SKShinya Kohashi

Shinya Kohashi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shinya Kohashi has a total of 30 co-authors. Here are the top co-authors by number of shared publications:

  • Arata Sakai

    Division of Gastroenterology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan

    5 shared publications
  • Yuzo Kodama

    Division of Gastroenterology, Department of Internal Medicine Kobe University Graduate School of Medicine Kobe Japan

    3 shared publications
  • Atsuhiro Masuda

    Division of Gastroenterology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan

    2 shared publications
  • Hideyuki Shiomi

    Division of Hepatobiliary and Pancreatic Diseases, Department of Gastroenterology Hyogo Medical University Nishinomiya Hyōgo Japan

    2 shared publications
  • Akihiro Yoshida

    Department of Gastroenterology and Hepatology Kindai University Faculty of Medicine Osakasayama Osaka Japan

    1 shared publication
  • Atsuhiro Masuda

    Department of Internal Medicine Division of Gastroenterology Kobe University Graduate School of Medicine Hyogo Japan

    1 shared publication

Latest Publications

  • A Case of Gallbladder Cancer With a Rare H-Like Morphology Pancreaticobiliary Maljunction

    by Takafumi Tokunaga, Shinya Kohashi, Arata Sakai

    An abstract is unavailable. This article is available as a PDF only.

  • Multicenter Comparative Study of 6‐ and 10‐mm Fully Covered Self‐Expandable Metal Stents for Malignant Distal Biliary Obstruction During Neoadjuvant Chemotherapy for Resectable and Borderline Resectable Pancreatic Cancer

    by Arata Sakai, Atsuhiro Masuda, Mamoru Takenaka, Hideyuki Shiomi, Shunsuke Omoto, Akihiro Yoshida, Ryota Nakano, Yuta Kawase, Shinya Kohashi, Yuzo Kodama, et al.

    Background: The use of 10‐mm fully covered self‐expandable metal stents for preoperative bile duct drainage in patients with pancreatic cancer is increasing. However, these can cause complications (cholecystitis and pancreatitis) that may affect surgical outcomes. Smaller‐diameter self‐expandable metal stents may reduce these risks; however, the optimal stent size is unclear.Methods: Patients with pancreatic cancer who underwent neoadjuvant chemotherapy and placement of either 6 or 10‐mm fully covered self‐expandable metal stents for malignant distal biliary obstruction were included. The primary outcome was the 90‐day incidence of recurrent biliary obstruction. Secondary outcomes were non‐recurrent biliary obstruction and adverse events.Results: Fifty‐three patients were enrolled (27 and 26 patients received 6‐mm and 10‐mm self‐expandable metal stents, respectively). The 90‐day incidence of recurrent biliary obstruction of the 6‐mm group was significantly higher than that of the 10‐mm group (30.8% vs. 3.8%; p = 0.02). Stent migration occurred more frequently in the 6‐mm group (26.9% vs. 0%; p = 0.01). Although non‐recurrent biliary obstruction adverse events were less common in the 6‐mm group, the difference was not statistically significant (11.1% vs. 23.0%; p = 0.29).Conclusions: The 10‐mm self‐expandable metal stents were more suitable for the preoperative management of pancreatic cancer.


  • Open Access

    The anti‐migration effect of partially covered self‐expandable metal stents for unresectable malignant distal biliary obstruction: A multicenter comparative study

    by Shinya Kohashi, Arata Sakai, Keisuke Furumatsu, Takeshi Ezaki, Takao Iemoto, Takeshi Tanaka, Masahiro Tsujimae, Takashi Kobayashi, Atsuhiro Masuda, Yuzo Kodama

    Objectives: Covered self‐expandable metal stents are commonly used for unresectable malignant distal biliary obstruction. Partially covered self‐expandable metal stents have uncovered sections at both ends; however, their anti‐migration effect remains unclear. The objective of this study was to evaluate that effect by comparing such stents with fully covered self‐expandable metal stents for patients with unresectable malignant distal biliary obstruction.Methods: This was a multicenter, retrospective comparative study of partially covered stents with fully covered stents for unresectable malignant distal biliary obstruction. Stent migration, recurrent biliary obstruction, and the time to recurrent biliary obstruction were compared between them.Results: Thirty‐nine patients with partially covered stents were included and compared with 42 patients with fully covered stents. The partially covered group had a significantly lower stent migration rate (3% vs. 36%; p < 0.001). The recurrent biliary obstruction rate was significantly lower in the partially covered group (21% vs. 43%; p = 0.036). The non‐recurrent biliary obstruction rate at 6 months was 90% and 68% in the partially and fully covered groups, respectively. The time to recurrent biliary obstruction was significantly longer in the partially covered group (Gray's test, p = 0.016). Only partially covered stent placement was significantly associated with a lower risk of stent migration (subdistribution hazard ratio = 0.077; 95% confidence interval = 0.01–0.60; p = 0.014) in the multivariable analysis.Conclusions: The anti‐migration effect of partially covered self‐expandable metal stents was associated with a reduced recurrence of biliary obstruction and prolonged time to such obstruction.


  • Open Access

    A novel fully covered metal stent for unresectable malignant distal biliary obstruction: results of a multicenter prospective study

    by Arata Sakai, Atsuhiro Masuda, Takaaki Eguchi, Keisuke Furumatsu, Takao Iemoto, Shiei Yoshida, Yoshihiro Okabe, Kodai Yamanaka, Ikuya Miki, Saori Kakuyama, et al.

    Background/Aims: Endoscopic self-expandable metal stent (SEMS) placement is currently the standard technique for treating unresectable malignant distal biliary obstructions (MDBO). Therefore, covered SEMS with longer stent patency and fewer migrations are required. This study aimed to assess the clinical performance of a novel, fully covered SEMS for unresectable MDBO.Methods: This was a multicenter single-arm prospective study. The primary outcome was a non-obstruction rate at 6 months. The secondary outcomes were overall survival (OS), recurrent biliary obstruction (RBO), time to RBO (TRBO), technical and clinical success, and adverse events.Results: A total of 73 patients were enrolled in this study. The non-obstruction rate at 6 months was 61%. The median OS and TRBO were 233 and 216 days, respectively. The technical and clinical success rates were 100% and 97%, respectively. Furthermore, the rate of occurrence of RBO and adverse events was 49% and 21%, respectively. The length of bile duct stenosis (<2.2 cm) was the only significant risk factor for stent migration.Conclusions: The non-obstruction rate of a novel fully covered SEMS for MDBO is comparable to that reported earlier but shorter than expected. Short bile duct stenosis is a significant risk factor for stent migration.