Zhenqin Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhenqin Chen has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Jinshan Xu
Zhejiang University of Technology
11 shared publications - Yiwei Lin
College of Computer Science, Zhejiang University of Technology, Hangzhou, China
7 shared publications - Fengdan Hu
Zhejiang Shuren University, Hangzhou 310015, China
2 shared publications - Hai Yu
State Key Laboratory of Vaccines for Infectious Diseases, Xiang An Biomedicine Laboratory, School of Public Health, School of Life Sciences, Xiamen University, Xiamen, China
2 shared publications Jinle Han
Beijing Wantai Enterprise Community Partners, Beijing 102206, China
2 shared publicationsJinpeng Zhang
College of Computer Science, Zhejiang University of Technology, Hangzhou, China
2 shared publications
Latest Publications
- 7 October 2026
- Published by Elsevier in Expert Systems with Applications
- Vol. 334
Robust and interpretable ECG denoising via stage-aware conditional diffusion with co-evolving guidance
- 7 October 2026
- Published by Elsevier in Expert Systems with Applications
- Vol. 334
Robust and interpretable ECG denoising via stage-aware conditional diffusion with co-evolving guidance
- 14 July 2026
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 180, 103485
GLF-Net: A quasi-periodic prior-guided waveform segmentation network for ECG delineation
- 14 July 2026
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 180, 103485
GLF-Net: A quasi-periodic prior-guided waveform segmentation network for ECG delineation
- 7 April 2026
- Published by Elsevier in Expert Systems with Applications
- Vol. 322
FM-FECG: An observation-informed flow matching framework for non-invasive fetal ECG extraction
- 7 April 2026
- Published by Elsevier in Expert Systems with Applications
- Vol. 322
FM-FECG: An observation-informed flow matching framework for non-invasive fetal ECG extraction
- 10 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Artificial Intelligence
- Vol. 7 (1) , 534-546
DIFF-FECG: A Conditional Diffusion-Based Method for Fetal ECG Extraction From Abdominal ECG
Fetal electrocardiography (FECG) is a crucial tool for assessing fetal cardiac health and pregnancy status. Direct invasive FECG provides reliable fetal heart rate signals, but poses risks and is limited to use during labor. Conversely, non-invasive monitoring of the fetal heart is possible via abdominal electrocardiography (AECG), which detects fetal heart waveforms using electrodes positioned on the mother’s abdomen. However, this method is often subject to interference from maternal cardiac activity and other external sources. To address this issue, we propose a novel diffusion method, DIFF-FECG, aimed at improving the extraction of FECG signals from AECG recordings. This method leverages a condition-driven diffusion process to learn specific conditional probability distributions, enabling the effective separation of high-quality FECG signals from noisy AECG data. By adaptively managing the inherent non-Gaussian noise characteristics of MECG within the AECG, DIFF-FECG achieves more effective FECG reconstruction. Furthermore, the quality of the generated FECG signals is also enhanced by adding reconstruction loss and multiple reconstructions. Experimental results on two public databases demonstrate that the proposed DIFF-FECG method yields satisfactory results, with an average Pearson correlation coefficient of 0.922 for the estimated FECG. These findings underscore the potential of diffusion probabilistic models in advancing FECG signal extraction techniques, thereby contributing to improved fetal health monitoring.
- 10 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Artificial Intelligence
- Vol. 7 (1) , 534-546
DIFF-FECG: A Conditional Diffusion-Based Method for Fetal ECG Extraction From Abdominal ECG
Fetal electrocardiography (FECG) is a crucial tool for assessing fetal cardiac health and pregnancy status. Direct invasive FECG provides reliable fetal heart rate signals, but poses risks and is limited to use during labor. Conversely, non-invasive monitoring of the fetal heart is possible via abdominal electrocardiography (AECG), which detects fetal heart waveforms using electrodes positioned on the mother’s abdomen. However, this method is often subject to interference from maternal cardiac activity and other external sources. To address this issue, we propose a novel diffusion method, DIFF-FECG, aimed at improving the extraction of FECG signals from AECG recordings. This method leverages a condition-driven diffusion process to learn specific conditional probability distributions, enabling the effective separation of high-quality FECG signals from noisy AECG data. By adaptively managing the inherent non-Gaussian noise characteristics of MECG within the AECG, DIFF-FECG achieves more effective FECG reconstruction. Furthermore, the quality of the generated FECG signals is also enhanced by adding reconstruction loss and multiple reconstructions. Experimental results on two public databases demonstrate that the proposed DIFF-FECG method yields satisfactory results, with an average Pearson correlation coefficient of 0.922 for the estimated FECG. These findings underscore the potential of diffusion probabilistic models in advancing FECG signal extraction techniques, thereby contributing to improved fetal health monitoring.
- 13 December 2023
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 90
Automatic detection and characterization of uterine contraction using Electrohysterography
- 13 December 2023
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 90
Automatic detection and characterization of uterine contraction using Electrohysterography
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Sample Point Classification of Abdominal ECG Through CNN-Transformer Model Enables Efficient Fetal Heart Rate Detection
Monitoring fetal heart rate (FHR) is essential for the early detection of fetal distress and ensuring safe delivery. Direct invasive fetal electrocardiography (FECG) provides reliable FHR signals but is limited to use during labor. Noninvasive fetal heart monitoring can be achieved through abdominal electrocardiography (AECG), where fetal heartbeat waveforms are captured from electrodes placed on maternal abdomen. However, accurately locating fetal R-peaks and obtaining FHRs remain challenging due to interference from uterine contractions and maternal heartbeats. To address this challenge, we proposed an end-to-end fetal R-peak detection method based on sample point classification. Inspired by semantic segmentation in image analysis, we utilized an encoder-decoder model to classify each point in the 1-D AECG signal. The model captures the global contextual information of fetal heartbeat waveforms by combining convolutional neural networks (CNNs) and transformer, resulting in a high-precision classification of each sample point in the AECG signal. Moreover, to mitigate the impact of misclassified points on fetal R-peak detection, we proposed a postprocessing method based on the periodicity of heartbeats. The effectiveness of the proposed method is validated on two AECG databases, achieving satisfactory results with an average F1-score of 98.91%. These findings demonstrate the potential application of long-term fetal monitoring using portable devices. The code is publicly available at https://github.com/ZJUT-CBS/FR-Net .
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Sample Point Classification of Abdominal ECG Through CNN-Transformer Model Enables Efficient Fetal Heart Rate Detection
Monitoring fetal heart rate (FHR) is essential for the early detection of fetal distress and ensuring safe delivery. Direct invasive fetal electrocardiography (FECG) provides reliable FHR signals but is limited to use during labor. Noninvasive fetal heart monitoring can be achieved through abdominal electrocardiography (AECG), where fetal heartbeat waveforms are captured from electrodes placed on maternal abdomen. However, accurately locating fetal R-peaks and obtaining FHRs remain challenging due to interference from uterine contractions and maternal heartbeats. To address this challenge, we proposed an end-to-end fetal R-peak detection method based on sample point classification. Inspired by semantic segmentation in image analysis, we utilized an encoder-decoder model to classify each point in the 1-D AECG signal. The model captures the global contextual information of fetal heartbeat waveforms by combining convolutional neural networks (CNNs) and transformer, resulting in a high-precision classification of each sample point in the AECG signal. Moreover, to mitigate the impact of misclassified points on fetal R-peak detection, we proposed a postprocessing method based on the periodicity of heartbeats. The effectiveness of the proposed method is validated on two AECG databases, achieving satisfactory results with an average F1-score of 98.91%. These findings demonstrate the potential application of long-term fetal monitoring using portable devices. The code is publicly available at https://github.com/ZJUT-CBS/FR-Net .
- 30 August 2022
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 79
Post-processing refined ECG delineation based on 1D-UNet
- 30 August 2022
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 79
Post-processing refined ECG delineation based on 1D-UNet
- 5 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (7) , 2876-2887
Network Theory Based EHG Signal Analysis and its Application in Preterm Prediction
Objective: Preterm birth is the leading cause of neonatal morbidity and mortality. Early identification of high-risk patients followed by medical interventions is essential to the prevention of preterm birth. Based on the relationship between uterine contraction and the fundamental electrical activities of muscles, we extracted effective features from EHG signals recorded from pregnant women, and use them to train classifiers with the purpose of providing high precision in classifying term and preterm pregnancies. Methods: To characterize changes from irregularity to coherence of the uterine activity during the whole pregnancy, network representations of the original electrohysterogram (EHG) signals are established by applying the Horizontal Visibility Graph (HVG) algorithm, from which we extract network degree density and distribution, clustering coefficient and assortativity coefficient. Concerns on the interferences of different noise sources embedded in the EHG signal, we apply Short-Time Fourier Transform (STFT) to expand the original signal in the time-frequency domain. This allows a network representation and the extraction of related features on each frequency component. Feature selection algorithms are then used to filter out unrelated frequency components. We further apply the proposed feature extraction method to EHG signals available in the Term-Preterm EHG database (TPEHG), and use them to train classifiers. We adopt the Partition-Synthesis scheme which splits the original imbalanced dataset into two sets, and synthesizes artificial samples separately within each subset to solve the problem of dataset imbalance. Results: The optimally selected network-based features, not only contribute to the identification of the essential frequency components of uterine activities related to preterm birth, but also to improved performance in classifying term/preterm pregnancies, i.e., the SVM (Support Vector Machine) classifier trained with the available samples in the TPEHG gives sensitivity, specificity, overall accuracy, and $auc$ values as high as 0.89, 0.93, 0.91, and 0.97, respectively.
- 5 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (7) , 2876-2887
Network Theory Based EHG Signal Analysis and its Application in Preterm Prediction
Objective: Preterm birth is the leading cause of neonatal morbidity and mortality. Early identification of high-risk patients followed by medical interventions is essential to the prevention of preterm birth. Based on the relationship between uterine contraction and the fundamental electrical activities of muscles, we extracted effective features from EHG signals recorded from pregnant women, and use them to train classifiers with the purpose of providing high precision in classifying term and preterm pregnancies. Methods: To characterize changes from irregularity to coherence of the uterine activity during the whole pregnancy, network representations of the original electrohysterogram (EHG) signals are established by applying the Horizontal Visibility Graph (HVG) algorithm, from which we extract network degree density and distribution, clustering coefficient and assortativity coefficient. Concerns on the interferences of different noise sources embedded in the EHG signal, we apply Short-Time Fourier Transform (STFT) to expand the original signal in the time-frequency domain. This allows a network representation and the extraction of related features on each frequency component. Feature selection algorithms are then used to filter out unrelated frequency components. We further apply the proposed feature extraction method to EHG signals available in the Term-Preterm EHG database (TPEHG), and use them to train classifiers. We adopt the Partition-Synthesis scheme which splits the original imbalanced dataset into two sets, and synthesizes artificial samples separately within each subset to solve the problem of dataset imbalance. Results: The optimally selected network-based features, not only contribute to the identification of the essential frequency components of uterine activities related to preterm birth, but also to improved performance in classifying term/preterm pregnancies, i.e., the SVM (Support Vector Machine) classifier trained with the available samples in the TPEHG gives sensitivity, specificity, overall accuracy, and $auc$ values as high as 0.89, 0.93, 0.91, and 0.97, respectively.