QCQiang Chen

Qiang Chen

*This is an algorithmically generated author record based on publicly available information.

Qiang Chen has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Photoelectric Composite Three-Phase Flow Sensor for Complex Oil and Gas Wells

    by Qiang Chen, Xueguang Qiao, Tao Chen, Hong Gao, Congcong Li

    Reliable measurement of multiphase flow is fundamental to production evaluation in complex oil and gas wells. However, conventional sensors often suffer from low integration, limited measurement capability, and potential environmental impact. To address these challenges, a photoelectric composite three-phase flow sensor is developed, integrating multiple electrode rings for water holdup and liquid-phase velocity measurement, with dual optical-fiber probes for gas holdup and gas-phase velocity detection. A slip model is further applied to quantify the dependence of slip velocity on liquid holdup based on measured phase rates. Experimental results demonstrate high sensitivity to bubble-flow structures, accurate extraction of gas holdup and phase velocities, and stable full-range water holdup calibration from 0% to 100% at 5 V and 15 V with effective temperature and salinity compensation. And compared with existing technologies, the sensor designed in this paper has the advantages of high integration, a simple structure, multiple measurement parameters, and higher water-holding capacity resolution in low-saturation areas, providing more advanced technical means for conventional profile three-phase flow logging.

  • Open Access

    Application of Attention Mechanism Models in the Identification of Oil–Water Two-Phase Flow Patterns

    by Qiang Chen, Haimin Guo, Xiaodong Wang, Yuqing Guo, Jie Liu, Ao Li, Yongtuo Sun, Dudu Wang

    Accurate identification of oil–water two-phase flow patterns is essential for ensuring the safety and operational efficiency of oil and gas extraction systems. While traditional methods using empirical models and sensor technologies have provided basic insights, they often struggle to capture the nonlinear features of complex operational conditions. To address the challenge of data scarcity commonly found in experimental settings, this study employs a data augmentation strategy that combines the Synthetic Minority Over-sampling Technique (SMOTE) with Gaussian noise injection, effectively expanding the feature space from 60 original experimental nodes. Next, a physics-constrained attention mechanism model was developed that incorporates a physical constraint matrix to effectively mask irrelevant feature interactions. Experimental results show that while the standard attention model (83.88%) and the baseline BP neural network (84.25%) have limitations in generalizing to complex regimes, the proposed physics-constrained model achieves a peak test accuracy of 96.62%. Importantly, the model demonstrates exceptional robustness in identifying complex transition regions—specifically Dispersed Oil-in-Water (DO/W) flows—where it improved recall rates by about 24.6% compared to baselines. Additionally, visualization of attention scores confirms that the distribution of attention weights aligns closely with fluid-dynamic mechanisms—favoring inclination for stratified flows and flow rate for turbulence-dominated dispersions—thus validating the model’s interpretability. This research offers a novel, interpretable approach for modeling dynamic feature interactions in multiphase flows and provides valuable insights for intelligent oilfield development.


  • Development of a Torque-Based Correction Model for Array Turbine Flowmeters in Inclined Gas Wells With Liquid Loading

    by Zhengyan Wang, Meng Chen, Wenhui Chen, Tao Chen, Guoquan Liu, Qiang Chen, Guofeng Yang, Guoqiang Hou

    Liquid loading in horizontal/inclined gas wells challenges unconventional reservoir development globally. Accurate gas-water velocity and holdup monitoring is crucial for dynamic evaluation. This study simulates flow using a 10-m-long, 120-mm-ID inclined pipe (70°) at Southwest Petroleum University. Air ( $\rho_{g}=1.21 \mathrm{~kg} / \mathrm{m}^{3}, \mu_{g}=0.018 \mathrm{mPa} \cdot \mathrm{s}$ ) and water ( $\rho_{w}=0.997 \times 10^{3} \mathrm{~kg} / \mathrm{m}^{3}, \mu_{w}=1.002 \mathrm{mPa} \cdot \mathrm{s}$ ) served as media, with total flow rates of 50-500 m3/d and water content of 0%-100%. Capacitance Array Tool (CAT) and Spinner Array Tool (SAT) monitored holdup and velocity under stable conditions, while cameras recorded phase distribution. Flow regimes were primarily slug flow and elongated bubble (EB) flow. Significant probe response variations indicated uneven phase distribution. A torque model for the two-phase flow of gas and water was established, and the slip ratio was introduced to calculate the total flow rate of gas and water in the wellbore on the basis of the response of the array spinners. Validation against 54 experimental datasets showed superior performance over traditional momentum models. Mean relative error (MRE): 11% versus 20%; root mean square error (RMSE): 1.36 versus 2.86; and coefficient of determination ( $R^{2}$ ): 0.97 versus 0.90. The model demonstrates effective application for intermittent flows in deviated wells, enabling high-precision production logging interpretation in unconventional gas reservoirs.


  • An Optical Fiber Multiphase Flow Sensor Based on Identification of Bubble Collision and Bounce

    by Tianxi Zhang, Ruohui Wang, Ming Ding, Qiang Chen, Dan Su, Xueguang Qiao

    In this paper, we proposed a Fiber Bragg Grating (FBG) based on identification of bubble collision and bounce. The FBG target sensor detects the vibration signal resulting from the multiple rebound motions of the bubble after colliding with the target. The tension, diameter, and velocity of the bubbles are related to the frequency and amplitude of the vibration signal. In the test of a single target sensor, the frequency of air bubbles is measured to be within the range of 80-100 Hz which is higher than the frequency of oil bubbles within the range of 0-10 Hz. An annular sensing array based on a 3D printed structure is also demonstrated for measuring the cross-sectional bubbles passing through the pipeline. The proposed sensor introduces a new multiphase sensing principle, paving a way for optical fiber holdup sensor development.


  • An FBG Temperature–Pressure Sensor Based on Diaphragm and Special-Shaped Bracket Structure

    by Dequan Feng, Dongpo Xu, Fengyi Chen, Qiang Chen, Xueguang Qiao

    A fiber Bragg grating (FBG) sensor capable of simultaneous temperature-pressure measurement is presented and experimentally verified, which consists of a diaphragm, a special-shaped bracket, dual FBGs and a protective housing. The principle of simultaneous temperature and pressure measurement with dual FBGs is theoretically illustrated and simulated by finite element analysis. The experimentally investigated results demonstrate that the sensor can be employed to measure temperature and pressure in environments where the temperature ranges from 50 °C to 200 °C and the pressure ranges from 0 MPa to 40 MPa. The temperature sensitivity of the sensor is 31.8 pm/°C with a linear correlation coefficient of 0.9997; the pressure sensitivity is 50.6 pm/MPa, linearity is 0.21%, repeatability and hysteresis error are 0.024% and 0.16% respectively. The sensor exhibits a large measuring range, high temperature resistance, miniaturized structure and easily multiplexed, which allows it for temperature and pressure dual parametric measurements in high temperature and high pressure environments such as oil and gas wells.


  • Compact-Packaged and Diaphragm-Lever Structured Fiber-Optic Temperature and Pressure Sensors for Oil and Gas Well Applications

    by Dongpo Xu, Dequan Feng, Qiang Chen, Dongkai Huo, Xueguang Qiao

    A small-sized sensor combined with a diaphragm structure and a lever structure is proposed for application in high temperature and high pressure environments. The feasibility of the structure is verified from both theory and simulation, and the relationship between the change of the Bragg wavelength and the pressure is established. Differential measurements of temperature and pressure are achieved using two FBGs. The experimental data show that the pressure sensitivity of the sensor is 28.86 pm/MPa in the range of 0-30 MPa, and the correlation coefficient is 0.9969. The pressure sensitivity of the improved structure is 29.76 pm/MPa and the correlation coefficient is 0.9999. The sensor’s temperature sensitivity is 32.66 pm/°C in the range of 50-200 °C. The structure can be applied to the measurement of temperature and pressure in oil and gas wells.


  • Open Access

    Instrument Design for Detecting the Inner Damage of Casing

    by Tao Guo, Yong Wei, Ke Li, Qiang Chen, Li Yan, Jiefu Chen

    Detecting and localizing the inner damage of the downhole casing is crucial for oil and gas production. The current methods for damage detection suffer from polarization effect, capacitance effect, and difficulty in measuring weak direct current signals. As an alternative, we propose a new instrument design based on a six-electrode array in this study. The basic detection principle is introduced, and the key factors that affect the detection performance are studied through modeling and simulation. Besides, the entire system of the instrument design consisting of several modules is presented. In addition, an experiment is conducted to demonstrate the detection capability of the proposed design. It is found that the detection dynamic of the instrument is 93 dB and a signal-to-noise ratio is 73 dB. It can detect damage when salinity is lower than 120 g/l and can identify the location of damage with high resolution in the longitudinal and radial directions.


  • Open Access

    A Novel Conical Spiral Transmission Line Sensor-Array Water Holdup Detection Tool Achieving Full Scale and Low Error Measurement

    by Yong Wei, Houquan Yu, Qiang Chen, Guoquan Liu, Chaoxian Qi, Jiefu Chen

    To dynamically monitor the horizontal well, we studied the oil–water two-phase water holdup detection method based on transmission lines, and designed a micro-sensor and a sensor-array water holdup detection tool. We modeled the relationship of the dielectric constant of the transmission line filling medium and the amplitude and phase shift of the electromagnetic wave signal on the transmission line by using the time-domain analysis. We proposed a novel method to measure the water holdup of oil–water mixtures based on the phase shift of signals on the conical spiral transmission line. Furthermore, we simulated and optimized the structural parameters by software simulation, and developed a small conical spiral water holdup sensor suitable for arraying. The single sensor with detection circuits can achieve the full scale (water holdup from 0% to 100%) measurement with resolution better than 3%. On this basis, 12 sensors are used to develop a clock-like sensor-array water holdup detection tool, realizing the array detection of the distribution of the cross-section medium in horizontal wells.