Christopher P. Cop
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christopher P. Cop has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Alfred C. Schouten
Department of Biomechanical Engineering, University of Twente, Enschede, The Netherlands; Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
2 shared publications- Alfred C. Schouten
Department of Biomechanical Engineering, Faculty of Mechanical Engineering, Delft University of Technology, Mekelweg 2, 2628 CD, Delft, The Netherlands
2 shared publications - Bart F. J. M. Koopman
Department of Biomechanical Engineering, University of Twente, The Netherlands
2 shared publications - Massimo Sartori
Department of Biomechanical Engineering, University of Twente, Enschede, The Netherlands
2 shared publications Bart F. J. M. Koopman
University of Twente
1 shared publicationBart Koopman
Department of Biomechanical Engineering, University of Twente, Enschede, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 13 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (3) , 987-997
The Simultaneous Model-Based Estimation of Joint, Muscle, and Tendon Stiffness is Highly Sensitive to the Tendon Force-Strain Relationship
Objective: Accurate estimation of stiffness across anatomical levels (i.e., joint, muscle, and tendon) in vivo has long been a challenge in biomechanics. Recent advances in electromyography (EMG)-driven musculoskeletal modeling have allowed the non-invasive estimation of stiffness during dynamic joint rotations. Nevertheless, validation has been limited to the joint level due to a lack of simultaneous in vivo experimental measurements of muscle and tendon stiffness. Methods: With a focus on the triceps surae, we employed a novel perturbation-based experimental technique informed by dynamometry and ultrasonography to derive reference stiffness at the joint, muscle, and tendon levels simultaneously. Here, we propose a new EMG-driven model-based approach that does not require external joint perturbation, nor ultrasonography, to estimate multi-level stiffness. We present a novel set of closed-form equations that enables the person-specific tuning of musculoskeletal parameters dictating biological stiffness, including passive force-length relationships in modeled muscles and tendons. Results: Calibrated EMG-driven musculoskeletal models estimated the reference data with average normalized root-mean-square error $\approx$ 20%. Moreover, only when calibrated tendons were approximately four times more compliant than typically modeled, our approach could estimate multi-level reference stiffness. Conclusion: EMG-driven musculoskeletal models can be calibrated on a larger set of reference data to provide more realistic values for the biomechanical variables across multiple anatomical levels. Moreover, the tendon models that are typically used in musculoskeletal modeling are too stiff. Significance: Calibrated musculoskeletal models informed by experimental measurements give access to an augmented range of biomechanical variables that might not be easily measured with sensors alone.
- 13 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (3) , 987-997
Open AccessThe Simultaneous Model-Based Estimation of Joint, Muscle, and Tendon Stiffness is Highly Sensitive to the Tendon Force-Strain Relationship
Objective: Accurate estimation of stiffness across anatomical levels (i.e., joint, muscle, and tendon) in vivo has long been a challenge in biomechanics. Recent advances in electromyography (EMG)-driven musculoskeletal modeling have allowed the non-invasive estimation of stiffness during dynamic joint rotations. Nevertheless, validation has been limited to the joint level due to a lack of simultaneous in vivo experimental measurements of muscle and tendon stiffness. Methods: With a focus on the triceps surae, we employed a novel perturbation-based experimental technique informed by dynamometry and ultrasonography to derive reference stiffness at the joint, muscle, and tendon levels simultaneously. Here, we propose a new EMG-driven model-based approach that does not require external joint perturbation, nor ultrasonography, to estimate multi-level stiffness. We present a novel set of closed-form equations that enables the person-specific tuning of musculoskeletal parameters dictating biological stiffness, including passive force-length relationships in modeled muscles and tendons. Results: Calibrated EMG-driven musculoskeletal models estimated the reference data with average normalized root-mean-square error $\approx$ 20%. Moreover, only when calibrated tendons were approximately four times more compliant than typically modeled, our approach could estimate multi-level reference stiffness. Conclusion: EMG-driven musculoskeletal models can be calibrated on a larger set of reference data to provide more realistic values for the biomechanical variables across multiple anatomical levels. Moreover, the tendon models that are typically used in musculoskeletal modeling are too stiff. Significance: Calibrated musculoskeletal models informed by experimental measurements give access to an augmented range of biomechanical variables that might not be easily measured with sensors alone.
- Open Access
- 9 November 2022
- Published by Elsevier in Journal of Biomechanics
- Vol. 145, 111383
Electromyography-driven model-based estimation of ankle torque and stiffness during dynamic joint rotations in perturbed and unperturbed conditions
- 9 November 2022
- Published by Elsevier in Journal of Biomechanics
- Vol. 145, 111383
Open AccessElectromyography-driven model-based estimation of ankle torque and stiffness during dynamic joint rotations in perturbed and unperturbed conditions
- 2 October 2021
- Published by Springer Nature
- p. 507-511
A Muscle Model Incorporating Fiber Architecture Features for the Estimation of Joint Stiffness During Dynamic Movement
- 2 October 2021
- Published by Springer Nature
- p. 507-511
A Muscle Model Incorporating Fiber Architecture Features for the Estimation of Joint Stiffness During Dynamic Movement
- Open Access
- 1 July 2021
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 3 (3) , 033002
Unifying system identification and biomechanical formulations for the estimation of muscle, tendon and joint stiffness during human movement
In vivo joint stiffness estimation during time-varying conditions remains an open challenge. Multiple communities, e.g. system identification and biomechanics, have tackled the problem from different perspectives and using different methods, each of which entailing advantages and limitations, often complementary. System identification formulations provide data-driven estimates of stiffness at the joint level, while biomechanics often relies on musculoskeletal models to estimate stiffness at multiple levels, i.e. joint, muscle, and tendon. Collaboration across these two scientific communities seems to be a logical step toward a reliable multi-level understanding of joint stiffness. However, differences at the theoretical, computational, and experimental levels have limited inter-community interaction. In this article we present a roadmap to achieve a unified framework for the estimation of time-varying stiffness in the composite human neuromusculoskeletal system during movement. We present our perspective on future developments to obtain data-driven system identification and musculoskeletal models that are compatible at the theoretical, computational, and experimental levels. Moreover, we propose a novel combined closed-loop paradigm, in which reference estimates of joint stiffness via system identification are decomposed into underlying muscle and tendon contribution via high-density-electromyography-driven musculoskeletal modeling. We highlight the need for aligning experimental requirements to be able to compare both joint stiffness formulations. Unifying both biomechanics’ and system identification’s formulations is a necessary step for truly generalizing stiffness estimation across individuals, movement conditions, training and impairment levels. From an application point of view, this is central for enabling patient-specific neurorehabilitation therapies, as well as biomimetic control of assistive robotic technologies. The roadmap we propose could serve as an inspiration for future collaborations across broadly different scientific communities to truly understand joint stiffness bio- and neuromechanics.
- 1 July 2021
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 3 (3) , 033002
Open AccessUnifying system identification and biomechanical formulations for the estimation of muscle, tendon and joint stiffness during human movement
In vivo joint stiffness estimation during time-varying conditions remains an open challenge. Multiple communities, e.g. system identification and biomechanics, have tackled the problem from different perspectives and using different methods, each of which entailing advantages and limitations, often complementary. System identification formulations provide data-driven estimates of stiffness at the joint level, while biomechanics often relies on musculoskeletal models to estimate stiffness at multiple levels, i.e. joint, muscle, and tendon. Collaboration across these two scientific communities seems to be a logical step toward a reliable multi-level understanding of joint stiffness. However, differences at the theoretical, computational, and experimental levels have limited inter-community interaction. In this article we present a roadmap to achieve a unified framework for the estimation of time-varying stiffness in the composite human neuromusculoskeletal system during movement. We present our perspective on future developments to obtain data-driven system identification and musculoskeletal models that are compatible at the theoretical, computational, and experimental levels. Moreover, we propose a novel combined closed-loop paradigm, in which reference estimates of joint stiffness via system identification are decomposed into underlying muscle and tendon contribution via high-density-electromyography-driven musculoskeletal modeling. We highlight the need for aligning experimental requirements to be able to compare both joint stiffness formulations. Unifying both biomechanics’ and system identification’s formulations is a necessary step for truly generalizing stiffness estimation across individuals, movement conditions, training and impairment levels. From an application point of view, this is central for enabling patient-specific neurorehabilitation therapies, as well as biomimetic control of assistive robotic technologies. The roadmap we propose could serve as an inspiration for future collaborations across broadly different scientific communities to truly understand joint stiffness bio- and neuromechanics.