Anastasia Rakow
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anastasia Rakow has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Janosch Schoon
Center for Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University Medicine Greifswald, Greifswald, Germany
7 shared publications Carsten Perka
Center for Musculoskeletal Surgery, Charité–Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
4 shared publicationsGeorgi I. Wassilew
University Medicine Greifswald
4 shared publicationsKatrin Huesker
Institute for Medical Diagnostics (IMD)
3 shared publicationsAlexander Kowski
Department of Neurology, Charité–Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
1 shared publicationAnastasia Tavakina
University Medicine Greifswald
1 shared publication
Latest Publications
- Open Access
- 27 October 2026
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 12 (11) , 6144-6153
Linking Circulating Metal Levels to Cytokine Signatures in Total Joint Arthroplasty Patients
Arthroplasty may significantly improve the quality of life; however, wear and corrosion of metallic biomaterials can lead to the release of metal ions and particles, contributing to immune responses. Circulating metals may influence cytokine production, but systemic biomarkers of implant-related inflammation remain elusive. This study aimed to quantify systemic metal levels and cytokines to identify potential immunological signatures in patients exposed to arthroplasty metals. Peripheral blood samples from 150 patients scheduled for either primary or revision arthroplasty were analyzed. Whole blood multi-metal levels were quantified by inductively coupled plasma mass spectrometry. Plasma levels of 47 cytokines were quantified using a bead-based multiplex immunoassay. Cytokine patterns were examined via clustering and correlated with metal levels, adjusting for age, sex, prosthetic joint infection, lymphocyte count, C-reactive protein levels, and season. Blood levels of cobalt, chromium, titanium, niobium, and zirconium were significantly elevated in patients with arthroplasty implants, compared to arthroplasty-naïve controls. Selective correlations were observed, notably cobalt with IL-8 and multiple metals with IL-15. Cytokine clustering identified four distinct modules representing systemic immune activity. Multivariable linear regression modeling revealed associations of metal exposure with IL-1RA, IL-8, IL-15, and the proinflammatory cluster after adjusting for age, sex, periprosthetic joint infection status, inflammation markers, and season. This study shows that arthroprosthetic metal exposure is associated with systemic elevation of selective cytokines. Blood-based cytokine profiles may serve as biomarkers for monitoring implant-related immune activation, providing insights into mechanisms of systemic inflammation, yet must be interpreted within the context of multifactorial influences.
- 27 October 2026
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 12 (11) , 6144-6153
Open AccessLinking Circulating Metal Levels to Cytokine Signatures in Total Joint Arthroplasty Patients
Arthroplasty may significantly improve the quality of life; however, wear and corrosion of metallic biomaterials can lead to the release of metal ions and particles, contributing to immune responses. Circulating metals may influence cytokine production, but systemic biomarkers of implant-related inflammation remain elusive. This study aimed to quantify systemic metal levels and cytokines to identify potential immunological signatures in patients exposed to arthroplasty metals. Peripheral blood samples from 150 patients scheduled for either primary or revision arthroplasty were analyzed. Whole blood multi-metal levels were quantified by inductively coupled plasma mass spectrometry. Plasma levels of 47 cytokines were quantified using a bead-based multiplex immunoassay. Cytokine patterns were examined via clustering and correlated with metal levels, adjusting for age, sex, prosthetic joint infection, lymphocyte count, C-reactive protein levels, and season. Blood levels of cobalt, chromium, titanium, niobium, and zirconium were significantly elevated in patients with arthroplasty implants, compared to arthroplasty-naïve controls. Selective correlations were observed, notably cobalt with IL-8 and multiple metals with IL-15. Cytokine clustering identified four distinct modules representing systemic immune activity. Multivariable linear regression modeling revealed associations of metal exposure with IL-1RA, IL-8, IL-15, and the proinflammatory cluster after adjusting for age, sex, periprosthetic joint infection status, inflammation markers, and season. This study shows that arthroprosthetic metal exposure is associated with systemic elevation of selective cytokines. Blood-based cytokine profiles may serve as biomarkers for monitoring implant-related immune activation, providing insights into mechanisms of systemic inflammation, yet must be interpreted within the context of multifactorial influences.
- Open Access
- 25 February 2026
- Published by Elsevier in Fuß & Sprunggelenk
- Vol. 24 (1) , 39-53
Der flexible Pes planovalgus im Kindes- und Jugendalter – Diagnostik und Therapie
- 25 February 2026
- Published by Elsevier in Fuß & Sprunggelenk
- Vol. 24 (1) , 39-53
Open AccessDer flexible Pes planovalgus im Kindes- und Jugendalter – Diagnostik und Therapie
- Open Access
- 8 December 2025
- Published by SAGE Publications in Journal of Children's Orthopaedics
- Vol. 20 (1) , 23-29
Sonication findings do not support routine removal of paediatric orthopaedic implants
Purpose: The risk of implant-associated infection (IAI) is occasionally cited as an indication for routine removal of orthopaedic implants in children, but evidence is lacking. This study aimed at exploring the frequency of microbial colonization of paediatric orthopaedic implants by sonication, a gold standard for diagnosing IAI. Methods: Data of all patients aged p < 0.05). Results: One hundred and twenty-nine sonicated devices from 63 patients were included. Mean patient age at implantation was 9.8 years (standard deviation (SD) 3.4; range 3.0–15.6), mean implant in situ time was 2.2 years (SD 1.5; range 0.6–8.8). In all, 63 tension band plates, 35 locking screw plates, 26 cannulated screws, 3 intramedullary nails and 2 K-wires were evaluated. In total, 128/129 (99%) of implant sites were asymptomatic. Sonication fluid cultures of 24/128 (19%) implants from 21 asymptomatic patients showed non-significant growth of pathogens mainly related to the human skin microbiome, suggesting contamination. Conclusions: Sonication of implants removed from asymptomatic implant sites showed no significant microbial growth. Thus, the risk of IAI should be irrelevant for scheduling implant removal in children without signs and symptoms of infection. Significance of study: This study investigates for the first time the role of sonication in non-spinal paediatric orthopaedics and provides important insights into the question of routine implant removal in children, providing a foundation for future research.
- 8 December 2025
- Published by SAGE Publications in Journal of Children's Orthopaedics
- Vol. 20 (1) , 23-29
Open AccessSonication findings do not support routine removal of paediatric orthopaedic implants
Purpose: The risk of implant-associated infection (IAI) is occasionally cited as an indication for routine removal of orthopaedic implants in children, but evidence is lacking. This study aimed at exploring the frequency of microbial colonization of paediatric orthopaedic implants by sonication, a gold standard for diagnosing IAI. Methods: Data of all patients aged p < 0.05). Results: One hundred and twenty-nine sonicated devices from 63 patients were included. Mean patient age at implantation was 9.8 years (standard deviation (SD) 3.4; range 3.0–15.6), mean implant in situ time was 2.2 years (SD 1.5; range 0.6–8.8). In all, 63 tension band plates, 35 locking screw plates, 26 cannulated screws, 3 intramedullary nails and 2 K-wires were evaluated. In total, 128/129 (99%) of implant sites were asymptomatic. Sonication fluid cultures of 24/128 (19%) implants from 21 asymptomatic patients showed non-significant growth of pathogens mainly related to the human skin microbiome, suggesting contamination. Conclusions: Sonication of implants removed from asymptomatic implant sites showed no significant microbial growth. Thus, the risk of IAI should be irrelevant for scheduling implant removal in children without signs and symptoms of infection. Significance of study: This study investigates for the first time the role of sonication in non-spinal paediatric orthopaedics and provides important insights into the question of routine implant removal in children, providing a foundation for future research.
- 1 December 2025
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 107-B (12) , 1239-1241
Metal particles and ions and orthopaedic implants
Metal particles and ions and orthopaedic implants
- 1 December 2025
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 107-B (12) , 1239-1241
Metal particles and ions and orthopaedic implants
Metal particles and ions and orthopaedic implants
- Open Access
- 27 October 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 34 (6) , 2152-2160
Knee arthroplasty failure is associated with significant systemic multimetal exposure
Purpose: This study investigated whether patients scheduled for revision total knee arthroplasty (TKA) are systemically exposed to arthroplasty metals, and whether systemic metal levels in these patients differ depending on the implants' levels of constraint. Methods: Whole blood samples were collected from patients scheduled for revision TKA (implant group, n = 51) and from arthroplasty‐naïve controls ( n = 53). Using inductively coupled plasma mass spectrometry, all TKA‐relevant metals were quantified. Differences in systemic metal levels in patients with failed unconstrained implants ( n = 31) and constrained ( n = 20) implants were analysed. Correlations between levels of the different arthroplasty metals were assessed, using the Mann–Whitney test, Kruskal–Wallis test with Dunn's multiple comparison test, Spearman r matrix, and linear regression with Spearman correlation as appropriate. A p < 0.05 was considered statistically significant. Results: Patients scheduled for revision TKA showed significantly higher systemic Co ( p < 0.001), Cr ( p < 0.001), Mo ( p = 0.039), Ti ( p < 0.001), Nb ( p < 0.001) and Zr ( p < 0.001) levels compared with controls. Failed constrained TKA implants were associated with significantly higher levels of Co ( p = 0.002), Cr ( p = 0.005), Ti ( p = 0.047), Nb ( p = 0.023) and Zr ( p = 0.046) than detected in patients with failed unconstrained TKA implant. In patients awaiting revision of a constrained implant, whole blood levels of Co and Ti ( p < 0.001), as well as of Zr and Ti ( p < 0.001) significantly correlated, whereas no such correlations were observed in patients with failed unconstrained TKA implant. Conclusions: Patients with failed TKA are systemically exposed to arthroplasty metals. Correlation analyses suggest a link between the release of Co and Ti as well as of Zr and Ti in patients awaiting revision of a constrained TKA implant. Additional research is required to investigate the potential biological effects of TKA‐related metals, and to establish clinically relevant systemic threshold levels. Level of Evidence: Level II therapeutic study.
- 27 October 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 34 (6) , 2152-2160
Open AccessKnee arthroplasty failure is associated with significant systemic multimetal exposure
Purpose: This study investigated whether patients scheduled for revision total knee arthroplasty (TKA) are systemically exposed to arthroplasty metals, and whether systemic metal levels in these patients differ depending on the implants' levels of constraint. Methods: Whole blood samples were collected from patients scheduled for revision TKA (implant group, n = 51) and from arthroplasty‐naïve controls ( n = 53). Using inductively coupled plasma mass spectrometry, all TKA‐relevant metals were quantified. Differences in systemic metal levels in patients with failed unconstrained implants ( n = 31) and constrained ( n = 20) implants were analysed. Correlations between levels of the different arthroplasty metals were assessed, using the Mann–Whitney test, Kruskal–Wallis test with Dunn's multiple comparison test, Spearman r matrix, and linear regression with Spearman correlation as appropriate. A p < 0.05 was considered statistically significant. Results: Patients scheduled for revision TKA showed significantly higher systemic Co ( p < 0.001), Cr ( p < 0.001), Mo ( p = 0.039), Ti ( p < 0.001), Nb ( p < 0.001) and Zr ( p < 0.001) levels compared with controls. Failed constrained TKA implants were associated with significantly higher levels of Co ( p = 0.002), Cr ( p = 0.005), Ti ( p = 0.047), Nb ( p = 0.023) and Zr ( p = 0.046) than detected in patients with failed unconstrained TKA implant. In patients awaiting revision of a constrained implant, whole blood levels of Co and Ti ( p < 0.001), as well as of Zr and Ti ( p < 0.001) significantly correlated, whereas no such correlations were observed in patients with failed unconstrained TKA implant. Conclusions: Patients with failed TKA are systemically exposed to arthroplasty metals. Correlation analyses suggest a link between the release of Co and Ti as well as of Zr and Ti in patients awaiting revision of a constrained TKA implant. Additional research is required to investigate the potential biological effects of TKA‐related metals, and to establish clinically relevant systemic threshold levels. Level of Evidence: Level II therapeutic study.
- Open Access
- 3 March 2025
- Published by American Medical Association (AMA) in JAMA Network Open
- Vol. 8 (3) , e252281
Metal Concentrations in Blood and Cerebrospinal Fluid of Patients With Arthroplasty Implants
Importance: Arthroprosthetic metal exposure has been linked to neurological dysfunction, but evidence of central nervous system exposure is largely missing.Objective: To compare levels of all arthroplasty-relevant metals in cerebrospinal fluid (CSF), whole blood, and serum of patients with and without large joint replacement.Design, Setting, and Participants: The NeuroWear pilot study was a single-site hospital-based cross-sectional study conducted between April 2018 and November 2019. Laboratory personnel and investigators were blinded to group allocation. Patients presenting for elective surgery under spinal anesthesia and patients scheduled for lumbar puncture at a university medical center were eligible for inclusion. Patients aged 18 years and older with at least 1 large joint replacement in situ (103 case participants) and age- and sex-matched arthroplasty-naive patients (108 control participants) were recruited. One case and 6 control participants were excluded. Each case participant was matched with 1 control participant to achieve equal self-reported sex and a minimal age difference. The data analyses were performed between May 2023 and February 2024.Exposure: Presence of large joint replacement.Main Outcomes and Measures: CSF, whole blood, and serum levels of aluminum, cobalt, chromium, molybdenum, nickel, niobium, tantalum, titanium, vanadium, and zirconium were quantified.Results: A total of 204 patients (118 [58%] women and 86 [42%] men; median [range] age 69.4 [21.3-93.1] years) were included for metal analyses. In CSF, median (range) cobalt levels were significantly higher in the implant group (0.03 [0.01-0.64] μg/L) compared with the control group (0.02 [0.01-0.19] μg/L). Cobalt levels in CSF were significantly correlated with cobalt levels in serum (r = 0.72; 95% CI, 0.53-0.85) and whole blood (r = 0.82; 95% CI, 0.62-0.92). Significantly higher whole blood median (range) levels of cobalt (implant: 0.27 [0.07-24.10] μg/L; control: 0.16 [0.08-0.99] μg/L), chromium (implant: 0.47 [0.24-4.76] μg/L; control: 0.42 [0.21-1.52] μg/L), titanium (implant: 8.05 [1.14-37.20] μg/L; control: 7.15 [1.80-20.70] μg/L), niobium (implant: 0.02 [0.01-1.14] μg/L; control: 0.01 [0.01-0.11] μg/L), and zirconium (implant: 0.05 [0.01-39.90] μg/L; control: 0.03 [0.01-1.95] μg/L) were detected. Patients with an implant were found to have significantly higher median (range) CSF metal levels for titanium (implant: 0.75 [0.12-1.40] μg/L; control: 0.57 [0.13-1.10] μg/L), niobium (implant: 0.02 [0.01-0.16] μg/L; control: 0.01 [0.01-0.03] μg/L), and zirconium (implant: 0.05 [0.01-0.44] μg/L; control: 0.04 [0.01-0.28] μg/L) if those metal levels were elevated in serum. Patients with cobalt-chromium-molybdenum implant components exhibited significantly higher median (range) chromium levels in CSF than control participants (implant: 0.31 [0.02-2.05] μg/L; control: 0.23 [0.02-1.10] μg/L).Conclusions and Relevance: In this cross-sectional study, chronic exposure to arthroplasty implants was associated with corresponding metal accumulation in blood and CSF. Arthroprosthetic cobalt, chromium, titanium, niobium, and zirconium seemed to cross neural barriers and accumulate in CSF. Correlation analyses suggested cobalt-specific transport mechanisms across neural barriers. In view of the neurotoxic effects of cobalt, subsequent studies are needed to determine whether CSF metal concentrations correlate with objective measures of neurotoxic effects and whether this may be of relevance, particularly in patients with new-onset or rapid deterioration of neurological conditions following arthroplasty.
- 3 March 2025
- Published by American Medical Association (AMA) in JAMA Network Open
- Vol. 8 (3) , e252281
Open AccessMetal Concentrations in Blood and Cerebrospinal Fluid of Patients With Arthroplasty Implants
Importance: Arthroprosthetic metal exposure has been linked to neurological dysfunction, but evidence of central nervous system exposure is largely missing.Objective: To compare levels of all arthroplasty-relevant metals in cerebrospinal fluid (CSF), whole blood, and serum of patients with and without large joint replacement.Design, Setting, and Participants: The NeuroWear pilot study was a single-site hospital-based cross-sectional study conducted between April 2018 and November 2019. Laboratory personnel and investigators were blinded to group allocation. Patients presenting for elective surgery under spinal anesthesia and patients scheduled for lumbar puncture at a university medical center were eligible for inclusion. Patients aged 18 years and older with at least 1 large joint replacement in situ (103 case participants) and age- and sex-matched arthroplasty-naive patients (108 control participants) were recruited. One case and 6 control participants were excluded. Each case participant was matched with 1 control participant to achieve equal self-reported sex and a minimal age difference. The data analyses were performed between May 2023 and February 2024.Exposure: Presence of large joint replacement.Main Outcomes and Measures: CSF, whole blood, and serum levels of aluminum, cobalt, chromium, molybdenum, nickel, niobium, tantalum, titanium, vanadium, and zirconium were quantified.Results: A total of 204 patients (118 [58%] women and 86 [42%] men; median [range] age 69.4 [21.3-93.1] years) were included for metal analyses. In CSF, median (range) cobalt levels were significantly higher in the implant group (0.03 [0.01-0.64] μg/L) compared with the control group (0.02 [0.01-0.19] μg/L). Cobalt levels in CSF were significantly correlated with cobalt levels in serum (r = 0.72; 95% CI, 0.53-0.85) and whole blood (r = 0.82; 95% CI, 0.62-0.92). Significantly higher whole blood median (range) levels of cobalt (implant: 0.27 [0.07-24.10] μg/L; control: 0.16 [0.08-0.99] μg/L), chromium (implant: 0.47 [0.24-4.76] μg/L; control: 0.42 [0.21-1.52] μg/L), titanium (implant: 8.05 [1.14-37.20] μg/L; control: 7.15 [1.80-20.70] μg/L), niobium (implant: 0.02 [0.01-1.14] μg/L; control: 0.01 [0.01-0.11] μg/L), and zirconium (implant: 0.05 [0.01-39.90] μg/L; control: 0.03 [0.01-1.95] μg/L) were detected. Patients with an implant were found to have significantly higher median (range) CSF metal levels for titanium (implant: 0.75 [0.12-1.40] μg/L; control: 0.57 [0.13-1.10] μg/L), niobium (implant: 0.02 [0.01-0.16] μg/L; control: 0.01 [0.01-0.03] μg/L), and zirconium (implant: 0.05 [0.01-0.44] μg/L; control: 0.04 [0.01-0.28] μg/L) if those metal levels were elevated in serum. Patients with cobalt-chromium-molybdenum implant components exhibited significantly higher median (range) chromium levels in CSF than control participants (implant: 0.31 [0.02-2.05] μg/L; control: 0.23 [0.02-1.10] μg/L).Conclusions and Relevance: In this cross-sectional study, chronic exposure to arthroplasty implants was associated with corresponding metal accumulation in blood and CSF. Arthroprosthetic cobalt, chromium, titanium, niobium, and zirconium seemed to cross neural barriers and accumulate in CSF. Correlation analyses suggested cobalt-specific transport mechanisms across neural barriers. In view of the neurotoxic effects of cobalt, subsequent studies are needed to determine whether CSF metal concentrations correlate with objective measures of neurotoxic effects and whether this may be of relevance, particularly in patients with new-onset or rapid deterioration of neurological conditions following arthroplasty.
- 20 November 2024
- Published by Springer Nature
- p. 111-131
Grundlagen des Hüftgelenkersatzes: Biologische Reaktionen auf Abrieb
- 20 November 2024
- Published by Springer Nature
- p. 111-131
Grundlagen des Hüftgelenkersatzes: Biologische Reaktionen auf Abrieb
- 18 December 2023
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 10 (1) , 563-574
Cobalt and Chromium Ions Impair Macrophage Response to Staphylococcus aureus Infection
Cobalt-chromium-molybdenum (CoCrMo) alloys are routinely used in arthroplasty. CoCrMo wear particles and ions derived from arthroplasty implants lead to macrophage-driven adverse local tissue reactions, which have been linked to an increased risk of periprosthetic joint infection after revision arthroplasty. While metal-induced cytotoxicity is well characterized in human macrophages, direct effects on their functionality have remained elusive. Synchrotron radiation X-ray microtomography and X-ray fluorescence mapping indicated that peri-implant tissues harvested during aseptic revision of different arthroplasty implants are exposed to Co and Cr in situ. Confocal laser scanning microscopy revealed that macrophage influx is predominant in patient tissue. While in vitro exposure to Cr3+ had only minor effects on monocytes/macrophage phenotype, pathologic concentrations of Co2+ significantly impaired both, monocyte/macrophage phenotype and functionality. High concentrations of Co2+ led to a shift in macrophage subsets and loss of surface markers, including CD14 and CD16. Both Co2+ and Cr3+ impaired macrophage responses to Staphylococcus aureus infection, and particularly, Co2+-exposed macrophages showed decreased phagocytic activity. These findings demonstrate the immunosuppressive effects of locally elevated metal ions on the innate immune response and support further investigations, including studies exploring whether Co2+ and Cr3+ or CoCrMo alloys per se expose the patients to a higher risk of infections post-revision arthroplasty.
- 18 December 2023
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 10 (1) , 563-574
Cobalt and Chromium Ions Impair Macrophage Response to Staphylococcus aureus Infection
Cobalt-chromium-molybdenum (CoCrMo) alloys are routinely used in arthroplasty. CoCrMo wear particles and ions derived from arthroplasty implants lead to macrophage-driven adverse local tissue reactions, which have been linked to an increased risk of periprosthetic joint infection after revision arthroplasty. While metal-induced cytotoxicity is well characterized in human macrophages, direct effects on their functionality have remained elusive. Synchrotron radiation X-ray microtomography and X-ray fluorescence mapping indicated that peri-implant tissues harvested during aseptic revision of different arthroplasty implants are exposed to Co and Cr in situ. Confocal laser scanning microscopy revealed that macrophage influx is predominant in patient tissue. While in vitro exposure to Cr3+ had only minor effects on monocytes/macrophage phenotype, pathologic concentrations of Co2+ significantly impaired both, monocyte/macrophage phenotype and functionality. High concentrations of Co2+ led to a shift in macrophage subsets and loss of surface markers, including CD14 and CD16. Both Co2+ and Cr3+ impaired macrophage responses to Staphylococcus aureus infection, and particularly, Co2+-exposed macrophages showed decreased phagocytic activity. These findings demonstrate the immunosuppressive effects of locally elevated metal ions on the innate immune response and support further investigations, including studies exploring whether Co2+ and Cr3+ or CoCrMo alloys per se expose the patients to a higher risk of infections post-revision arthroplasty.
- 14 June 2023
- Published by Springer Nature
- p. 1-21
Grundlagen des Hüftgelenkersatzes: Biologische Reaktionen auf Abrieb
- 14 June 2023
- Published by Springer Nature
- p. 1-21
Grundlagen des Hüftgelenkersatzes: Biologische Reaktionen auf Abrieb
- Open Access
- 28 March 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (4) , 592
Clinical and Radiological Outcome of Disc Arthroplasty for the Treatment of Cervical Spondylotic Myelopathy
Introduction: The aim of this study is to evaluate the clinical and radiological results of cervical disc arthroplasty (CDA) in patients with cervical spondylotic myelopathy (CSM) using the CP ESP® disc prosthesis. Materials and Methods: Prospectively collected data of 56 patients with CSM have been analyzed. The mean age at surgery was 35.6 years (range: 25–43 years). The mean follow-up was 28.2 months (range: 13–42 months). The range of motion (ROM) of the index segments, as well as upper and lower adjacent segments, was measured before surgery and at final follow-up. The C2-C7 sagittal vertical axis (SVA), C2-C7 cervical lordosis (CL), and T1 slope minus cervical lordosis (T1s-CL) were analyzed as well. Pain intensity was measured preoperatively and during follow-up using an 11-point numeric rating scale (NRS). Modified Japanese Orthopaedic Association (mJOA) score was assessed preoperatively and during follow-up for the clinical assessment of myelopathy. Surgical and implant-associated complications were analyzed as well. Results: The NRS pain score improved from a mean of 7.4 (±1.1) preoperatively to a mean of 1.5 (±0.7) at last follow-up (p < 0.001). The mJOA score improved from a mean of 13.1 (±2.8) preoperatively to a mean of 14.8 (±2.3) at last follow-up (p < 0.001). The mean ROM of the index levels increased from 5.2° (±3.0) preoperatively to 7.3° (±3.2) at last follow-up (p < 0.05). Four patients developed heterotopic ossifications during follow-up. One patient developed permanent dysphonia. Conclusions: CDA showed good clinical and radiological outcome in this cohort of young patients. The motion of index segments could be preserved. CDA may be a viable treatment option in selected patients with CSM.
- 28 March 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (4) , 592
Open AccessClinical and Radiological Outcome of Disc Arthroplasty for the Treatment of Cervical Spondylotic Myelopathy
Introduction: The aim of this study is to evaluate the clinical and radiological results of cervical disc arthroplasty (CDA) in patients with cervical spondylotic myelopathy (CSM) using the CP ESP® disc prosthesis. Materials and Methods: Prospectively collected data of 56 patients with CSM have been analyzed. The mean age at surgery was 35.6 years (range: 25–43 years). The mean follow-up was 28.2 months (range: 13–42 months). The range of motion (ROM) of the index segments, as well as upper and lower adjacent segments, was measured before surgery and at final follow-up. The C2-C7 sagittal vertical axis (SVA), C2-C7 cervical lordosis (CL), and T1 slope minus cervical lordosis (T1s-CL) were analyzed as well. Pain intensity was measured preoperatively and during follow-up using an 11-point numeric rating scale (NRS). Modified Japanese Orthopaedic Association (mJOA) score was assessed preoperatively and during follow-up for the clinical assessment of myelopathy. Surgical and implant-associated complications were analyzed as well. Results: The NRS pain score improved from a mean of 7.4 (±1.1) preoperatively to a mean of 1.5 (±0.7) at last follow-up (p < 0.001). The mJOA score improved from a mean of 13.1 (±2.8) preoperatively to a mean of 14.8 (±2.3) at last follow-up (p < 0.001). The mean ROM of the index levels increased from 5.2° (±3.0) preoperatively to 7.3° (±3.2) at last follow-up (p < 0.05). Four patients developed heterotopic ossifications during follow-up. One patient developed permanent dysphonia. Conclusions: CDA showed good clinical and radiological outcome in this cohort of young patients. The motion of index segments could be preserved. CDA may be a viable treatment option in selected patients with CSM.