fixed filler content of 5.0 wt%. Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) confirmed the successful formation of the heterojunctions. The results showed that the nitride-related elements (Al, Si and N) were spatially correlated with the graphene-rich regions, thus providing abundant interfacial contact sites. Dielectric spectroscopy (50 Hz–50 kHz) showed that all samples exhibited typical dispersive behavior, with the real part of the dielectric constant decreasing monotonically with increasing frequency, and the loss tangent also decreasing smoothly. Under a 50 Hz parallel-plate electric field, the normalized induced voltage amplitude (PDMS = 1) increases to 1.070 (≈7.0%) for G/PDMS, and further to 1.0723–1.07447 (≈7.23–7.45%) for AlN–G/PDMS, BN–G/PDMS, and Si3N4-G/PDMS. DFT calculations confirm that the graphene/nitride interface has a stable structure with negative binding energies (−2.241, −1.773, and −3.062 eV for AlN–G, BN–G, and Si3N4–G, respectively). Significant charge redistribution and Mulliken charge transfer (0.0538, 0.2047, and 0.0244 eV, respectively) are present at the interface, accompanied by Fermi level density of states modulation and a small bandgap opening (~0.101 eV) in BN–G. These results collectively support the interfacial polarization-driven mechanism and provide a comparative basis for selecting nitride components in graphene-based heterojunction fillers in flexible dielectric electric field-sensing layers.


  • Open Access

    Graphene/Chalcogenide Heterojunctions for Enhanced Electric-Field-Sensitive Dielectric Performance: Combining DFT and Experimental Study

    by Bo Li, Nanhui Zhang, Yuxing Lei, Mengmeng Zhu, Haitao Yang

    Electric-field-sensitive dielectrics play a crucial role in electric field induction sensing and related capacitive conversion, with interfacial polarization and charge accumulation largely determining the signal output. This paper introduces graphene/transition metal dichalcogenide (TMD) (MoSe2, MoS2, and WS2) heterojunctions as functional fillers to enhance the dielectric response and electric-field-induced voltage output of flexible polydimethylsiloxane (PDMS) composites. Density functional theory (DFT) calculations were used to evaluate the stability of the heterojunctions and interfacial electronic modulation, including binding behavior, charge redistribution, and Fermi level-referenced band structure/total density of states (TDOS) characteristics. The calculations show that the graphene/TMD interface is primarily controlled by van der Waals forces, exhibiting negative binding energy and significant interfacial charge rearrangement. Based on these theoretical results, graphene/TMD heterojunction powders were synthesized and incorporated into polydimethylsiloxane (PDMS). Structural characterization confirmed the presence of face-to-face interfacial contacts and consistent elemental co-localization within the heterojunction filler. Dielectric spectroscopy analysis revealed an overall improvement in the dielectric constant of the composite materials while maintaining a stable loss trend within the studied frequency range. More importantly, calibrated electric field induction tests (based on pure PDMS) showed a significant enhancement in the voltage response of all heterojunction composite materials, with the WS2-G/PDMS system exhibiting the best performance, exhibiting an electric-field-induced voltage amplitude 7.607% higher than that of pure PDMS. This work establishes a microscopic-to-macroscopic correlation between interfacial electronic modulation and electric-field-sensitive dielectric properties, providing a feasible interface engineering strategy for high-performance flexible dielectric sensing materials.


  • Open Access

    Enhancing the Electric Field-Induced Response of Graphene with Metal Oxides: Experimental and DFT Study

    by Yuxing Lei, Bo Li, Mengyao Zhu, Jiao Sun, Haitao Yang

    The potential of graphene for electric field sensing is limited by its zero bandgap. This study employs a combined first-principles and experimental approach to enhance its response via heterojunctions with ZnO, SnO2, and Al2O3. Calculations reveal spontaneous formation and interfacial charge transfer in all systems, with SnO2/graphene exhibiting the most significant charge transfer (0.3636 e) and inducing a finite bandgap (0.017–0.064 eV). Experimentally, SnO2-graphene/PDMS composites demonstrated the highest relative permittivity (3.19) and a 7.76% increase in normalized induced voltage over pure PDMS within 50 Hz–50 kHz. This work establishes a direct correlation between interfacial charge transfer, bandgap opening, and macroscopic dielectric enhancement, identifying SnO2/graphene as the optimal heterojunction. The integrated multi-scale methodology provides a clear design principle for high-performance, graphene-based field-sensitive materials.


  • Open Access

    Effective Tuning of the Performance of Conductive Silicon Compound by Few-Layered Graphene Additives

    by Zhensheng Wu, Haitao Yang, Fuqiang Tian, Hao Ren, Yu Chen

    Electric conductive silicon compounds are widely used and essential in electric power, energy and information industries. However, there are still problems such as insufficient stability of physical and chemical properties and weak electrical conductivity. To address the problem of low contact reliability of electrical joints in high-power transmission and distribution equipment, we assessed the influence of mechanically exfoliated graphene (MEG) content on the physicochemical properties of electrical joint compound (EJC). Varying amounts of few-layer MEG prepared with the conventional mechanically exfoliated method was added to the conductive silicon compounds, of which various physicochemical properties, such as penetration, drip point, volume resistivity and frictional properties were systematically assessed and compared with those with copper additive. We found that the addition of MEG effectively enhanced the temperature and mechanical stability of EJC and significantly reduced the material volume resistivity. This work paves the way to improve the key performance of electric conductive silicon compounds with advanced nanomaterials.


  • Open Access

    Analysis of the Influence of Silicone Rubber Aging on the Transmission Parameters of Terahertz Waves

    by Haitao Yang, Zhensheng Wu, Weinan Dong, Junpeng Dang, Hao Ren

    In this study, a method for testing the aging of silicone rubber insulators using terahertz waves in the 0.17–0.22 THz frequency band is proposed, aiming at the problem of online non-destructive testing of the aging degree of composite insulators. The relationship between the aging degree of silicone rubber composite insulators and the relative dielectric constant was studied through first-principles calculations and molecular chain scission models. In addition, the electromagnetic model of the terahertz signal incident on the silicon rubber sheet was simulated and the relationship between the aging degree of the silicon rubber and the terahertz input return loss was obtained. Eleven insulator samples with different degrees of aging were selected. In these samples, the degree of aging was calibrated according to the degree of surface deterioration and the average partial discharge voltage. The terahertz return loss measurement experiment was performed after that. Finally, the results of experiment and calculation simulation were compared and the reliability of the relationship between the aging degree of the silicone rubber insulator and the terahertz input return loss was verified.