Fatima Alrashdan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fatima Alrashdan has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
- Jacob T. Robinson
Rice University
13 shared publications - Joshua E. Woods
Department of Electrical and Computer Engineering, Rice University, Houston, TX, USA
5 shared publications - Abdelmotagaly Elgalad
Texas Heart Institute, Houston, TX, USA
3 shared publications Allison Post
Texas Heart Institute, Houston, TX, USA
3 shared publicationsAmanda Singer
Department of Electrical and Computer Engineering, Rice University, Houston, USA
3 shared publications- Amanda Singer
Motif Neurotech, 2450 Holcombe Blvd, Houston, TX 77021, USA
3 shared publications
Latest Publications
- Open Access
- 13 May 2026
- Published by Springer Nature in Communications Engineering
- Vol. 5  (1)
Robust magnetoelectric backscatter communication system for bioelectronic implants
Wireless communication technologies for bioelectronic implants enable remote monitoring for diagnosis and adaptive therapeutic intervention without the constraints of wired connections. However, wireless data uplink from millimeter-scale devices deep in the body struggles to achieve low power consumption while maintaining large misalignment tolerances. Here, we report a passive wireless backscatter communication system based on magnetoelectric transducers that consumes less than 0.3 pJ/bit and achieves less than 1E-6 bit error rate at a distance of 55 mm while tolerating a misalignment of 10 mm. Using this robust data uplink, we designed a wireless cardiac sensing node that can transmit electrocardiogram signals from the beating heart surface of a porcine model to a custom external transceiver using the magnetoelectric backscatter uplink. This reliable, near-zero-power communication method provides opportunities for next-generation bioelectronics to feature real-time physiological monitoring and closed-loop therapies while maintaining a small form factor and low power consumption.
- 13 May 2026
- Published by Springer Nature in Communications Engineering
- Vol. 5  (1)
Open AccessRobust magnetoelectric backscatter communication system for bioelectronic implants
Wireless communication technologies for bioelectronic implants enable remote monitoring for diagnosis and adaptive therapeutic intervention without the constraints of wired connections. However, wireless data uplink from millimeter-scale devices deep in the body struggles to achieve low power consumption while maintaining large misalignment tolerances. Here, we report a passive wireless backscatter communication system based on magnetoelectric transducers that consumes less than 0.3 pJ/bit and achieves less than 1E-6 bit error rate at a distance of 55 mm while tolerating a misalignment of 10 mm. Using this robust data uplink, we designed a wireless cardiac sensing node that can transmit electrocardiogram signals from the beating heart surface of a porcine model to a custom external transceiver using the magnetoelectric backscatter uplink. This reliable, near-zero-power communication method provides opportunities for next-generation bioelectronics to feature real-time physiological monitoring and closed-loop therapies while maintaining a small form factor and low power consumption.
- 28 August 2025
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 10  (3) , 532-544
Distributed battery-free bioelectronic implants with improved network power transfer efficiency via magnetoelectrics
Networks of miniature implants could enable simultaneous sensing and stimulation at different locations in the body, such as the heart and central or peripheral nervous system. This capability would support precise disease tracking and treatment or enable prosthetic technologies with many degrees of freedom. However, wireless power and data transfer are often inefficient through biological tissues, particularly as the number of implanted devices increases. Here we show that magnetoelectric wireless data and power transfer supports a network of millimetre-sized bioelectronic implants in which system efficiency improves with additional devices. We demonstrate wireless, battery-free networks ranging from one to six implants, where the total system efficiency increases from 0.2% to 1.3%, with each node receiving 2.2 mW at 1 cm distance. We show proof-of-concept networks of miniature spinal cord stimulators and cardiac pacing devices in large animals via efficient and robust wireless power transfer. These magnetoelectric implants provide a scalable network architecture of bioelectronic implants for next-generation electronic medicine.
- 28 August 2025
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 10  (3) , 532-544
Distributed battery-free bioelectronic implants with improved network power transfer efficiency via magnetoelectrics
Networks of miniature implants could enable simultaneous sensing and stimulation at different locations in the body, such as the heart and central or peripheral nervous system. This capability would support precise disease tracking and treatment or enable prosthetic technologies with many degrees of freedom. However, wireless power and data transfer are often inefficient through biological tissues, particularly as the number of implanted devices increases. Here we show that magnetoelectric wireless data and power transfer supports a network of millimetre-sized bioelectronic implants in which system efficiency improves with additional devices. We demonstrate wireless, battery-free networks ranging from one to six implants, where the total system efficiency increases from 0.2% to 1.3%, with each node receiving 2.2 mW at 1 cm distance. We show proof-of-concept networks of miniature spinal cord stimulators and cardiac pacing devices in large animals via efficient and robust wireless power transfer. These magnetoelectric implants provide a scalable network architecture of bioelectronic implants for next-generation electronic medicine.
- Open Access
- 27 January 2025
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 9  (6) , 985
Author Correction: Endocisternal interfaces for minimally invasive neural stimulation and recording of the brain and spinal cord
- 27 January 2025
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 9  (6) , 985
Open AccessAuthor Correction: Endocisternal interfaces for minimally invasive neural stimulation and recording of the brain and spinal cord
- Open Access
- 5 December 2024
- Published by Springer Nature in Research Square
Robust Magnetoelectric Backscatter Communication System for Bioelectronic Implants
Wireless communication technologies for bioelectronic implants enable remote monitoring for diagnosis and adaptive therapeutic intervention without the constraints of wired connections. However, wireless data uplink from millimeter-scale devices deep in the body struggles to achieve low power consumption while maintaining large misalignment tolerances. Here, we report a passive wireless backscatter communication system based on magnetoelectric transducers that consumes less than 0.3 pJ/bit and achieves less than 1E-6 bit error rate at a distance of 55 mm while tolerating a misalignment of 10 mm. Using this robust data uplink, we designed a wireless cardiac sensing node that can transmit electrocardiogram signals from the beating heart surface of a porcine model to a custom external transceiver using the magnetoelectric backscatter uplink. This reliable, near-zero-power communication method provides opportunities for next-generation bioelectronics to feature real-time physiological monitoring and closed-loop therapies while maintaining a small form factor and low power consumption.
- 5 December 2024
- Published by Springer Nature in Research Square
Open AccessRobust Magnetoelectric Backscatter Communication System for Bioelectronic Implants
Wireless communication technologies for bioelectronic implants enable remote monitoring for diagnosis and adaptive therapeutic intervention without the constraints of wired connections. However, wireless data uplink from millimeter-scale devices deep in the body struggles to achieve low power consumption while maintaining large misalignment tolerances. Here, we report a passive wireless backscatter communication system based on magnetoelectric transducers that consumes less than 0.3 pJ/bit and achieves less than 1E-6 bit error rate at a distance of 55 mm while tolerating a misalignment of 10 mm. Using this robust data uplink, we designed a wireless cardiac sensing node that can transmit electrocardiogram signals from the beating heart surface of a porcine model to a custom external transceiver using the magnetoelectric backscatter uplink. This reliable, near-zero-power communication method provides opportunities for next-generation bioelectronics to feature real-time physiological monitoring and closed-loop therapies while maintaining a small form factor and low power consumption.
- 11 November 2024
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 9  (6) , 896-904
Endocisternal interfaces for minimally invasive neural stimulation and recording of the brain and spinal cord
Minimally invasive neural interfaces can be used to diagnose, manage and treat many disorders, with reduced risks of surgical complications. However, endovascular probes lack access to key cortical, subcortical and spinal targets, and are not typically explantable after endothelialization. Here we report the development and testing, in sheep, of endocisternal neural interfaces that approach brain and spinal cord targets through inner and outer spaces filled with cerebrospinal fluid. Thus, the interfaces gain access to the entire brain convexity, to deep brain structures within the ventricles and to the spinal cord from the spinal subarachnoid space. We combined an endocisternal neural interface with wireless miniature magnetoelectrically powered bioelectronics so that it can be freely navigated percutaneously from the spinal space to the cranial subarachnoid space, and from the cranial subarachnoid space to the ventricles. In sheep, we show recording and stimulation functions, as well as repositioning of the flexible electrodes and explantation of the interface after chronic implantation. Minimally invasive endocisternal bioelectronics may enable chronic and transient therapies, particularly for stroke rehabilitation and epilepsy monitoring.
- 11 November 2024
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 9  (6) , 896-904
Endocisternal interfaces for minimally invasive neural stimulation and recording of the brain and spinal cord
Minimally invasive neural interfaces can be used to diagnose, manage and treat many disorders, with reduced risks of surgical complications. However, endovascular probes lack access to key cortical, subcortical and spinal targets, and are not typically explantable after endothelialization. Here we report the development and testing, in sheep, of endocisternal neural interfaces that approach brain and spinal cord targets through inner and outer spaces filled with cerebrospinal fluid. Thus, the interfaces gain access to the entire brain convexity, to deep brain structures within the ventricles and to the spinal cord from the spinal subarachnoid space. We combined an endocisternal neural interface with wireless miniature magnetoelectrically powered bioelectronics so that it can be freely navigated percutaneously from the spinal space to the cranial subarachnoid space, and from the cranial subarachnoid space to the ventricles. In sheep, we show recording and stimulation functions, as well as repositioning of the flexible electrodes and explantation of the interface after chronic implantation. Minimally invasive endocisternal bioelectronics may enable chronic and transient therapies, particularly for stroke rehabilitation and epilepsy monitoring.
- 25 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18  (6) , 1197-1208
A Miniature Batteryless Bioelectronic Implant Using One Magnetoelectric Transducer for Wireless Powering and PWM Backscatter Communication
Wireless minimally invasive bioelectronic implants enable a wide range of applications in healthcare, medicine, and scientific research. Magnetoelectric (ME) wireless power transfer (WPT) has emerged as a promising approach for powering miniature bio-implants because of its remarkable efficiency, safety limit, and misalignment tolerance. However, achieving low-power and high-quality uplink communication using ME remains a challenge. This paper presents a pulse-width modulated (PWM) ME backscatter uplink communication enabled by a switched-capacitor energy extraction (SCEE) technique. The SCEE rapidly extracts and dissipates the kinetic energy within the ME transducer during its ringdown period, enabling time-domain PWM in ME backscatter. Various circuit techniques are presented to realize SCEE with low power consumption. This paper also describes the high-order modeling of ME transducers to facilitate the design and analysis, which shows good matching with measurement. Our prototyping system includes a millimeter-scale ME implant with a fully integrated system-on-chip (SoC) and a portable transceiver for power transfer and bidirectional communication. SCEE is proven to induce >50% amplitude reduction within 2 ME cycles, leading to a PWM ME backscatter uplink with 17.73 kbps data rate and 0.9 pJ/bit efficiency. It also achieves 8.5 × 10 -5 bit-error-rate (BER) at a 5 cm distance, using a lightweight multi-layer-perception (MLP) decoding algorithm. Finally, the system demonstrates continuous wireless neural local-field potential (LFP) recording in an in vitro setup.
- 25 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18  (6) , 1197-1208
A Miniature Batteryless Bioelectronic Implant Using One Magnetoelectric Transducer for Wireless Powering and PWM Backscatter Communication
Wireless minimally invasive bioelectronic implants enable a wide range of applications in healthcare, medicine, and scientific research. Magnetoelectric (ME) wireless power transfer (WPT) has emerged as a promising approach for powering miniature bio-implants because of its remarkable efficiency, safety limit, and misalignment tolerance. However, achieving low-power and high-quality uplink communication using ME remains a challenge. This paper presents a pulse-width modulated (PWM) ME backscatter uplink communication enabled by a switched-capacitor energy extraction (SCEE) technique. The SCEE rapidly extracts and dissipates the kinetic energy within the ME transducer during its ringdown period, enabling time-domain PWM in ME backscatter. Various circuit techniques are presented to realize SCEE with low power consumption. This paper also describes the high-order modeling of ME transducers to facilitate the design and analysis, which shows good matching with measurement. Our prototyping system includes a millimeter-scale ME implant with a fully integrated system-on-chip (SoC) and a portable transceiver for power transfer and bidirectional communication. SCEE is proven to induce >50% amplitude reduction within 2 ME cycles, leading to a PWM ME backscatter uplink with 17.73 kbps data rate and 0.9 pJ/bit efficiency. It also achieves 8.5 × 10 -5 bit-error-rate (BER) at a 5 cm distance, using a lightweight multi-layer-perception (MLP) decoding algorithm. Finally, the system demonstrates continuous wireless neural local-field potential (LFP) recording in an in vitro setup.
- Open Access
- 12 April 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10  (15) , eadn0858
Miniature battery-free epidural cortical stimulators
Miniaturized neuromodulation systems could improve the safety and reduce the invasiveness of bioelectronic neuromodulation. However, as implantable bioelectronic devices are made smaller, it becomes difficult to store enough power for long-term operation in batteries. Here, we present a battery-free epidural cortical stimulator that is only 9 millimeters in width yet can safely receive enough wireless power using magnetoelectric antennas to deliver 14.5-volt stimulation bursts, which enables it to stimulate cortical activity on-demand through the dura. The device has digitally programmable stimulation output and centimeter-scale alignment tolerances when powered by an external transmitter. We demonstrate that this device has enough power and reliability for real-world operation by showing acute motor cortex activation in human patients and reliable chronic motor cortex activation for 30 days in a porcine model. This platform opens the possibility of simple surgical procedures for precise neuromodulation.
- 12 April 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10  (15) , eadn0858
Open AccessMiniature battery-free epidural cortical stimulators
Miniaturized neuromodulation systems could improve the safety and reduce the invasiveness of bioelectronic neuromodulation. However, as implantable bioelectronic devices are made smaller, it becomes difficult to store enough power for long-term operation in batteries. Here, we present a battery-free epidural cortical stimulator that is only 9 millimeters in width yet can safely receive enough wireless power using magnetoelectric antennas to deliver 14.5-volt stimulation bursts, which enables it to stimulate cortical activity on-demand through the dura. The device has digitally programmable stimulation output and centimeter-scale alignment tolerances when powered by an external transmitter. We demonstrate that this device has enough power and reliability for real-world operation by showing acute motor cortex activation in human patients and reliable chronic motor cortex activation for 30 days in a porcine model. This platform opens the possibility of simple surgical procedures for precise neuromodulation.
- 9 October 2023
- Published by Springer Nature in Nature Materials
- Vol. 23  (1) , 139-146
Self-rectifying magnetoelectric metamaterials for remote neural stimulation and motor function restoration
Magnetoelectric materials convert magnetic fields into electric fields. These materials are often used in wireless electronic and biomedical applications. For example, magnetoelectrics could enable the remote stimulation of neural tissue, but the optimal resonance frequencies are typically too high to stimulate neural activity. Here we describe a self-rectifying magnetoelectric metamaterial for a precisely timed neural stimulation. This metamaterial relies on nonlinear charge transport across semiconductor layers that allow the material to generate a steady bias voltage in the presence of an alternating magnetic field. We generate arbitrary pulse sequences with time-averaged voltage biases in excess of 2 V. As a result, we can use magnetoelectric nonlinear metamaterials to wirelessly stimulate peripheral nerves to restore a sensory reflex in an anaesthetized rat model and restore signal propagation in a severed nerve with latencies of less than 5 ms. Overall, these results showing the rational design of magnetoelectric metamaterials support applications in advanced biotechnology and electronics.
- 9 October 2023
- Published by Springer Nature in Nature Materials
- Vol. 23  (1) , 139-146
Self-rectifying magnetoelectric metamaterials for remote neural stimulation and motor function restoration
Magnetoelectric materials convert magnetic fields into electric fields. These materials are often used in wireless electronic and biomedical applications. For example, magnetoelectrics could enable the remote stimulation of neural tissue, but the optimal resonance frequencies are typically too high to stimulate neural activity. Here we describe a self-rectifying magnetoelectric metamaterial for a precisely timed neural stimulation. This metamaterial relies on nonlinear charge transport across semiconductor layers that allow the material to generate a steady bias voltage in the presence of an alternating magnetic field. We generate arbitrary pulse sequences with time-averaged voltage biases in excess of 2 V. As a result, we can use magnetoelectric nonlinear metamaterials to wirelessly stimulate peripheral nerves to restore a sensory reflex in an anaesthetized rat model and restore signal propagation in a severed nerve with latencies of less than 5 ms. Overall, these results showing the rational design of magnetoelectric metamaterials support applications in advanced biotechnology and electronics.
- Open Access
- 6 September 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 134  (9) , 094103
Magnetoelectrics enables large power delivery to mm-sized wireless bioelectronics
To maximize the capabilities of minimally invasive implantable bioelectronic devices, we must deliver large amounts of power to small implants; however, as devices are made smaller, it becomes more difficult to transfer large amounts of power without a wired connection. Indeed, recent work has explored creative wireless power transfer (WPT) approaches to maximize power density [the amount of power transferred divided by receiver footprint area (length × width)]. Here, we analyzed a model for WPT using magnetoelectric (ME) materials that convert an alternating magnetic field into an alternating voltage. With this model, we identify the parameters that impact WPT efficiency and optimize the power density. We find that improvements in adhesion between the laminated ME layers, clamping, and selection of material thicknesses lead to a power density of 3.1 mW/mm2, which is over four times larger than previously reported for mm-sized wireless bioelectronic implants at a depth of 1 cm or more in tissue. This improved power density allows us to deliver 31 and 56 mW to 10 and 27-mm2 ME receivers, respectively. This total power delivery is over five times larger than similarly sized bioelectronic devices powered by radiofrequency electromagnetic waves, inductive coupling, ultrasound, light, capacitive coupling, or previously reported magnetoelectrics. This increased power density opens the door to more power-intensive bioelectronic applications that have previously been inaccessible using mm-sized battery-free devices.
- 6 September 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 134  (9) , 094103
Open AccessMagnetoelectrics enables large power delivery to mm-sized wireless bioelectronics
To maximize the capabilities of minimally invasive implantable bioelectronic devices, we must deliver large amounts of power to small implants; however, as devices are made smaller, it becomes more difficult to transfer large amounts of power without a wired connection. Indeed, recent work has explored creative wireless power transfer (WPT) approaches to maximize power density [the amount of power transferred divided by receiver footprint area (length × width)]. Here, we analyzed a model for WPT using magnetoelectric (ME) materials that convert an alternating magnetic field into an alternating voltage. With this model, we identify the parameters that impact WPT efficiency and optimize the power density. We find that improvements in adhesion between the laminated ME layers, clamping, and selection of material thicknesses lead to a power density of 3.1 mW/mm2, which is over four times larger than previously reported for mm-sized wireless bioelectronic implants at a depth of 1 cm or more in tissue. This improved power density allows us to deliver 31 and 56 mW to 10 and 27-mm2 ME receivers, respectively. This total power delivery is over five times larger than similarly sized bioelectronic devices powered by radiofrequency electromagnetic waves, inductive coupling, ultrasound, light, capacitive coupling, or previously reported magnetoelectrics. This increased power density opens the door to more power-intensive bioelectronic applications that have previously been inaccessible using mm-sized battery-free devices.
- Open Access
Magnetoelectrics Enables Large Power Delivery to mm-Sized Wireless Bioelectronics
To maximize the capabilities of minimally invasive implantable bioelectronic devices, we must deliver large amounts of power to small implants; however, as devices are made smaller, it becomes more difficult to transfer large amounts of power without a wired connection. Indeed, recent work has explored creative wireless power transfer (WPT) approaches to maximize power density (the amount of power transferred divided by receiver footprint area (length × width)). Here, we analyzed a model for WPT using magnetoelectric (ME) materials that convert an alternating magnetic field into an alternating voltage. With this model, we identify the parameters that impact WPT efficiency and optimize the power density. We find that improvements in adhesion between the laminated ME layers, clamping, and selection of material thicknesses lead to a power density of 3.1 mW/mm 2 , which is over 4 times larger than previously reported for mm-sized wireless bioelectronic implants at a depth of 1 cm or more in tissue. This improved power density allows us to deliver 31 mW and 56 mW to 10-mm 2 and 27-mm 2 ME receivers, respectively. This total power delivery is over 5 times larger than similarly sized bioelectronic devices powered by radiofrequency electromagnetic waves, inductive coupling, ultrasound, light, capacitive coupling, or previously reported magnetoelectrics. This increased power density opens the door to more power-intensive bioelectronic applications that have previously been inaccessible using mm-sized battery-free devices.
Open AccessMagnetoelectrics Enables Large Power Delivery to mm-Sized Wireless Bioelectronics
To maximize the capabilities of minimally invasive implantable bioelectronic devices, we must deliver large amounts of power to small implants; however, as devices are made smaller, it becomes more difficult to transfer large amounts of power without a wired connection. Indeed, recent work has explored creative wireless power transfer (WPT) approaches to maximize power density (the amount of power transferred divided by receiver footprint area (length × width)). Here, we analyzed a model for WPT using magnetoelectric (ME) materials that convert an alternating magnetic field into an alternating voltage. With this model, we identify the parameters that impact WPT efficiency and optimize the power density. We find that improvements in adhesion between the laminated ME layers, clamping, and selection of material thicknesses lead to a power density of 3.1 mW/mm 2 , which is over 4 times larger than previously reported for mm-sized wireless bioelectronic implants at a depth of 1 cm or more in tissue. This improved power density allows us to deliver 31 mW and 56 mW to 10-mm 2 and 27-mm 2 ME receivers, respectively. This total power delivery is over 5 times larger than similarly sized bioelectronic devices powered by radiofrequency electromagnetic waves, inductive coupling, ultrasound, light, capacitive coupling, or previously reported magnetoelectrics. This increased power density opens the door to more power-intensive bioelectronic applications that have previously been inaccessible using mm-sized battery-free devices.