Ramin Jahadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ramin Jahadi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Hamid Jahed
Fatigue and Stress Analysis Laboratory (FATSLab), Department of Mechanical & Mechatronics Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
2 shared publications - Ali Tofangsaz1 shared publication
- Hamid Beheshti
University of Isfahan
1 shared publication M. Sedighi
School of Mechanical Engineering, Iran University of Science & Technology, Tehran, Iran
1 shared publication- Mohammad Heidari-Rarani
Department of Mechanical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran
1 shared publication Mohammad Sedighi
1 shared publication
Latest Publications
- 3 April 2023
- Published by Taylor & Francis in Mechanics of Advanced Materials and Structures
- Vol. 31 (18) , 4295-4308
A micromechanical damage-healing model for encapsulation-based self-healing polymer composites under tensile loading
In this study, a novel micromechanics-based damage model is proposed for the damage evolution of a two-component microencapsulated-based self-healing polymer composite. In this way, a representative volume element (RVE) including an epoxy matrix with randomly distributed poly(methyl methacrylate) (PMMA) microcapsules is modeled in DigimatTM software and analyzed in Abaqus®. A new technique is developed to investigate the progressive damage by pre-inserted cohesive elements along all element boundaries of the epoxy matrix, PMMA shell, and capsule-matrix interfaces with the bilinear traction–separation law. Moreover, the impact of interface bonding strength, interface fracture energy, and PMMA microcapsules volume fraction on the load-carrying capacity of the RVEs under uniaxial tension loading was studied. The results indicated that the tensile strength of the self-healing polymer composite increased as the interfacial strength and fracture energy increased from 10 to 60 MPa and 100 to 1000 J/m2, respectively. Furthermore, the higher volume fraction of 5% PMMA microcapsules results in a lower load-carrying capacity of self-healing polymer composite with a strength of 4.9 N. A similar trend of Young’s modulus was observed for microcapsule-loaded epoxy composite compared to the pristine epoxy matrix. The micromechanical model has proper accuracy in predicting the tension behavior of self-healing composite in comparison to experimental results. Finally, two healing strategies are considered for the damaged RVE.
- 3 April 2023
- Published by Taylor & Francis in Mechanics of Advanced Materials and Structures
- Vol. 31 (18) , 4295-4308
A micromechanical damage-healing model for encapsulation-based self-healing polymer composites under tensile loading
In this study, a novel micromechanics-based damage model is proposed for the damage evolution of a two-component microencapsulated-based self-healing polymer composite. In this way, a representative volume element (RVE) including an epoxy matrix with randomly distributed poly(methyl methacrylate) (PMMA) microcapsules is modeled in DigimatTM software and analyzed in Abaqus®. A new technique is developed to investigate the progressive damage by pre-inserted cohesive elements along all element boundaries of the epoxy matrix, PMMA shell, and capsule-matrix interfaces with the bilinear traction–separation law. Moreover, the impact of interface bonding strength, interface fracture energy, and PMMA microcapsules volume fraction on the load-carrying capacity of the RVEs under uniaxial tension loading was studied. The results indicated that the tensile strength of the self-healing polymer composite increased as the interfacial strength and fracture energy increased from 10 to 60 MPa and 100 to 1000 J/m2, respectively. Furthermore, the higher volume fraction of 5% PMMA microcapsules results in a lower load-carrying capacity of self-healing polymer composite with a strength of 4.9 N. A similar trend of Young’s modulus was observed for microcapsule-loaded epoxy composite compared to the pristine epoxy matrix. The micromechanical model has proper accuracy in predicting the tension behavior of self-healing composite in comparison to experimental results. Finally, two healing strategies are considered for the damaged RVE.
- 26 August 2016
- Published by Taylor & Francis in Materials and Manufacturing Processes
- Vol. 32 (12) , 1375-1383
Effects of aluminum and copper cover tube casing on the ECAP process of AM30 magnesium alloy
Aluminum (Al) and copper (Cu) thin tube casings were employed to facilitate the equal channel angular pressing (ECAP) process of wrought AM30 magnesium (Mg) alloy. We covered the Mg rods (diameter, 14 mm) with pure copper (Mg/Cu) and Al-1050 alloy (Mg/Al) sheaths in the form of tubes (thickness, 2.5 mm). We then performed the ECAP processes at 200, 250, and 275°C using the conventional ECAP of AM30 alloy and covered tube casing (CTC) methods with a single pass. We assessed the effect of CTC on ECAP temperature, grain refinement, uniformity of structure, hardness distribution, and strength. The results of Mg/Cu and Mg/Al bimetal sample tests showed that there was a significant decrease in the process temperature when compared with the conventional ECAP of AM30. The sheath resolved the segmented material flow that occurred in a conventional ECAP of material at 250°C, and transformed it to a uniform flow in CTC bimetal samples. Grain sizes of the CTC samples decreased by 20% compared with the conventional ECAP of AM30 samples. Furthermore, grain uniformity, strain distribution homogeneity, tensile yield strength (TYS), and elongation increased. However, we observed a similar trend of deformation twinning in compression test results for the ECAP and CTC methods, and there was no significant variation in material yield asymmetry between the ECAP and CTC samples.
- 26 August 2016
- Published by Taylor & Francis in Materials and Manufacturing Processes
- Vol. 32 (12) , 1375-1383
Effects of aluminum and copper cover tube casing on the ECAP process of AM30 magnesium alloy
Aluminum (Al) and copper (Cu) thin tube casings were employed to facilitate the equal channel angular pressing (ECAP) process of wrought AM30 magnesium (Mg) alloy. We covered the Mg rods (diameter, 14 mm) with pure copper (Mg/Cu) and Al-1050 alloy (Mg/Al) sheaths in the form of tubes (thickness, 2.5 mm). We then performed the ECAP processes at 200, 250, and 275°C using the conventional ECAP of AM30 alloy and covered tube casing (CTC) methods with a single pass. We assessed the effect of CTC on ECAP temperature, grain refinement, uniformity of structure, hardness distribution, and strength. The results of Mg/Cu and Mg/Al bimetal sample tests showed that there was a significant decrease in the process temperature when compared with the conventional ECAP of AM30. The sheath resolved the segmented material flow that occurred in a conventional ECAP of material at 250°C, and transformed it to a uniform flow in CTC bimetal samples. Grain sizes of the CTC samples decreased by 20% compared with the conventional ECAP of AM30 samples. Furthermore, grain uniformity, strain distribution homogeneity, tensile yield strength (TYS), and elongation increased. However, we observed a similar trend of deformation twinning in compression test results for the ECAP and CTC methods, and there was no significant variation in material yield asymmetry between the ECAP and CTC samples.
- 1 January 2014
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 593, 178-184
ECAP effect on the micro-structure and mechanical properties of AM30 magnesium alloy
- 1 January 2014
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 593, 178-184
ECAP effect on the micro-structure and mechanical properties of AM30 magnesium alloy