YLYung-Tsai Lee

Yung-Tsai Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yung-Tsai Lee has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Shifting From Anatomical to Functional Abnormalities

    by Yung-Tsai Lee, Wei-Hsian Yin

  • Deep learning versus radiologists for acute aortic dissection on CT: A systematic review and network meta-analysis

    by Ting-Wei Wang, Jia-Sheng Hong, Ho-Ren Liu, Kuan-Ting Wu, Hao-Neng Fu, Yung-Tsai Lee, Po-Hsiang Liao, Guan-Hua Huang, I-Ming Chen, Wei-Hsian Yin, et al.

  • Open Access

    Automated Aortic Quantification Based on Artificial Intelligence: Validation Using Contrast-Enhanced and Non-Contrast CT Scans from the Same Session

    by Jia-Sheng Hong, Yun-Hsuan Tzeng, Kuan-Ting Wu, Shih-Yu Huang, Ting-Wei Wang, Guan-Yu Li, Chun-Yi Lin, Ho-Ren Liu, Hai-Neng Fu, Yung-Tsai Lee, et al.

    Early detection of aortic dilatation is clinically important for preventing progression to serious aortic disease and enabling timely intervention. We aimed to develop an AI method for quantifying the aorta in both contrast-enhanced and non-contrast CT scans, assisting early detection of aortic dilation. A total of 190 patient cases were analyzed, each having paired contrast-enhanced and non-contrast CT scans acquired in the same session, resulting in 380 scans. Our approach, based on open-source tools, demonstrated strong agreement with manual annotations, particularly in the ascending aorta. For contrast-enhanced CT, the AI achieved a correlation coefficient of 0.987 and intraclass correlation coefficient (ICC) of 0.986; for non-contrast CT, both were 0.945. Compared with clinical records, the sensitivity of AI detection was 97% for contrast-enhanced CT and 94% for non-contrast CT. This AI-based workflow enables highly sensitive automated aortic quantification in both contrast-enhanced and non-contrast CT scans, supporting broader clinical applicability across different imaging conditions.

  • Open Access

    Automated Aortic Quantification Based on Artificial Intelligence: Validation Using Contrast-Enhanced and Non-Contrast CT Scans from the Same Session

    by Jia-Sheng Hong, Yun-Hsuan Tzeng, Kuan-Ting Wu, Shih-Yu Huang, Ting Wei Wang, Guan-Yu Li, Chun-Yi Lin, Ho-Ren Liu, Hai-Neng Fu, Yung-Tsai Lee, et al.

    Artificial intelligence (AI) advancements have enabled automated aortic quantification in computed tomography (CT) imaging. We aimed to develop an AI method for quantifying the aorta in both contrast-enhanced and non-contrast CT scans, assisting early detection of aortic dilation. A total of 190 patient cases were analyzed, each having paired con-trast-enhanced and non-contrast CT scans acquired in the same session, resulting in 380 scans. Our approach, based on open-source tools, demonstrated strong agreement with manual annotations, particularly in the ascending aorta. For contrast-enhanced CT, the AI achieved a correlation coefficient of 0.987 and intraclass correlation coefficient (ICC) of 0.986; for non-contrast CT, both were 0.945. Compared with clinical records, the sensi-tivity of AI detection was 97% for contrast-enhanced CT and 94% for non-contrast CT. This AI-based approach offers highly sensitive, automated aortic quantification across contrast conditions, supporting physicians in early identification of aortic abnormalities.

  • Open Access

    Artificial Intelligence-Enabled Electrocardiography for Preoperatively Detecting Atrial Fibrillation and Mortality Risk in Patients with Sinus Rhythm

    by Chiao-Chin Lee, Chin-Sheng Lin, Wen-Yu Lin, Chiao-Hsiang Chang, Wei-Ting Liu, Dung-Jang Tsai, Cheng-Chung Cheng, Jun-Ting Liou, Wei-Shiang Lin, Tien-Ping Tsao, et al.

    Background: Pre-existing atrial fibrillation (AF) and postoperative new-onset AF (NOAF) are independent perioperative risk factors associated with increased short-term mortality and adverse events. This study aimed to develop and validate an artificial intelligence (AI) model capable of detecting hidden AF, including both pre-existing AF and NOAF, from sinus rhythm electrocardiograms, to improve perioperative risks assessment.


  • Open Access

    Real-world application of deep learning for ECG-based prediction of coronary artery disease and revascularization needs

    by Chiao-Hsiang Chang, Chin-Sheng Lin, Chun-Ho Lee, Chin Lin, Chiao-Chin Lee, Wei-Ting Liu, Yung-Tsai Lee, Dung-Jang Tsai

    Aims: Early detection of the need for coronary revascularization and timely intervention may reduce fatal events, but limited screening tools often leads to underdiagnosis. The aim of this study is to use a deep learning model (DLM) that utilizes electrocardiography (ECG) and the eXtreme Gradient Boosting (XGBoost) model to predict risk of coronary revascularization in the general population. Methods and results: This study included patients with at least one ECG per patient. The development set comprised 113 451 patients for training a DLM. After excluding patients with elevated troponin I levels and those without follow-up records, the internal validation set consisted of 66 680 patients. The external validation was conducted using data from a community hospital. XGBoost predicted events based on demographic data and ECG features. The primary endpoint was coronary revascularization within 1 year. Model performance was evaluated using the C-index. The DLM stratified patients by risk of coronary revascularization within 1 year. The study included 51% males with a mean age of 53 years, 10% with diabetes, and a revascularization rate of 2.6%. High-risk patients had a hazard ratio of 9.77 (95% CI: 7.63–12.51) compared with low-risk patients. The C-index was 0.825 (95% CI: 0.81–0.84). Combining demographic and AI-ECG data, XGBoost achieved a C-index of 0.884 (95% CI: 0.87–0.89). Comparative C-index analysis revealed significantly different discriminative performance between models (P = 1.110223e−15). Conclusions: The DLM demonstrates ECG's potential as a screening tool for coronary revascularization, enabling opportunistic detection and prompting further evaluation of high-risk patients.


  • The role of deep learning in aortic aneurysm segmentation and detection from CT scans: A systematic review and meta-analysis

    by Ting-Wei Wang, Yun-Hsuan Tzeng, Jia-Sheng Hong, Ho-Ren Liu, Hao-Neng Fu, Yung-Tsai Lee, Wei-Hsian Yin, Yu-Te Wu


  • Integrating VAI-Assisted Quantified CXRs and Multimodal Data to Assess the Risk of Mortality

    by Yu-Cheng Chen, Wen-Hui Fang, Chin-Sheng Lin, Dung-Jang Tsai, Chih-Wei Hsiang, Cheng-Kuang Chang, Kai-Hsiung Ko, Guo-Shu Huang, Yung-Tsai Lee

    To address the unmet need for a widely available examination for mortality prediction, this study developed a foundation visual artificial intelligence (VAI) to enhance mortality risk stratification using chest X-rays (CXRs). The VAI employed deep learning to extract CXR features and a Cox proportional hazard model to generate a hazard score (“CXR-risk”). We retrospectively collected CXRs from patients visited outpatient department and physical examination center. Subsequently, we reviewed mortality and morbidity outcomes from electronic medical records. The dataset consisted of 41,945, 10,492, 31,707, and 4441 patients in the training, validation, internal test, and external test sets, respectively. During the median follow-up of 3.2 (IQR, 1.2–6.1) years of both internal and external test sets, the “CXR-risk” demonstrated C-indexes of 0.859 (95% confidence interval (CI), 0.851–0.867) and 0.870 (95% CI, 0.844–0.896), respectively. Patients with high “CXR-risk,” above 85th percentile, had a significantly higher risk of mortality than those with low risk, below 50th percentile. The addition of clinical and laboratory data and radiographic report further improved the predictive accuracy, resulting in C-indexes of 0.888 and 0.900. The VAI can provide accurate predictions of mortality and morbidity outcomes using just a single CXR, and it can complement other risk prediction indicators to assist physicians in assessing patient risk more effectively.


  • Meta-analysis of deep learning approaches for automated coronary artery calcium scoring: Performance and clinical utility AI in CAC scoring: A meta-analysis

    by Ting-Wei Wang, Yun-Hsuan Tzeng, Kuan-Ting Wu, Ho-Ren Liu, Jia-Sheng Hong, Huan-Yu Hsu, Hao-Neng Fu, Yung-Tsai Lee, Wei-Hsian Yin, Yu-Te Wu


  • Open Access

    Comprehensive clinical application analysis of artificial intelligence-enabled electrocardiograms for screening multiple valvular heart diseases

    by Yu-Ting Lin, Chin-Sheng Lin, Chien-Sung Tsai, Dung-Jang Tsai, Yu-Sheng Lou, Wen-Hui Fang, Yung-Tsai Lee, Chin Lin

    Background: Valvular heart disease (VHD) is becoming increasingly important to manage the risk of future complications. Electrocardiographic (ECG) changes may be related to multiple VHDs, and (AI)-enabled ECG has been able to detect some VHDs. We aimed to develop five deep learning models (DLMs) to identify aortic stenosis, aortic regurgitation, pulmonary regurgitation, tricuspid regurgitation, and mitral regurgitation. Methods: Between 2010 and 2021, 77,047 patients with echocardiography and 12-lead ECG performed within 7 days were identified from an academic medical center to provide DLM development (122,728 ECGs), and internal validation (7,637 ECGs). Additional 11,800 patients from a community hospital were identified to external validation. The ECGs were classified as with or without moderate-to-severe VHDs according to transthoracic echocardiography (TTE) records, and we also collected the other echocardiographic data and follow-up TTE records to identify new-onset valvular heart diseases. Results: AI-ECG adjusted for age and sex achieved areas under the curves (AUCs) of >0.84, >0.80, >0.77, >0.83, and >0.81 for detecting aortic stenosis, aortic regurgitation, pulmonary regurgitation, tricuspid regurgitation, and mitral regurgitation, respectively. Since predictions of each DLM shared similar components of ECG rhythms, the positive findings of each DLM were highly correlated with other valvular heart diseases. Of note, a total of 37.5–51.7% of false-positive predictions had at least one significant echocardiographic finding, which may lead to a significantly higher risk of future moderate-to-severe VHDs in patients with initially minimal-to-mild VHDs. Conclusion: AI-ECG may be used as a large-scale screening tool for detecting VHDs and a basis to undergo an echocardiography.