JMJaiver Macea

Jaiver Macea

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jaiver Macea has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Anatomy-corrected metabolic asymmetry predicts seizure freedom after surgery in focal cortical dysplasia

    by Jeroen Gijs, Evy Cleeren, Jaiver Macea, Wim Vandenberghe, Aline Delva, Greet Vanderlinden, Koen Van Laere, Wies Deckers, Steven Smeijers, Tom Theys, et al.

    Precise lesion localisation is central to favourable surgical outcomes in patients with drug-resistant epilepsy due to focal cortical dysplasia. We validated the Anatomy-Corrected Asymmetry Index of fluorodeoxyglucose positron emission tomography to objectively delineate regions of hypometabolism and predict surgical outcome in patients with focal cortical dysplasia. We first established normative Anatomy-Corrected Asymmetry Index thresholds using five independent and heterogeneous healthy control cohorts (n = 179) to assess reproducibility. We subsequently validated our findings in 40 pathologically confirmed focal cortical dysplasia patients who underwent resective surgery. The primary analysis assessed the association between the extent of resection of defined hypometabolic clusters and 24-month seizure freedom (Engel Class I). After excluding subjects with segmentation artefacts to ensure accurate threshold definition, we established a normative threshold of -19 with a minimum cluster size of 2.0 mL. In the patient cohort, 29 subjects had high-quality segmentations. Patients with at least one localising cluster achieved significantly higher seizure freedom rates compared to those without clusters (76.5% vs. 22.2%, P = 0.014). The percentage of resected hypometabolic volume was significantly associated with Engel Class I outcome (P = 0.011). Sensitivity analysis demonstrated that a more permissive threshold of -16 identified localising clusters in two additional seizure-free patients who were false negatives at the standard threshold. The Anatomy-Corrected Asymmetry Index provides a standardised metric that predicts seizure freedom in focal cortical dysplasia epilepsy surgery. Clinical implementation requires rigorous quality control of anatomical segmentations to ensure diagnostic accuracy. The online version contains supplementary material available at 10.1007/s00259-026-07864-9.

  • Open Access

    Automated Sleep Staging in Epilepsy Using Deep Learning on Standard Electroencephalogram and Wearable Data

    by Jaiver Macea, Elisabeth R. M. Heremans, Renee Proost, Maarten De Vos, Wim Van Paesschen

    Automated sleep staging on wearable data could improve our understanding and management of epilepsy. This study evaluated sleep scoring by a deep learning model on 223 night‐sleep recordings from 50 patients measured in the hospital with an electroencephalogram (EEG) and a wearable device. The model scored the sleep stage of every 30‐s epoch on the EEG and wearable data, and we compared the output with a clinical expert on 20 nights, each for a different patient. The Bland–Altman analysis examined differences in the automated staging in both modalities, and using mixed‐effect models, we explored sleep differences between patients with and without seizures. Overall, we found moderate accuracy and Cohen's kappa on the model scoring of standard EEG (0.73 and 0.59) and the wearable (0.61 and 0.43) versus the clinical expert. F1 scores also varied between patients and the modalities. The sensitivity varied by sleep stage and was very low for stage N1. Moreover, sleep staging on the wearable data underestimated the duration of most sleep macrostructure parameters except N2. On the other hand, patients with seizures during the hospital admission slept more each night (6.37, 95% confidence interval [CI] 5.86–7.87) compared with patients without seizures (5.68, 95% CI 5.24–6.13), p = 0.001, but also spent more time in stage N2. In conclusion, wearable EEG and accelerometry could monitor sleep in patients with epilepsy, and our approach can help automate the analysis. However, further steps are essential to improve the model performance before clinical implementation. Trial Registration: The SeizeIT2 trial was registered in clinicaltrials.gov, NCT04284072


  • Open Access

    Tailoring antiseizure treatment with a wearable device: A proof‐of‐concept study in absence epilepsy

    by Jaiver Macea, Christos Chatzichristos, Miguel Bhagubai, Maarten De Vos, Wim Van Paesschen

    Objective: Typical absence seizures are underreported. We aimed to improve patient care using a wearable electroencephalograph (wEEG) at home and assess a machine learning (ML) pipeline for absence detection. Methods: Patients with typical absences used a wEEG device 12–24 h 1 week after antiseizure medication (ASM) adjustments. Three‐hertz generalized spike–wave discharges (SWDs) ≥ 3 s were used as absence surrogates. After manual inspection, we used the results to guide medical treatment. The outcomes were seizure freedom, number of consecutive measurements without relapse, and side effects. Afterward, we used the ML pipeline on the recordings, and a neurologist reviewed the output. Review time and diagnostic performance were compared with manual inspection. Results: Nineteen patients (12 female, median age = 24 years) were followed for a median of 5 months (range = 1–12). The median recording time for each session was 21.3 h (range = 10–24). Fifteen patients (79%) were seizure‐free during the last measurement, including seven of 11 (63%) diagnosed with refractory epilepsy. Ten patients relapsed after a median of 1–2 recordings (range = 1–6) without 3‐Hz SWDs. Side effects occurred in 21% of patients. Manual file inspection identified 806 3‐Hz SWDs of ≥3 s. The ML pipeline reduced a neurologist's median review time for 24‐h wEEG from 27 (range = 10–45) to 4.3 min (range = .1–10), with a sensitivity, precision, F1‐score, and false positives per hour of .8, .95, .87, and .007, respectively. Significance: Home‐based wEEG allows patient monitoring after ASM adjustments, improving absence seizure management. The ML‐based pipeline performed well and was crucial in reducing review time.


  • Open Access

    Cardiorespiratory disturbances in focal impaired awareness seizures: Insights from wearable ECG monitoring

    by Jaiver Macea, Lauren Swinnen, Carolina Varon, Maarten De Vos, Wim Van Paesschen


  • Wearable detection of tonic seizures in childhood epilepsy: An exploratory cohort study

    by Renee Proost, Jaiver Macea, Lieven Lagae, Wim Van Paesschen, Katrien Jansen

    Objective: To investigate the performance of a multimodal wearable device for the offline detection of tonic seizures (TS) in a pediatric childhood epilepsy cohort, with a focus on patients with Lennox–Gastaut syndrome.Methods: Parallel with prolonged video‐electroencephalography (EEG), the Plug 'n Patch system, a multimodal wearable device using the Sensor Dot and replaceable electrode adhesives, was used to detect TS. Multiple biosignals were recorded: behind‐the‐ear EEG, surface electromyography, electrocardiography, and accelerometer/gyroscope. Biosignals were annotated blindly by a neurologist. Seizure characteristics were described, and performance was assessed by sensitivity, positive predictive value (PPV), F1 score, and false alarm rate (FAR) per hour. Performance was compared to seizure diaries kept by the caretaker.Results: Ninety‐nine TS were detected in 13 patients. Seven patients (54%) had Lennox–Gastaut syndrome and six patients (46%) had other forms of (developmental) epileptic encephalopathies or drug‐resistant epilepsy. All but one patient had intellectual disability. Overall sensitivity was 41%, with a PPV of 9%, an F1 score of 14%, and a median FAR per hour of 0.75. Performance increased to an F1 score of 66% for nightly seizures lasting at least 10 s (sensitivity 66%, PPV 66%) and 71% for nightly seizures lasting at least 20 s (sensitivity 62%, PPV 82%). For these seizures there were no false alarms in 10 of 13 patients. Sensitivity of seizure diaries reached a maximum of 52% for prolonged (≥20 s) nightly seizures, even though caretakers slept in the same room.Significance: We showed that it is feasible to use a multimodal wearable device with multiple adhesive sites in children with epilepsy and intellectual disability. For prolonged nightly seizures, offline manual detection of TS outperformed seizure diaries. The recognition of seizure‐specific signatures using multiple modalities can help in the development of automated TS detection algorithms.


  • Open Access

    The Power of ECG in Semi-Automated Seizure Detection in Addition to Two-Channel behind-the-Ear EEG

    by Miguel Bhagubai, Kaat Vandecasteele, Lauren Swinnen, Jaiver Macea, Christos Chatzichristos, Maarten De Vos, Wim Van Paesschen

    Long-term home monitoring of people living with epilepsy cannot be achieved using the standard full-scalp electroencephalography (EEG) coupled with video. Wearable seizure detection devices, such as behind-the-ear EEG (bte-EEG), offer an unobtrusive method for ambulatory follow-up of this population. Combining bte-EEG with electrocardiography (ECG) can enhance automated seizure detection performance. However, such frameworks produce high false alarm rates, making visual review necessary. This study aimed to evaluate a semi-automated multimodal wearable seizure detection framework using bte-EEG and ECG. Using the SeizeIT1 dataset of 42 patients with focal epilepsy, an automated multimodal seizure detection algorithm was used to produce seizure alarms. Two reviewers evaluated the algorithm’s detections twice: (1) using only bte-EEG data and (2) using bte-EEG, ECG, and heart rate signals. The readers achieved a mean sensitivity of 59.1% in the bte-EEG visual experiment, with a false detection rate of 6.5 false detections per day. Adding ECG resulted in a higher mean sensitivity (62.2%) and a largely reduced false detection rate (mean of 2.4 false detections per day), as well as an increased inter-rater agreement. The multimodal framework allows for efficient review time, making it beneficial for both clinicians and patients.


  • Open Access

    In‐hospital and home‐based long‐term monitoring of focal epilepsy with a wearable electroencephalographic device: Diagnostic yield and user experience

    by Jaiver Macea, Miguel Bhagubai, Victoria Broux, Maarten De Vos, Wim Van Paesschen

    Objective: The aim is to report the performance of an electroencephalogram (EEG) seizure‐detector algorithm on data obtained with a wearable device (WD) in patients with focal refractory epilepsy and their experience.Methods: Patients used a WD, the Sensor Dot (SD), to measure two channels of EEG using dry electrode patches during presurgical evaluation and at home for up to 8 months. An automated seizure detection algorithm flagged EEG regions with possible seizures, which we reviewed to evaluate the algorithm's diagnostic yield. In addition, we collected data on usability, side effects, and patient satisfaction with an electronic seizure diary application (Helpilepsy).Results: Sixteen inpatients used the SD for up to 5 days and had 21 seizures. Sixteen outpatients used the device for up to 8 months and reported 101 focal impaired awareness seizures during the periods selected for analysis. Focal seizure detection sensitivity based on behind‐the‐ear EEG was 52% in inpatients and 23% in outpatients. False detections/h, positive predictive value (PPV), and F1 scores were 7.13%, .11%, and .002% for inpatients and 7.77%, .04%, and .001% for outpatients. Artifacts and low signal quality contributed to poor performance metrics. The seizure detector identified 19 nonreported seizures during sleep, when the signal quality was better. Regarding patients' experience, the likelihood of using the device at 6 months was 62%, and side effects were the main reason for dropping out. Finally, daily and monthly questionnaire completion rates were 33% and 65%, respectively.Significance: Focal seizure detection sensitivity based on behind‐the‐ear EEG was 52% in inpatients and 23% in outpatients, with high false alarm rates and low PPV and F1 scores. This unobtrusive wearable seizure detection device was well received but had side effects. The current workflow and low performance limit its implementation in clinical practice. We suggest different steps to improve these performance metrics and patient experience.


  • Open Access

    Accurate detection of typical absence seizures in adults and children using a two‐channel electroencephalographic wearable behind the ears

    by Lauren Swinnen, Christos Chatzichristos, Katrien Jansen, Lieven Lagae, Chantal Depondt, Laura Seynaeve, Evelien Vancaester, Annelies Van Dycke, Jaiver Macea, Kaat Vandecasteele, et al.

    Summary: Objective: Patients with absence epilepsy sensitivity <10% of their absences. The clinical gold standard to assess absence epilepsy is a 24‐h electroencephalographic (EEG) recording, which is expensive, obtrusive, and time‐consuming to review. We aimed to (1) investigate the performance of an unobtrusive, two‐channel behind‐the‐ear EEG‐based wearable, the Sensor Dot (SD), to detect typical absences in adults and children; and (2) develop a sensitive patient‐specific absence seizure detection algorithm to reduce the review time of the recordings.Methods: We recruited 12 patients (median age = 21 years, range = 8–50; seven female) who were admitted to the epilepsy monitoring units of University Hospitals Leuven for a 24‐h 25‐channel video‐EEG recording to assess their refractory typical absences. Four additional behind‐the‐ear electrodes were attached for concomitant recording with the SD. Typical absences were defined as 3‐Hz spike‐and‐wave discharges on EEG, lasting 3 s or longer. Seizures on SD were blindly annotated on the full recording and on the algorithm‐labeled file and consequently compared to 25‐channel EEG annotations. Patients or caregivers were asked to keep a seizure diary. Performance of the SD and seizure diary were measured using the F1 score.Results: We concomitantly recorded 284 absences on video‐EEG and SD. Our absence detection algorithm had a sensitivity of .983 and false positives per hour rate of .9138. Blind reading of full SD data resulted in sensitivity of .81, precision of .89, and F1 score of .73, whereas review of the algorithm‐labeled files resulted in scores of .83, .89, and .87, respectively. Patient self‐reporting gave sensitivity of .08, precision of 1.00, and F1 score of .15.Significance: Using the wearable SD, epileptologists were able to reliably detect typical absence seizures. Our automated absence detection algorithm reduced the review time of a 24‐h recording from 1‐2 h to around 5–10 min.


  • Open Access

    The power of ECG in multimodal patient‐specific seizure monitoring: Added value to an EEG‐based detector using limited channels

    by Kaat Vandecasteele, Thomas De Cooman, Christos Chatzichristos, Evy Cleeren, Lauren Swinnen, Jaiver Macea Ortiz, Sabine Van Huffel, Matthias Dümpelmann, Andreas Schulze‐Bonhage, Maarten De Vos, et al.

    Objective: Wearable seizure detection devices could provide more reliable seizure documentation outside the hospital compared to seizure self‐reporting by patients, which is the current standard. Previously, during the SeizeIT1 project, we studied seizure detection based on behind‐the‐ear electroencephalography (EEG). However, the obtained sensitivities were too low for practical use, because not all seizures are associated with typical ictal EEG patterns. Therefore, in this paper, we aim to develop a multimodal automated seizure detection algorithm integrating behind‐the‐ear EEG and electrocardiography (ECG) for detecting focal seizures. In this framework, we quantified the added value of ECG to behind‐the‐ear EEG.Methods: This study analyzed three multicenter databases consisting of 135 patients having focal epilepsy and a total of 896 seizures. A patient‐specific multimodal automated seizure detection algorithm was developed using behind‐the‐ear/temporal EEG and single‐lead ECG. The EEG and ECG data were processed separately using machine learning methods. A late integration approach was applied for fusing those predictions.Results: The multimodal algorithm outperformed the EEG‐based algorithm in two of three databases, with an increase of 11% and 8% in sensitivity for the same false alarm rate.Significance: ECG can be of added value to an EEG‐based seizure detection algorithm using only behind‐the‐ear/temporal lobe electrodes for patients with focal epilepsy.