PWPing Wen

Ping Wen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ping Wen has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Li Chen

    College of Optoelectronic Engineering, Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Key Disciplines Lab of Novel Micro-Nano Devices and System Technology, Chongqing University, Chongqing 400044, China

    3 shared publications
  • Shunbo Li

    Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education & Key Disciplines Laboratory of Novel Micro-Nano Devices and System Technology, College of Optoelectronic Engineering, Chongqing University, Chongqing, 400044, China; International R & D Center of Micro-nano Systems and New Materials Technology, Chongqing University, Chongqing, 400044, China

    3 shared publications
  • Yi Xu

    College of Optoelectronic Engineering, Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Key Disciplines Lab of Novel Micro-Nano Devices and System Technology, Chongqing University, Chongqing 400044, China

    3 shared publications
  • Feng Yang

    School of Artificial Intelligence, Chongqing Key Laboratory of Intelligent Perception and Blockchain, Chongqing Technology and Business University, Chongqing 400067, China

    2 shared publications
  • Feng Yang

    Chongqing Technology and Business University

    2 shared publications
  • Haixia Zhao

    College of Optoelectronic Engineering, Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Key Disciplines Lab of Novel Micro-Nano Devices and System Technology, Chongqing University, Chongqing 400044, China

    2 shared publications

Latest Publications

  • Pump-Free Generation of Stable Two-Dimensional Chemical Concentration Gradients in a Microwell Array Device for Combinatorial Drug Screening

    by Qi Zhang, Li Ran, Ping Wen, Feng Yang, Bangyong Sun, Gang Li

    The generation of stable, discrete two-dimensional (2D) chemical concentration gradients is pivotal for high-throughput combinatorial drug screening and multi-factor biological studies. However, existing methods often rely on complex external instrumentation, hindering their utility in resource-limited settings. Herein, we present a pump-free operation microfluidic platform that synergistically integrates vacuum-driven priming, Laplace pressure-driven flow, and dewetting-induced discretization to establish and stabilize orthogonal linear concentration gradients within a microwell array. This approach enables the robust generation of highly linear (R2 > 0.97) and stable gradients in less than 8 min using only a standard pipette. We demonstrated the platform’s utility in combinatorial drug screening by assessing the synergy between 5-fluorouracil (5-FU) and curcumin against MDA-MB-231 breast cancer spheroids, revealing enhanced cytotoxicity under the combination treatment, with spheroid viability decreasing to 43.1% compared with 66.3% for 5-FU monotherapy. This operationally pump-free and scalable platform lowers the barrier to high-throughput combinatorial analysis, offering a practical solution for drug discovery and biological research, particularly in resource-limited settings.

  • Microcavity Array-Based Digital SERS Chip for Rapid and Accurate Label-free Quantitative Detection of Live Bacteria

    by Ping Wen, Feng Yang, Haixia Zhao, Shunbo Li, Yi Xu, Li Chen

    In this study, we developed a novel digital surface-enhanced Raman spectroscopy (SERS) chip that integrates an inverted pyramid microcavity array, a microchannel cover plate, and a multilayer gold nanoparticle (AuNP) SERS substrate. This innovative design exploits the synergistic effects of the microcavity array and the microchannel to enable rapid and large-scale digital discretization of bacterial suspensions. The concentration effect of the picoliter cavities, combined with the superior Raman enhancement effect of the multilayer AuNP SERS substrate, allows for the precise identification of live bacteria within the microcavities through in situ and label-free SERS testing after a short incubation period. By counting the resulting positive or negative signals, the concentration of the target analyte can be directly determined via Poisson statistics. Experimental results demonstrate that this method enables the accurate quantification of Escherichia coli (E. coli) BL21 within a 4-h incubation period. Compared with traditional analog SERS detection methods, our proposed digital SERS detection strategy reduces the impact of signal intensity fluctuations, thereby significantly improving detection efficiency and accuracy. We believe that this digital SERS chip has great application prospects in the fields of bacterial detection, antibiotic resistance analysis, and cellular dynamics monitoring.


  • Novel Digital SERS-Microfluidic Chip for Rapid and Accurate Quantification of Microorganisms

    by Ping Wen, Feng Yang, Haixia Zhao, Yi Xu, Shunbo Li, Li Chen

    In this work, we present a simple and novel digital surface-enhanced Raman spectroscopy (SERS)-microfluidic chip designed for the rapid and accurate quantitative detection of microorganisms. The chip employs a high-density inverted pyramid microcavity (IPM) array to separate and isolate microbial samples. The presence or absence of target microorganisms is determined by scanning the IPM array using SERS and identifying the characteristic Raman bands. This approach allows for the "digitization" of the SERS response of each IPM, enabling quantification through the application of mathematical statistical techniques. Significantly, precise quantitative detection of yeast was achieved within a concentration range of 106-109 cells/mL, with the maximum relative standard deviation from the concentration calibrated by the cultivation method being 5.6%. This innovative approach efficiently addresses the issue of irregularities in SERS quantitative detection, which arises due to fluctuations in SERS intensity and poor reproducibility. We strongly believe that this digital SERS-microfluidic chip holds immense potential for diverse applications in the rapid detection of various microorganisms, including pathogenic bacteria and viruses.


  • Self-assembled nano-Ag/Au@Au film composite SERS substrates show high uniformity and high enhancement factor for creatinine detection

    by Ping Wen, Feng Yang, Chuang Ge, Shunbo Li, Yi Xu, Li Chen

    Serum creatinine is a key biomarker for the diagnosis and monitoring of kidney disease. Rapid and sensitive creatinine detection is thus important. Here, we propose a high-performance nano-Ag/Au@Au film composite SERS substrate for the rapid detection of creatinine in human serum. Au nanoparticles (AuNPs) and Ag nanoparticles (AgNPs) with uniform particle size were synthesized by a chemical reduction method, and the nano-Ag/Au@Au film composite SERS substrate was successfully prepared via a consecutive layer-on-layer deposition using an optimized liquid–liquid interface self-assembly method. The finite element simulation analysis showed that due to the multi-dimensional plasmonic coupling effect formed between the AuNPs, AgNPs, and the Au film, the intensity of the local electromagnetic field was greatly improved, and a very high enhancement factor (EF) was obtained. Experimental results showed that the limit of detection (LOD) of this composite SERS substrate for rhodamine 6G (R6G) molecules was as low as 1 × 10 −13 M, and the Raman EF was 15.7 and 2.9 times that of the AuNP and AgNP monolayer substrates respectively. The results of different batch tests and SERS mapping showed that the relative standard deviations of the Raman intensity of R6G at 612 cm −1 were 12.5% and 11.7%, respectively. Finally, we used the SERS substrate for the label-free detection of human serum creatinine. The results showed that the LOD of this SERS substrate for serum creatinine was 5 × 10 −6 M with a linear correlation coefficient of 0.96. In conclusion, the SERS substrate has high sensitivity, good uniformity, simple preparation, and has important developmental potential for the rapid detection and application of disease biomarkers.