Zhen Zhou
Zhen Zhou has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Weixiong Tan
Hangzhou Deepwise & League of PHD Technology Co., Ltd, Deepwise AI lab, Hangzhou City, Zhejiang Province, PR China (C.H., Z.Z., W.T., J.W.).
3 shared publications - Chang Sheng Zhou
Department of Radiology, Jinling Hospital, Medical School of Nanjing University, Nanjing, China
2 shared publications - Guangming Lu
Department of Radiology, Jinling Hospital, The First School of Clinical Medicine, Southern Medical University, 305 Zhongshan East Road, Nanjing, Jiangsu 210002, China
2 shared publications - Long Jiang Zhang
Department of Radiology, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China
2 shared publications Ainikaerjiang Aihemaiti
The First Affiliated Hospital of Xinjiang Medical University, Department of Radiology, Urumqi, Xinjiang Uygur Autonomous Region, PR China (P.T., H.H.K., W.Z., R.X., A.A., Y.S., Y.W.).
1 shared publicationBingyan Han
The Seventh Affiliated Hospital of Xinjiang Medical University, Department of Radiology, Urumqi, Xinjiang Uygur Autonomous Region, PR China (B.H., C.X., Y.C.).
1 shared publication
Latest Publications
- 13 June 2025
- Published by Elsevier in Academic Radiology
- Vol. 32 (9) , 5453-5467
Prediction of NIHSS Scores and Acute Ischemic Stroke Severity Using a Cross-attention Vision Transformer Model with Multimodal MRI
- 13 June 2025
- Published by Elsevier in Academic Radiology
- Vol. 32 (9) , 5453-5467
Prediction of NIHSS Scores and Acute Ischemic Stroke Severity Using a Cross-attention Vision Transformer Model with Multimodal MRI
- Open Access
- 3 June 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (7) , 1761-1772
Prediction of etiology and prognosis based on hematoma location of spontaneous intracerebral hemorrhage: a multicenter diagnostic study
Background: The location of the hemorrhagic of spontaneous intracerebral hemorrhage (sICH) is clinically pivotal for both identifying its etiology and prognosis, but comprehensive and quantitative modeling approach has yet to be thoroughly explored. Methods: We employed lesion-symptom mapping to extract the location features of sICH. We registered patients’ non-contrast computed tomography image and hematoma masks with standard human brain templates to identify specific affected brain regions. Then, we generated hemorrhage probabilistic maps of different etiologies and prognoses. By integrating radiomics and clinical features into multiple logistic regression models, we developed and validated optimal etiological and prognostic models across three centers, comprising 1162 sICH patients. Results: Hematomas of different etiology have unique spatial distributions. The location-based features demonstrated robust classification of the etiology of spontaneous intracerebral hemorrhage (sICH), with a mean area under the curve (AUC) of 0.825 across diverse datasets. These features provided significant incremental value when integrated into predictive models (fusion model mean AUC = 0.915), outperforming models relying solely on clinical features (mean AUC = 0.828). In prognostic assessments, both hematoma location (mean AUC = 0.762) and radiomic features (mean AUC = 0.837) contributed substantial incremental predictive value, as evidenced by the fusion model’s mean AUC of 0.873, compared to models utilizing clinical features alone (mean AUC = 0.771). Conclusions: Our results show that location features were more intrinsically robust, generalizable relative, strong interpretability to the complex modeling of radiomics, our approach demonstrated a novel interpretable, streamlined, comprehensive etiologic classification and prognostic prediction framework for sICH.
- 3 June 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (7) , 1761-1772
Open AccessPrediction of etiology and prognosis based on hematoma location of spontaneous intracerebral hemorrhage: a multicenter diagnostic study
Background: The location of the hemorrhagic of spontaneous intracerebral hemorrhage (sICH) is clinically pivotal for both identifying its etiology and prognosis, but comprehensive and quantitative modeling approach has yet to be thoroughly explored. Methods: We employed lesion-symptom mapping to extract the location features of sICH. We registered patients’ non-contrast computed tomography image and hematoma masks with standard human brain templates to identify specific affected brain regions. Then, we generated hemorrhage probabilistic maps of different etiologies and prognoses. By integrating radiomics and clinical features into multiple logistic regression models, we developed and validated optimal etiological and prognostic models across three centers, comprising 1162 sICH patients. Results: Hematomas of different etiology have unique spatial distributions. The location-based features demonstrated robust classification of the etiology of spontaneous intracerebral hemorrhage (sICH), with a mean area under the curve (AUC) of 0.825 across diverse datasets. These features provided significant incremental value when integrated into predictive models (fusion model mean AUC = 0.915), outperforming models relying solely on clinical features (mean AUC = 0.828). In prognostic assessments, both hematoma location (mean AUC = 0.762) and radiomic features (mean AUC = 0.837) contributed substantial incremental predictive value, as evidenced by the fusion model’s mean AUC of 0.873, compared to models utilizing clinical features alone (mean AUC = 0.771). Conclusions: Our results show that location features were more intrinsically robust, generalizable relative, strong interpretability to the complex modeling of radiomics, our approach demonstrated a novel interpretable, streamlined, comprehensive etiologic classification and prognostic prediction framework for sICH.
- 1 June 2023
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 96 (1146) , 20221006
An automatic fresh rib fracture detection and positioning system using deep learning
Objective: To evaluate the performance and robustness of a deep learning-based automatic fresh rib fracture detection and positioning system (FRF-DPS). Methods: CT scans of 18,172 participants admitted to eight hospitals from June 2009 to March 2019 were retrospectively collected. Patients were divided into development set (14,241), multicenter internal test set (1612), and external test set (2319). In internal test set, sensitivity, false positives (FPs) and specificity were used to assess fresh rib fracture detection performance at the lesion- and examination-levels. In external test set, the performance of detecting fresh rib fractures by radiologist and FRF-DPS were evaluated at lesion, rib, and examination levels. Additionally, the accuracy of FRF-DPS in rib positioning was investigated by the ground-truth labeling. Results: In multicenter internal test set, FRF-DPS showed excellent performance at the lesion- (sensitivity: 0.933 [95%CI, 0.916–0.949], FPs: 0.50 [95%CI, 0.397–0.583]) and examination-level. In external test set, the sensitivity and FPs at the lesion-level of FRF-DPS (0.909 [95%CI, 0.883–0.926], p < 0.001; 0.379 [95%CI, 0.303–0.422], p = 0.001) were better than the radiologist (0.789 [95%CI, 0.766–0.807]; 0.496 [95%CI, 0.383–0.571]), so were the rib- and patient-levels. In subgroup analysis of CT parameters, FRF-DPS were robust (0.894–0.927). Finally, FRF-DPS(0.997 [95%CI, 0.992–1.000], p < 0.001) is more accurate than radiologist (0.981 [95%CI, 0.969–0.996]) in rib positioning and takes 20 times less time. Conclusion: FRF-DPS achieved high detection rate of fresh rib fractures with low FP values, and precise positioning of ribs, thus can be used in clinical practice to improve the detection rate and work efficiency. Advances in knowledge: We developed the FRF-DPS system which can detect fresh rib fractures and rib position, and evaluated by a large amount of multicenter data.
- 1 June 2023
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 96 (1146) , 20221006
An automatic fresh rib fracture detection and positioning system using deep learning
Objective: To evaluate the performance and robustness of a deep learning-based automatic fresh rib fracture detection and positioning system (FRF-DPS). Methods: CT scans of 18,172 participants admitted to eight hospitals from June 2009 to March 2019 were retrospectively collected. Patients were divided into development set (14,241), multicenter internal test set (1612), and external test set (2319). In internal test set, sensitivity, false positives (FPs) and specificity were used to assess fresh rib fracture detection performance at the lesion- and examination-levels. In external test set, the performance of detecting fresh rib fractures by radiologist and FRF-DPS were evaluated at lesion, rib, and examination levels. Additionally, the accuracy of FRF-DPS in rib positioning was investigated by the ground-truth labeling. Results: In multicenter internal test set, FRF-DPS showed excellent performance at the lesion- (sensitivity: 0.933 [95%CI, 0.916–0.949], FPs: 0.50 [95%CI, 0.397–0.583]) and examination-level. In external test set, the sensitivity and FPs at the lesion-level of FRF-DPS (0.909 [95%CI, 0.883–0.926], p < 0.001; 0.379 [95%CI, 0.303–0.422], p = 0.001) were better than the radiologist (0.789 [95%CI, 0.766–0.807]; 0.496 [95%CI, 0.383–0.571]), so were the rib- and patient-levels. In subgroup analysis of CT parameters, FRF-DPS were robust (0.894–0.927). Finally, FRF-DPS(0.997 [95%CI, 0.992–1.000], p < 0.001) is more accurate than radiologist (0.981 [95%CI, 0.969–0.996]) in rib positioning and takes 20 times less time. Conclusion: FRF-DPS achieved high detection rate of fresh rib fractures with low FP values, and precise positioning of ribs, thus can be used in clinical practice to improve the detection rate and work efficiency. Advances in knowledge: We developed the FRF-DPS system which can detect fresh rib fractures and rib position, and evaluated by a large amount of multicenter data.
- Open Access
A Tri-light Warning System for Hospitalized COVID-19 Patients: Credibility-based Risk Stratification under Data Shift
OBJECTIVE To develop a tri-light warning system for the early warning of novel coronavirus pneumonia (COVID-19) and stratification of patients. MATERIALS AND METHODS The system extracts radiomic features from CT images and integrates clinical record information to output a prediction probability and credibility of each prediction. It classifies patients in the general ward into red (high risk), yellow (uncertain risk), and green (low risk) labels. The system was tested using a multi-center cohort of 8,721 patients. RESULTS The system demonstrated reliability and performance validation under data distribution shifts, and was applicable to both the original strain and variant strains of COVID-19. DISCUSSION The tri-light warning system has the potential to improve patient stratification performance and identify epidemiological risks early, thus allowing for timely treatment and optimization of medical resource allocation. CONCLUSION The tri-light warning system based on conformal prediction is a reliable and effective method for the early warning and stratification of COVID-19 patients.
Open AccessA Tri-light Warning System for Hospitalized COVID-19 Patients: Credibility-based Risk Stratification under Data Shift
OBJECTIVE To develop a tri-light warning system for the early warning of novel coronavirus pneumonia (COVID-19) and stratification of patients. MATERIALS AND METHODS The system extracts radiomic features from CT images and integrates clinical record information to output a prediction probability and credibility of each prediction. It classifies patients in the general ward into red (high risk), yellow (uncertain risk), and green (low risk) labels. The system was tested using a multi-center cohort of 8,721 patients. RESULTS The system demonstrated reliability and performance validation under data distribution shifts, and was applicable to both the original strain and variant strains of COVID-19. DISCUSSION The tri-light warning system has the potential to improve patient stratification performance and identify epidemiological risks early, thus allowing for timely treatment and optimization of medical resource allocation. CONCLUSION The tri-light warning system based on conformal prediction is a reliable and effective method for the early warning and stratification of COVID-19 patients.
- 22 December 2020
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 94 (1118) , 20200089
Dependence of radiomic features on pixel size affects the diagnostic performance of radiomic signature for the invasiveness of pulmonary ground-glass nodule
Objective: To investigate the effect of reducing pixel size on the consistency of radiomic features and the diagnostic performance of the downstream radiomic signatures for the invasiveness for pulmonary ground-glass nodules (GGNs) on CTs. Methods: We retrospectively collected the clinical data of 182 patients with GGNs on high resolution CT (HRCT). The CT images of different pixel sizes (0.8mm, 0.4mm, 0.18 mm) were obtained by reconstructing the single HRCT scan using three combinations of field of view and matrix size. For each pixel size setting, radiomic features were extracted for all GGNs and radiomic signatures for the invasiveness of GGNs were built through two modeling pipelines for comparison. Results: The study finally extracted 788 radiomic features. 87% radiomic features demonstrated inter pixel size variation. By either modeling pipeline, the radiomic signature under small pixel size performed significantly better than those under middle or large pixel sizes in predicting the invasiveness of GGNs (p’s value <0.05 by Delong test). With the independent modeling pipeline, the three pixel size bounded radiomic signatures shared almost no common features. Conclusions: Reducing pixel size could cause inconsistency in most radiomic features and improve the diagnostic performance of the downstream radiomic signatures. Particularly, super HRCTs with small pixel size resulted in more accurate radiomic signatures for the invasiveness of GGNs. Advances in knowledge: The dependence of radiomic features on pixel size will affect the performance of the downstream radiomic signatures. The future radiomic studies should consider this effect of pixel size.
- 22 December 2020
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 94 (1118) , 20200089
Dependence of radiomic features on pixel size affects the diagnostic performance of radiomic signature for the invasiveness of pulmonary ground-glass nodule
Objective: To investigate the effect of reducing pixel size on the consistency of radiomic features and the diagnostic performance of the downstream radiomic signatures for the invasiveness for pulmonary ground-glass nodules (GGNs) on CTs. Methods: We retrospectively collected the clinical data of 182 patients with GGNs on high resolution CT (HRCT). The CT images of different pixel sizes (0.8mm, 0.4mm, 0.18 mm) were obtained by reconstructing the single HRCT scan using three combinations of field of view and matrix size. For each pixel size setting, radiomic features were extracted for all GGNs and radiomic signatures for the invasiveness of GGNs were built through two modeling pipelines for comparison. Results: The study finally extracted 788 radiomic features. 87% radiomic features demonstrated inter pixel size variation. By either modeling pipeline, the radiomic signature under small pixel size performed significantly better than those under middle or large pixel sizes in predicting the invasiveness of GGNs (p’s value <0.05 by Delong test). With the independent modeling pipeline, the three pixel size bounded radiomic signatures shared almost no common features. Conclusions: Reducing pixel size could cause inconsistency in most radiomic features and improve the diagnostic performance of the downstream radiomic signatures. Particularly, super HRCTs with small pixel size resulted in more accurate radiomic signatures for the invasiveness of GGNs. Advances in knowledge: The dependence of radiomic features on pixel size will affect the performance of the downstream radiomic signatures. The future radiomic studies should consider this effect of pixel size.