Jae Won Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jae Won Lee has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Yong Tae Kang
12 shared publicationsSeonggon Kim
6 shared publicationsRonghuan Xu
4 shared publications- Bora Kim
Department of Mechanical Engineering, Korea Maritime & Ocean University, Busan, South Korea
3 shared publications - Hyungseop Ahn
Korea University
3 shared publications Jong Ha Park
2 shared publications
Latest Publications
- 26 April 2026
- Published by Elsevier in Energy Conversion and Management
- Vol. 359
Sorption-assisted thermal management and CO2 capture in LED heat sinks via MWCNT/PEI functional coatings
- 26 April 2026
- Published by Elsevier in Energy Conversion and Management
- Vol. 359
Sorption-assisted thermal management and CO2 capture in LED heat sinks via MWCNT/PEI functional coatings
- Open Access
- 20 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 53
Low-Temperature Regenerable Water-Loaded Zeolite 13X for Ammonia Capture, Reusability, and Leak Detection in Confined Space
Ammonia is a carbon-free energy carrier and a natural refrigerant with a high energy density. However, its high toxicity raises significant safety concerns in confined environments. To address this issue, this study developed a hybrid ammonia capture material, water-loaded zeolite 13X (WLZ), which combines the structural stability of zeolites with a strong chemical affinity for water. WLZ was synthesized using an ethanol-water impregnation method. A series of experiments were conducted under simulated leak conditions in pure ammonia and air. WLZ-75, containing 75% water loading, demonstrated high ammonia capture efficiency (over 90% removal at 1000 ppm), stable low-temperature regeneration below 90 °C over repeated cycles, and more than 95% retention after 10 capture/regeneration cycles. Chamber-scale tests confirmed not only its high removal performance but also exothermic behavior, potentially enabling thermal-based leak detection. These results demonstrate that WLZ is a highly regenerable and thermally responsive material suitable for ammonia safety management in refrigeration, fuel systems, and sealed environments.
- 20 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 53
Open AccessLow-Temperature Regenerable Water-Loaded Zeolite 13X for Ammonia Capture, Reusability, and Leak Detection in Confined Space
Ammonia is a carbon-free energy carrier and a natural refrigerant with a high energy density. However, its high toxicity raises significant safety concerns in confined environments. To address this issue, this study developed a hybrid ammonia capture material, water-loaded zeolite 13X (WLZ), which combines the structural stability of zeolites with a strong chemical affinity for water. WLZ was synthesized using an ethanol-water impregnation method. A series of experiments were conducted under simulated leak conditions in pure ammonia and air. WLZ-75, containing 75% water loading, demonstrated high ammonia capture efficiency (over 90% removal at 1000 ppm), stable low-temperature regeneration below 90 °C over repeated cycles, and more than 95% retention after 10 capture/regeneration cycles. Chamber-scale tests confirmed not only its high removal performance but also exothermic behavior, potentially enabling thermal-based leak detection. These results demonstrate that WLZ is a highly regenerable and thermally responsive material suitable for ammonia safety management in refrigeration, fuel systems, and sealed environments.
- Open Access
- 3 December 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (23) , 10838
Proximal Monitoring of CO2 Dynamics in Indoor Smart Farming: A Deep Learning and Image-Sensor Fusion Approach
In controlled environment agriculture (CEA), CO2 enrichment can promote photosynthesis while simultaneously reducing evapotranspiration, but the optimal settings vary depending on crop type, growth stage, and microclimate. This study presents a near-field remote sensing framework that fuses RGB image features with environmental variables to predict the CO2 uptake/respiration dynamics of five leafy vegetables grown in a hydroponic culture system and evaluate their impact on resource efficiency under CO2 control. A hybrid deep model incorporating You Only Look Once version 11 (YOLOv11) and a Residual Network with 50 layers (ResNet50) extracts growth-related visual cues and integrates them with tabular features (CO2, temperature, and light conditions) to predict chamber CO2 dynamics. Performance was evaluated by Mean Absolute Error (MAE)/Mean Squared Error (MSE) on withheld data, and the system-level impacts on water use (ET), pumping energy, and relative yield were analyzed using a conventional greenhouse model. The model exhibited high accuracy (MAE = 0.95; MSE = 1.62). Scenario analysis results showed that increasing ambient CO2 concentration from 400 to 1200 ppm reduced modeled water demand by approximately 11%, increased modeled yield by approximately 9%, and resulted in a corresponding reduction in pumping energy per unit area. Unlike conventional single-crop, table-based approaches, this study demonstrates multi-crop generalization and image-environment fusion for CO2 dynamic prediction, establishing proximity sensing as a viable decision-making layer for CEA. While yield/ET results were simulated rather than measured in long-term trials, and leaf area normalization was not available, the proposed framework provides a viable path for data-driven CO2 control in indoor farms by linking image-based monitoring with operational optimization.
- 3 December 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (23) , 10838
Open AccessProximal Monitoring of CO2 Dynamics in Indoor Smart Farming: A Deep Learning and Image-Sensor Fusion Approach
In controlled environment agriculture (CEA), CO2 enrichment can promote photosynthesis while simultaneously reducing evapotranspiration, but the optimal settings vary depending on crop type, growth stage, and microclimate. This study presents a near-field remote sensing framework that fuses RGB image features with environmental variables to predict the CO2 uptake/respiration dynamics of five leafy vegetables grown in a hydroponic culture system and evaluate their impact on resource efficiency under CO2 control. A hybrid deep model incorporating You Only Look Once version 11 (YOLOv11) and a Residual Network with 50 layers (ResNet50) extracts growth-related visual cues and integrates them with tabular features (CO2, temperature, and light conditions) to predict chamber CO2 dynamics. Performance was evaluated by Mean Absolute Error (MAE)/Mean Squared Error (MSE) on withheld data, and the system-level impacts on water use (ET), pumping energy, and relative yield were analyzed using a conventional greenhouse model. The model exhibited high accuracy (MAE = 0.95; MSE = 1.62). Scenario analysis results showed that increasing ambient CO2 concentration from 400 to 1200 ppm reduced modeled water demand by approximately 11%, increased modeled yield by approximately 9%, and resulted in a corresponding reduction in pumping energy per unit area. Unlike conventional single-crop, table-based approaches, this study demonstrates multi-crop generalization and image-environment fusion for CO2 dynamic prediction, establishing proximity sensing as a viable decision-making layer for CEA. While yield/ET results were simulated rather than measured in long-term trials, and leaf area normalization was not available, the proposed framework provides a viable path for data-driven CO2 control in indoor farms by linking image-based monitoring with operational optimization.
- Open Access
- 5 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (21) , 11805
Evaluating the Energy and Thermal Performance of a Water-Cooled Condenser Using Reverse Osmosis Effluent in Residential Purifiers
Reverse osmosis (RO) water purifiers produce a large volume of reject water, which is typically discarded, leading to water wastage and resource inefficiency. This work proposes a novel approach to reusing RO effluent as a cooling medium in a water-cooled condenser integrated into a residential hot-and-cold water purifier. The system replaces a conventional air-cooled condenser with a water-cooled unit and was evaluated under controlled laboratory conditions (ambient temperature 25 °C). Experiments were conducted at various RO effluent flow rates ranging from 0.5 to 2.5 L per minute (LPM). Key performance metrics, including the coefficient of performance (COP), cooling time, and energy consumption, were measured and compared. Results showed that replacing a conventional air-cooled condenser with a water-cooled condenser configuration reduces energy consumption by up to 37.5% and shortens cooling times by up to 33%. Performance was maintained under intermittent RO effluent supply. However, an excessive flow rate (2.0 LPM) caused evaporator frosting and efficiency loss, indicating the importance of flow control. These findings demonstrate that internally reusing an RO effluent offers a sustainable, compact, and energy-efficient solution for next-generation water purifiers.
- 5 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (21) , 11805
Open AccessEvaluating the Energy and Thermal Performance of a Water-Cooled Condenser Using Reverse Osmosis Effluent in Residential Purifiers
Reverse osmosis (RO) water purifiers produce a large volume of reject water, which is typically discarded, leading to water wastage and resource inefficiency. This work proposes a novel approach to reusing RO effluent as a cooling medium in a water-cooled condenser integrated into a residential hot-and-cold water purifier. The system replaces a conventional air-cooled condenser with a water-cooled unit and was evaluated under controlled laboratory conditions (ambient temperature 25 °C). Experiments were conducted at various RO effluent flow rates ranging from 0.5 to 2.5 L per minute (LPM). Key performance metrics, including the coefficient of performance (COP), cooling time, and energy consumption, were measured and compared. Results showed that replacing a conventional air-cooled condenser with a water-cooled condenser configuration reduces energy consumption by up to 37.5% and shortens cooling times by up to 33%. Performance was maintained under intermittent RO effluent supply. However, an excessive flow rate (2.0 LPM) caused evaporator frosting and efficiency loss, indicating the importance of flow control. These findings demonstrate that internally reusing an RO effluent offers a sustainable, compact, and energy-efficient solution for next-generation water purifiers.
- Open Access
- 20 October 2023
- Published by Elsevier in Journal of CO2 Utilization
- Vol. 77
Structural modified metal-organic frameworks by hierarchical layer-by-layer method for efficient CO2 capture enhancement
- 20 October 2023
- Published by Elsevier in Journal of CO2 Utilization
- Vol. 77
Open AccessStructural modified metal-organic frameworks by hierarchical layer-by-layer method for efficient CO2 capture enhancement
- 25 September 2023
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 187
Progress in CO2 hydrate formation and feasibility analysis for cold thermal energy harvesting application
- 25 September 2023
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 187
Progress in CO2 hydrate formation and feasibility analysis for cold thermal energy harvesting application