Saleh Mbbch Alsaifi
Saleh Mbbch Alsaifi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Abdulrahman Al-Otaibi
Department of Orthopedic Surgery, Security Forces Hospital, P.O. Box 3643, Riyadh 11481, Saudi Arabia
1 shared publication - Ahmed Mohamed Abdelaziz
Pediatric Orthopedics and Deformity Divisions
1 shared publication - Ali Al-Ghufaily
Department of Orthopedic Surgery, Security Forces Hospital, P.O. Box 3643, Riyadh 11481, Saudi Arabia
1 shared publication - Ali Lari
Department of Orthopedic Surgery Ministry of Health AlRazi National Orthopedic Hospital 4407 Kuwait City Kuwait
1 shared publication - Aliaa Khaja
Al Razi Orthopedic Hospital, Kuwait
1 shared publication - Bogdan Matache
Division of Orthopedic Surgery, Ottawa General Hospital, University of Ottawa, 501 Smyth Road, Ottawa, ON K1H 8L6, Canada
1 shared publication
Latest Publications
- Open Access
Does Physeal Preservation Matter? Patient-Reported Outcomes After Physeal-Sparing Versus Transphyseal Anterior Cruciate Ligament (ACL) Reconstruction in Pediatric Patients: A Systematic Review and Meta-Analysis
Background/Objectives: ACL injuries in skeletally immature patients present a unique surgical challenge, with ongoing debate regarding the optimal reconstruction technique relative to the open physis. Methods: A systematic review and meta-analysis were conducted following PRISMA guidelines, searching PubMed/MEDLINE, Cochrane Library, and Google Scholar. Twenty-two studies (n = 1036 patients; 598 physeal-sparing, 438 transphyseal) were included. The evidence base consisted predominantly of non-randomized retrospective studies. Patient-reported outcomes, return-to-sport rates, growth disturbances, graft failure, and reoperation rates were pooled using a random-effects model. Results: Pooled IKDC scores were 95.14 (95% CI: 93.81–96.50) for physeal-sparing and 96.17 (95% CI: 93.98–98.42) for transphyseal reconstruction, with no significant between-group difference (p = 0.436). Lysholm scores were 95.56 versus 93.04 (p = 0.075), and Tegner scores were 6.39 versus 7.08 (p = 0.366), respectively, with no statistically significant differences. KOOSs also showed no significant difference (96.19 vs. 96.00; p = 0.948). The pooled return-to-sport rate was higher following transphyseal reconstruction than physeal-sparing reconstruction (97.8% vs. 93.9%; p = 0.034). Growth disturbances were more frequently reported in the physeal-sparing group (5.1% vs. 1.4%; p = 0.008). Graft failure (5.8% vs. 8.4%; p = 0.144) and reoperation rates (13.5% vs. 13.8%; p = 0.906) were comparable between techniques. Conclusions: Both techniques yielded comparable functional outcomes across major PROMs. Transphyseal reconstruction was associated with a higher pooled return-to-sport rate in the included studies, whereas physeal-sparing reconstruction was associated with a higher incidence of reported growth disturbances. However, these findings should be interpreted cautiously given that the evidence base consisted predominantly of non-randomized retrospective studies and was subject to potential confounding and other sources of bias.
Open AccessDoes Physeal Preservation Matter? Patient-Reported Outcomes After Physeal-Sparing Versus Transphyseal Anterior Cruciate Ligament (ACL) Reconstruction in Pediatric Patients: A Systematic Review and Meta-Analysis
Background/Objectives: ACL injuries in skeletally immature patients present a unique surgical challenge, with ongoing debate regarding the optimal reconstruction technique relative to the open physis. Methods: A systematic review and meta-analysis were conducted following PRISMA guidelines, searching PubMed/MEDLINE, Cochrane Library, and Google Scholar. Twenty-two studies (n = 1036 patients; 598 physeal-sparing, 438 transphyseal) were included. The evidence base consisted predominantly of non-randomized retrospective studies. Patient-reported outcomes, return-to-sport rates, growth disturbances, graft failure, and reoperation rates were pooled using a random-effects model. Results: Pooled IKDC scores were 95.14 (95% CI: 93.81–96.50) for physeal-sparing and 96.17 (95% CI: 93.98–98.42) for transphyseal reconstruction, with no significant between-group difference (p = 0.436). Lysholm scores were 95.56 versus 93.04 (p = 0.075), and Tegner scores were 6.39 versus 7.08 (p = 0.366), respectively, with no statistically significant differences. KOOSs also showed no significant difference (96.19 vs. 96.00; p = 0.948). The pooled return-to-sport rate was higher following transphyseal reconstruction than physeal-sparing reconstruction (97.8% vs. 93.9%; p = 0.034). Growth disturbances were more frequently reported in the physeal-sparing group (5.1% vs. 1.4%; p = 0.008). Graft failure (5.8% vs. 8.4%; p = 0.144) and reoperation rates (13.5% vs. 13.8%; p = 0.906) were comparable between techniques. Conclusions: Both techniques yielded comparable functional outcomes across major PROMs. Transphyseal reconstruction was associated with a higher pooled return-to-sport rate in the included studies, whereas physeal-sparing reconstruction was associated with a higher incidence of reported growth disturbances. However, these findings should be interpreted cautiously given that the evidence base consisted predominantly of non-randomized retrospective studies and was subject to potential confounding and other sources of bias.
- Open Access
- 22 May 2025
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 9 (6)
Minimally-Invasive Dega Osteotomy in Ambulatory Pediatric Patients With Residual Developmental Dysplasia of the Hips—A Technique and Prospective Case Series
Purpose: This study describes the minimally invasive Dega osteotomy for treating residual acetabular dysplasia in ambulatory pediatric patients. The focus is on assessing the safety, feasibility, and early outcomes of this minimally invasive technique. Methods: A prospective series was conducted in a single tertiary orthopaedic center. The procedure involved an initial examination of hip joint stability using intraoperative arthrography. The surgical procedure involved a small transverse incision distal and lateral to the anterior superior iliac spine, followed by a Dega osteotomy and bone allografting. Variables such as surgical time, blood loss, incision length, and acetabular index were measured. Results: In healthy ambulatory patients, 16 osteotomies were performed on 12 patients with an average age of 32 months. The mean incision length was 2.3 cm, average blood loss was 17 mL, and mean surgical time was 21 minutes per side. Preoperative and postoperative acetabular indices averaged 40.3° and 18.6°, respectively. The mean follow-up period was 13 months. No complications were seen in this series. Conclusion: The minimally invasive Dega osteotomy technique is a safe and effective method for treating residual acetabular dysplasia in ambulatory patients. It offers advantages of minimal invasiveness, reduced surgical time, and less blood loss, with outcomes comparable to standard methods. However, further studies with larger cohorts and longer follow-up are necessary to fully establish its efficacy and safety profile.
- 22 May 2025
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 9 (6)
Open AccessMinimally-Invasive Dega Osteotomy in Ambulatory Pediatric Patients With Residual Developmental Dysplasia of the Hips—A Technique and Prospective Case Series
Purpose: This study describes the minimally invasive Dega osteotomy for treating residual acetabular dysplasia in ambulatory pediatric patients. The focus is on assessing the safety, feasibility, and early outcomes of this minimally invasive technique. Methods: A prospective series was conducted in a single tertiary orthopaedic center. The procedure involved an initial examination of hip joint stability using intraoperative arthrography. The surgical procedure involved a small transverse incision distal and lateral to the anterior superior iliac spine, followed by a Dega osteotomy and bone allografting. Variables such as surgical time, blood loss, incision length, and acetabular index were measured. Results: In healthy ambulatory patients, 16 osteotomies were performed on 12 patients with an average age of 32 months. The mean incision length was 2.3 cm, average blood loss was 17 mL, and mean surgical time was 21 minutes per side. Preoperative and postoperative acetabular indices averaged 40.3° and 18.6°, respectively. The mean follow-up period was 13 months. No complications were seen in this series. Conclusion: The minimally invasive Dega osteotomy technique is a safe and effective method for treating residual acetabular dysplasia in ambulatory patients. It offers advantages of minimal invasiveness, reduced surgical time, and less blood loss, with outcomes comparable to standard methods. However, further studies with larger cohorts and longer follow-up are necessary to fully establish its efficacy and safety profile.
- Open Access
- 22 June 2021
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 41 (7) , e533-e539
Efficacy of Percutaneous Retrograde Transphyseal Guided Growth Screw in Distal Femoral Angular Deformity Correction: A New Technique
Background: We modified the original technique for percutaneous transphyseal screw which was described in 1998 by Metaizeau and colleagues for distal femoral coronal angular deformity correction; the modification is related to the screw direction, whereas the screw is administered in a retrograde pattern, starting from the epiphysis and directed toward the metaphysis. This technique opposes the original technique that was started with a metaphyseal entry point which aimed toward the epiphysis. This study evaluates the efficacy of the newly suggested surgical technique regarding the rate of correction and growth resumption after screw removal. Methods: This prospective study looked at 40 patients (65 distal femoral physes), who underwent a percutaneous retrograde transphyseal guided growth screw procedure, from October 2017 to September 2019. All the patients included had distal femoral coronal angular deformities; 52 in valgus and 13 in varus deformities. The study included 17 females with an average age of 11.75 (range: 8.4 to 14.5 y) for 29 femurs and 23 males with an average age of 13.75 (range: 11.75 to 15.6 y) for 36 femurs. The mechanical lateral distal femoral angle was measured initially, and then again was measured after reaching the desired corrected orientation. The patients were then followed up after the screw removal and followed up to maturity, if the physis had continued to grow postcorrection. The degree of correction per month was calculated, and the consequence of screw removal was detected. Follow-up average time was 12.6 months (range: 30 to 6 mo). Results: The average correction in the distal femur was 1.3 degrees per month (range: 0.5 to 1.857 degrees/mo). In all of the 65 segments (61 femurs had significant growth remaining and 4 femurs had reached skeletal maturity with suboptimal mechanical lateral distal femoral angle correction), the screws were removed at the time of angular correction. Rebound growth was observed in 15 physes with an average of 1.8 degrees (range: 2 to 3 degrees); they were stable in 42 physes and progressed in 4 physes with an average of 1.6 degrees (range: 1 to 2 degrees). Complications were minor and related to entrapment of soft tissue under the screw washer. Conclusion: Percutaneous retrograde transphyseal guided growth screw for distal femur coronal angular deformity is a minimally invasive procedure, with a statistically significant correction rate when compared with the original transphyseal screw technique. The new technique has proven to have growth resumption after screw removal with minimal complication risk. Level of Evidence: Level III—prospective observational study.
- 22 June 2021
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 41 (7) , e533-e539
Open AccessEfficacy of Percutaneous Retrograde Transphyseal Guided Growth Screw in Distal Femoral Angular Deformity Correction: A New Technique
Background: We modified the original technique for percutaneous transphyseal screw which was described in 1998 by Metaizeau and colleagues for distal femoral coronal angular deformity correction; the modification is related to the screw direction, whereas the screw is administered in a retrograde pattern, starting from the epiphysis and directed toward the metaphysis. This technique opposes the original technique that was started with a metaphyseal entry point which aimed toward the epiphysis. This study evaluates the efficacy of the newly suggested surgical technique regarding the rate of correction and growth resumption after screw removal. Methods: This prospective study looked at 40 patients (65 distal femoral physes), who underwent a percutaneous retrograde transphyseal guided growth screw procedure, from October 2017 to September 2019. All the patients included had distal femoral coronal angular deformities; 52 in valgus and 13 in varus deformities. The study included 17 females with an average age of 11.75 (range: 8.4 to 14.5 y) for 29 femurs and 23 males with an average age of 13.75 (range: 11.75 to 15.6 y) for 36 femurs. The mechanical lateral distal femoral angle was measured initially, and then again was measured after reaching the desired corrected orientation. The patients were then followed up after the screw removal and followed up to maturity, if the physis had continued to grow postcorrection. The degree of correction per month was calculated, and the consequence of screw removal was detected. Follow-up average time was 12.6 months (range: 30 to 6 mo). Results: The average correction in the distal femur was 1.3 degrees per month (range: 0.5 to 1.857 degrees/mo). In all of the 65 segments (61 femurs had significant growth remaining and 4 femurs had reached skeletal maturity with suboptimal mechanical lateral distal femoral angle correction), the screws were removed at the time of angular correction. Rebound growth was observed in 15 physes with an average of 1.8 degrees (range: 2 to 3 degrees); they were stable in 42 physes and progressed in 4 physes with an average of 1.6 degrees (range: 1 to 2 degrees). Complications were minor and related to entrapment of soft tissue under the screw washer. Conclusion: Percutaneous retrograde transphyseal guided growth screw for distal femur coronal angular deformity is a minimally invasive procedure, with a statistically significant correction rate when compared with the original transphyseal screw technique. The new technique has proven to have growth resumption after screw removal with minimal complication risk. Level of Evidence: Level III—prospective observational study.