MBMike Reis Bueno

Mike Reis Bueno

*This is an algorithmically generated author record based on publicly available information.

Mike Reis Bueno has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Incidental Findings Following Dental Implant Procedures in the Mandible: A New Post-Processing CBCT Software Analysis

    by Marcel da Silva Garrote, Ana Helena Gonçalves de Alencar, Cyntia Rodrigues de Araújo Estrela, Lucas Rodrigues de Araújo Estrela, Mike Reis Bueno, Orlando Aguirre Guedes, Carlos Estrela

    Background/Objectives: The aim of this study was to evaluate incidental findings in the mandible after the placement of dental implants using a new cone–beam computed tomography (CBCT) software. Methods: The initial sample consisted of 2872 CBCT scans of patients of both sexes. The parameters evaluated in this study were the location of the implants in the mandible, implant length, anatomical relationship of the implant with the mandibular canal, presence or absence of damage to the adjacent teeth, presence or absence of implant fractures, and presence or absence of bone support. Fisher’s exact test was performed to compare the variables. The significance level was set at p = 0.05. Results: Out of 2872 CBCT scans, 214 images of patients with an average age of 44.5 years were included. The most frequent location of the implants was the posterior region (93.5%), with 54% of the implants having a length between 9 and 14 mm. It was found that 92% of the implants were positioned above the mandibular canal. Damage to adjacent teeth was observed, with no correlation with the implant positioning (p = 1.000). In 100% of cases of implants in the anterior region, there was bone support. Fracture was observed in 1.7% of implants with a length between 9 and 14 mm. Conclusions: The installation of implants in the mandible occurs more frequently in the posterior region, with a high presence of bone support and a low incidence of damage to adjacent teeth, anatomical structures, and fractures.


  • Open Access

    Incidental Findings Following Dental Implants Procedures in Mandible: A New Post-processing CBCT Software Analysis

    by Marcel da Silva Garrote, Ana Helena Gonçalves de Alencar, Cyntia Rodrigues de Araújo Estrela, Lucas Rodrigues de Araújo Estrela, Mike Reis Bueno, Orlando Aguirre Guedes, Carlos Estrela

    Background/Objectives: To evaluate incidental findings in the mandible after the placement of dental implants using a new cone-beam computed tomography (CBCT) software. Methods: The initial sample consisted of 2,872 CBCT scans of patients of both sexes. The parameters evaluated in this study were the location of the implants in the mandible, implant length, anatomical relationship of the implant with the mandibular canal, presence or absence of damage to the adjacent teeth, presence or absence of implant fractures, and presence or absence of bone support. Fisher's exact test was performed to compare the variables. The significance level was set at p = 0.05. Results: Out of 2,872 CBCT scans, 214 images of patients with an average age of 44.5 years were included. The most frequent location of the implants was the posterior region (93.5%), with 54% of the implants having a length between 9 and 14 mm. It was found that 92% of the implants were positioned above the mandibular canal. Three damage to adjacent teeth was observed, with no correlation with the implant positioning (p = 0.999). In 100% of cases of implants in the anterior region, there was bone support. Fracture was observed in 1.7% of implants with a length between 9- and 14-mm. Conclusions: The installation of implants in the mandible occurs more frequently in the posterior region, with a high presence of bone support and a low incidence of damage to adjacent teeth, anatomical structures, and fractures.


  • Open Access

    Spatial Position and Anatomical Characteristics Associated with Impacted Third Molars Using a Map-Reading Strategy on Cone-Beam Computed Tomography Scans: A Retrospective Analysis

    by Djalma Maciel de Lima, Cyntia Rodrigues de Araújo Estrela, Cristiane Martins Rodrigues Bernardes, Lucas Rodrigues de Araújo Estrela, Mike Reis Bueno, Carlos Estrela

    (1) Background: This study assessed the spatial position and anatomical features associated with impacted third molars through a map-reading strategy employing cone-beam computed tomography (CBCT). (2) Methods: The positioning of impacted third molars on CBCT was assessed using Winter’s and Pell and Gregory’s classifications. External root resorption in mandibular second molars was categorized according to Herman’s classification. Additionally, the relationship between the mandibular third molar root apex and the mandibular canal was examined. Comparative statistical analysis was conducted using Fisher’s exact test, with a significance level considered as 5%. (3) Results: The results indicated that, based on Winter’s classification, 48.06 % of impacted teeth were positioned mesioangularly. Employing Pell and Gregory’s classification, 43.22% of the impacted molars fell into positions B and C, with 54.2% classified as Class II. A notable 69.7% of teeth exhibited no contact between the root apex and the mandibular canal, and external root resorption in the distal aspect of the second molar was absent in 88.7% of cases. (4) Conclusions: Utilizing the map-reading strategy with CBCT scans to assess the anatomical positions and characteristics of impacted third molars enhances professional confidence and sets a standard for quality and safety in the surgical procedure for patients.


  • Open Access

    Analysis of the Spatial Position and Anatomical Characteristics Related to Impacted Third Molars Using Map-Reading Strategy on CBCT Scans

    by Djalma Maciel de Lima, Cyntia Rodrigues de Araújo Estrela, Cristiane Martins Rodrigues Bernardes, Lucas Rodrigues de Araújo Estrela, Mike Reis Bueno, Carlos Estrela

    (1) Background: This study evaluated the spatial position and anatomical characteristics related to impacted third molars by map-reading strategy using cone beam computed tomography (CBCT). (2) Methods: To determine the positioning of impacted third molars on CBCT it was used Winter's and Pell & Gregory's classifications, and the presence of external root resorption in mandibular second molars were based on Herman´s classification. The relationship between the mandibular third molar root apex and the mandibular canal was also analyzed. Fisher’s exact test was used to comparative statistical analysis. The significance level considered was 5%. (3) Results: The results showed that according to Winter's classification, 48.06 % of impacted teeth were in the mesioangular position. Using Pell & Gregory's classification, 43.22% of the impacted molars were in the position B and C, and 54.2% of the teeth were class II. 69.7% of teeth showed an absence of contact between the root apex and the mandibular canal and there was no occurrence of external root resorption in the distal of second molar in 88.7%. (4) Conclusions: The map-reading strategy using CBCT scans for anatomical positions and characteristics of impacted third molars increases professional confidence and establishes a parameter of quality and safety in the surgical procedure for the patient.

  • Blooming artifact reduction using different cone-beam computed tomography software to analyze endodontically treated teeth with intracanal posts

    by Luiz Eduardo Gregoris Rabelo, Mike dos Reis Bueno, Marcus Vinícius Corrêa da Costa, Carlo Ralph de Musis, Cyntia Rodrigues de Araújo Estrela, Orlando Aguirre Guedes, Giulio Gavini, Carlos Estrela