Marcos Rodriguez Martín
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marcos Rodriguez Martín has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Guido Mazzinari
Department of Anesthesiology, Hospital Universitario y Politécnico La Fé, Valencia, Spain
2 shared publications - Jaime Zorrilla
Department of Anaesthesiology, Hospital General Universitario Gregorio Marañón, 28007 Madrid, Spain
2 shared publications - José María Pérez Peña
Department of Anaesthesiology, Hospital General Universitario Gregorio Marañón, 28007 Madrid, Spain
2 shared publications - Luis Enrique Olmedilla Arnal
Department of Anaesthesiology, Hospital General Universitario Gregorio Marañón, 28007 Madrid, Spain
2 shared publications - Marcus Josephus Schultz
Department of Anaesthesia, General Intensive Care and Pain Management, Division of Cardiothoracic and Vascular Anaesthesia & Critical Care Medicine, Medical University Wien, 1090 Vienna, Austria
2 shared publications - Maria Pilar Argente Navarro
Anaesthesiology Department, La Fe University and Polytechnic Hospital, Av. de Fernando Abril Martorell, 106, 46026 Valencia, Spain
2 shared publications
Latest Publications
- Open Access
- 14 March 2023
- Published by MDPI AG in Biomedicines
- Vol. 11 (3) , 891
An Individualized Low-Pneumoperitoneum-Pressure Strategy May Prevent a Reduction in Liver Perfusion during Colorectal Laparoscopic Surgery
High intra-abdominal pressure (IAP) during laparoscopic surgery is associated with reduced splanchnic blood flow. It is uncertain whether a low IAP prevents this reduction. We assessed the effect of an individualized low-pneumoperitoneum-pressure strategy on liver perfusion. This was a single-center substudy of the multicenter ‘Individualized Pneumoperitoneum Pressure in Colorectal Laparoscopic Surgery versus Standard Therapy II study’ (IPPCollapse–II), a randomized clinical trial in which patients received an individualized low-pneumoperitoneum strategy (IPP) or a standard pneumoperitoneum strategy (SPP). Liver perfusion was indirectly assessed by the indocyanine green plasma disappearance rate (ICG–PDR) and the secondary endpoint was ICG retention rate after 15 min (R15) using pulse spectrophotometry. Multivariable beta regression was used to assess the association between group assignment and ICG–PDR and ICG–R15. All 29 patients from the participating center were included. Median IAP was 8 (25th–75th percentile: 8–10) versus 12 (12,12) mmHg, in IPP and SPP patients, respectively (p < 0.001). ICG–PDR was higher (OR 1.42, 95%-CI 1.10–1.82; p = 0.006) and PDR–R15 was lower in IPP patients compared with SPP patients (OR 0.46, 95%-CI 0.29–0.73; p = 0.001). During laparoscopic colorectal surgery, an individualized low pneumoperitoneum may prevent a reduction in liver perfusion.
- 14 March 2023
- Published by MDPI AG in Biomedicines
- Vol. 11 (3) , 891
Open AccessAn Individualized Low-Pneumoperitoneum-Pressure Strategy May Prevent a Reduction in Liver Perfusion during Colorectal Laparoscopic Surgery
High intra-abdominal pressure (IAP) during laparoscopic surgery is associated with reduced splanchnic blood flow. It is uncertain whether a low IAP prevents this reduction. We assessed the effect of an individualized low-pneumoperitoneum-pressure strategy on liver perfusion. This was a single-center substudy of the multicenter ‘Individualized Pneumoperitoneum Pressure in Colorectal Laparoscopic Surgery versus Standard Therapy II study’ (IPPCollapse–II), a randomized clinical trial in which patients received an individualized low-pneumoperitoneum strategy (IPP) or a standard pneumoperitoneum strategy (SPP). Liver perfusion was indirectly assessed by the indocyanine green plasma disappearance rate (ICG–PDR) and the secondary endpoint was ICG retention rate after 15 min (R15) using pulse spectrophotometry. Multivariable beta regression was used to assess the association between group assignment and ICG–PDR and ICG–R15. All 29 patients from the participating center were included. Median IAP was 8 (25th–75th percentile: 8–10) versus 12 (12,12) mmHg, in IPP and SPP patients, respectively (p < 0.001). ICG–PDR was higher (OR 1.42, 95%-CI 1.10–1.82; p = 0.006) and PDR–R15 was lower in IPP patients compared with SPP patients (OR 0.46, 95%-CI 0.29–0.73; p = 0.001). During laparoscopic colorectal surgery, an individualized low pneumoperitoneum may prevent a reduction in liver perfusion.
- 27 June 2018
- Published by Springer Nature in Surgical Endoscopy
- Vol. 33 (1) , 252-260
A multifaceted individualized pneumoperitoneum strategy for laparoscopic colorectal surgery: a multicenter observational feasibility study
While guidelines for laparoscopic abdominal surgery advise using the lowest possible intra-abdominal pressure, commonly a standard pressure is used. We evaluated the feasibility of a predefined multifaceted individualized pneumoperitoneum strategy aiming at the lowest possible intra-abdominal pressure during laparoscopic colorectal surgery.
- 27 June 2018
- Published by Springer Nature in Surgical Endoscopy
- Vol. 33 (1) , 252-260
A multifaceted individualized pneumoperitoneum strategy for laparoscopic colorectal surgery: a multicenter observational feasibility study
While guidelines for laparoscopic abdominal surgery advise using the lowest possible intra-abdominal pressure, commonly a standard pressure is used. We evaluated the feasibility of a predefined multifaceted individualized pneumoperitoneum strategy aiming at the lowest possible intra-abdominal pressure during laparoscopic colorectal surgery.