Luca Troise
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Luca Troise has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Huck
Technical University of Denmark
3 shared publications - James Luke Webb
Center for Macroscopic Quantum States (bigQ), Department of Physics, Technical University of Denmark, 2800 Kongens Lyngby, Denmark
3 shared publications - Jean-François Perrier
University of Copenhagen
2 shared publications Michael Kieschnick
2 shared publicationsUlrik L. Andersen
Technical University of Denmark
2 shared publicationsAdam M. Wojciechowski
Jagiellonian University, Krakow, Poland
1 shared publication
Latest Publications
- Open Access
- 22 June 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (6)
High-speed magnetic-field imaging via N- V ensemble and laser raster scanning
We present a technique based on an ensemble of nitrogen-vacancy (N- V ) centers in diamond capable of imaging magnetic fields with high spatiotemporal resolution and sensitivity. A focused laser beam is raster scanned using an acousto-optic deflector and N- V center fluorescence is read out with a single photodetector, enabling near shot-noise-limited imaging. The method operates in what we term quasi-continuous-wave optically detected magnetic resonance (qCW-ODMR), a regime closely related to pulsed-ODMR schemes used to mitigate power broadening. In this qCW regime, N- V centers experience short optical pump pulses for spin polarization and readout while the microwave field continuously drives the spin transitions. We systematically characterize this regime and show that the spin response is governed by a tunable interplay between coherent evolution and relaxation, determined by the temporal spacing between pump laser pulses. Notably, the technique does not require precise microwave pulse control, thus simplifying experimental implementation. To demonstrate its capabilities, we image time-varying magnetic fields from a microwire with submillisecond temporal resolution. This approach enables flexible spatial sampling and, with our diamond, achieves nT / Hz -level per-pixel sensitivity, making it a promising platform for imaging weak, dynamic magnetic fields in biological and other complex systems.
- 22 June 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (6)
Open AccessHigh-speed magnetic-field imaging via N- V ensemble and laser raster scanning
We present a technique based on an ensemble of nitrogen-vacancy (N- V ) centers in diamond capable of imaging magnetic fields with high spatiotemporal resolution and sensitivity. A focused laser beam is raster scanned using an acousto-optic deflector and N- V center fluorescence is read out with a single photodetector, enabling near shot-noise-limited imaging. The method operates in what we term quasi-continuous-wave optically detected magnetic resonance (qCW-ODMR), a regime closely related to pulsed-ODMR schemes used to mitigate power broadening. In this qCW regime, N- V centers experience short optical pump pulses for spin polarization and readout while the microwave field continuously drives the spin transitions. We systematically characterize this regime and show that the spin response is governed by a tunable interplay between coherent evolution and relaxation, determined by the temporal spacing between pump laser pulses. Notably, the technique does not require precise microwave pulse control, thus simplifying experimental implementation. To demonstrate its capabilities, we image time-varying magnetic fields from a microwire with submillisecond temporal resolution. This approach enables flexible spatial sampling and, with our diamond, achieves nT / Hz -level per-pixel sensitivity, making it a promising platform for imaging weak, dynamic magnetic fields in biological and other complex systems.
- Open Access
Microscopic-scale recording of brain neuronal electrical activity using a diamond quantum sensor
An important tool in the investigation of the early stages of neurodegenerative disease is the study of dissected living tissue from the brain of an animal model. Such investigations allow the physical structure of individual neurons and neural circuits to be probed alongside neuronal electrical activity, disruption of which can shed light on the mechanisms of emergence of disease. Existing techniques for recording activity rely on potentially damaging direct interaction with the sample, either mechanically as point electrical probes or via intense focused laser light combined with highly specific genetic modification and/or potentially toxic fluorescent dyes. In this work, we instead perform passive, microscopic-scale recording of electrical activity using a biocompatible quantum sensor based on colour centres in diamond. We record biomagnetic field induced by ionic currents in mouse corpus callosum axons without direct sample interaction, accurately recovering signals corresponding to action potential propagation while demonstrating in situ pharmacology during biomagnetic recording through tetrodotoxin inhibition of voltage gated sodium channels. Our results open a promising new avenue for the microscopic recording of neuronal signals, offering the prospect of high resolution imaging of electrical circuits in the living mammalian brain.
Open AccessMicroscopic-scale recording of brain neuronal electrical activity using a diamond quantum sensor
An important tool in the investigation of the early stages of neurodegenerative disease is the study of dissected living tissue from the brain of an animal model. Such investigations allow the physical structure of individual neurons and neural circuits to be probed alongside neuronal electrical activity, disruption of which can shed light on the mechanisms of emergence of disease. Existing techniques for recording activity rely on potentially damaging direct interaction with the sample, either mechanically as point electrical probes or via intense focused laser light combined with highly specific genetic modification and/or potentially toxic fluorescent dyes. In this work, we instead perform passive, microscopic-scale recording of electrical activity using a biocompatible quantum sensor based on colour centres in diamond. We record biomagnetic field induced by ionic currents in mouse corpus callosum axons without direct sample interaction, accurately recovering signals corresponding to action potential propagation while demonstrating in situ pharmacology during biomagnetic recording through tetrodotoxin inhibition of voltage gated sodium channels. Our results open a promising new avenue for the microscopic recording of neuronal signals, offering the prospect of high resolution imaging of electrical circuits in the living mammalian brain.
- Open Access
- 28 January 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-11
Detection of biological signals from a live mammalian muscle using an early stage diamond quantum sensor
The ability to perform noninvasive and non-contact measurements of electric signals produced by action potentials is essential in biomedicine. A key method to do this is to remotely sense signals by the magnetic field they induce. Existing methods for magnetic field sensing of mammalian tissue, used in techniques such as magnetoencephalography of the brain, require cryogenically cooled superconducting detectors. These have many disadvantages in terms of high cost, flexibility and limited portability as well as poor spatial and temporal resolution. In this work we demonstrate an alternative technique for detecting magnetic fields generated by the current from action potentials in living tissue using nitrogen vacancy centres in diamond. With 50 pT/ $$\sqrt{\text {Hz}}$$ sensitivity, we show the first measurements of magnetic sensing from mammalian tissue with a diamond sensor using mouse muscle optogenetically activated with blue light. We show these proof of principle measurements can be performed in an ordinary, unshielded lab environment and that the signal can be easily recovered by digital signal processing techniques. Although as yet uncompetitive with probe electrophysiology in terms of sensitivity, we demonstrate the feasibility of sensing action potentials via magnetic field in mammals using a diamond quantum sensor, as a step towards microscopic imaging of electrical activity in a biological sample using nitrogen vacancy centres in diamond.- 28 January 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-11
Open AccessDetection of biological signals from a live mammalian muscle using an early stage diamond quantum sensor
The ability to perform noninvasive and non-contact measurements of electric signals produced by action potentials is essential in biomedicine. A key method to do this is to remotely sense signals by the magnetic field they induce. Existing methods for magnetic field sensing of mammalian tissue, used in techniques such as magnetoencephalography of the brain, require cryogenically cooled superconducting detectors. These have many disadvantages in terms of high cost, flexibility and limited portability as well as poor spatial and temporal resolution. In this work we demonstrate an alternative technique for detecting magnetic fields generated by the current from action potentials in living tissue using nitrogen vacancy centres in diamond. With 50 pT/ $$\sqrt{\text {Hz}}$$ sensitivity, we show the first measurements of magnetic sensing from mammalian tissue with a diamond sensor using mouse muscle optogenetically activated with blue light. We show these proof of principle measurements can be performed in an ordinary, unshielded lab environment and that the signal can be easily recovered by digital signal processing techniques. Although as yet uncompetitive with probe electrophysiology in terms of sensitivity, we demonstrate the feasibility of sensing action potentials via magnetic field in mammals using a diamond quantum sensor, as a step towards microscopic imaging of electrical activity in a biological sample using nitrogen vacancy centres in diamond. - Open Access
- 10 June 2019
- Published by AIP Publishing in Applied Physics Letters
- Vol. 114 (23) , 231103
Nanotesla sensitivity magnetic field sensing using a compact diamond nitrogen-vacancy magnetometer
Solid state sensors utilizing diamond nitrogen-vacancy (NV) centers are a promising sensing platform that can provide high sensitivity and spatial resolution at high precision. Such sensors have been realized in bulky laboratory-based forms; however, practical applications demand a miniaturized, portable sensor that can function in a wide range of environmental conditions. Here, we demonstrate such a diamond NV magnetic field sensor. The sensor head fits inside a 3D-printed box and exhibits sub-10 nT/ sensitivity over a 125 Hz bandwidth. We achieve efficient fluorescence collection using an optical filter and diode in contact with the diamond, which is cut at the Brewster angle to maximize the coupling of 532 nm pump light. We discuss the potential of this flexible approach to achieve sub-nT/ shot noise limited sensitivity suitable for detection of a wide range of low-level magnetic fields, particularly those from electrical power systems and from biological sources.- 10 June 2019
- Published by AIP Publishing in Applied Physics Letters
- Vol. 114 (23) , 231103
Open AccessNanotesla sensitivity magnetic field sensing using a compact diamond nitrogen-vacancy magnetometer
Solid state sensors utilizing diamond nitrogen-vacancy (NV) centers are a promising sensing platform that can provide high sensitivity and spatial resolution at high precision. Such sensors have been realized in bulky laboratory-based forms; however, practical applications demand a miniaturized, portable sensor that can function in a wide range of environmental conditions. Here, we demonstrate such a diamond NV magnetic field sensor. The sensor head fits inside a 3D-printed box and exhibits sub-10 nT/ sensitivity over a 125 Hz bandwidth. We achieve efficient fluorescence collection using an optical filter and diode in contact with the diamond, which is cut at the Brewster angle to maximize the coupling of 532 nm pump light. We discuss the potential of this flexible approach to achieve sub-nT/ shot noise limited sensitivity suitable for detection of a wide range of low-level magnetic fields, particularly those from electrical power systems and from biological sources.