Dongli Jia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dongli Jia has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Keyan Liu
China Electric Power Research Institute, Beijing 100192, China
2 shared publications Chenhao Wei
China Agricultural University, Haidian, Beijing 100083, China
1 shared publication- Feng Deng
School of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha, China
1 shared publication - Fengzhan Zhao
College of Information and Electrical Engineering, China Agricultural University, Beijing 100083, China
1 shared publication Guangfei Geng
China Agricultural University, Haidian, Beijing 100083, China
1 shared publicationKaiyuan He
China Electric Power Research Institute Company Ltd., Haidian, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 24 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 147772-147783
A Single-Ended Fault Location Method for DC Transmission Lines Based on Inverse Distance Weighted Interpolation
The accuracy and reliability of single-ended fault location methods are often affected by boundary elements and transition resistances. This paper proposes a single-ended fault location method for DC transmission lines based on the initial traveling wave dominant frequency (ITWDF) attenuation characteristics. Firstly, the attenuation characteristics of the initial traveling wave frequency component are analyzed, and the attenuation law and distribution differences between the frequency component and fault distance are revealed. Secondly, to accurately extract and describe the trend of the initial traveling wave frequency component with the change of fault distance, the energy of the initial traveling wave is constructed, and the mathematical expression of the ITWDF related to the fault distance and unit length distortion coefficient is obtained. Theoretical analysis verifies that the ITWDF exhibits a monotonic attenuation mapping relationship with increasing fault distance. In addition, the attenuation characteristics of the ITWDF are not affected by fault impedance. Finally, a fault sample set containing the ITWDF and reference unit length distortion coefficients at different positions is constructed. The fault location is calculated using the ITWDF and the reference unit length distortion coefficient, with continuous wavelet transform and inverse distance weighting interpolation algorithms applied, respectively. Simulation results show that the proposed method can reliably locate faults under high-impedance conditions of up to 800Ω, and the absolute error is less than 200m. Moreover, the proposed method can be applied to DC lines with various boundary structures, improving the reliability of single-ended fault location.
- 24 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 147772-147783
Open AccessA Single-Ended Fault Location Method for DC Transmission Lines Based on Inverse Distance Weighted Interpolation
The accuracy and reliability of single-ended fault location methods are often affected by boundary elements and transition resistances. This paper proposes a single-ended fault location method for DC transmission lines based on the initial traveling wave dominant frequency (ITWDF) attenuation characteristics. Firstly, the attenuation characteristics of the initial traveling wave frequency component are analyzed, and the attenuation law and distribution differences between the frequency component and fault distance are revealed. Secondly, to accurately extract and describe the trend of the initial traveling wave frequency component with the change of fault distance, the energy of the initial traveling wave is constructed, and the mathematical expression of the ITWDF related to the fault distance and unit length distortion coefficient is obtained. Theoretical analysis verifies that the ITWDF exhibits a monotonic attenuation mapping relationship with increasing fault distance. In addition, the attenuation characteristics of the ITWDF are not affected by fault impedance. Finally, a fault sample set containing the ITWDF and reference unit length distortion coefficients at different positions is constructed. The fault location is calculated using the ITWDF and the reference unit length distortion coefficient, with continuous wavelet transform and inverse distance weighting interpolation algorithms applied, respectively. Simulation results show that the proposed method can reliably locate faults under high-impedance conditions of up to 800Ω, and the absolute error is less than 200m. Moreover, the proposed method can be applied to DC lines with various boundary structures, improving the reliability of single-ended fault location.
- Open Access
- 25 May 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 1-13
Optimal allocation of photovoltaic energy storage on user side and benefit analysis of multiple entities
- 25 May 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 1-13
Open AccessOptimal allocation of photovoltaic energy storage on user side and benefit analysis of multiple entities
- Open Access
- 27 July 2021
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2021, 1-11
Energy Loss Calculation of Low Voltage Distribution Area Based on Variational Mode Decomposition and Least Squares Support Vector Machine
In order to improve the accuracy of theoretical energy loss calculation in low voltage distribution area (LV-area), this paper proposes a new prediction method based on variational mode decomposition (VMD) and particle swarm optimization (PSO) least squares support vector machine (LSSVM). Firstly, the main influencing factors of energy loss calculation in LV-area are determined by the grey correlation method, which reflects the data-driven characteristic of the method and ensures the objectivity of the prediction results and the generalization of the calculation model. Secondly, the trend component and fluctuation component are obtained by VMD of daily energy loss series in the LV-area. The variable set of main influencing factors of energy losses is used as the input variable of LSSVM, and the VMD result of the energy loss sequence is used as the output. The theoretical energy loss training and calculation model of LV-area is established. Compared with the traditional calculation model, this model has more accurate calculation accuracy by taking into account the frequency characteristics of energy losses in different frequency bands. PSO is used to optimize the parameters of LSSVM for the purpose of improving the accuracy of LSSVM. Finally, an example of 252 LV-area in a city in northern China is given to verify the validity of the proposed method. The results indicate that the proposed method generates more accurate results.
- 27 July 2021
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2021, 1-11
Open AccessEnergy Loss Calculation of Low Voltage Distribution Area Based on Variational Mode Decomposition and Least Squares Support Vector Machine
In order to improve the accuracy of theoretical energy loss calculation in low voltage distribution area (LV-area), this paper proposes a new prediction method based on variational mode decomposition (VMD) and particle swarm optimization (PSO) least squares support vector machine (LSSVM). Firstly, the main influencing factors of energy loss calculation in LV-area are determined by the grey correlation method, which reflects the data-driven characteristic of the method and ensures the objectivity of the prediction results and the generalization of the calculation model. Secondly, the trend component and fluctuation component are obtained by VMD of daily energy loss series in the LV-area. The variable set of main influencing factors of energy losses is used as the input variable of LSSVM, and the VMD result of the energy loss sequence is used as the output. The theoretical energy loss training and calculation model of LV-area is established. Compared with the traditional calculation model, this model has more accurate calculation accuracy by taking into account the frequency characteristics of energy losses in different frequency bands. PSO is used to optimize the parameters of LSSVM for the purpose of improving the accuracy of LSSVM. Finally, an example of 252 LV-area in a city in northern China is given to verify the validity of the proposed method. The results indicate that the proposed method generates more accurate results.