Kenichi Kobara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kenichi Kobara has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Daisuke Fujita
Department of Physical Therapy, Faculty of Rehabilitation, Kawasaki University of Medical Welfare, Kurashiki, Japan
13 shared publicationsHiroshi Osaka
Department of Physical Therapy, Faculty of Rehabilitation, Kawasaki University of Medical Welfare, Kurashiki, Japan
10 shared publicationsHisashi Takahashi
Department of Physical Therapy, Faculty of Rehabilitation, Kawasaki University of Medical Welfare, Kurashiki, Japan
9 shared publicationsSusumu Watanabe
Department of Rehabilitation, Kawasaki University of Medical Welfare, Kurashiki, Japan
8 shared publicationsYasuyuki Nagata
Department of Physical Therapy, Faculty of Rehabilitation, Kawasaki University of Medical Welfare, Kurashiki, Japan
6 shared publicationsTadanobu Suehiro
Department of Physical Therapy, Faculty of Rehabilitation, Kawasaki University of Medical Welfare, Kurashiki, Japan
5 shared publications
Latest Publications
- 5 August 2025
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 50 (3) , 290-296
Effect of fluctuation in the parallel force exerted on the buttocks on discomfort during sitting in experimental ergonomic chair with tilt-in-space and reclining functions
Background: Tilt-in-space and reclining functions are commonly used to improve comfort in ergonomic seating. However, fluctuations in shear (parallel) forces on the buttocks during postural changes may cause discomfort, yet this relationship is not well understood. Objectives: To examine how combined use of tilt-in-space and reclining functions affects fluctuations in parallel forces on the buttocks, and how these fluctuations relate to subjective discomfort. Study design: Cross-sectional experimental study. Methods: Nineteen healthy adult males (mean age: 27.7 ± 10.3 years) participated. An experimental ergonomic chair was used under 2 conditions: 1 with a seat-cover assembly that conforms to the back shape, and a control condition with a flat back-support. Participants experienced a 10 degrees tilt-in-space and reclining angles from 100 degrees to 130 degrees. Fluctuations in parallel forces on the buttocks were measured using a force plate, and subjective discomfort was assessed with a visual analog scale. Stepwise multiple regression was used to analyze associations between force fluctuation and discomfort. Results: The seat-cover assembly condition resulted in significantly lower visual analog scale scores (median: 4, interquartile range: 0–13) compared to the control (median: 46, interquartile range: 24–72; p < 0.01). Regression analysis revealed that only the fluctuation in parallel forces significantly predicted discomfort (β = 0.722, R² = 0.507, p < 0.01). Conclusions: Fluctuations in parallel forces during tilt and recline use are significantly associated with discomfort. Ergonomic designs that reduce shear force variability may enhance seating comfort during postural adjustments.
- 5 August 2025
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 50 (3) , 290-296
Effect of fluctuation in the parallel force exerted on the buttocks on discomfort during sitting in experimental ergonomic chair with tilt-in-space and reclining functions
Background: Tilt-in-space and reclining functions are commonly used to improve comfort in ergonomic seating. However, fluctuations in shear (parallel) forces on the buttocks during postural changes may cause discomfort, yet this relationship is not well understood. Objectives: To examine how combined use of tilt-in-space and reclining functions affects fluctuations in parallel forces on the buttocks, and how these fluctuations relate to subjective discomfort. Study design: Cross-sectional experimental study. Methods: Nineteen healthy adult males (mean age: 27.7 ± 10.3 years) participated. An experimental ergonomic chair was used under 2 conditions: 1 with a seat-cover assembly that conforms to the back shape, and a control condition with a flat back-support. Participants experienced a 10 degrees tilt-in-space and reclining angles from 100 degrees to 130 degrees. Fluctuations in parallel forces on the buttocks were measured using a force plate, and subjective discomfort was assessed with a visual analog scale. Stepwise multiple regression was used to analyze associations between force fluctuation and discomfort. Results: The seat-cover assembly condition resulted in significantly lower visual analog scale scores (median: 4, interquartile range: 0–13) compared to the control (median: 46, interquartile range: 24–72; p < 0.01). Regression analysis revealed that only the fluctuation in parallel forces significantly predicted discomfort (β = 0.722, R² = 0.507, p < 0.01). Conclusions: Fluctuations in parallel forces during tilt and recline use are significantly associated with discomfort. Ergonomic designs that reduce shear force variability may enhance seating comfort during postural adjustments.
- Open Access
- 1 January 2025
- Published by Society of Physical Therapy Science in Journal of Physical Therapy Science
- Vol. 37 (12) , 584-588
Influence of adjustable back-support on the effectiveness of seat-cover assembly in reducing the shear force applied to the buttocks during combined reclining and tilt-in-space functions
[Purpose] We aimed to investigate how the effectiveness of the seat-cover assembly (ScA) in reducing shear force fluctuations on the buttocks is influenced by the incorporation of reclining, tilt-in-space, and adjustable back-support functions. [Participants and Methods] Fifteen healthy adult males participated (mean age: 33.1 ± 10.4 years). Parallel forces, which were used as indicators of shear forces on the buttocks, were measured using a portable force plate. Participants were exposed to a 10° tilt and a reclining angle between 100° and 130° using an experimental chair equipped with either an adjustable back-support (aBS) or a flat back-support (control condition). [Results] The peak parallel forces were 13.3 ± 1.7% of body weight (%BW) and 11.6 ± 1.9%BW under the aBS and control conditions, respectively. The median range of parallel force fluctuations was 10.2 (9.4‒10.7) %BW with the aBS and 8.8 (8.0‒10.5) %BW with the control. The aBS condition showed significantly higher values than the control condition for both metrics. [Conclusion] These results suggest that integrating adjustable back-support mechanisms compromises the effectiveness of the ScA in stabilizing shear forces during combined reclining and tilt-in-space functions. Future designs should optimize back-support systems to preserve the effectiveness of ScA while maintaining postural alignment.
- 1 January 2025
- Published by Society of Physical Therapy Science in Journal of Physical Therapy Science
- Vol. 37 (12) , 584-588
Open AccessInfluence of adjustable back-support on the effectiveness of seat-cover assembly in reducing the shear force applied to the buttocks during combined reclining and tilt-in-space functions
[Purpose] We aimed to investigate how the effectiveness of the seat-cover assembly (ScA) in reducing shear force fluctuations on the buttocks is influenced by the incorporation of reclining, tilt-in-space, and adjustable back-support functions. [Participants and Methods] Fifteen healthy adult males participated (mean age: 33.1 ± 10.4 years). Parallel forces, which were used as indicators of shear forces on the buttocks, were measured using a portable force plate. Participants were exposed to a 10° tilt and a reclining angle between 100° and 130° using an experimental chair equipped with either an adjustable back-support (aBS) or a flat back-support (control condition). [Results] The peak parallel forces were 13.3 ± 1.7% of body weight (%BW) and 11.6 ± 1.9%BW under the aBS and control conditions, respectively. The median range of parallel force fluctuations was 10.2 (9.4‒10.7) %BW with the aBS and 8.8 (8.0‒10.5) %BW with the control. The aBS condition showed significantly higher values than the control condition for both metrics. [Conclusion] These results suggest that integrating adjustable back-support mechanisms compromises the effectiveness of the ScA in stabilizing shear forces during combined reclining and tilt-in-space functions. Future designs should optimize back-support systems to preserve the effectiveness of ScA while maintaining postural alignment.
- Open Access
- 1 January 2024
- Published by Society of Physical Therapy Science in Journal of Physical Therapy Science
- Vol. 36 (9) , 471-475
Influence of chair seat forward tilt angle on upper limb dexterity improvement in seated tasks: a pilot study
[Purpose] This study aimed to investigate the influence of seat-forward tilt angles on improving upper limb dexterity in seated tasks and to contribute to the development of seating strategies. [Participants and Methods] Seventeen healthy men (age, 20.0 ± 0.5 years; height, 175.1 ± 4.9 cm; and body weight, 63.8 ± 6.7 kg) participated in this study. The forward tilt angles of the seat were set at 0°, 15°, and 30°, with knee pads used in all conditions. The Purdue Pegboard task was used to assess upper limb dexterity, with participants inserting pins into holes in the board for 60 s. Additionally, a visual analog scale was used to evaluate the perceived ease of the task. [Results] The Purdue Pegboard task scores were 30.0 ± 2.5, 30.6 ± 2.7, and 32.5 ± 2.9 for the 0°, 15°, and 30° conditions, respectively. The visual analog scale scores were 75.3 ± 9.8, 76.4 ± 14.6, and 84.1 ± 11.1 for the 0°, 15°, and 30° conditions, respectively. Both measurements showed significantly higher values under the 30° condition than under the other two conditions. [Conclusion] These results suggest that a tilt angle of 30° provides the most significant ease and upper limb dexterity.
- 1 January 2024
- Published by Society of Physical Therapy Science in Journal of Physical Therapy Science
- Vol. 36 (9) , 471-475
Open AccessInfluence of chair seat forward tilt angle on upper limb dexterity improvement in seated tasks: a pilot study
[Purpose] This study aimed to investigate the influence of seat-forward tilt angles on improving upper limb dexterity in seated tasks and to contribute to the development of seating strategies. [Participants and Methods] Seventeen healthy men (age, 20.0 ± 0.5 years; height, 175.1 ± 4.9 cm; and body weight, 63.8 ± 6.7 kg) participated in this study. The forward tilt angles of the seat were set at 0°, 15°, and 30°, with knee pads used in all conditions. The Purdue Pegboard task was used to assess upper limb dexterity, with participants inserting pins into holes in the board for 60 s. Additionally, a visual analog scale was used to evaluate the perceived ease of the task. [Results] The Purdue Pegboard task scores were 30.0 ± 2.5, 30.6 ± 2.7, and 32.5 ± 2.9 for the 0°, 15°, and 30° conditions, respectively. The visual analog scale scores were 75.3 ± 9.8, 76.4 ± 14.6, and 84.1 ± 11.1 for the 0°, 15°, and 30° conditions, respectively. Both measurements showed significantly higher values under the 30° condition than under the other two conditions. [Conclusion] These results suggest that a tilt angle of 30° provides the most significant ease and upper limb dexterity.
- Open Access
- 1 January 2024
- Published by Society of Physical Therapy Science in Journal of Physical Therapy Science
- Vol. 36 (8) , 420-424
Temporal changes in postural control strategy through single-leg stance practice with active restriction of knee movement
[Purpose] This study aimed to examine and verify temporal changes in lower limb joint action after 2 weeks of single-leg stance training under active restriction of knee movement. [Participants and Methods] The participants included 28 healthy adult females (mean age, 19.6 ± 1.0 years). A stabile meter was used to measure the center of pressure sway as an index of ankle joint action. In addition, a triaxial accelerometer was used to measure pelvic and knee sways as indices of hip and knee joint actions, respectively. We established two experimental groups: an active-restriction group and an unrestricted group. Measurements of lower limb joint actions were recorded thrice during single-leg stance exercises during the first session of practice, the third session 1 week later, and the sixth session 2 weeks later. [Results] Both groups exhibited shorter total trajectory lengths in sessions three and six than in the first session. The active restriction group showed less knee sway in later sessions, whereas the unrestricted group showed reduced pelvic sway in the third session. [Conclusion] Single-leg stance exercises with active restriction of knee movement may alter the strategy of lower limb joint action.
- 1 January 2024
- Published by Society of Physical Therapy Science in Journal of Physical Therapy Science
- Vol. 36 (8) , 420-424
Open AccessTemporal changes in postural control strategy through single-leg stance practice with active restriction of knee movement
[Purpose] This study aimed to examine and verify temporal changes in lower limb joint action after 2 weeks of single-leg stance training under active restriction of knee movement. [Participants and Methods] The participants included 28 healthy adult females (mean age, 19.6 ± 1.0 years). A stabile meter was used to measure the center of pressure sway as an index of ankle joint action. In addition, a triaxial accelerometer was used to measure pelvic and knee sways as indices of hip and knee joint actions, respectively. We established two experimental groups: an active-restriction group and an unrestricted group. Measurements of lower limb joint actions were recorded thrice during single-leg stance exercises during the first session of practice, the third session 1 week later, and the sixth session 2 weeks later. [Results] Both groups exhibited shorter total trajectory lengths in sessions three and six than in the first session. The active restriction group showed less knee sway in later sessions, whereas the unrestricted group showed reduced pelvic sway in the third session. [Conclusion] Single-leg stance exercises with active restriction of knee movement may alter the strategy of lower limb joint action.
- 10 October 2023
- Published by Taylor & Francis in Disability and Rehabilitation: Assistive Technology
- Vol. 19 (5) , 1916-1922
Effect of shape of back support adjustment on shear force applied to buttocks when tilt-in-space and reclining functions are combined in wheelchairs
Purpose: This study aimed to investigate the effect of the shape of the back support adjustment on the shear force applied to the buttocks when tilt-in-space and reclining functions are combined in wheelchairs.Materials and Methods: Fourteen healthy adult men were included in the study. The force plate was used to measure the parallel force as shear force. The measurement posture, leaning against the back support of an experimental chair, was a comfortable sitting posture. The tilt-in-space angle was set to 15(degrees). The back support was inclined at increasing angles, starting from the upright position (IUP), proceeding to a fully reclined position (FRP), and returning to the upright position (RUP). The experimental conditions were as follows: adjusting the back-support shape (aBS) and non-adjusting the back support shape (non-aBS).Results: Positive values indicate a parallel force applied to the buttocks posteriorly. The average values in the aBS condition were 3.4 +/- 2.3, 13.6 +/- 2.2, and -7.1 +/- 2.4% body weight in the IUP, FRP, and RUP, respectively. The average values in the non-aBS condition were 3.8 +/- 2.5, 11.4 +/- 2.1, and -6.2 +/- 3.1% body weight in the IUP, FRP, and RUP, respectively. There were significant differences between the two conditions in FRP (p < 0.01).Conclusion: These findings suggest that the shape of the back support adjustment function increased the shear force applied to the buttocks posteriorly when the back support was inclined backwards using both the tilt-in-space and reclining functions.
- 10 October 2023
- Published by Taylor & Francis in Disability and Rehabilitation: Assistive Technology
- Vol. 19 (5) , 1916-1922
Effect of shape of back support adjustment on shear force applied to buttocks when tilt-in-space and reclining functions are combined in wheelchairs
Purpose: This study aimed to investigate the effect of the shape of the back support adjustment on the shear force applied to the buttocks when tilt-in-space and reclining functions are combined in wheelchairs.Materials and Methods: Fourteen healthy adult men were included in the study. The force plate was used to measure the parallel force as shear force. The measurement posture, leaning against the back support of an experimental chair, was a comfortable sitting posture. The tilt-in-space angle was set to 15(degrees). The back support was inclined at increasing angles, starting from the upright position (IUP), proceeding to a fully reclined position (FRP), and returning to the upright position (RUP). The experimental conditions were as follows: adjusting the back-support shape (aBS) and non-adjusting the back support shape (non-aBS).Results: Positive values indicate a parallel force applied to the buttocks posteriorly. The average values in the aBS condition were 3.4 +/- 2.3, 13.6 +/- 2.2, and -7.1 +/- 2.4% body weight in the IUP, FRP, and RUP, respectively. The average values in the non-aBS condition were 3.8 +/- 2.5, 11.4 +/- 2.1, and -6.2 +/- 3.1% body weight in the IUP, FRP, and RUP, respectively. There were significant differences between the two conditions in FRP (p < 0.01).Conclusion: These findings suggest that the shape of the back support adjustment function increased the shear force applied to the buttocks posteriorly when the back support was inclined backwards using both the tilt-in-space and reclining functions.
- Open Access
- 1 January 2023
- Published by Society of Physical Therapy Science in Journal of Physical Therapy Science
- Vol. 35 (11) , 722-726
Effectiveness of knee pad as an additional device for wheelchairs in improving upper-limb dexterity during seated tasks: a pilot study
[Purpose] This study aimed to examine how supporting the knee from the front with a knee pad affected upper-limb dexterity while sitting. [Participants and Methods] A total of 14 healthy adult males were included in the study. As a measure of upper-limb dexterity, the number of pins was counted when the Purdue pegboard test was performed for 60 seconds. In addition, the ease of task performance was assessed using the visual analogue scale. There were two experimental conditions, with and without knee pad. The paired t-test was used to detect differences between the two conditions. A p-value of 0.05 was considered statistically significant. [Results] The Purdue pegboard test was 29.4 ± 2.5 and 27.9 ± 3.6 pins with and without knee pad, respectively. The VAS was 76.1 ± 10.3 and 62.9 ± 14.1 with and without knee pad, respectively. Both measured values were significantly higher with knee pad than without. [Conclusion] Supporting the knees from the front with knee pad improves upper-limb functionality while sitting, making it easier to perform seated tasks.
- 1 January 2023
- Published by Society of Physical Therapy Science in Journal of Physical Therapy Science
- Vol. 35 (11) , 722-726
Open AccessEffectiveness of knee pad as an additional device for wheelchairs in improving upper-limb dexterity during seated tasks: a pilot study
[Purpose] This study aimed to examine how supporting the knee from the front with a knee pad affected upper-limb dexterity while sitting. [Participants and Methods] A total of 14 healthy adult males were included in the study. As a measure of upper-limb dexterity, the number of pins was counted when the Purdue pegboard test was performed for 60 seconds. In addition, the ease of task performance was assessed using the visual analogue scale. There were two experimental conditions, with and without knee pad. The paired t-test was used to detect differences between the two conditions. A p-value of 0.05 was considered statistically significant. [Results] The Purdue pegboard test was 29.4 ± 2.5 and 27.9 ± 3.6 pins with and without knee pad, respectively. The VAS was 76.1 ± 10.3 and 62.9 ± 14.1 with and without knee pad, respectively. Both measured values were significantly higher with knee pad than without. [Conclusion] Supporting the knees from the front with knee pad improves upper-limb functionality while sitting, making it easier to perform seated tasks.
- Open Access
- 8 July 2021
- Published by Hindawi Limited in Rehabilitation Research and Practice
- Vol. 2021, 1-7
Immediate Effect of Restricted Knee Extension on Ground Reaction Force and Trunk Acceleration during Walking
Gait parameters calculated from trunk acceleration reflect the features of gait; however, they cannot evaluate the gait pattern corresponding to the gait cycle. This study is aimed at investigating the differences in gait parameters calculated from trunk acceleration during gait corresponding to the gait cycle in healthy subjects with restricted knee extension. Participants included eight healthy volunteers who walked normally (NW) and with knee orthosis that restricted knee extension (ER). The ground reaction force (GRF), joint angles, and trunk acceleration during walking were measured using four force plates, a three-dimensional motion analysis system, and an inertial measurement unit. The peak GRF of the vertical components, joint ranges of motion, and moments of force were analyzed. The root mean square (RMS) and amplitude peak ratio (AR) of autocorrelation function were calculated from the trunk acceleration waveform. The first peak GRF and peak ankle dorsiflexion angles significantly increased during ER. The peak hip extension, knee flexion, knee extension angles, and the peak moment of knee extension significantly decreased during ER compared to that during NW. The acceleration AR significantly decreased during ER compared to that during NW. There was no significant difference in the RMS between the two conditions. The acceleration AR may show the temporal postural structure with restricted knee extension from the terminal stance phase for the ipsilateral limb to the initial stance phase for the contralateral limb. These results suggest that novel metrics for accelerometry gait analysis can reveal gait abnormalities, with restricted knee extension corresponding to the gait cycle.
- 8 July 2021
- Published by Hindawi Limited in Rehabilitation Research and Practice
- Vol. 2021, 1-7
Open AccessImmediate Effect of Restricted Knee Extension on Ground Reaction Force and Trunk Acceleration during Walking
Gait parameters calculated from trunk acceleration reflect the features of gait; however, they cannot evaluate the gait pattern corresponding to the gait cycle. This study is aimed at investigating the differences in gait parameters calculated from trunk acceleration during gait corresponding to the gait cycle in healthy subjects with restricted knee extension. Participants included eight healthy volunteers who walked normally (NW) and with knee orthosis that restricted knee extension (ER). The ground reaction force (GRF), joint angles, and trunk acceleration during walking were measured using four force plates, a three-dimensional motion analysis system, and an inertial measurement unit. The peak GRF of the vertical components, joint ranges of motion, and moments of force were analyzed. The root mean square (RMS) and amplitude peak ratio (AR) of autocorrelation function were calculated from the trunk acceleration waveform. The first peak GRF and peak ankle dorsiflexion angles significantly increased during ER. The peak hip extension, knee flexion, knee extension angles, and the peak moment of knee extension significantly decreased during ER compared to that during NW. The acceleration AR significantly decreased during ER compared to that during NW. There was no significant difference in the RMS between the two conditions. The acceleration AR may show the temporal postural structure with restricted knee extension from the terminal stance phase for the ipsilateral limb to the initial stance phase for the contralateral limb. These results suggest that novel metrics for accelerometry gait analysis can reveal gait abnormalities, with restricted knee extension corresponding to the gait cycle.
- 18 June 2020
- Published by Taylor & Francis in Disability and Rehabilitation: Assistive Technology
- Vol. 17 (3) , 304-309
An investigation into the effectiveness of a novel wheelchair seat-cover assembly for the reduction of forces exerted onto the buttocks
Purpose: This purpose was to investigate developed seat-cover assemblies’ effect on decreasing the fluctuation of the shear force exerted onto the buttocks as the factors causing decubitus ulcers when the back-support was inclined. Materials and Methods: The participants were 10 wheelchair users. The force plate was used to measure the horizontal force as the shear force. The back-support was inclined at increasing angles, starting from the upright position (IUP), then proceeding to a fully reclined position (FRP), and returning to the upright position (RUP). The experimental conditions were two conditions; the seat-cover assembly conditions and without the seat-cover assembly as the control conditions. Results: The average values in the seat-cover assembly condition were 14.4 ± 3.3, 13.9 ± 2.3, and 17.3 ± 3.3% body weight in the IUP, FRP, and RUP, respectively. The average values in the control condition were 14.8 ± 2.6, 11.4 ± 1.7, and 24.0 ± 6.7% body weight in the IUP, FRP, and RUP, respectively. In the FUP and the RUP, there were significant differences between two conditions (p < .01). Conclusion: These results suggested that the shear force exerted onto the buttocks may to be decreased by using novel seat-cover assembly.
- 18 June 2020
- Published by Taylor & Francis in Disability and Rehabilitation: Assistive Technology
- Vol. 17 (3) , 304-309
An investigation into the effectiveness of a novel wheelchair seat-cover assembly for the reduction of forces exerted onto the buttocks
Purpose: This purpose was to investigate developed seat-cover assemblies’ effect on decreasing the fluctuation of the shear force exerted onto the buttocks as the factors causing decubitus ulcers when the back-support was inclined. Materials and Methods: The participants were 10 wheelchair users. The force plate was used to measure the horizontal force as the shear force. The back-support was inclined at increasing angles, starting from the upright position (IUP), then proceeding to a fully reclined position (FRP), and returning to the upright position (RUP). The experimental conditions were two conditions; the seat-cover assembly conditions and without the seat-cover assembly as the control conditions. Results: The average values in the seat-cover assembly condition were 14.4 ± 3.3, 13.9 ± 2.3, and 17.3 ± 3.3% body weight in the IUP, FRP, and RUP, respectively. The average values in the control condition were 14.8 ± 2.6, 11.4 ± 1.7, and 24.0 ± 6.7% body weight in the IUP, FRP, and RUP, respectively. In the FUP and the RUP, there were significant differences between two conditions (p < .01). Conclusion: These results suggested that the shear force exerted onto the buttocks may to be decreased by using novel seat-cover assembly.
- Open Access
- 14 September 2018
- Published by Taylor & Francis in Cogent Psychology
- Vol. 5 (1)
Effects of action observation on learning non-weight-bearing gait with crutches
Action observation (AO) has been used to improve rehabilitation outcomes. We examined the effects of AO gait training on the acquisition of a non-weight-bearing (NWB) gait with crutches. Eighteen healthy young male participants were assigned to control (n=9) and AO groups (n=9). All subjects were instructed to walk with crutches at a comfortable speed on a 10-m walkway (10 trials). Participants received a verbal explanation of the experimental task (NWB gait with crutches), after which, those in the AO group watched a video of another person performing the task. An accelerometer was positioned on the third lumbar vertebra and used to measure the trunk acceleration during the experimental task. Gait speed and acceleration root mean squares (RMS) were calculated during the 1st, 5th, and 10th trials for each group. The two-way ANOVA for acceleration RMS revealed significant main effects of trial and group, as well as a significant trial by group interaction. During the first trial, fewer trunk fluctuations were observed in the AO group compared to that in the control group. Thus, AO is effective in improving NWB gait training with crutches during the early phase of acquisition.
- 14 September 2018
- Published by Taylor & Francis in Cogent Psychology
- Vol. 5 (1)
Open AccessEffects of action observation on learning non-weight-bearing gait with crutches
Action observation (AO) has been used to improve rehabilitation outcomes. We examined the effects of AO gait training on the acquisition of a non-weight-bearing (NWB) gait with crutches. Eighteen healthy young male participants were assigned to control (n=9) and AO groups (n=9). All subjects were instructed to walk with crutches at a comfortable speed on a 10-m walkway (10 trials). Participants received a verbal explanation of the experimental task (NWB gait with crutches), after which, those in the AO group watched a video of another person performing the task. An accelerometer was positioned on the third lumbar vertebra and used to measure the trunk acceleration during the experimental task. Gait speed and acceleration root mean squares (RMS) were calculated during the 1st, 5th, and 10th trials for each group. The two-way ANOVA for acceleration RMS revealed significant main effects of trial and group, as well as a significant trial by group interaction. During the first trial, fewer trunk fluctuations were observed in the AO group compared to that in the control group. Thus, AO is effective in improving NWB gait training with crutches during the early phase of acquisition.
- 1 October 2015
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 39 (5) , 397-404
Influence of rotational axis height of back support on horizontal force applied to buttocks in a reclining wheelchair
Studies have not been conducted to investigate the influence of the height of the rotational axis of a wheelchair’s back support on the shear force applied to the buttocks during the reclining motion. The purpose of this study was to investigate the influence of the difference in the rotational axis position of back support in the vertical direction on the horizontal force applied to buttocks for preventing decubitus ulcers. Repeated measures design. The subjects were 13 healthy adult men without leg and/or trunk diseases. The shear force was measured using a force plate. A comfortable sitting posture in the experimental chair was selected for measurement. The rotational axis was positioned 13 cm forward on the horizontal plane from the intersection between the seat and the back support. The axis positions on the vertical plane as two experimental conditions were the seat height and the 7.5-cm upward from the seat height which was nearer to the hip joint. In returning the back support to an upright position, the horizontal force was 12.4 ± 1.6 (percent body weight) under the seat height-axis condition and 10.1 ± 1.8 (percent body weight) under the upward-axis condition (p < 0.01). This result suggested that the wheelchair might have to be capable of adjusting the height of the rotational axis of the back support to reduce the horizontal force applied to buttocks. This study shows one of the suggestions regarding seating approach for the prevention of decubitus ulcers. There is a possibility of reducing horizontal force applied to buttocks after reclined back support, by adjusting the height of the rotational axis position of wheelchair back support.
- 1 October 2015
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 39 (5) , 397-404
Influence of rotational axis height of back support on horizontal force applied to buttocks in a reclining wheelchair
Studies have not been conducted to investigate the influence of the height of the rotational axis of a wheelchair’s back support on the shear force applied to the buttocks during the reclining motion. The purpose of this study was to investigate the influence of the difference in the rotational axis position of back support in the vertical direction on the horizontal force applied to buttocks for preventing decubitus ulcers. Repeated measures design. The subjects were 13 healthy adult men without leg and/or trunk diseases. The shear force was measured using a force plate. A comfortable sitting posture in the experimental chair was selected for measurement. The rotational axis was positioned 13 cm forward on the horizontal plane from the intersection between the seat and the back support. The axis positions on the vertical plane as two experimental conditions were the seat height and the 7.5-cm upward from the seat height which was nearer to the hip joint. In returning the back support to an upright position, the horizontal force was 12.4 ± 1.6 (percent body weight) under the seat height-axis condition and 10.1 ± 1.8 (percent body weight) under the upward-axis condition (p < 0.01). This result suggested that the wheelchair might have to be capable of adjusting the height of the rotational axis of the back support to reduce the horizontal force applied to buttocks. This study shows one of the suggestions regarding seating approach for the prevention of decubitus ulcers. There is a possibility of reducing horizontal force applied to buttocks after reclined back support, by adjusting the height of the rotational axis position of wheelchair back support.