Zhizheng Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhizheng Hu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Lixin Zhang
College of Mechanical and Electrical Engineering, Shihezi University, Shihezi 832000, China
2 shared publications - Wendong Wang
College of Mechanical and Electrical Engineering, Shihezi University, Shihezi 832003, China
2 shared publications - Xiao Ma
College of Mechanical and Electrical Engineering, Shihezi University, Shihezi 832003, China
2 shared publications - Chanchan Du
College of Mechanical and Electrical Engineering, Shihezi University, Shihezi 832003, China
1 shared publication - Haifeng Zeng
College of Mechanical and Electrical Engineering, Shihezi University, Shihezi 832000, China
1 shared publication - He Li
College of Mechanical and Electrical Engineering, Shihezi University, Shihezi 832003, China
1 shared publication
Latest Publications
- Open Access
Application of the Modified Fuzzy-PID-Smith Predictive Compensation Algorithm in a pH-Controlled Liquid Fertilizer System
An appropriate pH value of liquid fertilizer can enable crops to better absorb nutrients from fertilizers. However, the mixed liquid fertilizer with high concentration of liquid fertilizer and irrigation water has a high pH value, which affects the absorption of nutrients by crops. Therefore, the precise regulation of liquid fertilizer pH value is an important link to realize the integration of water and fertilizer in modern agriculture. Due to pipeline transportation and diffusion of the regulating liquid and liquid fertilizer, the pH value control system has the characteristics of time-varying, non-linear and time-delayed models, and it is difficult for ordinary controllers to accurately control the pH value of liquid fertilizer. Therefore, modern agriculture urgently needs a controller that can adapt to non-linear and uncertain systems. According to the characteristics of the pH regulation process of liquid fertilizer, this study proposes and designs a modified fuzzy-PID-Smith predictive compensation algorithm, which adds the fuzzy-PID algorithm to the predictor of the conventional Smith algorithm to compensate for the error between the actual and theoretical models in order to reduce the decline of control quality caused by the model mismatch to the control system. To verify the practicability and robustness of the algorithm in practical applications, a liquid fertilizer pH value control system with STM32F103ZET6 as the control core was developed. The pH control system with fuzzy-PID and Smith algorithm as controller was used as the control group. The model was simulated and tested under two conditions of exact matching and imprecise matching, and performance tests were carried out under different output flow rates. The results showed that the maximum overshoot of the modified fuzzy-PID-Smith predictive compensation algorithm was significantly less than that of the other two algorithms at different output flow rates, with an average of 0.23%. The average steady-state time of adjusting the pH value of liquid fertilizer from 7.3 to 6.8 was 72 s, which was superior to the 145 s and 3.2% of fuzzy-PID and 130 s and 1.4% of the Smith controller.
Open AccessApplication of the Modified Fuzzy-PID-Smith Predictive Compensation Algorithm in a pH-Controlled Liquid Fertilizer System
An appropriate pH value of liquid fertilizer can enable crops to better absorb nutrients from fertilizers. However, the mixed liquid fertilizer with high concentration of liquid fertilizer and irrigation water has a high pH value, which affects the absorption of nutrients by crops. Therefore, the precise regulation of liquid fertilizer pH value is an important link to realize the integration of water and fertilizer in modern agriculture. Due to pipeline transportation and diffusion of the regulating liquid and liquid fertilizer, the pH value control system has the characteristics of time-varying, non-linear and time-delayed models, and it is difficult for ordinary controllers to accurately control the pH value of liquid fertilizer. Therefore, modern agriculture urgently needs a controller that can adapt to non-linear and uncertain systems. According to the characteristics of the pH regulation process of liquid fertilizer, this study proposes and designs a modified fuzzy-PID-Smith predictive compensation algorithm, which adds the fuzzy-PID algorithm to the predictor of the conventional Smith algorithm to compensate for the error between the actual and theoretical models in order to reduce the decline of control quality caused by the model mismatch to the control system. To verify the practicability and robustness of the algorithm in practical applications, a liquid fertilizer pH value control system with STM32F103ZET6 as the control core was developed. The pH control system with fuzzy-PID and Smith algorithm as controller was used as the control group. The model was simulated and tested under two conditions of exact matching and imprecise matching, and performance tests were carried out under different output flow rates. The results showed that the maximum overshoot of the modified fuzzy-PID-Smith predictive compensation algorithm was significantly less than that of the other two algorithms at different output flow rates, with an average of 0.23%. The average steady-state time of adjusting the pH value of liquid fertilizer from 7.3 to 6.8 was 72 s, which was superior to the 145 s and 3.2% of fuzzy-PID and 130 s and 1.4% of the Smith controller.
- Open Access
Simulation and Experiment of Gas-Solid Flow in a Safflower Sorting Device Based on the CFD-DEM Coupling Method
To study the movement characteristics and separation mechanism of safflower petals and their impurities under the action of airflow and lower the impurity rate in the cleaning operation process, integration of computational fluid dynamics (CFD) and discrete element method (DEM) codes was performed to study the motion and sorting behavior of impurity particles and safflower petals under different airflow inclination angles, dust removal angles and inlet airflow velocities by establishing a true particle model. In this model, the discrete particle phase was applied by the DEM software, and the continuum gas phase was described by the ANSYS Fluent software. The Box-Behnken experimental design with three factors and three levels was performed, and parameters such as inlet airflow velocity, airflow inclined angle, and dust remover angle were selected as independent variables that would influence the cleaning impurity rate and the cleaning loss rate. A mathematical model was established, and then the effects of various parameters and their interactions were analyzed. The test results show that the cleaning effect is best when the inlet airflow velocity is 7 m/s, the airflow inclined angle is 0°, and the dust remover angle is 25°. Confirmatory tests showed that the average cleaning impurity rate and cleaning loss rate were 0.69% and 2.75%, respectively, which dropped significantly compared with those from previous optimization. An experimental device was designed and set up; the experimental results were consistent with the simulation results, indicating that studying the physical behavior of safflower petals-impurity separation in the airflow field by using the DEM-CFD coupling method is reliable. This result provides a basis for follow-up studies of separation and cleaning devices for lightweight materials such as safflower petals.
Open AccessSimulation and Experiment of Gas-Solid Flow in a Safflower Sorting Device Based on the CFD-DEM Coupling Method
To study the movement characteristics and separation mechanism of safflower petals and their impurities under the action of airflow and lower the impurity rate in the cleaning operation process, integration of computational fluid dynamics (CFD) and discrete element method (DEM) codes was performed to study the motion and sorting behavior of impurity particles and safflower petals under different airflow inclination angles, dust removal angles and inlet airflow velocities by establishing a true particle model. In this model, the discrete particle phase was applied by the DEM software, and the continuum gas phase was described by the ANSYS Fluent software. The Box-Behnken experimental design with three factors and three levels was performed, and parameters such as inlet airflow velocity, airflow inclined angle, and dust remover angle were selected as independent variables that would influence the cleaning impurity rate and the cleaning loss rate. A mathematical model was established, and then the effects of various parameters and their interactions were analyzed. The test results show that the cleaning effect is best when the inlet airflow velocity is 7 m/s, the airflow inclined angle is 0°, and the dust remover angle is 25°. Confirmatory tests showed that the average cleaning impurity rate and cleaning loss rate were 0.69% and 2.75%, respectively, which dropped significantly compared with those from previous optimization. An experimental device was designed and set up; the experimental results were consistent with the simulation results, indicating that studying the physical behavior of safflower petals-impurity separation in the airflow field by using the DEM-CFD coupling method is reliable. This result provides a basis for follow-up studies of separation and cleaning devices for lightweight materials such as safflower petals.
- Open Access
Experimental and Numerical Simulation Study of Pressure Pulsations during Hose Pump Operation
An adventitious flow field has a great impact on the operational reliability of pumps; therefore, it is important to study pump flow characteristics to reduce the noise, vibration, and cavitation performance of pumps. To study the pressure fluctuation characteristics of the hose pump, a three-dimensional two-way fluid structure coupling model of the hose pump was established. The transient structural module, fluid flow (fluent) module, and system coupling module of ANSYS Workbench 19.0 were used to simulate the unsteady multiple working conditions of the hose pump. The accuracy and reliability of the calculation results from the fluid solid coupling simulation were verified via experimentation. The results show that the roller pass frequency is the main frequency of the pressure fluctuation at the outlet of the hose pump. When the plane of the deformation recovery area is small, the pressure pulsation amplitude is large, and the outlet pressure and speed are large. Due to the irregular backflow of the fluid, stall zones of different sizes form, the outlet pressure is closer to a sinusoid when there is no pressure. The higher the rotating speed is, the faster the pressure roller leaving the hose, the higher the pressure pulsation, and the larger the stall zone. Therefore, the best way to reduce the pressure pulsation in the pump is to optimize the geometry of the pressure roller and change the outlet angle of the hose.
Open AccessExperimental and Numerical Simulation Study of Pressure Pulsations during Hose Pump Operation
An adventitious flow field has a great impact on the operational reliability of pumps; therefore, it is important to study pump flow characteristics to reduce the noise, vibration, and cavitation performance of pumps. To study the pressure fluctuation characteristics of the hose pump, a three-dimensional two-way fluid structure coupling model of the hose pump was established. The transient structural module, fluid flow (fluent) module, and system coupling module of ANSYS Workbench 19.0 were used to simulate the unsteady multiple working conditions of the hose pump. The accuracy and reliability of the calculation results from the fluid solid coupling simulation were verified via experimentation. The results show that the roller pass frequency is the main frequency of the pressure fluctuation at the outlet of the hose pump. When the plane of the deformation recovery area is small, the pressure pulsation amplitude is large, and the outlet pressure and speed are large. Due to the irregular backflow of the fluid, stall zones of different sizes form, the outlet pressure is closer to a sinusoid when there is no pressure. The higher the rotating speed is, the faster the pressure roller leaving the hose, the higher the pressure pulsation, and the larger the stall zone. Therefore, the best way to reduce the pressure pulsation in the pump is to optimize the geometry of the pressure roller and change the outlet angle of the hose.