    Feasibility of 3D gel dosimetry for CBCT-based isocenter verification on ELEKTA systems

    by Oskar Madetko, Piotr Maras, Bartłomiej Jasiak, Marek Kozicki

    This study presents the first results on the feasibility of using 3D polymer gel dosimetry for CBCT-based verification of mechanical, imaging, and radiation isocenters on Elekta systems.

  • Open Access

    Characterisation of Fricke-xylenol orange-Pluronic gel dosimeters for end-to-end three-dimensional radiotherapy dosimetric quality assurance

    by Ioanna Grammatikou, Michal Piotrowski, Panagiotis Papagiannis, Anastasia Stergioula, Piotr Maras, Marek Kozicki, Evaggelos Pantelis

    Objective. Fricke–xylenol orange (XO)–Pluronic F-127 (FXP) gels have demonstrated favourable dosimetric properties, but their investigation has hitherto been limited to small sample volumes. This study characterised large-volume FXP gel dosimeters combined with optical computed tomography (OCT) readout for three-dimensional 6MV radiotherapy dosimetry measurements. Approach. An FXP gel formulation proposed in the literature (25% w/w Pluronic F-127, 0.165mM XO, 0.5mM FAS, 50mM H₂SO₄) and two reduced XO formulations (0.08mM and 0.04mM) were investigated using OCT readout at 589nm and 633nm. The effects of XO concentration and scanning wavelength on dose sensitivity, dose resolution, and [XO–Fe]³⁺ ion diffusion were evaluated. Main results. All FXP formulations exhibited linear dose–response behaviour over the studied dose range of 0.2–4.15Gy. OCT readout at 589nm provided higher dose sensitivity but was associated with increased optical attenuation and ring artefacts. Reducing the XO concentration to 0.08mM preserved dose sensitivity, whereas further reduction to 0.04mM resulted in reduced sensitivity without a noticeable impact on imaging artefacts. OCT readout at 633nm mitigated imaging artefacts at the expense of dose sensitivity, while achieving dose resolutions below 5% at doses above 1.5Gy (95% confidence level). The diffusion of [XO–Fe]³⁺ ions was found to decrease with increasing XO concentration and to be anisotropic with respect to gravity, supporting a post-irradiation readout time window of 60 to 120min to limit spatial blurring. An optimised FXP–OCT configuration employing 0.08mM XO, a 633nm scanning wavelength, and readout at 60min post irradiation, was applied to an end-to-end (E2E) radiotherapy quality assurance protocol. Results exhibited good agreement with treatment planning system calculations for an intracranial stereotactic radiotherapy plan, with a 3D global gamma index passing rate of 96% (3%/2mm criteria). Significance. These findings support the feasibility of large-volume FXP gel dosimetry for E2E dosimetric quality assurance in complex radiotherapy applications.

  • Open Access

    Radiation-Sensitive Nano-, Micro-, and Macro-Gels and Polymer Capsules for Use in Radiotherapy Dosimetry

    by Michał Piotrowski, Aleksandra Pawlaczyk, Małgorzata I. Szynkowska-Jóźwik, Piotr Maras, Marek Kozicki

    This work introduces an original approach to the manufacturing of ionizing radiation-sensitive systems for radiotherapy applications—dosimetry. They are based on the Fricke dosimetric solution and the formation of macro-gels and capsules, and nano- and micro-gels. The reaction of ionic polymers, such as sodium alginate, with Fe and Ca metal ions is employed. Critical polymer concentration (c*) is taken as the criterion. Reaction of ionic polymers with metal ions leads to products related to c*. Well below c*, nano- and micro-gels may form. Above c*, macro-gels and capsules can be prepared. Nano- and micro-gels containing Fe in the composition can be used for infusion of a physical gel matrix to prepare 2D or 3D dosimeters. In turn, macro-gels can be formed with Fe ions crosslinking polymer chains to obtain radiation-sensitive hydrogels, so-called from wall-to-wall, serving as 3D dosimeters. The encapsulation process can lead to capsules with Fe ions serving as 1D dosimeters. This work presents the concept of manufacturing various gel structures, their main features and manufacturing challenges. It proposes new directions of research towards novel dosimeters.

  • Open Access

    Deformable Fricke-XO-Gelatin Radiochromic Dosimeter of Ionizing Radiation and Its Applications in Quality Assurance Tests for Radiation Therapy

    by Michał Piotrowski, Piotr Maras, Zbigniew Stempień, Radosław Wach, Marek Kozicki

    This work presents a Fricke radiochromic gel dosimeter with xylenol orange (XO) and a gelatin matrix modified with sorbitol. The dosimeter, combined with 2D scanning using a flatbed scanner and data processing using dedicated software packages, creates a radiotherapy dosimetry measurement system. The dosimeter reacts to ionizing radiation by changing color as a result of the formation of complexes of Fe3+ and XO molecules. It was characterized in terms of thermal and chemical stability and mechanical properties. The presence of sorbitol improved the mechanical and thermal properties of the dosimeter. The dosimeter maintains chemical stability, enabling its use in dosimetric applications, for at least six weeks. The dose–response characteristics of the dosimeter are discussed and indicate a dynamic dose–response of the dosimeter (up to saturation) of about 20 Gy and a linear dose–response of about 12.5 Gy. The following applications of the dosimeter are discussed: (i) as a 2D dosimeter in a plastic container for performing a coincidence test of radiation and mechanical isocenters of a medical accelerator, and (ii) for in vivo dosimetry as a 2D dosimeter alone and simultaneously as a bolus and a 2D dosimeter. Research has shown that the dosimeter has promise in many applications.


  • Open Access

    Use of a Flexible Two-Dimensional Textile Dosimeter with a Kilogray Dose Range to Measure the Dose Distribution for a 60Co Source

    by Marek Kozicki, Radosław Wach, Elżbieta Sąsiadek-Andrzejczak, Piotr Maras

    The two-dimensional (2D) measurement of radiation dose distribution on non-planar surfaces requires the use of a flexible dosimeter. This work concerns the use of a unique cotton textile-based dosimeter to characterize the dose distribution of a 60Co source used in the research and sterilization of products. Alternatively, for high-dose-rate experiments, an electron beam accelerator has been used. The dosimeter was prepared by the padding-squeezing-drying of a cotton textile made of cellulose, where a 10% solution of nitrotetrazolium blue chloride (NBT) was used for the padding process. NBT served as a radiation-sensitive compound, which transformed into a purple-brown NBT formazan upon exposure to ionizing radiation. The NBT dosimeter is scanned after irradiation using a flatbed scanner, and the data is processed using dedicated software packages, which together constitute a 2D dose distribution measurement system. The green channel of the RGB color model contributes the most to the color change of the dosimeter. The calibration relation obtained for the green channel showed that the dosimeter responds to doses of 0.8–45 kGy. Conversions of the green channel signal were performed using the calibration relation to analyze the 2D dose at a large distance and close to a 60Co source shielded by a solid metal and a cylindrical metal structure with holes. Additionally, the dose distribution was assessed using a dosimeter placed on metal implant models undergoing radiation serialization. This work demonstrates the potential of such a dosimeter for characterizing high-dose-rate 60Co sources and measuring the dose distribution on non-planar surfaces.

  • Open Access

    Storage Conditions of Textile Dosimeters for 2D UV Dose Measurements

    by Elżbieta Sąsiadek-Andrzejczak, Piotr Maras, Marek Kozicki

    This paper presents the optimization of storage conditions for textile dosimeters for ultraviolet radiation measurements, which are based on cotton-woven fabric and nitroblue tetrazolium chloride (NBT) as a radiation-sensitive compound. The results of changes in light reflectance and color coordinates depending on the storage time of the samples over six months from their manufacturing under various storage conditions are presented. The results obtained for cotton—NBT dosimeters, unirradiated and irradiated with a UVC dose of 100 mJ/cm2, stored under the following conditions were compared: (i) at room temperature (23–25 °C, humidity 40–60%), without access to light; (ii) in a fridge (3–5 °C, humidity 70–90%), without access to light; (iii) in a freezer (−17 to −20 °C, humidity 80–90%), without access to light; and (iv) at room temperature (23–25 °C, humidity 40–60%), with access to light. Additionally, it was presented that the cotton–NBT dosimeters were suitable for 2D measurement of UV radiation doses after a period of eight months. The obtained results complement previous studies on cotton–NBT textile dosimeters and are crucial for determining the conditions of use and the expiry date of such systems.


  • Open Access

    Flexible and Ecological Cotton-Based Dosimeter for 2D UV Surface Dose Distribution Measurements

    by Elżbieta Sąsiadek-Andrzejczak, Piotr Maras, Marek Kozicki

    This work presents a 2D radiochromic dosimeter for ultraviolet (UV) radiation measurements, based on cotton fabric volume-modified with nitroblue tetrazolium chloride (NBT) as a radiation-sensitive compound. The developed dosimeter is flexible, which allows it to adapt to various shapes and show a color change from yellowish to purple-brown during irradiation. The intensity of the color change depends on the type of UV radiation and is the highest for UVC (253.7 nm). It has been shown that the developed dosimeters (i) can be used for UVC radiation dose measurements in the range of up to 10 J/cm2; (ii) can be measured in 2D using a flatbed scanner; and (iii) can have the obtained images after scanning be filtered with a medium filter to improve their quality by reducing noise from the fabric structure. The developed cotton–NBT dosimeters can measure UVC-absorbed radiation doses on objects of various shapes, and when combined with a dedicated computer software package and a data processing method, they form a comprehensive system for measuring dose distributions for objects with complex shapes. The developed system can also serve as a comprehensive method for assessing the quality and control of UV radiation sources used in various industrial processes.


  • Open Access

    An Optical Reusable 2D Radiochromic Gel-Based System for Ionising Radiation Measurements in Radiotherapy

    by Marek Kozicki, Piotr Maras

    This work describes the development of a reusable 2D detector based on radiochromic reaction for radiotherapy dosimetric measurements. It consists of a radiochromic gel dosimeter in a cuboidal plastic container, scanning with a flatbed scanner, and data processing using a dedicated software package. This tool is assessed using the example of the application of the coincidence test of radiation and mechanical isocenters for a medical accelerator. The following were examined: scanning repeatability and image homogeneity, the impact of image processing on data processing in coincidence tests, and irradiation conditions—monitor units per radiation beam and irradiation field are selected. Optimal conditions for carrying out the test are chosen: (i) the multi-leaf collimator gap should preferably be 5 mm for 2D star shot irradiation, (ii) it is recommended to apply ≥2500–≤5000 MU per beam to obtain a strong signal enabling easy data processing, (iii) Mean filter can be applied to the images to improve calculations. An approach to dosimeter reuse with the goal of reducing costs is presented; the number of reuses is related to the MUs per beam, which, in this study, is about 5–57 for 30,000–2500 MU per beam (four fields). The proposed reusable system was successfully applied to the coincidence tests, confirming its suitability as a new potential quality assurance tool in radiotherapy.


  • Open Access

    On the Use of the Fricke-Pluronic F-127 Gel Dosimeter for Radiation Isocenter Testing of a Medical Linear Accelerator

    by Michał Piotrowski, Piotr Maras, Marek Kozicki

    This work presents a Fricke-XO-Pluronic F-127 2D radiochromic dosimeter with a flat-bed scanner for 2D reading and a dedicated data processing software package as a tool for performing coincidence testing of the radiation and mechanical isocenter of a medical accelerator. The optimal irradiation parameters were determined as follows: monitor units per beam and multi-leaf collimator gap, which are ≤750–≤2500 MU and 2–5 mm, respectively, for a cuboidal container with dimensions of 12 × 12 × 0.3 cm3. Despite the diffusion of Fe3+ ions occurring during irradiation, 2D reading can be performed at least 3 h after irradiation, without affecting the calculation performance of the coincidence test. The test was successfully performed for various irradiation settings. Overall, the Fricke-XO-Pluronic F-127 dosimeter has proven to be a potential tool for the coincidence testing of medical accelerators.


  • Open Access

    3D Polymer Gel Dosimeters with iCBCT 3D Reading and polyGeVero-CT Software Package for Quality Assurance in Radiotherapy

    by Marek Kozicki, Piotr Maras, Malwina Jaszczak-Kuligowska

    Dynamically evolving radiotherapy instruments require advancements in compatible 3D dosimetry systems. This paper reports on such tools for the coincidence test of the mechanical and radiation isocenter for a medical accelerator as part of the quality assurance in routine radiotherapy practice. Three-dimensional polymer gel dosimeters were used in combination with 3D reading by iterative cone beam computed tomography and 3D data processing using the polyGeVero-CT software package. Different polymer gel dosimeters were used with the following acronyms: VIP, PAGAT, MAGIC, and NIPAM. The same scheme was used for each dosimeter: (i) irradiation sensitivity test for the iterative cone beam computed tomography reading to determine the appropriate monitor unit for irradiation, and (ii) verification of the chosen irradiation conditions by a star-shot 2D irradiation of each 3D dosimeter in the direction of performing the test. This work concludes with the optimum monitor unit per beam for each selected 3D dosimeter, delivers schemes for quick and easy determination of the radiation isocenter and performing the coincidence test.