AKAly Khalifa

Aly Khalifa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Aly Khalifa has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Multi-task learning for automated contouring and dose prediction in radiotherapy

    by Sangwook Kim, Aly Khalifa, Thomas G Purdie, Chris McIntosh

    Objective. Deep learning (DL)-based automated contouring and treatment planning has been proven to improve the efficiency and accuracy of radiotherapy. However, conventional radiotherapy treatment planning process has the automated contouring and treatment planning as separate tasks. Moreover in DL, the contouring and dose prediction tasks for automated treatment planning are done independently. Approach. In this study, we applied the multi-task learning (MTL) approach in order to seamlessly integrate automated contouring and voxel-based dose prediction tasks, as MTL can leverage common information between the two tasks and be able to increase the efficiency of the automated tasks. We developed our MTL framework using the two datasets: in-house prostate cancer dataset and the publicly available head and neck cancer dataset, OpenKBP. Main results. Compared to the sequential DL contouring and treatment planning tasks, our proposed method using MTL improved the mean absolute difference of dose volume histogram metrics of prostate and head and neck sites by 19.82% and 16.33%, respectively. Our MTL model for automated contouring and dose prediction tasks demonstrated enhanced dose prediction performance while maintaining or sometimes even improving the contouring accuracy. Compared to the baseline automated contouring model with the Dice score coefficients of 0.818 for prostate and 0.674 for head and neck datasets, our MTL approach achieved average scores of 0.824 and 0.716 for these datasets, respectively. Significance. Our study highlights the potential of the proposed automated contouring and planning using MTL to support the development of efficient and accurate automated treatment planning for radiotherapy.


  • Open Access

    The future of MRI in radiation therapy: Challenges and opportunities for the MR community

    by Rosie J. Goodburn, Marielle E. P. Philippens, Thierry L. Lefebvre, Aly Khalifa, Tom Bruijnen, Joshua N. Freedman, David E. J. Waddington, Eyesha Younus, Eric Aliotta, Gabriele Meliadò, et al.

    Radiation therapy is a major component of cancer treatment pathways worldwide. The main aim of this treatment is to achieve tumor control through the delivery of ionizing radiation while preserving healthy tissues for minimal radiation toxicity. Because radiation therapy relies on accurate localization of the target and surrounding tissues, imaging plays a crucial role throughout the treatment chain. In the treatment planning phase, radiological images are essential for defining target volumes and organs‐at‐risk, as well as providing elemental composition (e.g., electron density) information for radiation dose calculations. At treatment, onboard imaging informs patient setup and could be used to guide radiation dose placement for sites affected by motion. Imaging is also an important tool for treatment response assessment and treatment plan adaptation. MRI, with its excellent soft tissue contrast and capacity to probe functional tissue properties, holds great untapped potential for transforming treatment paradigms in radiation therapy. The MR in Radiation Therapy ISMRM Study Group was established to provide a forum within the MR community to discuss the unmet needs and fuel opportunities for further advancement of MRI for radiation therapy applications. During the summer of 2021, the study group organized its first virtual workshop, attended by a diverse international group of clinicians, scientists, and clinical physicists, to explore our predictions for the future of MRI in radiation therapy for the next 25 years. This article reviews the main findings from the event and considers the opportunities and challenges of reaching our vision for the future in this expanding field.


  • Open Access

    Domain adaptation of automated treatment planning from computed tomography to magnetic resonance

    by Aly Khalifa, Jeff Winter, Inmaculada Navarro, Chris McIntosh, Thomas G Purdie

    Objective. Machine learning (ML) based radiation treatment planning addresses the iterative and time-consuming nature of conventional inverse planning. Given the rising importance of magnetic resonance (MR) only treatment planning workflows, we sought to determine if an ML based treatment planning model, trained on computed tomography (CT) imaging, could be applied to MR through domain adaptation. Methods. In this study, MR and CT imaging was collected from 55 prostate cancer patients treated on an MR linear accelerator. ML based plans were generated for each patient on both CT and MR imaging using a commercially available model in RayStation 8B. The dose distributions and acceptance rates of MR and CT based plans were compared using institutional dose-volume evaluation criteria. The dosimetric differences between MR and CT plans were further decomposed into setup, cohort, and imaging domain components. Results. MR plans were highly acceptable, meeting 93.1% of all evaluation criteria compared to 96.3% of CT plans, with dose equivalence for all evaluation criteria except for the bladder wall, penile bulb, small and large bowel, and one rectum wall criteria (p < 0.05). Changing the input imaging modality (domain component) only accounted for about half of the dosimetric differences observed between MR and CT plans. Anatomical differences between the ML training set and the MR linac cohort (cohort component) were also a significant contributor. Significance. We were able to create highly acceptable MR based treatment plans using a CT-trained ML model for treatment planning, although clinically significant dose deviations from the CT based plans were observed. Future work should focus on combining this framework with atlas selection metrics to create an interpretable quality assurance QA framework for ML based treatment planning.


  • Open Access

    Performance stability evaluation of atlas-based machine learning radiation therapy treatment planning in prostate cancer

    by Leigh Conroy, Aly Khalifa, Alejandro Berlin, Chris McIntosh, Thomas G Purdie

    Atlas-based machine learning (ML) for radiation therapy (RT) treatment planning is effective at tailoring dose distributions to account for unique patient anatomies by selecting the most appropriate patients from the training database (atlases) to inform dose prediction for new patients. However, variations in clinical practice between the training dataset and a new patient to be planned may impact ML performance by confounding atlas selection. In this study, we simulated various contouring practices in prostate cancer RT to investigate the impact of changing input data on atlas-based ML treatment planning. We generated 225 ML plans for nine bespoke contouring protocol scenarios (reduced target margins, modified organ-at-risk (OAR) definitions, and inclusion of optional OARs less represented in the training database) on 25 patient datasets by applying a single, previously trained and validated ML model for prostate cancer followed by dose mimicking to create a final deliverable plan. ML treatment plans for each scenario were compared to base ML treatment plans that followed a contouring protocol consistent with the model training data. ML performance was evaluated based on atlas distance metrics that are calculated during ML dose prediction. There were significant changes between atlases selected for the base ML treatment plans and treatment plans when planning target volume margins were reduced and/or optional OARs were included. The deliverability of ML predicted dose distributions based on gamma analysis between predicted and mimicked final deliverable dose showed significant differences for seven out of eight scenarios compared with the base ML treatment plans. Overall, there were small but statistically significant dosimetric changes in predicted and mimicked dose with addition of optional OAR contours. This work presents a framework for benchmarking and performance monitoring of ML treatment planning algorithms in the context of evolving clinical practices.