Qingfei Luo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Qingfei Luo has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Xiaohong Joe Zhou
Center for MR Research and Departments of Radiology, Neurosurgery, and Bioengineering, University of Illinois at Chicago, Chicago, Illinois, USA
11 shared publications - Guangyu Dan
Center for Magnetic Resonance Research University of Illinois at Chicago Chicago Illinois USA
7 shared publications - Kaibao Sun
Center for Magnetic Resonance Research University of Illinois at Chicago Chicago Illinois USA
7 shared publications - Zheng Zhong
Center for Magnetic Resonance Research University of Illinois at Chicago Chicago Illinois USA
5 shared publications - Meryem Muge Karaman
Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, United States of America
4 shared publications - Enamul Hoque Bhuiyan
Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL, USA
3 shared publications
Latest Publications
- Open Access
Deep Learning for Gradient and BCG Artifacts Removal in EEG During Simultaneous fMRI
Simultaneous EEG-fMRI recording combines high temporal and spatial resolution for tracking neural activity. However, its usefulness is greatly limited by artifacts from magnetic resonance (MR), especially gradient artifacts (GA) and ballistocardiogram (BCG) artifacts, which interfere with the EEG signal. To address this issue, we used a denoising autoencoder (DAR), a deep learning framework designed to reduce MR-related artifacts in EEG recordings. Using paired data that includes both artifact-contaminated and MR-corrected EEG from the CWL EEG-fMRI dataset, DAR uses a 1D convolutional autoencoder to learn a direct mapping from noisy to clear signal segments. Compared to traditional artifact removal methods like principal component analysis (PCA), independent component analysis (ICA), average artifact subtraction (AAS), and wavelet thresholding, DAR shows better performance. It achieves a root-mean-squared error (RMSE) of 0.0218 $\pm$ 0.0152, a structural similarity index (SSIM) of 0.8885 $\pm$ 0.0913, and a signal-to-noise ratio (SNR) gain of 14.63 dB. Statistical analysis with paired t-tests confirms that these improvements are significant (p1.2). A leave-one-subject-out (LOSO) cross-validation protocol shows that the model generalizes well, yielding an average RMSE of 0.0635 $\pm$ 0.0110 and an SSIM of 0.6658 $\pm$ 0.0880 across unseen subjects. Additionally, saliency-based visualizations demonstrate that DAR highlights areas with dense artifacts, which makes its decisions easier to interpret. Overall, these results position DAR as a potential and understandable solution for real-time EEG artifact removal in simultaneous EEG-fMRI applications.Open AccessDeep Learning for Gradient and BCG Artifacts Removal in EEG During Simultaneous fMRI
Simultaneous EEG-fMRI recording combines high temporal and spatial resolution for tracking neural activity. However, its usefulness is greatly limited by artifacts from magnetic resonance (MR), especially gradient artifacts (GA) and ballistocardiogram (BCG) artifacts, which interfere with the EEG signal. To address this issue, we used a denoising autoencoder (DAR), a deep learning framework designed to reduce MR-related artifacts in EEG recordings. Using paired data that includes both artifact-contaminated and MR-corrected EEG from the CWL EEG-fMRI dataset, DAR uses a 1D convolutional autoencoder to learn a direct mapping from noisy to clear signal segments. Compared to traditional artifact removal methods like principal component analysis (PCA), independent component analysis (ICA), average artifact subtraction (AAS), and wavelet thresholding, DAR shows better performance. It achieves a root-mean-squared error (RMSE) of 0.0218 $\pm$ 0.0152, a structural similarity index (SSIM) of 0.8885 $\pm$ 0.0913, and a signal-to-noise ratio (SNR) gain of 14.63 dB. Statistical analysis with paired t-tests confirms that these improvements are significant (p1.2). A leave-one-subject-out (LOSO) cross-validation protocol shows that the model generalizes well, yielding an average RMSE of 0.0635 $\pm$ 0.0110 and an SSIM of 0.6658 $\pm$ 0.0880 across unseen subjects. Additionally, saliency-based visualizations demonstrate that DAR highlights areas with dense artifacts, which makes its decisions easier to interpret. Overall, these results position DAR as a potential and understandable solution for real-time EEG artifact removal in simultaneous EEG-fMRI applications. - Open Access
- 16 June 2025
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 124, 102578
Classification of glioma grade and Ki-67 level prediction in MRI data: A SHAP-driven interpretation
- 16 June 2025
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 124, 102578
Open AccessClassification of glioma grade and Ki-67 level prediction in MRI data: A SHAP-driven interpretation
- Open Access
Image Processing in the Acute to Chronic Pain Signatures (A2CPS) Project
The Acute to Chronic Pain Signatures (A2CPS) project is a large-scale, multi-site initiative aimed at identifying biomarkers and biosignatures that predict the transition from acute to chronic pain. The project is collecting multimodal, longitudinal data from over 2,500 individuals at risk for developing chronic pain after surgery. Here we describe the neuroimaging component of A2CPS, including the acquisition protocols, processing pipelines, and contents of the initial data release. The imaging protocol includes structural, diffusion, resting-state and task-based functional magnetic resonance imaging (MRI) data. Data are collected across multiple clinical sites using different scanner manufacturers, with attention to protocol harmonization and quality control. The processing pipeline integrates several established neuroimaging tools to extract potential biomarkers, including measures of brain structure, connectivity, and pain-related neural signatures. The first data release includes pre-surgical imaging data for 595 participants, with high quality ratings across modalities (98.7% of sMRI, 99.8% of dMRI, and 94.6% of fMRI images were rated as acceptable or better). Initial analyses demonstrate expected relationships between brain-derived measures and clinical variables, such as associations between brain age and psychological factors. This dataset represents a valuable resource for both pain research and neuroimaging methods development, with future releases planned to include additional participants and expanded analysis pipelines and processed data derivatives.
Open AccessImage Processing in the Acute to Chronic Pain Signatures (A2CPS) Project
The Acute to Chronic Pain Signatures (A2CPS) project is a large-scale, multi-site initiative aimed at identifying biomarkers and biosignatures that predict the transition from acute to chronic pain. The project is collecting multimodal, longitudinal data from over 2,500 individuals at risk for developing chronic pain after surgery. Here we describe the neuroimaging component of A2CPS, including the acquisition protocols, processing pipelines, and contents of the initial data release. The imaging protocol includes structural, diffusion, resting-state and task-based functional magnetic resonance imaging (MRI) data. Data are collected across multiple clinical sites using different scanner manufacturers, with attention to protocol harmonization and quality control. The processing pipeline integrates several established neuroimaging tools to extract potential biomarkers, including measures of brain structure, connectivity, and pain-related neural signatures. The first data release includes pre-surgical imaging data for 595 participants, with high quality ratings across modalities (98.7% of sMRI, 99.8% of dMRI, and 94.6% of fMRI images were rated as acceptable or better). Initial analyses demonstrate expected relationships between brain-derived measures and clinical variables, such as associations between brain age and psychological factors. This dataset represents a valuable resource for both pain research and neuroimaging methods development, with future releases planned to include additional participants and expanded analysis pipelines and processed data derivatives.
- Open Access
- 18 June 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (5) , 1952-1964
Fast 3D fMRI acquisition with high spatial resolutions over a reduced FOV
Purpose: To develop and demonstrate a fast 3D fMRI acquisition technique with high spatial resolution over a reduced FOV, named k‐t 3D reduced FOV imaging (3D‐rFOVI).Methods: Based on 3D gradient‐echo EPI, k‐t 3D‐rFOVI used a 2D RF pulse to reduce the FOV in the in‐plane phase‐encoding direction, boosting spatial resolution without increasing echo train length. For image acceleration, full sampling was applied in the central k‐space region along the through‐slab direction (kz) for all time frames, while randomized undersampling was used in outer kz regions at different time frames. Images were acquired at 3T and reconstructed using a method based on partial separability. fMRI detection sensitivity of k‐t 3D‐rFOVI was quantitively analyzed with simulation data. Human visual fMRI experiments were performed to evaluate k‐t 3D‐rFOVI and compare it with a commercial multiband EPI sequence.Results: The simulation data showed that k‐t 3D‐rFOVI can detect 100% of fMRI activations with an acceleration factor (R) of 2 and ˜80% with R = 6. In the human fMRI data acquired with 1.5‐mm spatial resolution and 800‐ms volume TR (TRvol), k‐t 3D‐rFOVI with R = 4 detected 46% more activated voxels in the visual cortex than the multiband EPI. Additional fMRI experiments showed that k‐t 3D‐rFOVI can achieve TRvol of 480 ms with R = 6, while reliably detecting visual activation.Conclusions: k‐t 3D‐rFOVI can simultaneously achieve a high spatial resolution (1.5‐mm isotropically) and short TRvol (480‐ms) at 3T. It offers a robust acquisition technique for fast fMRI studies over a focused brain volume.
- 18 June 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (5) , 1952-1964
Open AccessFast 3D fMRI acquisition with high spatial resolutions over a reduced FOV
Purpose: To develop and demonstrate a fast 3D fMRI acquisition technique with high spatial resolution over a reduced FOV, named k‐t 3D reduced FOV imaging (3D‐rFOVI).Methods: Based on 3D gradient‐echo EPI, k‐t 3D‐rFOVI used a 2D RF pulse to reduce the FOV in the in‐plane phase‐encoding direction, boosting spatial resolution without increasing echo train length. For image acceleration, full sampling was applied in the central k‐space region along the through‐slab direction (kz) for all time frames, while randomized undersampling was used in outer kz regions at different time frames. Images were acquired at 3T and reconstructed using a method based on partial separability. fMRI detection sensitivity of k‐t 3D‐rFOVI was quantitively analyzed with simulation data. Human visual fMRI experiments were performed to evaluate k‐t 3D‐rFOVI and compare it with a commercial multiband EPI sequence.Results: The simulation data showed that k‐t 3D‐rFOVI can detect 100% of fMRI activations with an acceleration factor (R) of 2 and ˜80% with R = 6. In the human fMRI data acquired with 1.5‐mm spatial resolution and 800‐ms volume TR (TRvol), k‐t 3D‐rFOVI with R = 4 detected 46% more activated voxels in the visual cortex than the multiband EPI. Additional fMRI experiments showed that k‐t 3D‐rFOVI can achieve TRvol of 480 ms with R = 6, while reliably detecting visual activation.Conclusions: k‐t 3D‐rFOVI can simultaneously achieve a high spatial resolution (1.5‐mm isotropically) and short TRvol (480‐ms) at 3T. It offers a robust acquisition technique for fast fMRI studies over a focused brain volume.
- Open Access
- 4 September 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (6) , 2375-2387
Three‐dimensional echo‐shifted EPI with simultaneous blip‐up and blip‐down acquisitions for correcting geometric distortion
Purpose: EPI with blip-up/down acquisition (BUDA) can provide high-quality images with minimal distortions by using two readout trains with opposing phase-encoding gradients. Because of the need for two separate acquisitions, BUDA doubles the scan time and degrades the temporal resolution when compared to single-shot EPI, presenting a major challenge for many applications, particularly fMRI. This study aims at overcoming this challenge by developing an echo-shifted EPI BUDA (esEPI-BUDA) technique to acquire both blip-up and blip-down datasets in a single shot.Methods: A 3D esEPI-BUDA pulse sequence was designed by using an echo-shifting strategy to produce two EPI readout trains. These readout trains produced a pair of k-space datasets whose k-space trajectories were interleaved with opposite phase-encoding gradient directions. The two k-space datasets were separately reconstructed using a 3D SENSE algorithm, from which time-resolved B0-field maps were derived using TOPUP in FSL and then input into a forward model of joint parallel imaging reconstruction to correct for geometric distortion. In addition, Hankel structured low-rank constraint was incorporated into the reconstruction framework to improve image quality by mitigating the phase errors between the two interleaved k-space datasets.Results: The 3D esEPI-BUDA technique was demonstrated in a phantom and an fMRI study on healthy human subjects. Geometric distortions were effectively corrected in both phantom and human brain images. In the fMRI study, the visual activation volumes and their BOLD responses were comparable to those from conventional 3D echo-planar images.Conclusion: The improved imaging efficiency and dynamic distortion correction capability afforded by 3D esEPI-BUDA are expected to benefit many EPI applications.
- 4 September 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (6) , 2375-2387
Open AccessThree‐dimensional echo‐shifted EPI with simultaneous blip‐up and blip‐down acquisitions for correcting geometric distortion
Purpose: EPI with blip-up/down acquisition (BUDA) can provide high-quality images with minimal distortions by using two readout trains with opposing phase-encoding gradients. Because of the need for two separate acquisitions, BUDA doubles the scan time and degrades the temporal resolution when compared to single-shot EPI, presenting a major challenge for many applications, particularly fMRI. This study aims at overcoming this challenge by developing an echo-shifted EPI BUDA (esEPI-BUDA) technique to acquire both blip-up and blip-down datasets in a single shot.Methods: A 3D esEPI-BUDA pulse sequence was designed by using an echo-shifting strategy to produce two EPI readout trains. These readout trains produced a pair of k-space datasets whose k-space trajectories were interleaved with opposite phase-encoding gradient directions. The two k-space datasets were separately reconstructed using a 3D SENSE algorithm, from which time-resolved B0-field maps were derived using TOPUP in FSL and then input into a forward model of joint parallel imaging reconstruction to correct for geometric distortion. In addition, Hankel structured low-rank constraint was incorporated into the reconstruction framework to improve image quality by mitigating the phase errors between the two interleaved k-space datasets.Results: The 3D esEPI-BUDA technique was demonstrated in a phantom and an fMRI study on healthy human subjects. Geometric distortions were effectively corrected in both phantom and human brain images. In the fMRI study, the visual activation volumes and their BOLD responses were comparable to those from conventional 3D echo-planar images.Conclusion: The improved imaging efficiency and dynamic distortion correction capability afforded by 3D esEPI-BUDA are expected to benefit many EPI applications.
- Open Access
- 27 April 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (3) , 910-921
Time‐dependent diffusion MRI using multiple stimulated echoes
Purpose: To develop a time‐efficient pulse sequence that acquires multiple diffusion‐weighted images with distinct diffusion times in a single shot by using multiple stimulated echoes (mSTE) with variable flip angles (VFA).Methods: The proposed diffusion‐weighted mSTE with VFA (DW‐mSTE‐VFA) sequence begins with two 90° RF pulses that straddle a diffusion gradient lobe (GD) to excite and restore one half of the magnetization into the longitudinal axis. The restored longitudinal magnetization was successively re‐excited by a series of RF pulses with VFA, each followed by another GD, to generate a set of stimulated echoes. Each of the multiple stimulated echoes was acquired with an EPI echo train. As such, the train of multiple stimulated echoes produced a set of diffusion‐weighted images with varying diffusion times in a single shot. This technique was experimentally demonstrated on a diffusion phantom, a fruit, and healthy human brain and prostate at 3 T.Results: In the phantom experiment, the mean ADC measured at different diffusion times using DW‐mSTE‐VFA were highly consistent (r = 0.999) with those from a commercial spin‐echo diffusion‐weighted EPI sequence. In the fruit and brain experiments, DW‐mSTE‐VFA exhibited similar diffusion‐time dependence to a standard diffusion‐weighted stimulated echo sequence. The ADC showed significant time dependence in the human brain (p = 0.003 in both white matter and gray matter) and prostate tissues (p = 0.003 in both peripheral zone and central gland).Conclusion: DW‐mSTE‐VFA offers a time‐efficient tool for investigating the diffusion‐time dependency in diffusion MRI studies.
- 27 April 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (3) , 910-921
Open AccessTime‐dependent diffusion MRI using multiple stimulated echoes
Purpose: To develop a time‐efficient pulse sequence that acquires multiple diffusion‐weighted images with distinct diffusion times in a single shot by using multiple stimulated echoes (mSTE) with variable flip angles (VFA).Methods: The proposed diffusion‐weighted mSTE with VFA (DW‐mSTE‐VFA) sequence begins with two 90° RF pulses that straddle a diffusion gradient lobe (GD) to excite and restore one half of the magnetization into the longitudinal axis. The restored longitudinal magnetization was successively re‐excited by a series of RF pulses with VFA, each followed by another GD, to generate a set of stimulated echoes. Each of the multiple stimulated echoes was acquired with an EPI echo train. As such, the train of multiple stimulated echoes produced a set of diffusion‐weighted images with varying diffusion times in a single shot. This technique was experimentally demonstrated on a diffusion phantom, a fruit, and healthy human brain and prostate at 3 T.Results: In the phantom experiment, the mean ADC measured at different diffusion times using DW‐mSTE‐VFA were highly consistent (r = 0.999) with those from a commercial spin‐echo diffusion‐weighted EPI sequence. In the fruit and brain experiments, DW‐mSTE‐VFA exhibited similar diffusion‐time dependence to a standard diffusion‐weighted stimulated echo sequence. The ADC showed significant time dependence in the human brain (p = 0.003 in both white matter and gray matter) and prostate tissues (p = 0.003 in both peripheral zone and central gland).Conclusion: DW‐mSTE‐VFA offers a time‐efficient tool for investigating the diffusion‐time dependency in diffusion MRI studies.
- Open Access
- 3 February 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (4) , 045001
Simultaneous multi-segment (SMSeg) EPI over multiple focal regions
Objective. This study aimed at developing a simultaneous multi-segment (SMSeg) imaging technique using a two-dimensional (2D) RF pulse in conjunction with echo planar imaging (EPI) to image multiple focal regions. Approach. The SMSeg technique leveraged periodic replicates of the excitation profile of a 2D RF pulse to simultaneously excite multiple focal regions at different locations. These locations were controlled by rotating and scaling transmit k-space trajectories. The resulting multiple isolated focal regions were projected into a composite ‘slice’ for display. GRAPPA-based parallel imaging was incorporated into SMSeg by taking advantage of coil sensitivity variations in both the phase-encoded and slice-selection directions. The SMSeg technique was implemented at 3 T in a single-shot gradient-echo EPI sequence and demonstrated in a phantom and human brains for both anatomic imaging and functional imaging. Main results. In both the phantom and the human brain, SMSeg images from three focal regions were simultaneously acquired. SMSeg imaging enabled up to a six-fold acceleration in parallel imaging without causing appreciable residual aliasing artifacts when compared with a conventional gradient-echo EPI sequence with the same acceleration factor. In the functional imaging experiment, BOLD activations associated with a visuomotor task were simultaneously detected in two non-coplanar segments (each with a size of 240 × 30 mm 2 ), corresponding to visual and motor cortices, respectively. Significance. Our study has demonstrated that SMSeg imaging can be a viable method for studying multiple focal regions simultaneously.
- 3 February 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (4) , 045001
Open AccessSimultaneous multi-segment (SMSeg) EPI over multiple focal regions
Objective. This study aimed at developing a simultaneous multi-segment (SMSeg) imaging technique using a two-dimensional (2D) RF pulse in conjunction with echo planar imaging (EPI) to image multiple focal regions. Approach. The SMSeg technique leveraged periodic replicates of the excitation profile of a 2D RF pulse to simultaneously excite multiple focal regions at different locations. These locations were controlled by rotating and scaling transmit k-space trajectories. The resulting multiple isolated focal regions were projected into a composite ‘slice’ for display. GRAPPA-based parallel imaging was incorporated into SMSeg by taking advantage of coil sensitivity variations in both the phase-encoded and slice-selection directions. The SMSeg technique was implemented at 3 T in a single-shot gradient-echo EPI sequence and demonstrated in a phantom and human brains for both anatomic imaging and functional imaging. Main results. In both the phantom and the human brain, SMSeg images from three focal regions were simultaneously acquired. SMSeg imaging enabled up to a six-fold acceleration in parallel imaging without causing appreciable residual aliasing artifacts when compared with a conventional gradient-echo EPI sequence with the same acceleration factor. In the functional imaging experiment, BOLD activations associated with a visuomotor task were simultaneously detected in two non-coplanar segments (each with a size of 240 × 30 mm 2 ), corresponding to visual and motor cortices, respectively. Significance. Our study has demonstrated that SMSeg imaging can be a viable method for studying multiple focal regions simultaneously.
- Open Access
- 6 June 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (4) , 1690-1701
Gradient‐echo‐train ‐based sub‐millisecond periodic event encoded dynamic imaging with random ( k , t )‐space undersampling: k‐t get‐SPEEDI
Purpose The gradient-echo-train-based Sub-millisecond Periodic Event Encoded Dynamic Imaging (get-SPEEDI) technique provides ultrahigh temporal resolutions (similar to 0.6 ms) for detecting rapid physiological activities, but its practical adoption can be hampered by long scan times. This study aimed at developing a more efficient variant of get-SPEEDI for reducing the scan time without degrading temporal resolution or image quality. Methods The proposed pulse sequence, named k-t get-SPEEDI, accelerated get-SPEEDI acquisition by undersampling the k-space phase-encoding lines semi-randomly. At each time frame, k-space was fully sampled in the central region whereas randomly undersampled in the outer regions. A time-series of images was reconstructed using an algorithm based on the joint partial separability and sparsity constraints. To demonstrate the performance of k-t get-SPEEDI, images of human aortic valve opening and closing were acquired with 0.6-ms temporal resolution and compared with those from conventional get-SPEEDI. Results k-t get-SPEEDI achieved a 2-fold scan time reduction over the conventional get-SPEEDI (from similar to 6 to similar to 3 min), while achieving comparable SNRs and contrast-to-noise ratio (CNRs) for visualizing the dynamic process of aortic valve: SNR/CNR approximate to$$ \approx $$ 70/38 vs. 73/39 in the k-t and conventional get-SPEEDI scans, respectively. The time courses of aortic valve area also matched well between these two sequences with a correlation coefficient of 0.86. Conclusions The k-t get-SPEEDI pulse sequence was able to half the scan time without compromising the image quality and ultrahigh temporal resolution. Additional scan time reduction may also be possible, facilitating in vivo adoptions of SPEEDI techniques.- 6 June 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (4) , 1690-1701
Open AccessGradient‐echo‐train ‐based sub‐millisecond periodic event encoded dynamic imaging with random ( k , t )‐space undersampling: k‐t get‐SPEEDI
Purpose The gradient-echo-train-based Sub-millisecond Periodic Event Encoded Dynamic Imaging (get-SPEEDI) technique provides ultrahigh temporal resolutions (similar to 0.6 ms) for detecting rapid physiological activities, but its practical adoption can be hampered by long scan times. This study aimed at developing a more efficient variant of get-SPEEDI for reducing the scan time without degrading temporal resolution or image quality. Methods The proposed pulse sequence, named k-t get-SPEEDI, accelerated get-SPEEDI acquisition by undersampling the k-space phase-encoding lines semi-randomly. At each time frame, k-space was fully sampled in the central region whereas randomly undersampled in the outer regions. A time-series of images was reconstructed using an algorithm based on the joint partial separability and sparsity constraints. To demonstrate the performance of k-t get-SPEEDI, images of human aortic valve opening and closing were acquired with 0.6-ms temporal resolution and compared with those from conventional get-SPEEDI. Results k-t get-SPEEDI achieved a 2-fold scan time reduction over the conventional get-SPEEDI (from similar to 6 to similar to 3 min), while achieving comparable SNRs and contrast-to-noise ratio (CNRs) for visualizing the dynamic process of aortic valve: SNR/CNR approximate to$$ \approx $$ 70/38 vs. 73/39 in the k-t and conventional get-SPEEDI scans, respectively. The time courses of aortic valve area also matched well between these two sequences with a correlation coefficient of 0.86. Conclusions The k-t get-SPEEDI pulse sequence was able to half the scan time without compromising the image quality and ultrahigh temporal resolution. Additional scan time reduction may also be possible, facilitating in vivo adoptions of SPEEDI techniques. - 11 December 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (5) , 2372-2379
Three‐dimensional reduced field‐of‐view imaging (3D‐rFOVI)
Purpose: This study aimed at developing a 3D reduced field‐of‐view imaging (3D‐rFOVI) technique using a 2D radiofrequency (RF) pulse, and demonstrating its ability to achieve isotropic high spatial resolution and reduced image distortion in echo planar imaging (EPI).Methods: The proposed 3D‐rFOVI technique takes advantage of a 2D RF pulse to excite a slab along the conventional slice‐selection direction (i.e., z‐direction) while limiting the spatial extent along the phase‐encoded direction (i.e., y‐direction) within the slab. The slab is phase‐encoded in both through‐slab and in‐slab phase‐encoded directions. The 3D‐rFOVI technique was implemented at 3T in gradient‐echo and spin‐echo EPI pulse sequences for functional MRI (fMRI) and diffusion‐weighted imaging (DWI), respectively. 3D‐rFOVI experiments were performed on a phantom and human brain to illustrate image distortion reduction, as well as isotropic high spatial resolution, in comparison with 3D full‐FOV imaging.Results: In both the phantom and the human brain, image voxel dislocation was substantially reduced by 3D‐rFOVI when compared with full‐FOV imaging. In the fMRI experiment with visual stimulation, 3D isotropic spatial resolution of (2 × 2 × 2 mm3) was achieved with an adequate signal‐to‐noise ratio (81.5) and blood oxygen level‐dependent (BOLD) contrast (2.5%). In the DWI experiment, diffusion‐weighted brain images with an isotropic resolution of (1 × 1 × 1 mm3) was obtained without appreciable image distortion.Conclusion: This study indicates that 3D‐rFOVI is a viable approach to 3D neuroimaging over a zoomed region.
- 11 December 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (5) , 2372-2379
Three‐dimensional reduced field‐of‐view imaging (3D‐rFOVI)
Purpose: This study aimed at developing a 3D reduced field‐of‐view imaging (3D‐rFOVI) technique using a 2D radiofrequency (RF) pulse, and demonstrating its ability to achieve isotropic high spatial resolution and reduced image distortion in echo planar imaging (EPI).Methods: The proposed 3D‐rFOVI technique takes advantage of a 2D RF pulse to excite a slab along the conventional slice‐selection direction (i.e., z‐direction) while limiting the spatial extent along the phase‐encoded direction (i.e., y‐direction) within the slab. The slab is phase‐encoded in both through‐slab and in‐slab phase‐encoded directions. The 3D‐rFOVI technique was implemented at 3T in gradient‐echo and spin‐echo EPI pulse sequences for functional MRI (fMRI) and diffusion‐weighted imaging (DWI), respectively. 3D‐rFOVI experiments were performed on a phantom and human brain to illustrate image distortion reduction, as well as isotropic high spatial resolution, in comparison with 3D full‐FOV imaging.Results: In both the phantom and the human brain, image voxel dislocation was substantially reduced by 3D‐rFOVI when compared with full‐FOV imaging. In the fMRI experiment with visual stimulation, 3D isotropic spatial resolution of (2 × 2 × 2 mm3) was achieved with an adequate signal‐to‐noise ratio (81.5) and blood oxygen level‐dependent (BOLD) contrast (2.5%). In the DWI experiment, diffusion‐weighted brain images with an isotropic resolution of (1 × 1 × 1 mm3) was obtained without appreciable image distortion.Conclusion: This study indicates that 3D‐rFOVI is a viable approach to 3D neuroimaging over a zoomed region.