Efe Ozkaya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Efe Ozkaya has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Bachir Taouli
Icahn School of Medicine at Mount Sinai
2 shared publications - Emily Triolo
Program in Advanced Imaging Research, Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, United States
2 shared publications - Jun Ueda
Georgia Institute of Technology
2 shared publications - Lazar Fleysher
Icahn School of Medicine at Mount Sinai
2 shared publications - Mehmet Kurt
University of Washington
2 shared publications - Paul Kennedy
Biomedical Engineering and Imaging Institute Icahn School of Medicine at Mount Sinai New York New York USA
2 shared publications
Latest Publications
- Top Cited Papers
- 1 March 2026
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 318 (3) , e252094
The Rise of Deepfake Medical Imaging: Radiologists’ Diagnostic Accuracy in Detecting ChatGPT-generated Radiographs
Synthetic radiographs, including OpenAI’s ChatGPT-generated ones, are not easily distinguishable from authentic radiographs by either radiologists or large language models; physician training and dedicated tools are crucial to mitigate risks.
- 1 March 2026
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 318 (3) , e252094
Top Cited PapersThe Rise of Deepfake Medical Imaging: Radiologists’ Diagnostic Accuracy in Detecting ChatGPT-generated Radiographs
Synthetic radiographs, including OpenAI’s ChatGPT-generated ones, are not easily distinguishable from authentic radiographs by either radiologists or large language models; physician training and dedicated tools are crucial to mitigate risks.
- 1 May 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 311 (2) , e233136
Precision and Test-Retest Repeatability of Stiffness Measurement with MR Elastography: A Multicenter Phantom Study
MR elastography demonstrated excellent stiffness measurement precision and test-retest repeatability across five study centers, 10 scanners, three manufacturers, two field strengths, two MR elastography sequences, and three phantoms mimicking different degrees of liver stiffness.
- 1 May 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 311 (2) , e233136
Precision and Test-Retest Repeatability of Stiffness Measurement with MR Elastography: A Multicenter Phantom Study
MR elastography demonstrated excellent stiffness measurement precision and test-retest repeatability across five study centers, 10 scanners, three manufacturers, two field strengths, two MR elastography sequences, and three phantoms mimicking different degrees of liver stiffness.
- 19 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (11) , 3345-3355
Towards Image Guided Magnetic Resonance Elastography via Active Driver Positioning Robot
Magnetic Resonance Elastography (MRE) is a developing imaging technique that enables non-invasive estimation of tissue mechanical properties through the combination of induced mechanical displacements in the tissue and Magnetic Resonance Imaging (MRI). The mechanical drivers necessary to produce shear waves in the tissue have been a focus of engineering effort in the development and refinement of MRE. The potential targeting of smaller and stiffer tissues calls for increases in actuation frequency and refinement of mechanical driver positioning. Furthermore, the anisotropic nature of soft tissues results in driver position related changes in observed displacement wave patterns. These challenges motivate the investigation and development of the concept of active MRE driver positioning through visual servoing under MR imaging. Objective: This work demonstrates the initial prototype of an MRE driver positioning system, allowing capture of displacement wave patterns from various mechanical vibration loading angles under different vibration frequencies through MR imaging. Methods: Three different configurations of the MRE driver positioning robot are tested with an intervertebral disc (IVD) shaped gel phantom. Results: Both the octahedral shear stress signal to noise ratio (OSS-SNR) and estimated stiffness show statistically significant dependence on driver configuration in each of the three phantom IVD regions. Conclusion: This dependence demonstrates that driver configuration is a critical factor in MRE, and that the developed robot is capable of producing a range of configurations. Significance: This work presents the first demonstration of an active, imaging guided MRE driver positioning system, with significance for the future application of MRE to a wider range of human tissues.
- 19 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (11) , 3345-3355
Towards Image Guided Magnetic Resonance Elastography via Active Driver Positioning Robot
Magnetic Resonance Elastography (MRE) is a developing imaging technique that enables non-invasive estimation of tissue mechanical properties through the combination of induced mechanical displacements in the tissue and Magnetic Resonance Imaging (MRI). The mechanical drivers necessary to produce shear waves in the tissue have been a focus of engineering effort in the development and refinement of MRE. The potential targeting of smaller and stiffer tissues calls for increases in actuation frequency and refinement of mechanical driver positioning. Furthermore, the anisotropic nature of soft tissues results in driver position related changes in observed displacement wave patterns. These challenges motivate the investigation and development of the concept of active MRE driver positioning through visual servoing under MR imaging. Objective: This work demonstrates the initial prototype of an MRE driver positioning system, allowing capture of displacement wave patterns from various mechanical vibration loading angles under different vibration frequencies through MR imaging. Methods: Three different configurations of the MRE driver positioning robot are tested with an intervertebral disc (IVD) shaped gel phantom. Results: Both the octahedral shear stress signal to noise ratio (OSS-SNR) and estimated stiffness show statistically significant dependence on driver configuration in each of the three phantom IVD regions. Conclusion: This dependence demonstrates that driver configuration is a critical factor in MRE, and that the developed robot is capable of producing a range of configurations. Significance: This work presents the first demonstration of an active, imaging guided MRE driver positioning system, with significance for the future application of MRE to a wider range of human tissues.
- 1 October 2021
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 122, 104680
Brain-mimicking phantom for biomechanical validation of motion sensitive MR imaging techniques
- 1 October 2021
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 122, 104680
Brain-mimicking phantom for biomechanical validation of motion sensitive MR imaging techniques