Hao Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hao Zhang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Chih-Yung Wen
The Hong Kong Polytechnic University
2 shared publications An-Shik Yang
1 shared publication- Chun Wah Leung
School of Professional Education and Executive Development, The Hong Kong Polytechnic University, Hong Kong, China
1 shared publication - Hongxing Yang
The Hong Kong Polytechnic University
1 shared publication - Jian Wang
Huazhong University of Science and Technology
1 shared publication - Kai Ming Tsang
Department of Electrical Engineering, The Hong Kong Polytechnic University, Hong Kong, China
1 shared publication
Latest Publications
- Open Access
- 9 September 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (18) , 13511
Optimization of the Liquid Desiccant Cooling Systems in Hot and Humid Areas
Air-conditioning systems in hot and humid regions account for over 50% of total energy usage. Integrating an indirect evaporative cooling () and a liquid desiccant dehumidifier () as the liquid desiccant cooling system () presents an energy-saving and emission-reducing solution to replace traditional mechanical vapor compression refrigeration () systems. This integration overcomes the regional limitations of IEC in hot and humid areas. The newly developed uses exhaust air as the working air source and solar energy as the heat source for desiccant solution regeneration. This study aims to develop an empirical model for the outlet parameters of the , propose an optimization strategy for its operating parameters, and assess the potential and energy performance through parameter analysis and multifactor optimization. By conducting sensitivity analysis and optimizing six critical parameters based on a response surface model (), the system outlet temperature, relative humidity, and coefficient of performance () are improved as the optimization objectives. The regional capability is demonstrated in three selected hot and humid cities. The results indicate that the can significantly increase the by 57.3%. Additionally, it can meet the dehumidification demand when operating with 25% of the air extracted in the during months with high humidity and temperature. This study will facilitate the application of and technologies, guide the design and operation scheme of the system, and promote energy-saving and emission-reducing solutions in hot and humid regions.- 9 September 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (18) , 13511
Open AccessOptimization of the Liquid Desiccant Cooling Systems in Hot and Humid Areas
Air-conditioning systems in hot and humid regions account for over 50% of total energy usage. Integrating an indirect evaporative cooling () and a liquid desiccant dehumidifier () as the liquid desiccant cooling system () presents an energy-saving and emission-reducing solution to replace traditional mechanical vapor compression refrigeration () systems. This integration overcomes the regional limitations of IEC in hot and humid areas. The newly developed uses exhaust air as the working air source and solar energy as the heat source for desiccant solution regeneration. This study aims to develop an empirical model for the outlet parameters of the , propose an optimization strategy for its operating parameters, and assess the potential and energy performance through parameter analysis and multifactor optimization. By conducting sensitivity analysis and optimizing six critical parameters based on a response surface model (), the system outlet temperature, relative humidity, and coefficient of performance () are improved as the optimization objectives. The regional capability is demonstrated in three selected hot and humid cities. The results indicate that the can significantly increase the by 57.3%. Additionally, it can meet the dehumidification demand when operating with 25% of the air extracted in the during months with high humidity and temperature. This study will facilitate the application of and technologies, guide the design and operation scheme of the system, and promote energy-saving and emission-reducing solutions in hot and humid regions. - 1 January 2022
- Published by Elsevier in Building and Environment
- Vol. 208
Effects of building setback on thermal comfort and air quality in the street canyon
- 1 January 2022
- Published by Elsevier in Building and Environment
- Vol. 208
Effects of building setback on thermal comfort and air quality in the street canyon
- Open Access
- 17 July 2021
- Published by Wiley in International Journal of Aerospace Engineering
- Vol. 2021, 1-18
Performance Deterioration of Pitot Tubes Caused by In-Flight Ice Accretion: A Numerical Investigation
In-flight ice accretion on typical pitot-static systems is numerically investigated to reveal their performance deterioration under both rime and glaze icing. Coupled with the open source computational fluid dynamics (CFD) platform, OpenFOAM, the numerical strategy integrates the airflow determination by the Reynolds-averaged Navier-Stokes equations, droplet collection evaluation by Eulerian representation, and ice accumulation by mass and energy conservation. Under varying inflow conditions and wall temperatures, the calculated ice accretion performance indicates that the ambient temperature has the most significant effect on the icing-induced failure time, leading to an almost exponential growth. Meanwhile, the blocking time is found to be linearly proportional to the increase in wall temperature. With the increase in inflow velocity, the failure time follows a parabolic variation with glaze ice accretion while shows a monotonic reduction under rime icing conditions. In addition, when the angle of attack increases, failure accelerates under both the glaze and rime icing scenarios. These findings provide guidance for the protection design of pitot tubes. A nonlinear regression analysis is further conducted to estimate the failure performance. The predicated failure times show reliable consistency with numerical results, demonstrating the capability of the obtained empirical functions for convenient predictions of failure times within the applicable range.
- 17 July 2021
- Published by Wiley in International Journal of Aerospace Engineering
- Vol. 2021, 1-18
Open AccessPerformance Deterioration of Pitot Tubes Caused by In-Flight Ice Accretion: A Numerical Investigation
In-flight ice accretion on typical pitot-static systems is numerically investigated to reveal their performance deterioration under both rime and glaze icing. Coupled with the open source computational fluid dynamics (CFD) platform, OpenFOAM, the numerical strategy integrates the airflow determination by the Reynolds-averaged Navier-Stokes equations, droplet collection evaluation by Eulerian representation, and ice accumulation by mass and energy conservation. Under varying inflow conditions and wall temperatures, the calculated ice accretion performance indicates that the ambient temperature has the most significant effect on the icing-induced failure time, leading to an almost exponential growth. Meanwhile, the blocking time is found to be linearly proportional to the increase in wall temperature. With the increase in inflow velocity, the failure time follows a parabolic variation with glaze ice accretion while shows a monotonic reduction under rime icing conditions. In addition, when the angle of attack increases, failure accelerates under both the glaze and rime icing scenarios. These findings provide guidance for the protection design of pitot tubes. A nonlinear regression analysis is further conducted to estimate the failure performance. The predicated failure times show reliable consistency with numerical results, demonstrating the capability of the obtained empirical functions for convenient predictions of failure times within the applicable range.
- 21 June 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2323-2326
Hopf bifurcation in the Hodgkin-Huxley model exposed to ELF electrical field
- 21 June 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2323-2326
Hopf bifurcation in the Hodgkin-Huxley model exposed to ELF electrical field