Yuliya Liush
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuliya Liush has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Kateryna Bratkovska
National University Zaporizhzhia Polytechnic
3 shared publications - Alexander Shram
National University Zaporizhzhia Polytechnic, 64, Universytetska Str., Zaporizhzhia, 69011, Ukraine
2 shared publications - Anatolii Zabolotnyi
Національний університет «Запорізька політехніка
1 shared publication - Denys Fedosha
Національний університет «Запорізька політехніка
1 shared publication - Dmytro Politaiev
National University Zaporizhzhia Polytechnic
1 shared publication - Vera Dyachenko
Національний університет «Запорізька політехніка
1 shared publication
Latest Publications
- 16 July 2025
- Published by Springer Nature
- p. 326-335
Methodology for Determining the Optimal Operating Mode of Energy Storage Systems in Industrial Enterprises
- 16 July 2025
- Published by Springer Nature
- p. 326-335
Methodology for Determining the Optimal Operating Mode of Energy Storage Systems in Industrial Enterprises
- Open Access
- 5 July 2024
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1 (8),p. 49-54
Construction of the structure of rural electric networks taking into account the availability of renewable sources of electricity
It is noted that although the share of renewable electricity sources continues to grow and develop rapidly, the industry still faces many challenges, including how to continue to reduce electricity losses and annualized costs, improve operation and maintenance efficiency, maintain grid stability, ensure safety and reliability of the power supply system containing renewable sources of electrical energy. It is shown that an effective solution to these problems is possible only on the basis of the analysis of the prospects for the development of local electric power systems that contain renewable sources of electric energy, the development of technical and organizational support mechanisms that will contribute to the construction of modern system (schematic) solutions. It is proposed to apply the potential surface method for building the optimal structure of the rural electrical network during its design and modernization in the presence of renewable sources of electrical energy, which allows optimizing the structure of the network from the point of view of electrical energy losses and reducing annualized costs. The algorithm for forming the structure of power supply systems is described, which implements the simultaneous solution of the tasks of determining the number of load nodes, distributing electrical receivers between them, determining the design of power sources, taking into account the discreteness of the design of system elements. The results of numerical modeling based on the proposed algorithm are presented on the example of solving the problem of reconstruction of a section of the rural electricity network.
- 5 July 2024
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1 (8),p. 49-54
Open AccessConstruction of the structure of rural electric networks taking into account the availability of renewable sources of electricity
It is noted that although the share of renewable electricity sources continues to grow and develop rapidly, the industry still faces many challenges, including how to continue to reduce electricity losses and annualized costs, improve operation and maintenance efficiency, maintain grid stability, ensure safety and reliability of the power supply system containing renewable sources of electrical energy. It is shown that an effective solution to these problems is possible only on the basis of the analysis of the prospects for the development of local electric power systems that contain renewable sources of electric energy, the development of technical and organizational support mechanisms that will contribute to the construction of modern system (schematic) solutions. It is proposed to apply the potential surface method for building the optimal structure of the rural electrical network during its design and modernization in the presence of renewable sources of electrical energy, which allows optimizing the structure of the network from the point of view of electrical energy losses and reducing annualized costs. The algorithm for forming the structure of power supply systems is described, which implements the simultaneous solution of the tasks of determining the number of load nodes, distributing electrical receivers between them, determining the design of power sources, taking into account the discreteness of the design of system elements. The results of numerical modeling based on the proposed algorithm are presented on the example of solving the problem of reconstruction of a section of the rural electricity network.
- Open Access
- 22 June 2022
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 1
STUDY OF THE CONDENSER’S OPERATING CHARACTERISTICS OF THE NPP UNIT
The paper shows that the technical condition of condensing devices of steam turbines largely determines the amount of electricity losses, reliable and economical operation of NPP units, and the modernization of steam turbine capacitors will provide a significant increase in electricity generation with relatively low capital investment compared to construction of new NPP power units. Analysis of the perfection of the heat transfer process in the condenser according to the principles of thermoeconomic diagnostics to identify the causes of abnormal operation of the power conversion system showed that the main causes of load reduction are determined by rising cooling water temperature and deviation of steam pressure from normal assessment of contamination of the heat transfer surface, which significantly affects the reduction of electricity generation. The modernization main points of the capacitor of the Zaporizhzhya NPP power unit № 3 on the principle of "block-modular" design developed by PJSC "Turboatom" and the characteristics of the capacitor provided by the new design are considered. The method of thermal calculation of the condenser with the use of iterative methods, which takes into account the presence of air leakage in the space of the condenser and the appearance of contamination of the heat exchange surface, is given. The increase of electric power at the generator terminals at change of steam load factor and pollution thickness is calculated and analyzed. An analytical dependence of the investigated parameters of reducing the increase in electric power during the modernization of the capacitor is obtained and the interpretation of the results is carried out. The work emphasizes the importance of processing the results of diagnostics and monitoring of the technical condition of steam turbines condensing devices and information about their impact on the amount of electric power generation.
- 22 June 2022
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 1
Open AccessSTUDY OF THE CONDENSER’S OPERATING CHARACTERISTICS OF THE NPP UNIT
The paper shows that the technical condition of condensing devices of steam turbines largely determines the amount of electricity losses, reliable and economical operation of NPP units, and the modernization of steam turbine capacitors will provide a significant increase in electricity generation with relatively low capital investment compared to construction of new NPP power units. Analysis of the perfection of the heat transfer process in the condenser according to the principles of thermoeconomic diagnostics to identify the causes of abnormal operation of the power conversion system showed that the main causes of load reduction are determined by rising cooling water temperature and deviation of steam pressure from normal assessment of contamination of the heat transfer surface, which significantly affects the reduction of electricity generation. The modernization main points of the capacitor of the Zaporizhzhya NPP power unit № 3 on the principle of "block-modular" design developed by PJSC "Turboatom" and the characteristics of the capacitor provided by the new design are considered. The method of thermal calculation of the condenser with the use of iterative methods, which takes into account the presence of air leakage in the space of the condenser and the appearance of contamination of the heat exchange surface, is given. The increase of electric power at the generator terminals at change of steam load factor and pollution thickness is calculated and analyzed. An analytical dependence of the investigated parameters of reducing the increase in electric power during the modernization of the capacitor is obtained and the interpretation of the results is carried out. The work emphasizes the importance of processing the results of diagnostics and monitoring of the technical condition of steam turbines condensing devices and information about their impact on the amount of electric power generation.
- Open Access
- 30 June 2021
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 3 (8(111)) , 60-67
Determination of the electrical power increase at the generator terminals of a nuclear power plant unit at different condenser states
It is shown that the technical condition of condensing devices of steam turbines largely determines the amount of electricity losses, reliable and economical operation of NPP units. Analysis of the heat transfer process in the condenser showed that the main causes of load reduction are determined by rising cooling water temperature and deviation of steam pressure from normal value. It is shown that among diagnostic parameters except leakage volumes there must be an assessment of contamination of the heat transfer surface which significantly affects the reduction of electricity generation. The modernization main points of the condenser of the Zaporizhzhya NPP power unit No. 3 on the principle of "block-modular" design developed by PJSC "Turboatom" and the characteristics of the condenser provided by the new design are considered. To reflect the real mode of operation of the condensing unit, it is proposed to model the contamination of the heat exchange surface and the presence of leakages in the condenser space using the method of thermal calculation of the condenser by iterative methods. It was found that reducing the increase in electricity generation as a result of the effects of the study factors can partially or even completely absorb the effect of upgrading the condenser plant. It will provide a significant increase in electricity generation with relatively low capital investment compared to construction of new NPP power units and improve the accuracy of power generation forecasts.
- 30 June 2021
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 3 (8(111)) , 60-67
Open AccessDetermination of the electrical power increase at the generator terminals of a nuclear power plant unit at different condenser states
It is shown that the technical condition of condensing devices of steam turbines largely determines the amount of electricity losses, reliable and economical operation of NPP units. Analysis of the heat transfer process in the condenser showed that the main causes of load reduction are determined by rising cooling water temperature and deviation of steam pressure from normal value. It is shown that among diagnostic parameters except leakage volumes there must be an assessment of contamination of the heat transfer surface which significantly affects the reduction of electricity generation. The modernization main points of the condenser of the Zaporizhzhya NPP power unit No. 3 on the principle of "block-modular" design developed by PJSC "Turboatom" and the characteristics of the condenser provided by the new design are considered. To reflect the real mode of operation of the condensing unit, it is proposed to model the contamination of the heat exchange surface and the presence of leakages in the condenser space using the method of thermal calculation of the condenser by iterative methods. It was found that reducing the increase in electricity generation as a result of the effects of the study factors can partially or even completely absorb the effect of upgrading the condenser plant. It will provide a significant increase in electricity generation with relatively low capital investment compared to construction of new NPP power units and improve the accuracy of power generation forecasts.