Vincenzo Guidi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Vincenzo Guidi has a total of 124 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Mazzolari
INFN Sezione di Ferrara
7 shared publications - Barbara Fabbri
Department of Physics and Earth Sciences, University of Ferrara, Via Saragat 1, Ferrara 44122, Italy
7 shared publications - Laura Bandiera
INFN, Sezione di Ferrara
7 shared publications - Lorenzo Malagutti
INFN Sezione di Ferrara
7 shared publications - Marco Romagnoni
INFN Sezione di Ferrara
7 shared publications - Matteo Valt
Sensors and Devices Center, Bruno Kessler Foundation, Via Sommarive 18, 38123 Trento, Italy
7 shared publications
Latest Publications
- Open Access
- 6 November 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 114 (9)
Background of the BULLKID detector array operated with a moderate shield on the surface
We present the operation with moderate radiation shield in a surface laboratory of BULky and Low-threshold Kinetic Inductance Detector) (BULLKID), a cryogenic detector for searches of light dark matter or coherent elastic neutrino-nucleus scattering. The detector consists of an array of 60 cubic silicon particle absorbers of 0.34 g each, sensed by cryogenic kinetic inductance detectors. The analysis presented focuses on data from 15 elements of the array, with two central units used to evaluate the background and with their surrounding elements used as veto. The low energy spectrum resulting from an exposure of 290 hours to ambient backgrounds, acquired with the use of external and internal radiation shields, is compatible with the simulations at the level of ( 6.8 ± 0.4 stat . ± 0.1 syst . ) × 10 4 counts / keV kg days from 2 keV down to an energy of 600 eV. The region between 225 eV and 600 eV shows a rise in background in disagreement with the simulations, while not sharing some of the key traits of the low energy excess observed in other cryogenic experiments. The high energy spectrum shape is in overall agreement with the simulations and displays the typical particle-induced x-ray emission of the surrounding lead.
- 6 November 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 114 (9)
Open AccessBackground of the BULLKID detector array operated with a moderate shield on the surface
We present the operation with moderate radiation shield in a surface laboratory of BULky and Low-threshold Kinetic Inductance Detector) (BULLKID), a cryogenic detector for searches of light dark matter or coherent elastic neutrino-nucleus scattering. The detector consists of an array of 60 cubic silicon particle absorbers of 0.34 g each, sensed by cryogenic kinetic inductance detectors. The analysis presented focuses on data from 15 elements of the array, with two central units used to evaluate the background and with their surrounding elements used as veto. The low energy spectrum resulting from an exposure of 290 hours to ambient backgrounds, acquired with the use of external and internal radiation shields, is compatible with the simulations at the level of ( 6.8 ± 0.4 stat . ± 0.1 syst . ) × 10 4 counts / keV kg days from 2 keV down to an energy of 600 eV. The region between 225 eV and 600 eV shows a rise in background in disagreement with the simulations, while not sharing some of the key traits of the low energy excess observed in other cryogenic experiments. The high energy spectrum shape is in overall agreement with the simulations and displays the typical particle-induced x-ray emission of the surrounding lead.
- Open Access
- 23 March 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (3)
Energy calibration of bulk events in the BULLKID detector
BULLKID is a cryogenic, solid-state detector designed for direct searches of particle Dark Matter candidates, with mass $$\lesssim 1$$ GeV/c $$^2$$ , and coherent neutrino-nucleus scattering. It is based on an array of dice carved in 5 mm thick silicon crystal, sensed by phonon-mediated Kinetic Inductance Detectors. In previous works, the array was calibrated with bursts of optical photons, which are absorbed in the first hundreds nanometers of the dice and give rise to surface events. In this work, we present the reconstruction of bulk events through the 59.5 keV $$\gamma $$ -ray generated by an $$^{241}$$ Am source, which emulates more closely the interaction of Dark Matter and neutrinos. The peak resolution is $$5\%~(\sigma )$$ and its position is shifted by less than $$10\%$$ with respect to the optical calibration. We observe that the resolution is further improved by a factor 2 combining the signal from neighboring dice. These results confirm the performance of the detector in view of the physics goals of the BULLKID-DM experiment for dark matter search.- 23 March 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (3)
Open AccessEnergy calibration of bulk events in the BULLKID detector
BULLKID is a cryogenic, solid-state detector designed for direct searches of particle Dark Matter candidates, with mass $$\lesssim 1$$ GeV/c $$^2$$ , and coherent neutrino-nucleus scattering. It is based on an array of dice carved in 5 mm thick silicon crystal, sensed by phonon-mediated Kinetic Inductance Detectors. In previous works, the array was calibrated with bursts of optical photons, which are absorbed in the first hundreds nanometers of the dice and give rise to surface events. In this work, we present the reconstruction of bulk events through the 59.5 keV $$\gamma $$ -ray generated by an $$^{241}$$ Am source, which emulates more closely the interaction of Dark Matter and neutrinos. The peak resolution is $$5\%~(\sigma )$$ and its position is shifted by less than $$10\%$$ with respect to the optical calibration. We observe that the resolution is further improved by a factor 2 combining the signal from neighboring dice. These results confirm the performance of the detector in view of the physics goals of the BULLKID-DM experiment for dark matter search. - Open Access
- 2 November 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (11) , 1-10
Strong enhancement of electromagnetic shower development in oriented scintillating crystals and implications for particle detectors
A particle traversing a crystal aligned with one of its crystallographic axes experiences a strong electromagnetic field that is constant along the direction of motion over macroscopic distances. For "Equation missing" and $$\gamma $$ -rays with energies above a few $$\textrm{GeV}$$ , this field is amplified by the Lorentz boost, to the point of exceeding the Schwinger critical field $$\mathcal {E}_0 \sim 1.32 \times 10^{16}~\mathrm {V/cm}$$ . In this regime, nonlinear quantum-electrodynamical effects occur, such as the enhancement of intense electromagnetic radiation emission and pair production, so that the electromagnetic shower development is accelerated and the effective shower length is reduced compared to amorphous materials. We have investigated this phenomenon in lead tungstate ( $$\textrm{PbWO}_4$$ ), a high- Z scintillator widely used in particle detection. We have observed a substantial increase in scintillation light at small incidence angles with respect to the main lattice axes. Measurements with $$120~\textrm{GeV}$$ electrons and $$\gamma $$ -rays between 5 and $$100~\textrm{GeV}$$ demonstrate up to a threefold increase in energy deposition in oriented samples. These findings challenge the current models of shower development in crystal scintillators and could guide the development of next-generation accelerator- and space-borne detectors.- 2 November 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (11) , 1-10
Open AccessStrong enhancement of electromagnetic shower development in oriented scintillating crystals and implications for particle detectors
A particle traversing a crystal aligned with one of its crystallographic axes experiences a strong electromagnetic field that is constant along the direction of motion over macroscopic distances. For "Equation missing" and $$\gamma $$ -rays with energies above a few $$\textrm{GeV}$$ , this field is amplified by the Lorentz boost, to the point of exceeding the Schwinger critical field $$\mathcal {E}_0 \sim 1.32 \times 10^{16}~\mathrm {V/cm}$$ . In this regime, nonlinear quantum-electrodynamical effects occur, such as the enhancement of intense electromagnetic radiation emission and pair production, so that the electromagnetic shower development is accelerated and the effective shower length is reduced compared to amorphous materials. We have investigated this phenomenon in lead tungstate ( $$\textrm{PbWO}_4$$ ), a high- Z scintillator widely used in particle detection. We have observed a substantial increase in scintillation light at small incidence angles with respect to the main lattice axes. Measurements with $$120~\textrm{GeV}$$ electrons and $$\gamma $$ -rays between 5 and $$100~\textrm{GeV}$$ demonstrate up to a threefold increase in energy deposition in oriented samples. These findings challenge the current models of shower development in crystal scintillators and could guide the development of next-generation accelerator- and space-borne detectors. - Open Access
- 8 April 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1076
From simulation to fabrication: Realizing silicon crystalline undulators with silicon nitride stressor layer patterning
- 8 April 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1076
Open AccessFrom simulation to fabrication: Realizing silicon crystalline undulators with silicon nitride stressor layer patterning
- Open Access
- 1 March 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1075
Coherent radiation in axially oriented industrial-grade tungsten crystals: A viable path for an innovative -rays and positron sources- 1 March 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1075
Open AccessCoherent radiation in axially oriented industrial-grade tungsten crystals: A viable path for an innovative -rays and positron sources - Open Access
- 1 October 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (10) , P10014
Particle identification capability of a homogeneous calorimeter composed of oriented crystals
Recent studies have shown that the electromagnetic shower induced by a high-energy electron, positron or photon incident along the axis of an oriented crystal develops in a space more compact than the ordinary. On the other hand, the properties of the hadronic interactions are not affected by the lattice structure. This means that, inside an oriented crystal, the natural difference between the hadronic and the electromagnetic shower profile is strongly accentuated. Thus, a calorimeter composed of oriented crystals could be intrinsically capable of identifying more accurately the nature of the incident particles, with respect to a detector composed only of non-aligned crystals. Since no oriented calorimeter has ever been developed, this possibility remains largely unexplored and can be investigated only by means of numerical simulations. In this work, we report the first quantitative evaluation of the particle identification capability of such a calorimeter, focusing on the case of neutron-gamma discrimination. We demonstrate through Geant4 simulations that the use of oriented crystals significantly improves the performance of a Random Forest classifier trained on the detector data. This work is a proof that oriented calorimeters could be a viable option for all the environments where particle identification must be performed with a very high accuracy, such as future high-intensity particle physics experiments and satellite-based γ-ray telescopes.
- 1 October 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (10) , P10014
Open AccessParticle identification capability of a homogeneous calorimeter composed of oriented crystals
Recent studies have shown that the electromagnetic shower induced by a high-energy electron, positron or photon incident along the axis of an oriented crystal develops in a space more compact than the ordinary. On the other hand, the properties of the hadronic interactions are not affected by the lattice structure. This means that, inside an oriented crystal, the natural difference between the hadronic and the electromagnetic shower profile is strongly accentuated. Thus, a calorimeter composed of oriented crystals could be intrinsically capable of identifying more accurately the nature of the incident particles, with respect to a detector composed only of non-aligned crystals. Since no oriented calorimeter has ever been developed, this possibility remains largely unexplored and can be investigated only by means of numerical simulations. In this work, we report the first quantitative evaluation of the particle identification capability of such a calorimeter, focusing on the case of neutron-gamma discrimination. We demonstrate through Geant4 simulations that the use of oriented crystals significantly improves the performance of a Random Forest classifier trained on the detector data. This work is a proof that oriented calorimeters could be a viable option for all the environments where particle identification must be performed with a very high accuracy, such as future high-intensity particle physics experiments and satellite-based γ-ray telescopes.
- Open Access
- 11 September 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
High-precision alignment techniques for realizing an ultracompact electromagnetic calorimeters using oriented high-Z scintillator crystals
- 11 September 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
Open AccessHigh-precision alignment techniques for realizing an ultracompact electromagnetic calorimeters using oriented high-Z scintillator crystals
- 1 July 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (7) , 074702
Development of a dedicated instrumentation for electrical and thermal characterization of chemiresistive gas sensors
This work presents the design and validation of a measuring instrumentation for an easy, complete, and tunable characterization of chemiresistive gas sensors based on metal-oxide semiconductors. The equipment, described in depth both as hardware and as software, was designed to monitor the electrical behavior of gas sensors in controlled thermodynamic conditions. The main goal of this setup is to synchronize the electrical characterization with different measuring conditions, i.e., operating temperature, relative humidity, and gas target concentration. This operation allows us to automate various measurement protocols, otherwise impossible to obtain manually. In particular, this instrumentation permits to correlate the response of a chemiresistive gas sensor to the applied voltage, to its working temperature, and to the gas concentration, automating the acquisition of the current–voltage characteristic and the current–temperature characteristic (Arrhenius plot) of sensing films. The experimental setup was validated by reporting the electrical characterization of a standard metal-oxide-based gas sensing material, such as SnO2, working under different thermodynamic conditions.
- 1 July 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (7) , 074702
Development of a dedicated instrumentation for electrical and thermal characterization of chemiresistive gas sensors
This work presents the design and validation of a measuring instrumentation for an easy, complete, and tunable characterization of chemiresistive gas sensors based on metal-oxide semiconductors. The equipment, described in depth both as hardware and as software, was designed to monitor the electrical behavior of gas sensors in controlled thermodynamic conditions. The main goal of this setup is to synchronize the electrical characterization with different measuring conditions, i.e., operating temperature, relative humidity, and gas target concentration. This operation allows us to automate various measurement protocols, otherwise impossible to obtain manually. In particular, this instrumentation permits to correlate the response of a chemiresistive gas sensor to the applied voltage, to its working temperature, and to the gas concentration, automating the acquisition of the current–voltage characteristic and the current–temperature characteristic (Arrhenius plot) of sensing films. The experimental setup was validated by reporting the electrical characterization of a standard metal-oxide-based gas sensing material, such as SnO2, working under different thermodynamic conditions.
- 30 May 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-01 (55) , 1400
Medical Parameters of a Sensing Device for Colorectal Cancer Preventive Screening through Fecal Odor Analysis
Colorectal cancer (CRC) is a worldwide diffused pathology for both men and women and it is the third most common cancer for both genders, in the United States[1] However, if promptly diagnosed, CRC is also one of the most curable tumor types (90% curability rate at stage I), therefore prevention is fundamental to avoid degeneration. Here the clinical validation outcomes of a preventive screening method based on a patented device, SCENT A1, composed by a core of nanostructured MOX sensors [2]. SCENT A1 is capable of detecting the presence of CRC from fecal odor with an in-vitro, inexpensive and non-invasive methodology. Fecal odor can be affected by the presence of CRC-biomarkers produced by membrane peroxidation and metabolic alterations [3,4]. The screening analysis adopted by NHS of Italy and of other countries is fecal occult blood test (FOBT). In Italy, FOBT is performed every two years on subjects from 50 to 69 years old and shows a huge percentage of false positives (about 65% according to data). FOBT-positives are then invited to undergo colonoscopy. SCENT A1 is capable of reducing FOBT false positives and so the total number of non-operative colonoscopies with related risks (e.g. bowel perforation). The device, presently undergoing instrumental certification, is composed by a core of two chemoresistive MOX sensors, chosen and calibrated for this specific aim [5-11]. Sensors (Figure 1) have been synthesized at Sensor Laboratory of the University of Ferrara and are composed by a nanostructured semiconductor film screen-printed onto an alumina substrate and a platinum heater to modulate operating temperature. The first sensor is composed by Iron and Samarium oxides while the second one by Tin and Titanium oxides. The data collection and analysis software employs support vector machine (SVM) [9]. The clinical validation protocol of this device started in May 2016 and ended in July 2019, in collaboration with Hospital St. Anna of Ferrara and Department of Public Health of Ferrara. A total of 398 fecal samples of FOBT-positive subjects have been analyzed by SCENT A1 system with the k-fold cross validation method. Samples have been grouped into two macro categories, depending on the gold-standard (colonoscopy) outcomes: 260 healthy subjects (negative to colonoscopy); 138 colorectal adenomas and carcinomas (positive to colonoscopy), 54 low-risk adenomas and 84 high-risk adenomas and carcinomas. The system has been capable of distinguishing among these two categories with a sensitivity (TPR: true positive rate) and specificity (TNR: true negative rate) respectively of 84,1% and 82,4%, defined as follows: TPR=TP/P=TP/(FN+TP); TN/N=TN/(FP+TN); where TP, TN, FP and FN are the abbreviations that indicate respectively true positives, true negatives, false positives and false negatives. The choice to group carcinomas, high- and low-risk adenomas into a single class and not into two diverse classes as before [10], has simplified the test and ensured greater doctor protection, despite a small loss in specificity. Low-risk adenomas are, in fact, often similar to healthy tissues and have a risk of evolving into cancer comparable to the risk of colonoscopy complications. As already emerging from a previous study [10-11], in fact, the major error of classification (only 57%) concerned just low-risk tumors that emit gases halfway between healthy and tumoral samples. What emerges is that, if SCENT A1 test is carried out on FOBT-positives subjects as a second check, it would guarantee a reduction of about two thirds of the colonoscopies performed on healthy patients. A new collaboration, involving private clinic Quisisana, started in 2020 with some laboratory tests on sensors reproducibility [12] will continue in January 2021 with tests on patients directly inside the clinic, in order to test the new shape of the device under certification. Moreover, if employed by the NHS of countries without screening system, this method will significantly reduce CRC-mortality rate. [1] [https://www.cancer.org/cancer/colon-rectal-cancer/about/key-statistics.html [2] Italian #: RM2014A000595, European #: 3210013 (Germany, UK); [3] B. Szachowicz-Petelska et al., NMR in Biomedicine V5,226–233, 1992; [4] T. G. de Meij et al., International Journal of Cancer (2014), 134, 1132–1138; [5] C. Malagù et al., Sensors, 14, 18982-18992, 2014; [6] G. Zonta et al., Sensors and Actuators B, 218, 289-295, 2015; [7] N. Landini et al., Scholars' Press, ISBN-13: 978-3-639-76538-0; [8] G. Zonta et al., Sensors and Actuators B, 238, 1098–110, 2016; [9] G. Zonta et al., Sensors and Actuators B 262 (2018) 884–891; [10] G. Zonta et al., Sensors and Actuators B: Chemical, Volume 301, 12 December 2019, 127062; [11] G. Zonta et al., Cancers 2020, 12(6), 1471; [12] G. Zonta et al., Ceramics International Volume 46, Issue 5, 1 April 2020, Pages 6847-6855. Figure 1: a) external view of the patented prototype SCENT A1, composed by flowmeters, a flow diverter and a sample box; b) one of the chemoresistive sensors composing the core of the instrument; c) magnificated scheme of the sensor. Figure 1
- 30 May 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-01 (55) , 1400
Medical Parameters of a Sensing Device for Colorectal Cancer Preventive Screening through Fecal Odor Analysis
Colorectal cancer (CRC) is a worldwide diffused pathology for both men and women and it is the third most common cancer for both genders, in the United States[1] However, if promptly diagnosed, CRC is also one of the most curable tumor types (90% curability rate at stage I), therefore prevention is fundamental to avoid degeneration. Here the clinical validation outcomes of a preventive screening method based on a patented device, SCENT A1, composed by a core of nanostructured MOX sensors [2]. SCENT A1 is capable of detecting the presence of CRC from fecal odor with an in-vitro, inexpensive and non-invasive methodology. Fecal odor can be affected by the presence of CRC-biomarkers produced by membrane peroxidation and metabolic alterations [3,4]. The screening analysis adopted by NHS of Italy and of other countries is fecal occult blood test (FOBT). In Italy, FOBT is performed every two years on subjects from 50 to 69 years old and shows a huge percentage of false positives (about 65% according to data). FOBT-positives are then invited to undergo colonoscopy. SCENT A1 is capable of reducing FOBT false positives and so the total number of non-operative colonoscopies with related risks (e.g. bowel perforation). The device, presently undergoing instrumental certification, is composed by a core of two chemoresistive MOX sensors, chosen and calibrated for this specific aim [5-11]. Sensors (Figure 1) have been synthesized at Sensor Laboratory of the University of Ferrara and are composed by a nanostructured semiconductor film screen-printed onto an alumina substrate and a platinum heater to modulate operating temperature. The first sensor is composed by Iron and Samarium oxides while the second one by Tin and Titanium oxides. The data collection and analysis software employs support vector machine (SVM) [9]. The clinical validation protocol of this device started in May 2016 and ended in July 2019, in collaboration with Hospital St. Anna of Ferrara and Department of Public Health of Ferrara. A total of 398 fecal samples of FOBT-positive subjects have been analyzed by SCENT A1 system with the k-fold cross validation method. Samples have been grouped into two macro categories, depending on the gold-standard (colonoscopy) outcomes: 260 healthy subjects (negative to colonoscopy); 138 colorectal adenomas and carcinomas (positive to colonoscopy), 54 low-risk adenomas and 84 high-risk adenomas and carcinomas. The system has been capable of distinguishing among these two categories with a sensitivity (TPR: true positive rate) and specificity (TNR: true negative rate) respectively of 84,1% and 82,4%, defined as follows: TPR=TP/P=TP/(FN+TP); TN/N=TN/(FP+TN); where TP, TN, FP and FN are the abbreviations that indicate respectively true positives, true negatives, false positives and false negatives. The choice to group carcinomas, high- and low-risk adenomas into a single class and not into two diverse classes as before [10], has simplified the test and ensured greater doctor protection, despite a small loss in specificity. Low-risk adenomas are, in fact, often similar to healthy tissues and have a risk of evolving into cancer comparable to the risk of colonoscopy complications. As already emerging from a previous study [10-11], in fact, the major error of classification (only 57%) concerned just low-risk tumors that emit gases halfway between healthy and tumoral samples. What emerges is that, if SCENT A1 test is carried out on FOBT-positives subjects as a second check, it would guarantee a reduction of about two thirds of the colonoscopies performed on healthy patients. A new collaboration, involving private clinic Quisisana, started in 2020 with some laboratory tests on sensors reproducibility [12] will continue in January 2021 with tests on patients directly inside the clinic, in order to test the new shape of the device under certification. Moreover, if employed by the NHS of countries without screening system, this method will significantly reduce CRC-mortality rate. [1] [https://www.cancer.org/cancer/colon-rectal-cancer/about/key-statistics.html [2] Italian #: RM2014A000595, European #: 3210013 (Germany, UK); [3] B. Szachowicz-Petelska et al., NMR in Biomedicine V5,226–233, 1992; [4] T. G. de Meij et al., International Journal of Cancer (2014), 134, 1132–1138; [5] C. Malagù et al., Sensors, 14, 18982-18992, 2014; [6] G. Zonta et al., Sensors and Actuators B, 218, 289-295, 2015; [7] N. Landini et al., Scholars' Press, ISBN-13: 978-3-639-76538-0; [8] G. Zonta et al., Sensors and Actuators B, 238, 1098–110, 2016; [9] G. Zonta et al., Sensors and Actuators B 262 (2018) 884–891; [10] G. Zonta et al., Sensors and Actuators B: Chemical, Volume 301, 12 December 2019, 127062; [11] G. Zonta et al., Cancers 2020, 12(6), 1471; [12] G. Zonta et al., Ceramics International Volume 46, Issue 5, 1 April 2020, Pages 6847-6855. Figure 1: a) external view of the patented prototype SCENT A1, composed by flowmeters, a flow diverter and a sample box; b) one of the chemoresistive sensors composing the core of the instrument; c) magnificated scheme of the sensor. Figure 1
- 30 May 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-01 (63) , 1704
Nickel-Decorated Black Phosphorus for Room Temperature NO2 Detection
Introduction In the rapidly emerging field of layered two-dimensional (2D) functional materials, bP, the all P-counterpart of graphene, is a potential candidate for various applications e.g., nanoscale optoelectronics, rechargeable ion batteries, electrocatalysts, thermoelectrics, solar cells, and sensors [1]. bP has been reported to exhibit superior chemical sensing performance. In particular, bP is selective for the detection of paramagnetic molecules, e.g., NO2, in addition to high sensitivity at a limit of detection (LOD) of ppb levels.[2] In this work, by applying a multiscale characterization approach we demonstrated a stability and functionality improvement of Nickel-decorated bP (Ni/bP) films for gas sensing prepared by a simple, reproducible and affordable deposition technique. Furthermore, we studied pos-sible electrical activity of these films for their employment as functional layers in gas sensors by exposing them to different gaseous compounds (NO2, CO2, H2, NH3, CO, Benzene, etha-nol, ethylene, Formaldehyde) in different relative humidity (RH%) conditions. Moreover, the influence in sensing perfor-mance of nickel nanoparticle (NP) dimensions in related to the decoration technique and the film thickness were investigated. Materials and Methods Black phosphorus microcrystals were suspended in dimethylsulfoxide and kept under ultrasonication for several hours. The exfoliated bP nanosheets were decorated with nickel nanoparticles following two different procedures: 1) preformed Ni NPs were immobilized on bP, 2) Ni NPs were grown directly on bP flakes. Electrical conductance measurements have been performed on Ni/bP flakes deposited via spin coating on Al2O3 substrates with built-in interdigitated gold electrodes, in order to better control the film thickness. Electrical conductance measurements have been performed at RT (25±2°C) by exposing the sensing film to certified mixtures of NO2 diluted in dry air (20% O2 and 80% N2) with different NO2 concentration ranging from 200 ppb to 1 ppm. Results and Conclusions Exfoliated black phosphorus nanoflakes decorated with nickel nanoparticles (Ni/bP) have been prepared and characterized with particular attention to the role of Ni nanoparticle dimension in the sensing mechanism. Electrical activity towards different concentrations of NO2 at room temperature in a dry air environment highlighted fast and stable response over the time. This latter characteristic is particularly relevant since environmental instability of exfoliated BP has been an issue so far, under ambient conditions few-layer bP degrades completely in less than a week, preventing its applications in several fields. In situ grown Ni/bP (2) shows stable response during all the four weeks measurements period with no dependence of the response on the film thickness. Ni decoration effectively suppress ambient degradation, for at least 1 week in Ni/bP (1) and over 4 weeks in Ni/bP (2) in ambient conditions. This result highlighted that Ni/bP (2) sensor can be practically used under ambient conditions for a reasonable period without performance degradation of the devices. The obtained results pave the way for the use of chemically exfoliated bP flakes for gas sensing applications, avoiding the use of a time-consuming technique for the exfoliation and for the fabrication of the metallic contacts, like electron beam lithography, focused ion beam lithography, etc. References [1] Batmunkh, M.; Bat-Erdene, M.; Shapter, J. G. Phosphorene and Phosphorene-Based Materials - Prospects for Future Applications. Adv. Mater. 2016, 28, 8586– 8617. [2] Donarelli, M.; Ottaviano, L.; Giancaterini, L.; Fioravanti, G.; Perrozzi, F.; Cantalini, C. Exfoliated black phosphorus gas sensing properties at room temperature. 2D Mater. 2016, 3, 025002 Caption Fig.1:(a) Electrical characterization at room temperature of bP, Ni/bP (1) and Ni/bP (2) devices in dry conditions with five different concentration of NO2. (b) Calibration curve of Ni/bP based sensors in dry condition. Figure 1
- 30 May 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-01 (63) , 1704
Nickel-Decorated Black Phosphorus for Room Temperature NO2 Detection
Introduction In the rapidly emerging field of layered two-dimensional (2D) functional materials, bP, the all P-counterpart of graphene, is a potential candidate for various applications e.g., nanoscale optoelectronics, rechargeable ion batteries, electrocatalysts, thermoelectrics, solar cells, and sensors [1]. bP has been reported to exhibit superior chemical sensing performance. In particular, bP is selective for the detection of paramagnetic molecules, e.g., NO2, in addition to high sensitivity at a limit of detection (LOD) of ppb levels.[2] In this work, by applying a multiscale characterization approach we demonstrated a stability and functionality improvement of Nickel-decorated bP (Ni/bP) films for gas sensing prepared by a simple, reproducible and affordable deposition technique. Furthermore, we studied pos-sible electrical activity of these films for their employment as functional layers in gas sensors by exposing them to different gaseous compounds (NO2, CO2, H2, NH3, CO, Benzene, etha-nol, ethylene, Formaldehyde) in different relative humidity (RH%) conditions. Moreover, the influence in sensing perfor-mance of nickel nanoparticle (NP) dimensions in related to the decoration technique and the film thickness were investigated. Materials and Methods Black phosphorus microcrystals were suspended in dimethylsulfoxide and kept under ultrasonication for several hours. The exfoliated bP nanosheets were decorated with nickel nanoparticles following two different procedures: 1) preformed Ni NPs were immobilized on bP, 2) Ni NPs were grown directly on bP flakes. Electrical conductance measurements have been performed on Ni/bP flakes deposited via spin coating on Al2O3 substrates with built-in interdigitated gold electrodes, in order to better control the film thickness. Electrical conductance measurements have been performed at RT (25±2°C) by exposing the sensing film to certified mixtures of NO2 diluted in dry air (20% O2 and 80% N2) with different NO2 concentration ranging from 200 ppb to 1 ppm. Results and Conclusions Exfoliated black phosphorus nanoflakes decorated with nickel nanoparticles (Ni/bP) have been prepared and characterized with particular attention to the role of Ni nanoparticle dimension in the sensing mechanism. Electrical activity towards different concentrations of NO2 at room temperature in a dry air environment highlighted fast and stable response over the time. This latter characteristic is particularly relevant since environmental instability of exfoliated BP has been an issue so far, under ambient conditions few-layer bP degrades completely in less than a week, preventing its applications in several fields. In situ grown Ni/bP (2) shows stable response during all the four weeks measurements period with no dependence of the response on the film thickness. Ni decoration effectively suppress ambient degradation, for at least 1 week in Ni/bP (1) and over 4 weeks in Ni/bP (2) in ambient conditions. This result highlighted that Ni/bP (2) sensor can be practically used under ambient conditions for a reasonable period without performance degradation of the devices. The obtained results pave the way for the use of chemically exfoliated bP flakes for gas sensing applications, avoiding the use of a time-consuming technique for the exfoliation and for the fabrication of the metallic contacts, like electron beam lithography, focused ion beam lithography, etc. References [1] Batmunkh, M.; Bat-Erdene, M.; Shapter, J. G. Phosphorene and Phosphorene-Based Materials - Prospects for Future Applications. Adv. Mater. 2016, 28, 8586– 8617. [2] Donarelli, M.; Ottaviano, L.; Giancaterini, L.; Fioravanti, G.; Perrozzi, F.; Cantalini, C. Exfoliated black phosphorus gas sensing properties at room temperature. 2D Mater. 2016, 3, 025002 Caption Fig.1:(a) Electrical characterization at room temperature of bP, Ni/bP (1) and Ni/bP (2) devices in dry conditions with five different concentration of NO2. (b) Calibration curve of Ni/bP based sensors in dry condition. Figure 1