Victor Ivel
Victor Ivel has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Yuliya Gerasimova
Manash Kozybayev North Kazakhstan University NPLC
4 shared publications - P. A. Petrov
Manash Kozybayev North Kazakhstan University NPLC
3 shared publications - Sayat Moldakhmetov
Manash Kozybayev North Kazakhstan University
3 shared publications - Fatimah Sidi
Universiti Putra Malaysia
1 shared publication - Gailya Aubakirova
Manash Kozybayev North Kazakhstan University, Kazakhstan
1 shared publication - Lili Nurliyana Abdullah
Universiti Putra Malaysia
1 shared publication
Latest Publications
- Open Access
- 28 August 2025
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 4 (5 (136)) , 15-27
Automated real-time electrocardiogram diagnosis based on the modified Pan-Tompkins algorithm for long-term monitoring systems
The object of this study is the process of automated analysis of the electrocardiographic signal (ECS) during long-term monitoring in real time, carried out by mobile wireless systems. The study considers the problem related to the insufficient accuracy of automated diagnostics during long-term monitoring of the electrocardiogram (ECG) under conditions of limited computing resources and the presence of noise. A modified Pan-Tompkins algorithm for determining the boundaries of the QRS system has been developed. Based on this algorithm, the PCard software module for the hardware and software system was implemented, enabling high-quality automated diagnostics both under the standard mode and during long-term ECG monitoring in 12 leads in real time. The PCard software module allows for ECG registration, digital filtering, measurement and calculation of electrocardiographic parameters, automatic determination of diagnostic criteria and diagnostic conclusions, formation of a general diagnostic conclusion of ECG, as well as medical processing of ECG. The high quality of the diagnostic analysis was confirmed by the obtained accuracy rates of the algorithm for determining normal complexes – 99.99%, for determining ventricular complexes – 99.90%, for determining various pathologies – 98.43%. The ECG processing time was about 4.7 seconds for a 40-minute record. The proposed method for determining the boundaries of QRS complexes is based on the finite difference method, which distinguishes it from common methodologies using spectral analysis, wavelet transforms, or Fourier transforms. This methodology simplifies determining the parameters of the basic ECG elements and significantly reduces the amount of calculations, which generally increases the processing time and reduces the required volume of system resources
- 28 August 2025
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 4 (5 (136)) , 15-27
Open AccessAutomated real-time electrocardiogram diagnosis based on the modified Pan-Tompkins algorithm for long-term monitoring systems
The object of this study is the process of automated analysis of the electrocardiographic signal (ECS) during long-term monitoring in real time, carried out by mobile wireless systems. The study considers the problem related to the insufficient accuracy of automated diagnostics during long-term monitoring of the electrocardiogram (ECG) under conditions of limited computing resources and the presence of noise. A modified Pan-Tompkins algorithm for determining the boundaries of the QRS system has been developed. Based on this algorithm, the PCard software module for the hardware and software system was implemented, enabling high-quality automated diagnostics both under the standard mode and during long-term ECG monitoring in 12 leads in real time. The PCard software module allows for ECG registration, digital filtering, measurement and calculation of electrocardiographic parameters, automatic determination of diagnostic criteria and diagnostic conclusions, formation of a general diagnostic conclusion of ECG, as well as medical processing of ECG. The high quality of the diagnostic analysis was confirmed by the obtained accuracy rates of the algorithm for determining normal complexes – 99.99%, for determining ventricular complexes – 99.90%, for determining various pathologies – 98.43%. The ECG processing time was about 4.7 seconds for a 40-minute record. The proposed method for determining the boundaries of QRS complexes is based on the finite difference method, which distinguishes it from common methodologies using spectral analysis, wavelet transforms, or Fourier transforms. This methodology simplifies determining the parameters of the basic ECG elements and significantly reduces the amount of calculations, which generally increases the processing time and reduces the required volume of system resources
- 30 June 2025
- Published by Toraighyrov University in Bulletin of Toraighyrov University. Energetics series
- No. 2,2025,p. 142-155
РЕАЛИЗАЦИЯ ЭНЕРГОЭФФЕКТИВНОЙ СИСТЕМЫ ПЕРЕДАЧИ ЭЛЕКТРОКАРДИОСИГНАЛА ПО ЛОКАЛЬНОЙ WI-FI-СЕТИ
Исследование посвящено проблеме мобильности систем мониторинга пациентов, которым требуется постоянное подключение. Длительный мониторинг электрокардиограммы (ЭКГ) необходим для диагностики заболеваний, но традиционные системы не обеспечивают обратную связь в реальном времени. Беспроводная передача данных повышает комфорт пациента, но требует оптимизации энергопотребления. В работе рассматривается беспроводная система передачи электрокардиосигнала (ЭКС) на базе технологии Wi-Fi с использованием микроконтроллера ESP32, предназначенная для реализации Холтеровского мониторинга. Объектом исследования являются процессы измерения и передачи ЭКС по локальной беспроводной сети. Основной проблемой, решаемой в рамках работы, является минимизация энергопотребления автономной части системы за счёт оптимизации алгоритмов передачи и использования энергосберегающих режимов работы модуля ESP32. Разработан метод пакетной передачи ЭКС с распределением вычислений между двумя ядрами микроконтроллера, что позволило достичь высокой скважности передачи и сократить средний ток потребления. Экспериментально установлено, что при передаче пакетов размером 3450 байт и использовании режима Modem-sleep средний ток потребления передатчика составляет 50,5 мА. Проведён расчёт времени автономной работы системы, которое составило около 69 часов, что подтверждено экспериментальными данными. Полученные результаты демонстрируют возможность создания энергоэффективной беспроводной системы мониторинга ЭКГ с возможностью длительной автономной работы и передачей данных в режиме реального времени. Ключевые слова: беспроводной мониторинг, ЭКГ, ESP32, энергоэффективность, холтеровский монитор, Wi-Fi.
- 30 June 2025
- Published by Toraighyrov University in Bulletin of Toraighyrov University. Energetics series
- No. 2,2025,p. 142-155
РЕАЛИЗАЦИЯ ЭНЕРГОЭФФЕКТИВНОЙ СИСТЕМЫ ПЕРЕДАЧИ ЭЛЕКТРОКАРДИОСИГНАЛА ПО ЛОКАЛЬНОЙ WI-FI-СЕТИ
Исследование посвящено проблеме мобильности систем мониторинга пациентов, которым требуется постоянное подключение. Длительный мониторинг электрокардиограммы (ЭКГ) необходим для диагностики заболеваний, но традиционные системы не обеспечивают обратную связь в реальном времени. Беспроводная передача данных повышает комфорт пациента, но требует оптимизации энергопотребления. В работе рассматривается беспроводная система передачи электрокардиосигнала (ЭКС) на базе технологии Wi-Fi с использованием микроконтроллера ESP32, предназначенная для реализации Холтеровского мониторинга. Объектом исследования являются процессы измерения и передачи ЭКС по локальной беспроводной сети. Основной проблемой, решаемой в рамках работы, является минимизация энергопотребления автономной части системы за счёт оптимизации алгоритмов передачи и использования энергосберегающих режимов работы модуля ESP32. Разработан метод пакетной передачи ЭКС с распределением вычислений между двумя ядрами микроконтроллера, что позволило достичь высокой скважности передачи и сократить средний ток потребления. Экспериментально установлено, что при передаче пакетов размером 3450 байт и использовании режима Modem-sleep средний ток потребления передатчика составляет 50,5 мА. Проведён расчёт времени автономной работы системы, которое составило около 69 часов, что подтверждено экспериментальными данными. Полученные результаты демонстрируют возможность создания энергоэффективной беспроводной системы мониторинга ЭКГ с возможностью длительной автономной работы и передачей данных в режиме реального времени. Ключевые слова: беспроводной мониторинг, ЭКГ, ESP32, энергоэффективность, холтеровский монитор, Wi-Fi.
- Open Access
- 30 August 2024
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 4 (9 (130)) , 34-43
Hardware-software implementation of a local Wi-Fi network for the transmission of biomedical signals
The object of this study is a wireless local Wi-Fi network for broadcasting biomedical signals, its structure, and principles of construction. The task of minimizing the power consumption of a Wi-Fi transmitter has been addressed, which provides the possibility of building a wireless system for long-term monitoring of biomedical signals. As a result, a functional diagram of a wireless Holter monitoring system based on an ESP32 microcontroller was constructed, which includes a subsystem for setting up and diagnosing system units using MATLAB software packages, an ECG signal generator, and a multifunctional PCIe board from National Instruments. Evaluation criteria and methods for minimizing power consumption by an autonomous Wi-Fi transmitter have been proposed. Methods for synchronizing the working cycles of the transmitter and receiver of the Holter monitoring system were determined. A procedure for determining the optimal biosignal measurement frequency is presented, at which the distortion of ECG signals would be minimal, which means that the signal could be transmitted without losses. The concept of constructing an algorithm for implementing a program for a Wi-Fi transmitter has been developed, ensuring parallel execution of ECG signal measurement operations and their transmission over a local network. The data from semi-naturalistic tests with an experimental Holter monitoring system with a pre-setup subsystem and using external measuring devices, a computer, and the MATLAB software environment are presented. A comparative analysis of the experimental data with primary ECG signals and ECG signals at the receiver output showed a fairly stable correspondence between the input and output ECG signals. The proposed algorithms make it possible to reduce the average current consumption of the ESP32 microcontroller to 50.5 mA. The results of the study demonstrate the possibility of constructing an energy-efficient wireless system for long-term monitoring of biomedical signals based on the Wi-Fi interface
- 30 August 2024
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 4 (9 (130)) , 34-43
Open AccessHardware-software implementation of a local Wi-Fi network for the transmission of biomedical signals
The object of this study is a wireless local Wi-Fi network for broadcasting biomedical signals, its structure, and principles of construction. The task of minimizing the power consumption of a Wi-Fi transmitter has been addressed, which provides the possibility of building a wireless system for long-term monitoring of biomedical signals. As a result, a functional diagram of a wireless Holter monitoring system based on an ESP32 microcontroller was constructed, which includes a subsystem for setting up and diagnosing system units using MATLAB software packages, an ECG signal generator, and a multifunctional PCIe board from National Instruments. Evaluation criteria and methods for minimizing power consumption by an autonomous Wi-Fi transmitter have been proposed. Methods for synchronizing the working cycles of the transmitter and receiver of the Holter monitoring system were determined. A procedure for determining the optimal biosignal measurement frequency is presented, at which the distortion of ECG signals would be minimal, which means that the signal could be transmitted without losses. The concept of constructing an algorithm for implementing a program for a Wi-Fi transmitter has been developed, ensuring parallel execution of ECG signal measurement operations and their transmission over a local network. The data from semi-naturalistic tests with an experimental Holter monitoring system with a pre-setup subsystem and using external measuring devices, a computer, and the MATLAB software environment are presented. A comparative analysis of the experimental data with primary ECG signals and ECG signals at the receiver output showed a fairly stable correspondence between the input and output ECG signals. The proposed algorithms make it possible to reduce the average current consumption of the ESP32 microcontroller to 50.5 mA. The results of the study demonstrate the possibility of constructing an energy-efficient wireless system for long-term monitoring of biomedical signals based on the Wi-Fi interface
- Open Access
- 30 June 2022
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 3 (4 (117)) , 31-39
Application of artificial neural network for wheat yield forecasting
A given model of yield forecasting using an artificial neural network connects the wheat crop with the amount of productive moisture in the soil, soil fertility, weather, and factors in the presence of pests, diseases, and weeds. The difficulty of creating a yield forecast system is in the correct choice of predictors that have the greatest impact on yield. To build the model, moisture in the 100 cm layer of the soil, the content of nitrogen, phosphorus, humus, and soil acidity in the soil were used as input parameters. The amount of precipitation over 4 months, the average air temperature for the same period, as well as the presence of diseases, pests, and weeds were also taken into consideration. Data on 13 districts of the North Kazakhstan region in the period from 2008 to 2017 were used. The output parameter was the yield of spring wheat over the same time period. The relative importance of input variables in relation to the output variable was used to determine the weight values of input variables. An artificial neural network of error backpropagation was used as a method. The advantage of this method is that the quality of the forecast increases with a large amount of training data, as well as the ability to model nonlinear relationships between different data sources. After training the artificial neural network and obtaining predictive data, good results were achieved for predicting wheat yields (p=0.52, mean absolute error in percentage (MAPE)=12.02 %, root mean square error (RMSE)=3.368). Thus, it is assumed that the developed model for forecasting wheat yields based on data can be easily adapted for other crops and places and will allow the adoption of the right strategies to ensure food security
- 30 June 2022
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 3 (4 (117)) , 31-39
Open AccessApplication of artificial neural network for wheat yield forecasting
A given model of yield forecasting using an artificial neural network connects the wheat crop with the amount of productive moisture in the soil, soil fertility, weather, and factors in the presence of pests, diseases, and weeds. The difficulty of creating a yield forecast system is in the correct choice of predictors that have the greatest impact on yield. To build the model, moisture in the 100 cm layer of the soil, the content of nitrogen, phosphorus, humus, and soil acidity in the soil were used as input parameters. The amount of precipitation over 4 months, the average air temperature for the same period, as well as the presence of diseases, pests, and weeds were also taken into consideration. Data on 13 districts of the North Kazakhstan region in the period from 2008 to 2017 were used. The output parameter was the yield of spring wheat over the same time period. The relative importance of input variables in relation to the output variable was used to determine the weight values of input variables. An artificial neural network of error backpropagation was used as a method. The advantage of this method is that the quality of the forecast increases with a large amount of training data, as well as the ability to model nonlinear relationships between different data sources. After training the artificial neural network and obtaining predictive data, good results were achieved for predicting wheat yields (p=0.52, mean absolute error in percentage (MAPE)=12.02 %, root mean square error (RMSE)=3.368). Thus, it is assumed that the developed model for forecasting wheat yields based on data can be easily adapted for other crops and places and will allow the adoption of the right strategies to ensure food security
- Open Access
- 30 June 2021
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 3 (3 (111)) , 15-23
Development of a hardware and software model of a rocket motion correction system
The paper deals with the development of a motion correction system for an unguided rocket of a certain class. The existing method for calculating the rocket flight range based on the dependence of flight path on the initial rocket pitch angle and average parameters of disturbing effects does not provide the required accuracy of the specified flight range. This is mainly due to uncontrolled range wind deviations in the flight area. At the same time, conducting test rocket launches to identify dispersion characteristics and improve the target accuracy leads to significant material costs. Therefore, computer simulation is the most promising approach for studying rocket dispersion laws and developing a motion correction system for the unguided rocket on this basis. When developing the correction system, classical differential equations were used describing the aerodynamics of a variable-mass rocket, as well as adaptive control methods with a reference model. As a result of the study, a method for recording a program that implements the reference model on the Arduino Due platform was developed. A general Simulink model that simulates the process of rocket flight path correction was built. A half-scale rocket flight model with a correction block was developed. Based on this model, a series of experiments were carried out, which showed a high degree of rocket target accuracy due to rocket path correction. The results make it possible to take the developed system as a basis for developing a practical path correction system for Grad rockets
- 30 June 2021
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 3 (3 (111)) , 15-23
Open AccessDevelopment of a hardware and software model of a rocket motion correction system
The paper deals with the development of a motion correction system for an unguided rocket of a certain class. The existing method for calculating the rocket flight range based on the dependence of flight path on the initial rocket pitch angle and average parameters of disturbing effects does not provide the required accuracy of the specified flight range. This is mainly due to uncontrolled range wind deviations in the flight area. At the same time, conducting test rocket launches to identify dispersion characteristics and improve the target accuracy leads to significant material costs. Therefore, computer simulation is the most promising approach for studying rocket dispersion laws and developing a motion correction system for the unguided rocket on this basis. When developing the correction system, classical differential equations were used describing the aerodynamics of a variable-mass rocket, as well as adaptive control methods with a reference model. As a result of the study, a method for recording a program that implements the reference model on the Arduino Due platform was developed. A general Simulink model that simulates the process of rocket flight path correction was built. A half-scale rocket flight model with a correction block was developed. Based on this model, a series of experiments were carried out, which showed a high degree of rocket target accuracy due to rocket path correction. The results make it possible to take the developed system as a basis for developing a practical path correction system for Grad rockets