Jiuchuan Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jiuchuan Guo has a total of 112 co-authors. Here are the top co-authors by number of shared publications:
- Jinhong Guo
The M.O.E. Key Laboratory of Laboratory Medical Diagnostics, The College of Laboratory Medicine, Chongqing Medical University, No. 1 Yixueyuan Road, Chongqing 400016, China
29 shared publications Yusheng Fu
9 shared publications- Yusheng Fu
University of Electronic Science and Technology of China, Chengdu, China
8 shared publications - Jie Cheng
School of Sensing Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
4 shared publications Yiming Zhang
4 shared publicationsBianzheng Wang
3 shared publications
Latest Publications
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Communications Letters
- Vol. 30 (10897798) , 2133-2137
Enhanced Half-Aperture OAM Mode Identification Based on Parity-Symmetry Decomposition
Mode division multiplexing based on vortex electromagnetic waves holds great promise for enhancing wireless communication capacity. Accurate demodulation of vortex electromagnetic waves relies on precise identification of orbital angular momentum (OAM) modes. However, due to the hollow divergence of vortex electromagnetic waves, traditional full-aperture mode identification methods are difficult to implement in practice because of the large spatial resource requirements. Consequently, partial-aperture reception, particularly half-aperture reception, is often adopted. Nevertheless, half-aperture reception still faces many challenges that affect accurate mode identification. Motivated by the distinct symmetry properties of even and odd modes, this paper proposes a novel OAM mode identification method based on parity-symmetry decomposition. Simulation results demonstrate that the proposed method maintains high robustness under low signal-to-noise ratio (SNR) and sparse-sampling conditions where conventional methods suffer from pronounced performance degradation. The proposed method reduces hardware complexity and spatial requirements, offering a practical and scalable solution for next-generation OAM-based mode division multiplexing.
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Communications Letters
- Vol. 30 (10897798) , 2133-2137
Enhanced Half-Aperture OAM Mode Identification Based on Parity-Symmetry Decomposition
Mode division multiplexing based on vortex electromagnetic waves holds great promise for enhancing wireless communication capacity. Accurate demodulation of vortex electromagnetic waves relies on precise identification of orbital angular momentum (OAM) modes. However, due to the hollow divergence of vortex electromagnetic waves, traditional full-aperture mode identification methods are difficult to implement in practice because of the large spatial resource requirements. Consequently, partial-aperture reception, particularly half-aperture reception, is often adopted. Nevertheless, half-aperture reception still faces many challenges that affect accurate mode identification. Motivated by the distinct symmetry properties of even and odd modes, this paper proposes a novel OAM mode identification method based on parity-symmetry decomposition. Simulation results demonstrate that the proposed method maintains high robustness under low signal-to-noise ratio (SNR) and sparse-sampling conditions where conventional methods suffer from pronounced performance degradation. The proposed method reduces hardware complexity and spatial requirements, offering a practical and scalable solution for next-generation OAM-based mode division multiplexing.
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Aerospace and Electronic Systems
- Vol. 62 (00189251) , 6505-6520
Joint Range-Angle Estimation for FDA–MIMO Radar: A Probabilistic Tensor Factorization Approach
This article addresses the unambiguous range-angle estimation problem in FDA-MIMO radar systems by formulating received signals as tensor-structured data and developing a tailored probabilistic tensor factorization algorithm. At the modelling stage, we firstly introduce how the compensated signal model of FDA-MIMO is linked to a complex-valued tensor decomposition problem from optimization perspectives. To employ a probabilistic framework, the optimization problem is then interpreted using probabilistic language. Finally, a tensor-based approach is proposed that jointly estimates the range and angle of targets utilizing variational Bayesian inference (VBI) techniques. Critically, our core innovation extends beyond a direct application of an existing Bayesian CP framework. We develop specific modifications to the standard Variational Bayesian Inference (VBI) procedure to handle the unique challenges of the FDA-MIMO signal model. These include the explicit formulation for complex-valued factor matrices with inherent Vandermonde structure and the derivation of efficient update rules that directly operate on this structure. Compared to the prevailing joint angle-range estimation techniques, the proposed method furnishes better estimation precision and more stable performance. Moreover, the algorithm remains effective even in situations where the number of targets is not known as a priori. At the analysis stage, a comprehensive analysis of its convergence properties, automatic tensor rank learning mechanisms, uniqueness condition, and algorithm complexity evaluation is provided. The simulation outcomes validate our theoretical dissection and high light the superior estimation precision of the proposed algorithm in contradistinction to extant schemes.
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Aerospace and Electronic Systems
- Vol. 62 (00189251) , 6505-6520
Joint Range-Angle Estimation for FDA–MIMO Radar: A Probabilistic Tensor Factorization Approach
This article addresses the unambiguous range-angle estimation problem in FDA-MIMO radar systems by formulating received signals as tensor-structured data and developing a tailored probabilistic tensor factorization algorithm. At the modelling stage, we firstly introduce how the compensated signal model of FDA-MIMO is linked to a complex-valued tensor decomposition problem from optimization perspectives. To employ a probabilistic framework, the optimization problem is then interpreted using probabilistic language. Finally, a tensor-based approach is proposed that jointly estimates the range and angle of targets utilizing variational Bayesian inference (VBI) techniques. Critically, our core innovation extends beyond a direct application of an existing Bayesian CP framework. We develop specific modifications to the standard Variational Bayesian Inference (VBI) procedure to handle the unique challenges of the FDA-MIMO signal model. These include the explicit formulation for complex-valued factor matrices with inherent Vandermonde structure and the derivation of efficient update rules that directly operate on this structure. Compared to the prevailing joint angle-range estimation techniques, the proposed method furnishes better estimation precision and more stable performance. Moreover, the algorithm remains effective even in situations where the number of targets is not known as a priori. At the analysis stage, a comprehensive analysis of its convergence properties, automatic tensor rank learning mechanisms, uniqueness condition, and algorithm complexity evaluation is provided. The simulation outcomes validate our theoretical dissection and high light the superior estimation precision of the proposed algorithm in contradistinction to extant schemes.
- 29 October 2025
- Published by Elsevier in Measurement
- Vol. 258
A high-precision multimodal optoelectronic-graph biosensor for home monitoring of diabetes based on lateral flow immunoassay
- 29 October 2025
- Published by Elsevier in Measurement
- Vol. 258
A high-precision multimodal optoelectronic-graph biosensor for home monitoring of diabetes based on lateral flow immunoassay
- 13 August 2025
- Published by Elsevier in Neurocomputing
- Vol. 653
A high-performance and lightweight five-class white blood cell classification network optimized by attention mechanisms
- 13 August 2025
- Published by Elsevier in Neurocomputing
- Vol. 653
A high-performance and lightweight five-class white blood cell classification network optimized by attention mechanisms
- 5 June 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 287, 117667
A miniaturized liver function detection system with machine learning enhancing strategy
- 5 June 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 287, 117667
A miniaturized liver function detection system with machine learning enhancing strategy
- 21 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (24) , 41787-41796
Combining Ultralong Organic Phosphorescent Nanoparticle-Based Lateral Flow Strip Assay With Deep Learning: A Quantitative Detection Method for Creatine Kinase MB
In recent years, there has been an increase in the number of cases of acute chest pain, especially those caused by acute myocardial infarction, which poses a significant health risk. Early and accurate diagnosis of acute myocardial infarction is essential to improve patient prognosis. We used the amphiphilic surfactant polyvinylpyrrolidone to encapsulate high-efficiency organic phosphor molecules (with a phosphorescent quantum yield of 38%) and used such ultralong organic phosphorescent nanoparticles as labels for the lateral flow system to develop a lateral flow system for Creatine kinase MB isoenzyme quantification. We also invoked deep learning to construct a lightweight network model based on residual modules to achieve quantitative detection. We used data augmentation to provide the possibility of a high-precision detection model based on limited samples. Our proposed detection method can detect Creatine kinase MB isoenzyme solutions at concentrations of 0.3ng/ml-100ng/ml and has the advantages of lower cost, less sample requirement, shorter detection time, and more straightforward instrumentation requirements than traditional methods, contributing to more efficient clinical decision-making and treatment.
- 21 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (24) , 41787-41796
Combining Ultralong Organic Phosphorescent Nanoparticle-Based Lateral Flow Strip Assay With Deep Learning: A Quantitative Detection Method for Creatine Kinase MB
In recent years, there has been an increase in the number of cases of acute chest pain, especially those caused by acute myocardial infarction, which poses a significant health risk. Early and accurate diagnosis of acute myocardial infarction is essential to improve patient prognosis. We used the amphiphilic surfactant polyvinylpyrrolidone to encapsulate high-efficiency organic phosphor molecules (with a phosphorescent quantum yield of 38%) and used such ultralong organic phosphorescent nanoparticles as labels for the lateral flow system to develop a lateral flow system for Creatine kinase MB isoenzyme quantification. We also invoked deep learning to construct a lightweight network model based on residual modules to achieve quantitative detection. We used data augmentation to provide the possibility of a high-precision detection model based on limited samples. Our proposed detection method can detect Creatine kinase MB isoenzyme solutions at concentrations of 0.3ng/ml-100ng/ml and has the advantages of lower cost, less sample requirement, shorter detection time, and more straightforward instrumentation requirements than traditional methods, contributing to more efficient clinical decision-making and treatment.
- 5 October 2024
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 379, 115956
Long afterglow nanoprobes labeled image enhancement using deep learning in rapid and sensitive lateral flow immunoassay
- 5 October 2024
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 379, 115956
Long afterglow nanoprobes labeled image enhancement using deep learning in rapid and sensitive lateral flow immunoassay
- 18 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (21) , 34618-34624
An Ultraminiaturized Inflammation Monitoring Platform Implemented by Long Afterglow Lateral Flow Immunoassay
Abnormal fluctuations of inflammatory factors may reflect the immune response and pathological pro-cesses of the body. The real-time monitoring of these indicators is critical for the treatment and prognosis of infectious or autoimmune diseases. Among numerous point-of-care testing methods, lateral flow immunoassay (LFIA) has a high impact due to its unique superiority in convenience and rapidity. However, traditional colloidal gold based LFIAs suffer from qualitative or semi-quantitative detection, while most of the optical nanoprobes enabled quantitative LFIAs re-quire expensive equipment for signal reading, not benefiting widespread needs for personal or home use. To confront these challenges, in this work, we propose a new generation of LFIA by using ultra-long afterglow nanoprobes (UANPs) and a self-developed miniaturized sensing device for simultaneous detection of C-reactive protein (CRP) and serum amyloid A (SAA). Hydrophilic and surface-modified UANPs are prepared in uniform size and good dispersibility by a two-step method. The afterglow sensing strategy effectively avoids biological endogenous background and excitation light interference. We therefore develop an ultra-miniaturized low-cost device with conventional optical components, omitting complicated filtering modules. As a result, the UANP-LFIA achieved detection linear ranges of 0.7~250 ng/mL for CRP and 1~200 ng/mL for SAA, with detection limits of 0.67 ng/mL and 0.81 ng/mL, respectively. Moreover, the palm-size sensing device can be interconnected with smart terminals and is capable of uploading medical data, providing a more accurate strategy for identifying infection types and assessing disease severity.
- 18 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (21) , 34618-34624
An Ultraminiaturized Inflammation Monitoring Platform Implemented by Long Afterglow Lateral Flow Immunoassay
Abnormal fluctuations of inflammatory factors may reflect the immune response and pathological pro-cesses of the body. The real-time monitoring of these indicators is critical for the treatment and prognosis of infectious or autoimmune diseases. Among numerous point-of-care testing methods, lateral flow immunoassay (LFIA) has a high impact due to its unique superiority in convenience and rapidity. However, traditional colloidal gold based LFIAs suffer from qualitative or semi-quantitative detection, while most of the optical nanoprobes enabled quantitative LFIAs re-quire expensive equipment for signal reading, not benefiting widespread needs for personal or home use. To confront these challenges, in this work, we propose a new generation of LFIA by using ultra-long afterglow nanoprobes (UANPs) and a self-developed miniaturized sensing device for simultaneous detection of C-reactive protein (CRP) and serum amyloid A (SAA). Hydrophilic and surface-modified UANPs are prepared in uniform size and good dispersibility by a two-step method. The afterglow sensing strategy effectively avoids biological endogenous background and excitation light interference. We therefore develop an ultra-miniaturized low-cost device with conventional optical components, omitting complicated filtering modules. As a result, the UANP-LFIA achieved detection linear ranges of 0.7~250 ng/mL for CRP and 1~200 ng/mL for SAA, with detection limits of 0.67 ng/mL and 0.81 ng/mL, respectively. Moreover, the palm-size sensing device can be interconnected with smart terminals and is capable of uploading medical data, providing a more accurate strategy for identifying infection types and assessing disease severity.