Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Linxiao Cong has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Temperature Drift Compensation Using Multiscale Feature Extraction-Based LSTM Network for Micro-Thrust Measurement

    by Ronghui Qian, Xingyu Chen, Jianfei Long, Bin Wang, Jiahao Cao, Linxiao Cong, Liye Zhao, Ning Guo, Jiawen Xu, Ruqiang Yan

    Micro-thrust measurement systems play a crucial role in high-precision space missions, but their performance is significantly affected by thermal drift interference caused by temperature fluctuations. This study reveals that low-frequency components of drift exhibit strong correlation with temperature variations, while high-frequency components are minimally affected. Additionally, the 3-D temperature distribution influences drift in a multiscale manner. By applying variational mode decomposition (VMD) and correlation analysis to both thermal displacement and temperature signals, we successfully extracted drift components highly correlated with temperature. A novel temperature drift compensation method based on multiscale feature extraction and long short-term memory networks network was then developed and validated. The results demonstrate that the proposed method reduces the amplitude spectral density of the drift signal at 0.1 mHz by 12.67 times in a standard laboratory environment and 46.15 times in a vacuum chamber with vibration isolation, achieving a minimum drift of 0.39 $\bm{\mu} \mathbf{N}/\sqrt{\mathbf{H}\mathbf{z}}$ at 0.1 mHz. This approach significantly enhances system stability and measurement accuracy.


  • Open Access

    Ultra-sensitive Inclinometer via Critical Coupling of a Gravitational Compound Pendulum for Nanoradian Tilt Measurement

    by Jianfei Long, Ying Wang, Linxiao Cong, Jiawen Xu, Mingshan Wu, Weijie Zhou, Jiabin Wang, Yelong Zheng, Bin Wang, Hong Zhang, et al.

    Accurate monitoring of the horizontal tilt is essential to suppress low-frequency noise in the measurement system of micro-thrust—a requirement for spacebased gravitational wave measurements. Unfortunately, the sensitivity of modern inclinometers is fundamentally limited by the noise floors of their physical and electronic components.To overcome these limitations is a new inclinometer design which consists of a gravitational compound pendulum and a displacement sensor that reach ultrahigh sensitivity. Our inclinometer implements a mechanical amplification mode of a quasi-zero stiffness system.By critically coupling the pendulum’s gravitational restoring moment with the stiffness of a flexure pivot, the system efficiently transforms minute tilt angles into measurable displacements. Theoretical modelling clarifies the mechanics of this angular amplification and guides our strategy for regulating the gravitational restoring moment.Experimental characterization demonstrates a resolution of 0.87 nrad over a 0–109 µrad range, the tunable amplification factor can be increased to exceeding 160 and the nonlinearity error as low as 1.18%. This compact and versatile design provides a strong motivation to deploy ultra-precision tilt measurement on advanced metrology and adaptive devices.

  • A Novel Closed-Loop Dynamic Micro-Thrust Measurement Method Based on Torsion Pendulum

    by Jiabin Wang, Jianfei Long, Xiaolei Wang, Ying Wang, Sujin Ji, Jianming Liang, Jiawen Xu, Mingshan Wu, Linxiao Cong, Luxiang Xu, et al.

    This study introduces a new closed-loop dynamic micro-thrust measurement method based on torsional pendulum is proposed, addressing the poor real-time performance and insufficient precision inherent in traditional open-loop techniques that rely on extreme displacement values to estimate thrust. This method achieves PID closed-loop control through electromagnetic force compensation, tracking the thrust to be measured in real-time. The measurement results are directly inverted from the compensation force. Experimental results show that the dynamic thrust of the electromagnetic calibration system within 0.8 Hz is highly consistent with the calibration results of a high-precision balance with R2 = 0.99895. In closed-loop mode, the phase lag for 20 μN dynamic thrust measurement is only 0.5425°, with a root mean square error as low as 1.82%. The system’s expanded uncertainty is 1.79% below the intrinsic frequency of 11.57 mHz, providing a reliable ground-based verification solution for spacecraft drag-free control and high-frequency dynamic thrust measurement.


  • Open Access

    Research on Ground Vibration and Isolation Methods in Dynamic Micro-Thrust Measurement

    by Linxiao Cong, Haoye Deng, Hao Liu, Jiabin Wang, Chunyuan Zhu, Jianchao Mu, Zhan Hu, Bin Wang, Jianfei Long, Congfeng Qiao

    In the field of dynamic microthrust measurement, ground vibration noise poses a particularly complex and formidable challenge, significantly disrupting measurement accuracy, especially in dynamic scenarios. This paper proposes a negative stiffness isolation method based on a compliant parallel mechanism, aiming to mitigate torsional vibration noise caused by ground lateral or angular vibrations. This approach enhances the dynamic resolution of thrust measurement to 0.1 μN. The transfer matrix method is employed to systematically analyze the dynamic behavior of a multi-stage vibration isolation system, establishing the input-output force and displacement relationships across isolation stages for a quantitative evaluation of vibration transmission characteristics. Additionally, the paper addresses low-frequency compensation, where gravity and other factors can affect the system’s steady-state performance. Differential measurement using symmetrically placed torsion pendulums is introduced to reduce the impact of low-frequency drift on system performance. Through in-depth theoretical modeling and extensive simulation experiments, the dynamic characteristics of the system, multi-stage vibration isolation strategies, and the vibration isolation effects under various working conditions are comprehensively explored. This validates the effectiveness of the proposed integrated approach in isolating high-frequency dynamic responses and achieving precise vibration isolation across the frequency range from 0.01 Hz to 10 Hz.

  • Nanonewton-level Thrust Measurement Based on Stiffness Adjustment Through Total Variation Denoising Under Heavy Loads

    by Jiabin Wang, Jianfei Long, Jiawen Xu, Mingshan Wu, Linxiao Cong, Luxiang Xu, Yelong Zheng, Bin Wang, Ning Guo

    Sub-micro-Newton thrusters on space satellites are widely used in spaceborne gravitational wave detection, making accurate measurement of micro-thrust-generated thrust essential. Moreover, micro-propulsion systems often exhibit substantial mass, posing challenges for thrust measurement. This research prompted the development of a sub-micro-thrust measurement device based on the inverted pendulum principle, which with-stands 8 kg loads and boasts a large thrust-to-weight ratio exceeding 109. Experimental results demonstrate that adjusting the stiffness of the inverted pendulum can effectively enhance the resolution of the device. Piecewise constant signal (PCS) thrust force was introduced, and the nonlinear total variation denoising (TVD) algorithm method was adopted for signal denoising. It is validated that thrust measurement in the range of 0–261 μN is achieved with a minimum resolution of 24 nN. The device design and stiffness adjustment method proposed in this paper, as well as the data denoising method utilized, greatly enhance the thrust resolution measurement. This approach enables the development of an accurate micro-thrust model for spaceborne gravitational wave detection missions while simultaneously offering a novel solution for sub-micro-newton-level thrust measurement under heavy load conditions.


  • Coupling operation characterization of the Hall micro thruster with a thermal emission cathode with a grid

    by Shixu Lu, Liexiao Dong, Ning Guo, Luxiang Xu, Linxiao Cong, Jian Wang, Shengtao Liang, Jianfei Long

  • Open Access

    Microgravity Decoupling in Torsion Pendulum for Enhanced Micro-Newton Thrust Measurement

    by Linxiao Cong, Jiabin Wang, Jianfei Long, Jianchao Mu, Haoye Deng, Congfeng Qiao

    To enhance the accuracy of micro-Newton thrust measurements via a torsion pendulum, addressing microgravity coupling effects caused by platform tilt and pendulum mass eccentricity is crucial. This study focuses on analyzing and minimizing these effects by alleviating reference surface tilt and calibrating the center of mass during thrust measurements. The study introduced analysis techniques and compensation measures. It first examined the impact of reference tilt and center of mass eccentricity on the stiffness and compliance of the torsion pendulum by reconstructing its dynamic model. Simscape Multibody was initially employed for numerical analysis to assess the dynamic coupling effects of the tilted pendulum. The results showed the influence of reference tilt on the stiffness and compliance of the torsion pendulum through simulation. An inverted pendulum was developed to amplify the platform’s tilt angle for microgravity drag-free control. Center of mass calibration can identify the gravity coupling caused by the center of mass position. Based on the displacement signal from the capacitive sensor located at the end of the inverted pendulum, which represents the platform’s tilt angle, the pendulum’s vibration at 0.1 mHz was reduced from 5.7 μm/Hz1/2 to 0.28 μm/Hz1/2 by adjusting the voltage of piezoelectric actuator. Finally, a new two-stage torsion pendulum structure was proposed to decouple the tilt coupling buried in both pitch and roll angle. The study utilized theoretical models, numerical analysis, and experimental testing to validate the analysis methods and compensation measures for microgravity coupling effects in torsion pendulums. This led to a reduction in low-frequency noise caused by ground vibrations and thermal strains, ultimately improving the micro-Newton thrust measurement accuracy of the torsion pendulum through the platform’s drag-free control.


  • Micro-Newton Thrust Stand Calibration Using Electrostatic Lantern Rings

    by Jianchao Mu, Linxiao Cong, Qiwei Hu, Congfeng Qiao

    Numerical research on an electrostatic lantern rings calibration structure is conducted to produce an electrostatic driving force in the range of 0-2.25 mN. The driving force is the electrostatic attraction generated when a potential difference is applied between a set of oppositely arranged lantern rings. The electrostatic potential, electric field distribution, and force generated at different voltages are obtained. Due to the axial symmetry of electrostatic lantern rings, the radial electrostatic force component is balanced and the electrostatic force mainly acts in the axial direction. When the engagement distance of the rings is within 3-6 mm, the deflection angle does not exceed 2°, or the radial offset does not exceed 0.3 mm, the electrostatic force deviation is less than 5%. Electrostatic lantern rings provide an accurate and practical alternative method for thrust stand calibration.


  • Open Access

    Thermal Noise Decoupling of Micro-Newton Thrust Measured in a Torsion Balance

    by Linxiao Cong, Jianchao Mu, Qian Liu, Hao Wang, Linlin Wang, Yonggui Li, Congfeng Qiao

    The space gravitational wave detection and drag free control requires the micro-thruster to have ultra-low thrust noise within 0.1 mHz–0.1 Hz, which brings a great challenge to calibration on the ground because it is impossible to shield any spurious couplings due to the asymmetry of torsion balance. Most thrusters dissipate heat during the test, making the rotation axis tilt and components undergo thermal drift, which is hysteretic and asymmetric for micro-Newton thrust measurement. With reference to LISA’s research and coming up with ideas inspired from proportional-integral-derivative (PID) control and multi-timescale (MTS), this paper proposes to expand the state space of temperature to be applied on the thrust prediction based on fine tree regression (FTR) and to subtract the thermal noise filtered by transfer function fitted with z-domain vector fitting (ZDVF). The results show that thrust variation of diurnal asymmetry in temperature is decoupled from 24 μN/Hz1/2 to 4.9 μN/Hz1/2 at 0.11 mHz. Additionally, 1 μN square wave modulation of electrostatic force is extracted from the ambiguous thermal drift background of positive temperature coefficient (PTC) heater. The PID-FTR validation is performed with experimental data in thermal noise decoupling, which can guide the design of thermal control and be extended to other physical quantities for noise decoupling.


  • Open Access

    Thermal Noise Decoupling of Micro-Newton Thrust Measured in a Torsion Balance

    by Lin-Xiao Cong, Jian-Chao Mu, Qian Liu, Hao Wang, Lin-Lin Wang, Yong-Gui Li, Cong-Feng Qiao

    The space gravitational wave detection and drag free control requires the micro-thruster to have very low thrust noise within 0.1mHz~100mHz, which poses a great challenge to the ground thrust test. The evaluation and decoupling of thermal noise are the difficulties in the application of torsion balance for most thrusters dissipate heat in the experiment. The research has adopted a calibration scheme of micro-Newton thrust torsion balance. On the basis of Lisa Pathfinder's former research and using ideas inspired from PID control and multi time scale (MTS) for reference, the paper proposes to expand the state space of temperature to be applied on thrust prediction based on fine tree regression (FTR), to subtract the thermal noise filtered by transfer function fitted with z-domain vector fitting (ZDVF). The results show that the thrust amplitude thrust density in diurnal temperature fluctuation is decoupled from 24μN/Hz1/2 to 4.9μN/Hz1/2 at 0.11mHz. And the 1μN square wave modulations of electrostatic fins (ESF) is extracted from the simultaneously ambiguous background of temperature for PTC's heating and cooling. The FTR method is well demonstrated in thermal noise decoupling and can guide the design of thermal control and be extended to other physical quantities for noise decoupling.