Sheetal Makwana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sheetal Makwana has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Veerabhadragouda B. Patil
University of Pardubice
2 shared publications Anamik Shah
1 shared publication- Anamik Shah
Department of Chemistry, Saurashtra University, Rajkot 360005, Gujarat, India
1 shared publication Jatin Upadhyay
1 shared publication- Jatin Upadhyay
Matushri Virbaima Mahila Science & Home Science College, Rajkot-360007, Gujarat, India
1 shared publication Madhavi Patel
1 shared publication
Latest Publications
- 5 November 2023
- Published by Elsevier in Journal of the Indian Chemical Society
- Vol. 100 (12)
A column screening study: Validation of a RP-LC method for determination of teriflunomide with pentafluorophenyl stationary phase
- 5 November 2023
- Published by Elsevier in Journal of the Indian Chemical Society
- Vol. 100 (12)
A column screening study: Validation of a RP-LC method for determination of teriflunomide with pentafluorophenyl stationary phase
- 4 July 2021
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 11 (4) , 580-595
A Validated Stability-Indicating Method for Separation of Prucalopride Drug by HPLC: Method Transfer to UPLC
The presented research work is based on a quick study of Prucalopride succinate (PRS) by a novel approach of method transfer from High-Performance Liquid Chromatography to Ultra Performance Liquid Chromatography by using UV and PDA detector, respectively; with detailed forced degradation study with its significance. The validation study was carried out for the pure, active pharmaceutical ingredient of the PRS standard with respect to PRS sample. For HPLC-UV, Symmetry C8 (4.6 mm x 100 mm, 5 µm) and for UPLC-PDA, Waters Acquity BEH C8 (2.1 mm x 100 mm, 1.7 µm id) was used for the analysis. The analysis was carried out with 20 mM ammonium formate (3.0 pH with formic acid) and acetonitrile in the composition of (82: 18, v/v) with 0.80 mL/min of flow and (75: 25, v/v) with 0.250 mL/min of flow for HPLC and UPLC, respectively with 276 nm of detection wavelength which shows the ruggedness of the method. The retention time and analysis time of PRS in UPLC are shorter as compared to HPLC. The correlation coefficient of the linearity study was 0.9999 for both instruments. The method is also tested for specificity study of PRS, which shows the method is very simple, rapid and precise with the significance of method transfer. The % RSD values of validation parameters were within the acceptance criteria as per the International Conference of Harmonization (ICH) guidelines. This validated stability indicating method shows the less consumption of solvent, faster analysis and less concentration amount of drug-loaded in a column indicates greener advantages with sensitive detection limit. GRAPHICAL ABSTRACT
- 4 July 2021
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 11 (4) , 580-595
A Validated Stability-Indicating Method for Separation of Prucalopride Drug by HPLC: Method Transfer to UPLC
The presented research work is based on a quick study of Prucalopride succinate (PRS) by a novel approach of method transfer from High-Performance Liquid Chromatography to Ultra Performance Liquid Chromatography by using UV and PDA detector, respectively; with detailed forced degradation study with its significance. The validation study was carried out for the pure, active pharmaceutical ingredient of the PRS standard with respect to PRS sample. For HPLC-UV, Symmetry C8 (4.6 mm x 100 mm, 5 µm) and for UPLC-PDA, Waters Acquity BEH C8 (2.1 mm x 100 mm, 1.7 µm id) was used for the analysis. The analysis was carried out with 20 mM ammonium formate (3.0 pH with formic acid) and acetonitrile in the composition of (82: 18, v/v) with 0.80 mL/min of flow and (75: 25, v/v) with 0.250 mL/min of flow for HPLC and UPLC, respectively with 276 nm of detection wavelength which shows the ruggedness of the method. The retention time and analysis time of PRS in UPLC are shorter as compared to HPLC. The correlation coefficient of the linearity study was 0.9999 for both instruments. The method is also tested for specificity study of PRS, which shows the method is very simple, rapid and precise with the significance of method transfer. The % RSD values of validation parameters were within the acceptance criteria as per the International Conference of Harmonization (ICH) guidelines. This validated stability indicating method shows the less consumption of solvent, faster analysis and less concentration amount of drug-loaded in a column indicates greener advantages with sensitive detection limit. GRAPHICAL ABSTRACT