Chengxiang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Chengxiang Wang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Dingbang Xiao
College of Intelligence Science and Technology, National University of Defense Technology, Changsha 410073, China
6 shared publications - Qingsong Li
College of Intelligence Science and Technology, National University of Defense Technology, Changsha, China
4 shared publications Xuezhong Wu
4 shared publications- Xuezhong Wu
College of Intelligence Science and Technology, National University of Defense Technology, Changsha, China
4 shared publications Yulie Wu
3 shared publications- Zhanqiang Hou
College of Intelligence Science and Technology, National University of Defense Technology, Changsha 410073, China
3 shared publications
Latest Publications
- 21 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 45 (7) , 1297-1300
Initial Demonstration of an Inductive Vibrating Ring Gyroscope Fabricated From Fused Silica
This letter presents a fused silica inductive vibrating ring gyroscope (IVRG). The resonator of the gyroscope is fabricated on a 4-inch fused silica wafer. Benefiting from the technique of laser-induced assisted etching (LIAE), the microstructures on the fused silica wafers have an extremely high aspect ratio of 60.2 and the average roughness of the sidewall is 0.41 μm. The voltage can be directly extracted from the resonator without performing a C/V converter. This device has a Q factor of 1007196 and 1104764 and a resonant frequency of 17950.77 Hz and 17950.86 Hz after vacuum packaged. Although the gyroscope has a maximum angle-dependent bias drift of 0.42 °/s when operated in the rate-integration mode, the angle tracking error is only 4.3° (34.1ppm) after 30 seconds high-speed rotation test.
- 21 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 45 (7) , 1297-1300
Initial Demonstration of an Inductive Vibrating Ring Gyroscope Fabricated From Fused Silica
This letter presents a fused silica inductive vibrating ring gyroscope (IVRG). The resonator of the gyroscope is fabricated on a 4-inch fused silica wafer. Benefiting from the technique of laser-induced assisted etching (LIAE), the microstructures on the fused silica wafers have an extremely high aspect ratio of 60.2 and the average roughness of the sidewall is 0.41 μm. The voltage can be directly extracted from the resonator without performing a C/V converter. This device has a Q factor of 1007196 and 1104764 and a resonant frequency of 17950.77 Hz and 17950.86 Hz after vacuum packaged. Although the gyroscope has a maximum angle-dependent bias drift of 0.42 °/s when operated in the rate-integration mode, the angle tracking error is only 4.3° (34.1ppm) after 30 seconds high-speed rotation test.
- 9 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 71 (2) , 1231-1237
A MEMS Friction Gauge For High Vacuum Measurement
High vacuum measurements are required in space exploration, the semiconductor industry, and other fields; however, minimized vacuum gauge for high vacuum (< 0.1 Pa) measurement remains unsettled. Herein, we present a microelectromechanical system (MEMS)-based friction vacuum gauge with a large damping area and a small air gap for gas damping ( $1/{Q}_{\text {air}}{)}$ enhancement, along with a double torsion mode to reduce thermal elastic damping losses ( $1/{Q}_{\text {ted}}{)}$ and anchor losses ( $1/{Q}_{\text {anchor}}{)}$ . After using the damping adjustment methods, the lower limit of the gauge in the linear range ( ${P}_{d}{)}$ was extended to $1.6\times 10^{-{3}}$ Pa. The gauge covers a linear measurement range from $1.6\times 10^{-{3}}$ to 0.1 Pa with excellent repeatability, high resolution ( $1.0\times 10^{-{4}}$ Pa), and a good temperature characteristic (0.107%/°C). This gauge is anticipated to be used for leakage measurements of microvacuum chambers, as well as integrated with other miniaturized vacuum gauges to expand the measurement range of MEMS vacuum gauges.
- 9 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 71 (2) , 1231-1237
A MEMS Friction Gauge For High Vacuum Measurement
High vacuum measurements are required in space exploration, the semiconductor industry, and other fields; however, minimized vacuum gauge for high vacuum (< 0.1 Pa) measurement remains unsettled. Herein, we present a microelectromechanical system (MEMS)-based friction vacuum gauge with a large damping area and a small air gap for gas damping ( $1/{Q}_{\text {air}}{)}$ enhancement, along with a double torsion mode to reduce thermal elastic damping losses ( $1/{Q}_{\text {ted}}{)}$ and anchor losses ( $1/{Q}_{\text {anchor}}{)}$ . After using the damping adjustment methods, the lower limit of the gauge in the linear range ( ${P}_{d}{)}$ was extended to $1.6\times 10^{-{3}}$ Pa. The gauge covers a linear measurement range from $1.6\times 10^{-{3}}$ to 0.1 Pa with excellent repeatability, high resolution ( $1.0\times 10^{-{4}}$ Pa), and a good temperature characteristic (0.107%/°C). This gauge is anticipated to be used for leakage measurements of microvacuum chambers, as well as integrated with other miniaturized vacuum gauges to expand the measurement range of MEMS vacuum gauges.
- Open Access
- 20 October 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (10) , 1957
Research on the Mass Adding and Removing Combined Mechanical Trimming Method of the Ring MEMS Gyroscope
The MEMS gyroscope is one of the basic units of inertial navigation, whose performance and accuracy is noteworthy. Because of the limitations of processing technology and other factors, the relative manufacturing error of MEMS gyroscopes is usually large. Errors directly lead to a frequency mismatch of resonant structures and consequently restrict the performance improvement of the gyroscope. This study proposes a mechanical trimming technique combining the addition and removal of gold in a ring MEMS gyroscope. Firstly, the analysis of the gyroscope dynamics and error model and trimming theory provides theoretical guidance for the trimming process. Secondly, the method of adjusting the mass is investigated, and the ablation threshold of femtosecond laser parameters on gold is analyzed, which provides the process with parameters for the trimming experiment. Finally, the frequency trimming process is conducted in three steps, including the addition of gold spheres and the removal of gold spheres and gold film, which are applicable to the trimming process at different rates of frequency split. The results shows that the proposed method can reduce the frequency split of the gyroscope from 4.36 to 0.017 Hz.
- 20 October 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (10) , 1957
Open AccessResearch on the Mass Adding and Removing Combined Mechanical Trimming Method of the Ring MEMS Gyroscope
The MEMS gyroscope is one of the basic units of inertial navigation, whose performance and accuracy is noteworthy. Because of the limitations of processing technology and other factors, the relative manufacturing error of MEMS gyroscopes is usually large. Errors directly lead to a frequency mismatch of resonant structures and consequently restrict the performance improvement of the gyroscope. This study proposes a mechanical trimming technique combining the addition and removal of gold in a ring MEMS gyroscope. Firstly, the analysis of the gyroscope dynamics and error model and trimming theory provides theoretical guidance for the trimming process. Secondly, the method of adjusting the mass is investigated, and the ablation threshold of femtosecond laser parameters on gold is analyzed, which provides the process with parameters for the trimming experiment. Finally, the frequency trimming process is conducted in three steps, including the addition of gold spheres and the removal of gold spheres and gold film, which are applicable to the trimming process at different rates of frequency split. The results shows that the proposed method can reduce the frequency split of the gyroscope from 4.36 to 0.017 Hz.
- Open Access
- 30 June 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (7) , 1052
A Novel Mechanical Frequency Tuning Method Based on Mass-Stiffness Decoupling for MEMS Gyroscopes
MEMS gyroscopes play an important role in inertial navigation measurements, which mainly works in n = 2 mode. However, mode matching is the basis for high-precision detection, which can improve the sensitivity, resolution, and signal-to-noise ratio of the gyroscopes. An initial frequency split is inevitably generated during the manufacturing process. There are two methods to eliminate the frequency split and to achieve mode matching for the gyroscopes, which are electrostatic tuning and mechanical trimming, respectively. In this paper, we report a novel ring MEMS resonator and a novel method of mechanical frequency tuning. The most prominent characteristic of the resonator is that 16 raised mass blocks are increased in the circumferential positions of the ring uniformly. This structural design can achieve mass-stiffness decoupling, which means that punching holes on the mass blocks only affects the mass distribution but the stiffness is almost unchanged for the resonator. We verify the mass-stiffness decoupling by way of comparing the simulation with the conventional resonator. In addition, we put up an online tuning platform based on a femtosecond laser and reduce a resonator’s frequency split from 23.3 Hz to 0.4 Hz, which reveals that the frequency split is linearly related to the removed mass. These findings will have a referential significance for other transducers.
- 30 June 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (7) , 1052
Open AccessA Novel Mechanical Frequency Tuning Method Based on Mass-Stiffness Decoupling for MEMS Gyroscopes
MEMS gyroscopes play an important role in inertial navigation measurements, which mainly works in n = 2 mode. However, mode matching is the basis for high-precision detection, which can improve the sensitivity, resolution, and signal-to-noise ratio of the gyroscopes. An initial frequency split is inevitably generated during the manufacturing process. There are two methods to eliminate the frequency split and to achieve mode matching for the gyroscopes, which are electrostatic tuning and mechanical trimming, respectively. In this paper, we report a novel ring MEMS resonator and a novel method of mechanical frequency tuning. The most prominent characteristic of the resonator is that 16 raised mass blocks are increased in the circumferential positions of the ring uniformly. This structural design can achieve mass-stiffness decoupling, which means that punching holes on the mass blocks only affects the mass distribution but the stiffness is almost unchanged for the resonator. We verify the mass-stiffness decoupling by way of comparing the simulation with the conventional resonator. In addition, we put up an online tuning platform based on a femtosecond laser and reduce a resonator’s frequency split from 23.3 Hz to 0.4 Hz, which reveals that the frequency split is linearly related to the removed mass. These findings will have a referential significance for other transducers.
- Open Access
- 18 October 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (10) , 1270
Batch Manufacturing of Split-Actuator Micro Air Vehicle Based on Monolithic Processing Technology
Microrobots have a wide range of applications. The rigid–flexible composite stereoscopic technology based on ultraviolet laser cutting technology is primarily researched for the design and manufacture of microrobots and has been used to fabricate microscale motion mechanisms and robots. This paper introduces a monolithic processing technology based on the rigid–flexible composite stereoscopic process. Based on this process, a split-actuator micro flapping-wing air vehicle with a size of 15 mm × 2.5 mm × 30 mm was designed. We proposed a batch manufacturing method capable of processing multiple micro air vehicles at the same time. The main structure of 22 flapping-wing micro air vehicles can be processed at the same time within the processing range of the composite sheet with an area of 80 mm × 80 mm, and the processing effect is good.
- 18 October 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (10) , 1270
Open AccessBatch Manufacturing of Split-Actuator Micro Air Vehicle Based on Monolithic Processing Technology
Microrobots have a wide range of applications. The rigid–flexible composite stereoscopic technology based on ultraviolet laser cutting technology is primarily researched for the design and manufacture of microrobots and has been used to fabricate microscale motion mechanisms and robots. This paper introduces a monolithic processing technology based on the rigid–flexible composite stereoscopic process. Based on this process, a split-actuator micro flapping-wing air vehicle with a size of 15 mm × 2.5 mm × 30 mm was designed. We proposed a batch manufacturing method capable of processing multiple micro air vehicles at the same time. The main structure of 22 flapping-wing micro air vehicles can be processed at the same time within the processing range of the composite sheet with an area of 80 mm × 80 mm, and the processing effect is good.
- Open Access
- 16 August 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (8) , 969
Miniature Ultralight Deformable Squama Mechanics and Skin Based on Piezoelectric Actuation
A miniature deformable squama mechanics based on piezoelectric actuation inspired by the deformable squama is proposed in this paper. The overall size of the mechanics is 16 mm × 6 mm × 6 mm, the weight is only 140 mg, the deflection angle range of the mechanical deformation is −15°~45°, and the mechanical deformation is controllable. The small-batch array processing of the miniature deformable squama mechanics, based on the stereoscopic process, laid the technological foundation for applying the deformed squama array arrangement. We also designed and manufactured a small actuation control boost circuit and a mobile phone piezoelectric control assistant application that makes it convenient to perform short-range non-contact control of the deformation of the squama. The proposed system arranges the deformed squamae into groups to form the skin and controlls the size and direction of the signals input to each group of the squama array, thereby making the skin able to produce different shapes to create deformable skin.
- 16 August 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (8) , 969
Open AccessMiniature Ultralight Deformable Squama Mechanics and Skin Based on Piezoelectric Actuation
A miniature deformable squama mechanics based on piezoelectric actuation inspired by the deformable squama is proposed in this paper. The overall size of the mechanics is 16 mm × 6 mm × 6 mm, the weight is only 140 mg, the deflection angle range of the mechanical deformation is −15°~45°, and the mechanical deformation is controllable. The small-batch array processing of the miniature deformable squama mechanics, based on the stereoscopic process, laid the technological foundation for applying the deformed squama array arrangement. We also designed and manufactured a small actuation control boost circuit and a mobile phone piezoelectric control assistant application that makes it convenient to perform short-range non-contact control of the deformation of the squama. The proposed system arranges the deformed squamae into groups to form the skin and controlls the size and direction of the signals input to each group of the squama array, thereby making the skin able to produce different shapes to create deformable skin.