Gongde Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gongde Xu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Yang Liu
School of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China
2 shared publications - Yuanyuan Sun
Shandong University
2 shared publications - Zhen Liu
Shandong University
2 shared publications Lina Zhang
China National Offshore Oil Corporation, Beijing, China
1 shared publication- Lisheng Li
State Grid Shandong Electric Power Research Institute, Jinan 250003, China
1 shared publication - Lisheng Li
State Grid Shandong Electric Power Company
1 shared publication
Latest Publications
- 3 September 2022
- Published by Springer Nature
- p. 705-712
Dynamic Harmonic Analysis of Electric Energy Routers with Common High Frequency Bus Under Multi-Source-Load Interaction
- 3 September 2022
- Published by Springer Nature
- p. 705-712
Dynamic Harmonic Analysis of Electric Energy Routers with Common High Frequency Bus Under Multi-Source-Load Interaction
- 3 September 2022
- Published by Springer Nature
- p. 3-10
Study on the Influence of Parasitic Parameters on the Switching Characteristics and High Frequency Oscillation of SiC MOSFET
- 3 September 2022
- Published by Springer Nature
- p. 3-10
Study on the Influence of Parasitic Parameters on the Switching Characteristics and High Frequency Oscillation of SiC MOSFET
- Open Access
- 12 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 102422-102432
Partial Discharge Pattern Recognition of Transformers Based on the Gray-Level Co-Occurrence Matrix of Optimal Parameters
The partial discharge (PD) is the most common fault of transformers, which is the main factor affecting the stable operation of transformers. Therefore, the PD should be monitored and identified timely to improve the reliability of the transformers. In this paper, a transformer PD pattern recognition algorithm based on the gray-level co-occurrence matrix of optimal parameters and support vector machine (GLCMOP-SVM) is proposed. Firstly, the GLCM of optimal parameters (GLCMOP) is proposed to be determined by calculating the proportion of the off-diagonal elements (PODE) in GLCM. The GLCMOP has the advantage of avoiding the subjectivity of parameter selection and simplifying the calculation process. Then, the phase-resolved partial discharge (PRPD) maps are used as the PD samples and are converted into the GLCMOP to extract the PD features. Moreover, the feature space of the GLCMOP is dimensionally reduced by screening out the features with high distinguishability, which can improve the generalization ability and recognition speed of the classifier. Finally, the SVM classifier is trained to sort the PD samples and recognize the PD types, which include the tip discharge, surface discharge, and air discharge PD types. Lab tests are performed to verify the accuracy and validity of the proposed methodology. Compared with the traditional algorithms based on GLCM, XGBoost (eXtreme Gradient Boosting) and artificial neural network (ANN), the performance of GLCMOP-SVM is better. The GLCMOP-SVM has less memory consumption and faster recognition speed, so it is very suitable for the online and real-time monitoring of PD occurred in the transformers.
- 12 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 102422-102432
Open AccessPartial Discharge Pattern Recognition of Transformers Based on the Gray-Level Co-Occurrence Matrix of Optimal Parameters
The partial discharge (PD) is the most common fault of transformers, which is the main factor affecting the stable operation of transformers. Therefore, the PD should be monitored and identified timely to improve the reliability of the transformers. In this paper, a transformer PD pattern recognition algorithm based on the gray-level co-occurrence matrix of optimal parameters and support vector machine (GLCMOP-SVM) is proposed. Firstly, the GLCM of optimal parameters (GLCMOP) is proposed to be determined by calculating the proportion of the off-diagonal elements (PODE) in GLCM. The GLCMOP has the advantage of avoiding the subjectivity of parameter selection and simplifying the calculation process. Then, the phase-resolved partial discharge (PRPD) maps are used as the PD samples and are converted into the GLCMOP to extract the PD features. Moreover, the feature space of the GLCMOP is dimensionally reduced by screening out the features with high distinguishability, which can improve the generalization ability and recognition speed of the classifier. Finally, the SVM classifier is trained to sort the PD samples and recognize the PD types, which include the tip discharge, surface discharge, and air discharge PD types. Lab tests are performed to verify the accuracy and validity of the proposed methodology. Compared with the traditional algorithms based on GLCM, XGBoost (eXtreme Gradient Boosting) and artificial neural network (ANN), the performance of GLCMOP-SVM is better. The GLCMOP-SVM has less memory consumption and faster recognition speed, so it is very suitable for the online and real-time monitoring of PD occurred in the transformers.