Sha-Sha Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sha-Sha Song has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Fei Gao
Key Laboratory of Materials Modification by Laser, Ion, and Electron Beams (Ministry of Education), School of Physics, Dalian University of Technology 1 , Dalian 116024
2 shared publications - Wei Liu
Department of Experimental and Practical Teaching Management, West Anhui University 3 , Lu'an 237012
2 shared publications - Yong-Xin Liu
Dalian University of Technology
2 shared publications - Yongtao Zhao
Xi'an Jiaotong University
2 shared publications - You-Nian Wang
School of Physics, Dalian University of Technology 1 , Dalian 116024
2 shared publications - Jianxiang Zhang
Shaanxi International Joint Research Center for Applied Technology of Controllable Neutron Source, Xijing University 1 , Xi'an 710123
1 shared publication
Latest Publications
- Open Access
- 1 August 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (8)
Improving plasma uniformity in the inductively coupled plasma by external magnetic field
To enhance etching efficiency and uniformity in process production, in this work, a two-dimensional fluid model was used to study the modulation effect of an external magnetic field on the argon–oxygen inductively coupled plasma (ICP). The study found that as the magnetic coil current increases, the electron density changes from center-high to uniform to edge-high distribution. The best plasma uniformity degree is 94%, obtained at a magnetic coil current of 10 A, which represents a 39% improvement over the unmagnetized ICP. The electric field reversal occurs during the transition from weak magnetization to strong magnetization. The electron temperature shows a single-peak to dual-peak to single-peak distribution during this period. In addition, we also found that gas pressure and oxygen ratio also impact magnetized plasma, where the effect of gas pressure on magnetized plasma is more significant than that of oxygen ratio. The results show that introducing an external magnetic field can significantly improve the plasma density and radial uniformity. This finding has contributed to enhancing plasma etching uniformity and optimizing etching processes.
- 1 August 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (8)
Open AccessImproving plasma uniformity in the inductively coupled plasma by external magnetic field
To enhance etching efficiency and uniformity in process production, in this work, a two-dimensional fluid model was used to study the modulation effect of an external magnetic field on the argon–oxygen inductively coupled plasma (ICP). The study found that as the magnetic coil current increases, the electron density changes from center-high to uniform to edge-high distribution. The best plasma uniformity degree is 94%, obtained at a magnetic coil current of 10 A, which represents a 39% improvement over the unmagnetized ICP. The electric field reversal occurs during the transition from weak magnetization to strong magnetization. The electron temperature shows a single-peak to dual-peak to single-peak distribution during this period. In addition, we also found that gas pressure and oxygen ratio also impact magnetized plasma, where the effect of gas pressure on magnetized plasma is more significant than that of oxygen ratio. The results show that introducing an external magnetic field can significantly improve the plasma density and radial uniformity. This finding has contributed to enhancing plasma etching uniformity and optimizing etching processes.
- 1 July 2021
- Published by AIP Publishing in Physics of Plasmas
- Vol. 28 (7) , 073512
Two-dimensional spatial distribution and production mechanism of H− ions in cylindrical inductively coupled H2 discharges
In this work, radio frequency (RF) inductively coupled hydrogen plasmas have been investigated using a two-dimensional (2D) hybrid model, consisting of a fluid module and an electromagnetic field module. This paper focuses on the effects of driver chamber radius, RF power, and gas pressure on the spatial distribution of H− density. The results show that H− ions are produced all over the driver chamber and exhibit a strong accumulation in the plasma center. Furthermore, this accumulation becomes much stronger with a smaller radius, due to the larger dc electric field intensity. While the H− density in the plasma center first increases and then decreases with the increasing radius. This is because the total production rate of H− has an opposite tendency to that of the dc electric field intensity. Therefore, the spatial distribution of the H− is governed by the dc electric field and the production mechanism. In addition, the accumulated area of H− at different powers is nearly invariable, whereas it spreads out with pressure. This can be attributed to the different spatial profiles of the dc electric field. To validate our model, the calculated electron density is compared with the experimental result, and a reasonable agreement is achieved. Hopefully, the results in this work could lead to a deeper insight into the variations of the spatial distribution of H− density on the driver chamber radius and discharge conditions, which is very important in the design of a high efficiency and compact negative hydrogen ion beam source.
- 1 July 2021
- Published by AIP Publishing in Physics of Plasmas
- Vol. 28 (7) , 073512
Two-dimensional spatial distribution and production mechanism of H− ions in cylindrical inductively coupled H2 discharges
In this work, radio frequency (RF) inductively coupled hydrogen plasmas have been investigated using a two-dimensional (2D) hybrid model, consisting of a fluid module and an electromagnetic field module. This paper focuses on the effects of driver chamber radius, RF power, and gas pressure on the spatial distribution of H− density. The results show that H− ions are produced all over the driver chamber and exhibit a strong accumulation in the plasma center. Furthermore, this accumulation becomes much stronger with a smaller radius, due to the larger dc electric field intensity. While the H− density in the plasma center first increases and then decreases with the increasing radius. This is because the total production rate of H− has an opposite tendency to that of the dc electric field intensity. Therefore, the spatial distribution of the H− is governed by the dc electric field and the production mechanism. In addition, the accumulated area of H− at different powers is nearly invariable, whereas it spreads out with pressure. This can be attributed to the different spatial profiles of the dc electric field. To validate our model, the calculated electron density is compared with the experimental result, and a reasonable agreement is achieved. Hopefully, the results in this work could lead to a deeper insight into the variations of the spatial distribution of H− density on the driver chamber radius and discharge conditions, which is very important in the design of a high efficiency and compact negative hydrogen ion beam source.
- 1 September 2020
- Published by AIP Publishing in Physics of Plasmas
- Vol. 27 (9) , 093512
Numerical investigation of ion energy and angular distributions in a dc-biased H2 inductively coupled discharge
The ion energy and angular distributions of H+, , and impinging on an extraction aperture (3 mm in radius) have been investigated with a hybrid model of an inductively coupled H2 ion source. A dc is applied at the end of the cylinder discharge chamber, which pulls these three ions toward the extraction aperture. With an increase in the bias voltage, their ion angular distributions (IADs) become more symmetrical about the 0° axis and the full width at half-maximum (FWHM) of their IADs shrinks continuously. On the other hand, the ion-energy distributions (IEDs) of the three ions first form a single peak ( 50 V) and then have a bimodal structure at 50 V 290 V. Finally, they return to a single peak at high bias voltage ( 290 V). The interval between two IED peaks ( ) first increases to a maximum around 150 V and then decreases monotonously. This can be attributed to the variation of the ratio of the ion transit time through the sheath (τi) to the rf field period (τrf). Moreover, the FWHMs of IEDs of H+, , and first increase to 2.62, 2.45, and 2.32 eV around Vbias = 150 V, respectively, and then decrease continuously with the bias voltage. Using a low rf power and low gas pressure may help to narrow the FWHM of the IEDs of the three ions. The hybrid model is verified by comparing the results from the simulation and experiment, and they exhibit a qualitative agreement. The results in this work could lead to deeper insights into the dependence of IADs and IEDs on the discharge parameters, which is important for realizing a monoenergetic and collimated ion beam in a proton or an ion accelerator.- 1 September 2020
- Published by AIP Publishing in Physics of Plasmas
- Vol. 27 (9) , 093512
Numerical investigation of ion energy and angular distributions in a dc-biased H2 inductively coupled discharge
The ion energy and angular distributions of H+, , and impinging on an extraction aperture (3 mm in radius) have been investigated with a hybrid model of an inductively coupled H2 ion source. A dc is applied at the end of the cylinder discharge chamber, which pulls these three ions toward the extraction aperture. With an increase in the bias voltage, their ion angular distributions (IADs) become more symmetrical about the 0° axis and the full width at half-maximum (FWHM) of their IADs shrinks continuously. On the other hand, the ion-energy distributions (IEDs) of the three ions first form a single peak ( 50 V) and then have a bimodal structure at 50 V 290 V. Finally, they return to a single peak at high bias voltage ( 290 V). The interval between two IED peaks ( ) first increases to a maximum around 150 V and then decreases monotonously. This can be attributed to the variation of the ratio of the ion transit time through the sheath (τi) to the rf field period (τrf). Moreover, the FWHMs of IEDs of H+, , and first increase to 2.62, 2.45, and 2.32 eV around Vbias = 150 V, respectively, and then decrease continuously with the bias voltage. Using a low rf power and low gas pressure may help to narrow the FWHM of the IEDs of the three ions. The hybrid model is verified by comparing the results from the simulation and experiment, and they exhibit a qualitative agreement. The results in this work could lead to deeper insights into the dependence of IADs and IEDs on the discharge parameters, which is important for realizing a monoenergetic and collimated ion beam in a proton or an ion accelerator.