DWDongfang Wang

Dongfang Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dongfang Wang has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Percutaneous Cavopulmonary Assist: From Design to 96 Hour Survival in Lethal Cavopulmonary Failure Sheep

    by Li Li, Jingkun Wang, Guangfeng Zhao, Stephen Topaz, David Morales, Ajit Yoganathan, Cherry Ballard-Croft, Joseph B. Zwischenberger, Dongfang Wang

    We are developing a clinically practical percutaneous double lumen cannula (DLC)–based cavopulmonary assist (CPA) system to support failing Fontan patients. In this study, our CPA DLC was redesigned for even blood flow, minimal recirculation, and easy insertion/deployment. After bench testing, this new CPA system was evaluated for 4 hours (n = 10) and 96 hours (n = 5) in our clinically relevant lethal cavopulmonary failure (CPF) sheep model for ease of cannulation/deployment, reversal of CPF hemodynamics/end-organ hypoperfusion, and durability/biocompatibility. Cavopulmonary failure was achieved in all sheep. All DLCs were successfully inserted/deployed into Fontan anatomy. Cavopulmonary assist reversed CPF with normalized central venous pressure and cardiac output. All survival sheep were ambulatory with normal eating/drinking. One sheep was euthanized after 6 hours from cannula kinking, and one sheep died of hypokalemia after 8 hours. Three sheep survived 96 hours with normal hemodynamics. Free hemoglobin was only 3.7 ± 1.2 mg/dl at 96 hours, indicating negligible hemolysis. Creatinine, blood urea nitrogen, and lactate increased from hypoperfusion but normalized by 72 hours CPA. Necropsy showed only a small, immobilized thrombus ring at umbrella attachment to DLC. Our DLC-based system provided total ambulatory CPA in a lethal CPF sheep model with 96 hour survival and complete reversal of hemodynamics and end-organ hypoperfusion.


  • Open Access

    Identification of an Eight-lncRNA Signature as the Prognostic lncRNA Markers in Hepatocellular Carcinoma Patients

    by Sixu Li, Weiping Zeng, Dongfang Wang, Keai Sinn Tan, Wen Tan, Gu Li

    Long non-coding RNA (lncRNA) signature has been reputable for the predetermination of cancer prognosis. In the present study, we constructed a lncRNA model to predict the survival outcomes for hepatocellular carcinoma (HCC) patients. Using the transcriptome data from TCGA HCC samples, we identified that NEAT1 and MALAT1 were highly expressed in HCC and other tumor subtypes compared to the adjacent normal tissues. Based on the LASSO Cox regression model, we identified an eight-lncRNA signature that significantly correlated with the overall survival and disease-free survival of the HCC training group. The prognostic value of this signature was validated using the test group. Further analysis suggested that this signature was associated with the clinicopathological parameters such as vascular tumor invasion, pathological stage, and tumor grade. Integrated functional analysis showed that these eight-lncRNAs were involved in the cell cycle, metabolic process, and immune response. In conclusion, we constructed an applicable eight-lncRNA signature that is robust and reliable for the prognosis of HCC. This signature may provide an efficient clinical prediction for HCC patients, and further study is required to uncover the function of the identified lncRNAs better.

  • Open Access

    Evaluation of Recirculation During Venovenous Extracorporeal Membrane Oxygenation Using Computational Fluid Dynamics Incorporating Fluid-Structure Interaction

    by Steven A. Conrad, Dongfang Wang

    Recirculation in venovenous extracorporeal membrane oxygenation (VV ECMO) leads to reduction in gas transfer efficiency. Studies of the factors contributing have been performed using in vivo studies and computational models. The fixed geometry of previous computational models limits the accuracy of results. We have developed a finite element computational fluid dynamics model incorporating fluid-structure interaction (FSI) that incorporates atrial deformation during atrial filling and emptying, with fluid flow solved using large eddy simulation. With this model, we have evaluated an extensive number of factors that could influence recirculation during two-site VV ECMO, and characterized their impact on recirculation, including cannula construction, insertion depth and orientation, VV ECMO configuration, circuit blood flow, and changes in volume, venous return, heart rate, and blood viscosity. Simulations revealed that extracorporeal blood flow relative to cardiac output, ratio of superior vena caval (SVC) to inferior vena caval (IVC) blood flow, position of the SVC cannula relative to the cavo-atrial junction, and orientation of the return cannula relative to the tricuspid valve had major influences (>20%) on recirculation fraction. Factors with a moderate influence on recirculation fraction (5%–20%) include heart rate, return cannula diameter, and direction of extracorporeal flow. Minimal influence on recirculation (<5%) was associated with atrial volume, position of the IVC cannula relative to the cavo-atrial junction, the number of side holes in the return cannula, and blood viscosity.


  • Open Access

    Biplane Angiography for Experimental Validation of Computational Fluid Dynamic Models of Blood Flow in Artificial Lungs

    by Cameron C. Jones, Patrizio Capasso, James M. McDonough, Dongfang Wang, Kyle S. Rosenstein, Joseph B. Zwischenberger

    This article presents an investigation into the validation of velocity fields obtained from computational fluid dynamic (CFD) models of flow through the membrane oxygenators using x-ray digital subtraction angiography (DSA). Computational fluid dynamic is a useful tool in characterizing artificial lung devices, but numerical results must be experimentally validated. We used DSA to visualize flow through a membrane oxygenator at 2 L/min using 37% glycerin at 22°C. A Siemens Artis Zee system acquired biplane x-ray images at 7.5 frames per second, after infusion of an iodinated contrast agent at a rate of 33 ml/s. A maximum cross-correlation (MCC) method was used to track the contrast perfusion through the fiber bundle. For the CFD simulations, the fiber bundle was treated as a single momentum sink according to the Ergun equation. Blood was modeled as a Newtonian fluid, with constant viscosity (3.3 cP) and density (1050 kg/m3). Although CFD results and experimental pressure measurements were in general agreement, the simulated 2 L/min perfusion did not reproduce the flow behavior seen in vitro. Simulated velocities in the fiber bundle were on average 42% lower than experimental values. These results indicate that it is insufficient to use only pressure measurements for validation of the flow field because pressure-validated CFD results can still significantly miscalculate the physical velocity field. We have shown that a clinical x-ray modality, together with a MCC tracking algorithm, can provide a nondestructive technique for acquiring experimental data useful for validation of the velocity field inside membrane oxygenators.


  • Complete Respiratory Support with AVCO2R and CPAP-Mimic Ventilation for Total Gas Exchange in Sheep

    by Don Jr. Hayes, Joseph B. Zwischenberger, Xiaoqin Zhou, Xiaojun Liu, James E. Lynch, Cherry Ballard-Croft, Dongfang Wang

    The altered respiratory mechanics in patients with chronic obstructive pulmonary disease (COPD) present unique challenges with regard to treatment during an acute exacerbation that often leads to respiratory support with mechanical ventilation. Alternative therapies are badly needed to reduce morbidity and mortality associated with mechanical ventilator use. We hypothesized that arteriovenous carbon dioxide removal (AVCO2R) coupled with continuous positive airway pressure (CPAP) would achieve total gas exchange eliminating the need for intubation/mechanical ventilation, thus reducing baro/volutrauma. This hypothesis was tested in six adult sedated apneic sheep with AVCO2R administered through a simple arteriovenous (AV) shunt for CO2 removal. Because it is impractical to apply a CPAP mask to conscious sheep, the CPAP was mimicked in intubated/sedated sheep by positive end-expiratory pressure (PEEP) of 5–10 mmH2O with negligible ventilation. The AVCO2R and CPAP-mimic maintained Pao2 and Paco2 in the normal physiological ranges. The CO2 removal was 120–150 ml/min through AVCO2R with AV blood flow of 1.1–1.5 L/min. A high fraction of inspired oxygen percentage (Fio2) level (89 ± 3%) was required to achieve 40 ± 7% O2 in the small bronchus. Thus, AVCO2R and CPAP-mimic achieved total gas exchange in anesthetized sheep and may be a potential option for acute COPD exacerbation in humans.

  • A Pulmonary Hypertension Model Induced by Continuous Pulmonary Air Embolization

    by Xiaoqin Zhou, Dongfang Wang, Claudia Y. Castro, Hal Hawkins, James E. Lynch, Xiaojun Liu, Joseph B. Zwischenberger


  • Numerical and Experimental Flow Analysis of the Wang-Zwische Double-Lumen Cannula

    by Carmine De Bartolo, Alessandra Nigro, Gionata Fragomeni, Francesco M. Colacino, Dongfang Wang, Cameron C. Jones, Joseph Zwischenberger

    An experimental and numerical analysis was performed for the Wang-Zwische double-lumen cannula (DLC) (Avalon Elite). The aim of this work was to provide insight for future improvement by characterizing the fluid dynamic behavior of the novel catheter with metrics often associated with blood trauma. Pressure and flow distributions were measured on a steady-flow rig using a 50% glycerol-water mixture by imposing a 2 L/min flow rate across the drainage and infusion lumens. The fluid was modeled as Newtonian with density of 1050 kg/m3 and dynamic viscosity of 0.0035 kg/m·s. Reynolds numbers typical for transitional flow (Re = 2000–2500) were computed within the lumens because of the changing cross-sections of the cannula geometry. Numerical computations were performed using the steady three-dimensional Reynolds-averaged Navier-Stokes (RANS) equations and the low-Reynolds k-ω turbulence model. Discretization of governing equations was based on a cell-centered finite volume method. Numerical results correlated well with global performance of the cannula, allowing evaluation of the geometry toward potential blood trauma. Peak wall shear stress (WSS) in the drainage lumen was higher than that of infusion lumen, mainly due to the presence of side holes. Furthermore, recirculation regions were predicted in transition tubing to connectors of both the drainage and the infusion lumens because of adverse pressure gradients caused by the sudden enlargement of the cannula geometry. In this three-dimensional computational fluid dynamics (CFD) study, we observed higher peak WSS values for the drainage lumen, which may potentially cause blood trauma. Furthermore, recirculation regions were predicted in the proximity of the exit sections of both the infusion and drainage lumens, which may contribute to thrombosis formation. This study provides insight for future DLC modifications in minimizing cannula-induced blood trauma and thrombogenicity in long-term applications.