Rajesh Kumar Gupta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rajesh Kumar Gupta has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Nidhi Rani
Department of Conservative Dentistry and Endodontics, Advanced Oral Health Care Centre, Zirakpur, Punjab, India
2 shared publicationsBaljeet Singh
Department of Periodontology and Oral Implantology, Himachal Dental College, Sunder Nagar, Himachal Pradesh, India
1 shared publication- Baljeet Singh
Department of Periodontology, Bhojia Dental College and Hospital, Baddi, Himachal Pradesh, India
1 shared publication Bharat Joshi
Department of Periodontology, Swami Devi Dyal Dental College and Hospital, Barwala, Haryana, India
1 shared publication- Nidhi Rani
Unit of Conservative Dentistry & Endodontics, Oral Health Sciences Centre, Post Graduate Institute of Medical Education & Research (PGIMER), Chandigarh, India
1 shared publication Rahul Sathu
Department of Periodontology and Oral Implantology, Swami Devi Dyal Hospital and Dental College, Barwala, Haryana, India
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by Wolters Kluwer Health in Journal of Indian Society of Periodontology
- Vol. 29 (1) , 85-90
Survival of narrow diameter implants in supporting single crowns in the molar region of the jaw
Purpose: The present investigation assessed the success of narrow diameter implants (NDI) supporting a single crown in the molar region of the jaw. Materials and Methods: A total of 40 patients (>20 years) requiring implant supported crown in the molar region were recruited. A total of 20 patients received NDI (3.5 millimeter (mm), and another 20 received standard diameter implants (SDI), ≥3.75 mm. Crestal bone level, probing depth (PD), implant mobility, and bleeding on probing (BOP) were recorded at baseline, 6, and 12 months. Results: The control group showed 0.29 ± 0.17 of mean crestal bone loss at 6 months and 0.51 ± 0.21 at 12 months ( P < 0.001). In the test group, mean crestal bone loss of 0.18 ± 0.15 at 6 months ( P = 0.001) and 0.48 ± 0.27 ( P < 0.001) at 12 months was observed. Intergroup comparison at 12 months was nonsignificant ( P = 0.13). An increase of 0.24 ± 0.24 PD at 6 months and of 0.44 ± 0.32 at 12 months was seen in the control group ( P = 0.001). The test group revealed an increase of 0.42 ± 0.26 and 0.63 ± 0.42 PD from baseline to 6 and 12 months, respectively ( P < 0.001). Comparison between groups did not show a significant difference at the study end ( P = 0.06). Regarding BOP, a difference of 0.03 ± 0.76 ( P = 0.15) at 6 months and of 0.13 ± 0.20 ( P = 0.01) at 12 months from baseline was observed in the control group. In the test group, the difference of 0.01 at 6 months ( P = 0.31) and 0.20 at 12 months ( P = 0.006) from baseline was seen. Intergroup comparisons were nonsignificant at the end of the research ( P = 0.44). Conclusions: NDI supporting single crown functioned similarly and successfully to SDI when subjected to high masticatory loads.
- 1 January 2025
- Published by Wolters Kluwer Health in Journal of Indian Society of Periodontology
- Vol. 29 (1) , 85-90
Open AccessSurvival of narrow diameter implants in supporting single crowns in the molar region of the jaw
Purpose: The present investigation assessed the success of narrow diameter implants (NDI) supporting a single crown in the molar region of the jaw. Materials and Methods: A total of 40 patients (>20 years) requiring implant supported crown in the molar region were recruited. A total of 20 patients received NDI (3.5 millimeter (mm), and another 20 received standard diameter implants (SDI), ≥3.75 mm. Crestal bone level, probing depth (PD), implant mobility, and bleeding on probing (BOP) were recorded at baseline, 6, and 12 months. Results: The control group showed 0.29 ± 0.17 of mean crestal bone loss at 6 months and 0.51 ± 0.21 at 12 months ( P < 0.001). In the test group, mean crestal bone loss of 0.18 ± 0.15 at 6 months ( P = 0.001) and 0.48 ± 0.27 ( P < 0.001) at 12 months was observed. Intergroup comparison at 12 months was nonsignificant ( P = 0.13). An increase of 0.24 ± 0.24 PD at 6 months and of 0.44 ± 0.32 at 12 months was seen in the control group ( P = 0.001). The test group revealed an increase of 0.42 ± 0.26 and 0.63 ± 0.42 PD from baseline to 6 and 12 months, respectively ( P < 0.001). Comparison between groups did not show a significant difference at the study end ( P = 0.06). Regarding BOP, a difference of 0.03 ± 0.76 ( P = 0.15) at 6 months and of 0.13 ± 0.20 ( P = 0.01) at 12 months from baseline was observed in the control group. In the test group, the difference of 0.01 at 6 months ( P = 0.31) and 0.20 at 12 months ( P = 0.006) from baseline was seen. Intergroup comparisons were nonsignificant at the end of the research ( P = 0.44). Conclusions: NDI supporting single crown functioned similarly and successfully to SDI when subjected to high masticatory loads.
- Open Access
- 1 January 2019
- Published by Medknow in Journal of Indian Society of Periodontology
- Vol. 23 (2) , 124-130
Effect of laser application in the healing of intrabony defects treated with bioactive glass
Aims: Presence of bacteria within the environment of infrabony pockets affects healing during their treatment. Present investigation utilized a diode laser for pocket sanitization before the placement of bone biomaterial with the aim of enhancing the healing. Materials and Methods: Twelve patients with bilateral intrabony defects participated in a split-mouth study design. Control group received biomaterial application only after surgical debridement. Infrabony pockets in the test group were irradiated with 810-nm diode laser at 0.8 W, continuous wave for 20 s before surgical debridement and biomaterial application. Healing was assessed using clinical and radiologic parameters. Results: Control group showed mean probing depth (PD) reduction of 3.25 ± 0.62 at 3, 4.08 ± 0.90 mm at 6 months. 3.00 ± 0.73 at 3, 3.91 ± 0.66 mm at 6 months reduction in mean PD was seen in the test group (P < 0.001). No statistically significant differences between the groups were observed. A gain of 2.50 ± 0.67 at 3, 3.25 ± 0.62 mm at 6 months in relative clinical attachment level was seen in the control and of 2.33 ± 0.77 at 3, 3.16 ± 0.57 mm at 6 months in the test group (P < 0.001) without significant differences between groups. 1.33 ± 0.57 and 0.95 ± 0.68 mm hard-tissue fill (difference in the radiographic distance between cementoenamel junction and base of the intrabony defect pre- and post-operative) at 6 months was observed in the control and test groups, respectively (P < 0.001). Between groups differences (0.22 ± 0.24 mm) were not significant. Conclusions: Similar reduction in soft- and hard-tissue parameters in both groups indicates that adjunctive pocket sanitization with diode laser did not improve the healing of intrabony defects treated with bioactive glass.
- 1 January 2019
- Published by Medknow in Journal of Indian Society of Periodontology
- Vol. 23 (2) , 124-130
Open AccessEffect of laser application in the healing of intrabony defects treated with bioactive glass
Aims: Presence of bacteria within the environment of infrabony pockets affects healing during their treatment. Present investigation utilized a diode laser for pocket sanitization before the placement of bone biomaterial with the aim of enhancing the healing. Materials and Methods: Twelve patients with bilateral intrabony defects participated in a split-mouth study design. Control group received biomaterial application only after surgical debridement. Infrabony pockets in the test group were irradiated with 810-nm diode laser at 0.8 W, continuous wave for 20 s before surgical debridement and biomaterial application. Healing was assessed using clinical and radiologic parameters. Results: Control group showed mean probing depth (PD) reduction of 3.25 ± 0.62 at 3, 4.08 ± 0.90 mm at 6 months. 3.00 ± 0.73 at 3, 3.91 ± 0.66 mm at 6 months reduction in mean PD was seen in the test group (P < 0.001). No statistically significant differences between the groups were observed. A gain of 2.50 ± 0.67 at 3, 3.25 ± 0.62 mm at 6 months in relative clinical attachment level was seen in the control and of 2.33 ± 0.77 at 3, 3.16 ± 0.57 mm at 6 months in the test group (P < 0.001) without significant differences between groups. 1.33 ± 0.57 and 0.95 ± 0.68 mm hard-tissue fill (difference in the radiographic distance between cementoenamel junction and base of the intrabony defect pre- and post-operative) at 6 months was observed in the control and test groups, respectively (P < 0.001). Between groups differences (0.22 ± 0.24 mm) were not significant. Conclusions: Similar reduction in soft- and hard-tissue parameters in both groups indicates that adjunctive pocket sanitization with diode laser did not improve the healing of intrabony defects treated with bioactive glass.
- Open Access
- 1 January 2017
- Published by Medknow in Journal of Indian Society of Periodontology
- Vol. 21 (6) , 499-502
Proliferative verrucous leukoplakia misdiagnosed as oral leukoplakia
Roliferative verrucous leukoplakia (PVL) is a distinct form of oral leukoplakia characterized by a high recurrence rate and high rate of transformation into oral squamous cell carcinoma. We present herein a case of PVL which was misdiagnosed as oral leukoplakia and progressed to oral carcinoma....
- 1 January 2017
- Published by Medknow in Journal of Indian Society of Periodontology
- Vol. 21 (6) , 499-502
Open AccessProliferative verrucous leukoplakia misdiagnosed as oral leukoplakia
Roliferative verrucous leukoplakia (PVL) is a distinct form of oral leukoplakia characterized by a high recurrence rate and high rate of transformation into oral squamous cell carcinoma. We present herein a case of PVL which was misdiagnosed as oral leukoplakia and progressed to oral carcinoma....